Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium recovery system at IB3a

The increasing need for optimal and sustainable use of cryogenic resources to support Fermilab’s scientific mission has highlighted the necessity of improving the Laboratory’s helium management practices. An assessment of cryogenic test facilities identified the Technical Division’s Industrial Building 3a (IB3A) as a key site requiring upgrades to integrate a helium recovery system. The IB3A facility is essential for characterizing and testing superconductors, cables, and coils for various R&D projects, including the US High-Luminosity LHC Accelerator Upgrade Project (AUP), Mu2e, and other external collaborations. Currently, the facility relies on 500 L helium Dewars and vents the vaporized helium directly into the atmosphere, leading to significant helium loss. Given the non-renewable nature of helium, recovering and reusing this resource is critical for the sustainability of Fermilab’s operations. To address this challenge, a project has been initiated to connect IB3A to an existing helium purification station and refrigeration system located in another building via a dedicated pipeline pass over the roof of several buildings. This solution will enable the efficient capture of vented helium, its transfer to the purification station, and subsequent liquefaction for reuse in future operations. The project includes a detailed design phase, specifying the pipeline route, flow control mechanisms, and integration with the existing cryogenic infrastructure, followed by phased implementation and commissioning. By implementing this pipeline connection and upgrading IB3A, Fermilab aims to significantly reduce helium waste, lower operational costs, and align with its commitment to sustainability. This initiative provides a model for resource-efficient cryogenic operations and reinforces the Laboratory’s capacity to support its science mission for the long term.

Porwisiak, D. [Fermilab]↗

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.

43 PARTICLE ACCELERATORS↗

Application Of The ASME Boiler And Pressure Vessel Code In The Design Of SSR Cryomodule Beamlines For PIP-II Project At Fermilab

This contribution reports the design of the main components used to interconnect SRF cavities and superconducting focusing lenses in the SSR Cryomodule beamlines, developed in the framework of the PIP-II project at Fermilab. The focus of the present contribution is on the design and testing of the edge-welded bellows according to ASME Boiler and Pressure Vessel Code. The activities performed to qualify the bellows to be assembled in cleanroom, for operation in high vacuum, cryogenic environments, and their characterization from magnetic standpoint, will also be presented.

43 PARTICLE ACCELERATORS↗

A large millikelvin platform at Fermilab for quantum computing applications

The need for larger mK cooling platforms is being driven by the desire to host ever growing numbers of cryogenic qubits in quantum computing platforms. As part of the Superconducting Quantum Materials and Systems Center at Fermilab funded through the Department of Energy under the National Quantum Initiative, we are developing a cryogenic platform capable of reaching millikelvin temperatures in an experimental volume of 2 meters diameter by approximately 1.5 meters in height. The platform is intended to host a three-dimensional qubit architecture based on superconducting radiofrequency accelerator cavity technologies. This paper describes the baseline design of the platform, along with the expected key performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

LBNF Internal Cryogenics Supports Design

This poster presents requirements, methodology, and results of the LBNF Internal Cryogenics External Supports conceptual design. Forces and flexibility analyses, membrane cryostat restrictions, and simplicity were all taken into consideration for the design.

43 PARTICLE ACCELERATORS↗

Motivation and Development of a Compact Superconducting Accelerator for X-ray Medical Device Sterilization

Fermilab is developing a compact superconducting (CSRF) accelerator as a source of a high-power, high-energy electron beam to produce an x-ray beam comparable to $\geq$ 2 MCi of cobalt-60. As part of this development, we are presently assembling a 20 kW, 1.6 MeV prototype that incorporates the four enabling technologies described below. These technologies support a heat budget that is within the capacity of commercially available cryocoolers and eliminate the need for liquid cryogens. The use of superconducting technologies promises efficiencies, wall-plug to beam, of 80% or greater. A summary of the design and progress to date will be given. In addition, we will present a review of developments within the medical device sterilization industry that are motivating the development of this technology.

43 PARTICLE ACCELERATORS↗

ODU Optimization of Nb3Sn supttering on SRF structures

High efficiency Superconducting radio-frequency (SRF) cavities are the key technology to cost-effective Continuous Wave (CW) SRF accelerators. Recent advances in Nb3Sn coatings on the inner surface of SRF cavities showed the potential for this material to significantly cut the capital and operating cost of SRF accelerators. The best results are presently achieved with Nb3Sn films coated by using the so-called vapor diffusion technique. Several alternative approaches have been and are being investigated such as electrochemical deposition, bronze routes, and sputtering. Among these techniques, magnetron sputtering is a versatile technique, which has been demonstrated to deposit Nb3Sn films on SRF cavities. The technique requires further development to compete with the results demonstrated on the cavities coated with the vapor diffusion techniques. The team to develop the novel technique includes a graduate student from Old Dominion University (ODU) and other experts. ODU Prof. Elsayed-Ali directs the graduate student to coat samples and cavities in the new coating system and analyze samples with different surface science techniques. Dr. Grigory Eremeev from Fermilab assists with 2.6 GHz cavities for coating, cavity characterization at cryogenic temperature, and result analysis. The research is funded by the Office of High Energy Physics at the US Department of Energy at both Fermilab and ODU

43 PARTICLE ACCELERATORS↗

Aging of Self-Assembled Lead Halide Perovskite Nanocrystal Superlattices: Effects on Photoluminescence and Energy Transfer

Excitonic coupling, electronic coupling, and cooperative interactions in self-assembled lead halide perovskite nanocrystals were reported to give rise to a red-shifted collective emission peak with accelerated dynamics. Here we report that similar spectroscopic features could appear as a result of the nanocrystal reactivity within the self-assembled superlattices. This is demonstrated by studying CsPbBr 3 nanocrystal superlattices over time with room-temperature and cryogenic micro-photoluminescence spectroscopy, X-ray diffraction, and electron microscopy. It is shown that a gradual contraction of the superlattices and subsequent coalescence of the nanocrystals occurs over several days of keeping such structures under vacuum. As a result, a narrow, low-energy emission peak is observed at 4 K with a concomitant shortening of the photoluminescence lifetime due to the energy transfer between nanocrystals. When exposed to air, self-assembled CsPbBr 3 nanocrystals develop bulk-like CsPbBr 3 particles on top of the superlattices. At 4 K, these particles produce a distribution of narrow, low-energy emission peaks with short lifetimes and excitation fluence-dependent, oscillatory decays. Overall, the aging of CsPbBr 3 nanocrystal assemblies dramatically alters their emission properties and that should not be overlooked when studying collective optoelectronic phenomena nor confused with superfluorescence effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface structure studies in 2D and 3D Nb resonators using GI-XRD

Superconductor radio frequency (SRF) Nb-resonators are a key element in the development of new generations of particle accelerators as well as in the fabrication of 3D circuit QED architecture for quantum computing. Nevertheless, Niobium is extremally reactive to light elements such as C, N, O and H, and therefore to the impurities ordering under special conditions, e.g., cryogenic temperatures. Since these resonators are put through a series of metallurgical and chemical processes, the number of impurities in the solid increases in tens of ppm. Upon operational conditions ~1.6 K, Nb become vulnerable to H atoms ordering, which leads to the nucleation of secondary phases such as Nb-hydrides. Thereupon to the energy dissipation and eventually to the superconductivity breakdown known as Q-disease and potentially High-Field Q-slope. In this contribution, we present a detailed structural analysis by high-energy grazing-incidence X-ray diffraction of specimens extracted from 3D Nb resonators to shed light on the kinetic formation of the resulting secondary phases and their crystal phase identification upon cooling and heating cycles. To our knowledge, this is the first study carried out in resonators samples using a light source, shallow angles and temperatures near ~4 K. Consequently, this work opens new routes to understand the chemical and phase composition, crystal and electronic structure of the Nb surface at temperatures near the operating conditions as a strategy to improve the physical and functional properties of Nb superconducting resonators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Free Electron Laser Accelerator Lattice Design Using Laser-Assisted Bunch Compression

We report the start-to-end modeling of our accelerator lattice design employing a laser-assisted bunch compression (LABC) scheme in an X-ray free electron laser (XFEL), using the proposed Matter-Radiation Interactions in Extremes (MaRIE) XFEL parameters. The accelerator lattice utilized a two-stage bunch compression scheme, with the first bunch compressor performing a conventional bulk compression enhancing the beam current from 20 A to 500 A, at 750 MeV. The second bunch compression was achieved by modulating the beam immediately downstream of the first bunch compressor by a laser with 1-μm wavelength in a laser modulator, accelerating the beam to the final energy of 12 GeV, and compressing the individual 1-μm periods of the modulated beam into a sequence of microbunches with 3-kA current spikes by the second bunch compressor. The LABC architecture presented had been developed based on the scheme of enhanced self-amplified spontaneous emission (ESASE), but operated in a disparate regime of parameters. Enabled by the novel technology of the cryogenic normal conducting radiofrequency photoinjector, we investigated an electron beam with ultra-low emittance at the starting point of the lattice design. Our work aimed at mitigating the well-known beam instabilities to preserve the beam emittance and suppress the energy spread growth.

43 PARTICLE ACCELERATORS↗