Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cryogenics Python Coding Calculations for Nitrogen & Helium Loss

Helium and Nitrogen are two significant chemical elements that are used to advance cryogenic scientific breakthroughs. Helium is a colorless, odorless, and tasteless gas that becomes liquid at (−452 °F). Nitrogen is a gas at its standard conditions; It becomes solid once temperatures reach below (-346 °F), and it boils and becomes a gas once temperatures reach above (-320 °F). During this research project I used a web-based interactive computing platform called Jupyter Lab to modify various python programs that calculate, and display helium and nitrogen inventory lost from three cryo plants

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LBNF/DUNE Liquid Argon Roadmap

The Deep Underground Neutrino Experiment (DUNE) is an international flagship venture to unlock the mysteries of neutrinos. Hosted at the Sanford Underground Research Facility (SURF) and supported by the Long-Baseline Neutrino Facility (LBNF), DUNE relies on nearly 75,000 tonnes of ultrapure liquid argon (LAr) housed in state-of-the-art cryostats. Transporting such vast quantities of LAr to its destination a mile underground in Lead, SD, is a logistical and engineering challenge. The process begins with securing large quantities of liquid argon from suppliers located far from the site, with major sources situated near Houston, TX and Chicago, IL. The receiving facility, located atop a mountain with steep, often snow-covered access roads, provides limited maneuverability for trucks and can only handle two deliveries simultaneously. The facility serves as an entry point for argon to the greater LBNF cryogenic system. It is furnished with truck unloading stations, limited buffer storage of some 280 tonnes capacity, and vaporizers. The last are crucial for converting liquid argon into gas for transfer down the Ross Shaft, eliminating the need for cryogens in the vertical pipeline. These constraints, along with other operational factors, cap the delivery rate at 70 tonnes per day. Once underground, the argon is purified and recondensed before filling the cryostats. This roadmap outlines the integrated supply chain and cryogenic systems that enable the delivery of LAr to support DUNE’s groundbreaking physics research.

Maciazka, Matt [Fermilab]↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Mapping ammonia-diesel combustion on a single-cylinder 107 mm bore diesel engine retrofitted for ammonia port-fuel injection

Ammonia is garnering significant interest from the international maritime sector as an alternative fuel. It is attractive as a hydrogen carrier and as a fuel because it has a higher volumetric energy density compared with gaseous or liquid hydrogen, making it easier to store and transport without requiring high pressures or cryogenic storage. Ammonia has significant toxicity concerns, but safe handling procedures have already been established because it is one of the most widely produced chemicals worldwide for use as a fertilizer. Barriers to consuming NH 3 as a fuel in engines include (1) less favorable ignition energy and flame speed compared with conventional fuels; (2) emissions challenges, including potentially high NH 3 , NO X , and N 2 O emissions; and (3) fuel delivery and handling challenges. Although NH 3 has been used to fuel compression-ignition marine engines in limited demonstration projects, technical barriers still exist. The use of NH 3 as a fuel in smaller-bore, high-speed auxiliary engines for large vessels and for smaller inland and coastal marine applications remains unaddressed. This work investigates a late-injection diesel pilot ignition dual-fuel NH 3 strategy using a single-cylinder, high-speed Cummins four-stroke diesel engine platform with a 107 mm bore and 1.1 L displacement per cylinder. The engine was modified for port fuel injection of heated gaseous anhydrous NH 3 . The diesel fuel injection system and the combustion geometry were unmodified to represent a retrofit application, which would minimize additional hardware to maximize diesel fuel displacement with NH 3 . Furthermore, the results show the applicability of a late injection diesel pilot strategy to overcome the challenging fuel properties of NH 3 over the engine operating envelope. Mapping results focusing on emissions are presented, and comparisons are made to a conventional diesel combustion baseline.

Ship engines↗

A multi-channel cryogenic low-noise skipper-CCD readout ASIC

• Skipper CCDs provide exceptionally low noise useful for dark matter detection• MIDNA ASIC enables scaled cryogenic Skipper CCD readout• Noise performance proven to specification at room temperature with CCD• Liquid nitrogen measurements show functionality with more to come• Future development will integrate more sensitive signals and averaging capability

England, Troy↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

Design of Stand-Alone Cryomodule based on Superconducting Quarter-Wave Resonator

Present superconducting accelerators require a central refrigeration system and piping to distribute liquid helium and nitrogen. Stand-alone cryocooler-based systems are of significant interest both to scientific and industrial customers, as they allow applications at facilities where no cryogenic equipment and expertise exists, where it is undesirable to develop additional cryogenic systems, or where a mobile system that can be transported between beamlines or facilities is required. The technical challenge of this approach is to minimize the heat losses to the liquid helium so that commercially available, self-contained cryocoolers are able to handle the thermal load. This paper presents an improved design for a stand-alone quarter-wave resonator (QWR) cryomodule a based on commercially available cryocoolers. This cryomodule has a particular application in the ATLAS intensity upgrade project where it will house a 72.75 MHz QWR for beam energy adjustments to experimental areas, where no helium cryogenic systems exist. The described cryomodule may also be the critical part of a turnkey system with application to material processing, semiconductor manufacturing, food irradiation and homeland security. The development of low heat loss peripheral components reduces cost and widens applicability of the system. We will discuss the cryomodule and RF coupler designs, including numerical thermal and structural analyses.

43 PARTICLE ACCELERATORS↗

Liquid helium fluid dynamics studies. Final Technical Report

Future high energy physics accelerators depend on a number of advanced technologies to open the many doors of scientific discovery. Among these advanced technologies, superconducting magnets and superconducting radio frequency (SRF) cavities are the backbone of the accelerator and detector systems. But all these low temperature systems depend critically on successful and reliable operation of their supporting technologies, among which the liquid helium cooling system is of the utmost importance. To improve the quality of these systems both in terms of efficiency and reliability, a robust helium cryogenics research and development (R&D) effort is required. The proposed research to be conducted by the FSU cryogenics group aims to produce fundamental knowledge that meets this R&D need. The projects that we have completed over the past grant period at Florida State University consist of experimental research on liquid helium fluid dynamics and heat transfer problems relevant to the development of future superconducting particle physics accelerators. Liquid helium is the coolant used in all such facilities and in many of these facilities He II (the low temperature phase of liquid helium also known as superfluid helium) is preferred due to its outstanding heat transfer characteristics. The work consists of two main experimental studies that probe both fundamental as well as practical aspects of liquid helium cooling. The first is a broad and fundamental study of the heat and mass transfer processes that can occur during a sudden catastrophic loss of vacuum (SCLV) incident in a superconducting accelerator. SCLV refers to the remote but extremely critical accident scenario where atmospheric pressure air is allowed to flood into the insulating vacuum system and impinge on the liquid helium cooled surfaces in the accelerator. Safe performance and recovery from such accidents is essential to the reliable operation of superconducting accelerators. The dynamics of this process is quite complex and so our approach is to conduct a series of well-orchestrated experiments that probe the various physical phenomena that can occur during an SCLV event. The experiments are coupled with analytic and numerical analysis in an effort to develop a general understanding of the process and to assist with future accelerator design and development. The second activity is directed toward fundamental understanding of heat and mass transfer in He II, which is essential to the design of superconducting magnets and radio frequency cavities in accelerators. The work consists of flow visualization of the dynamics of He II using laser assisted techniques. Two complementary techniques are used to study the fundamentals of the turbulent state. The first technique uses neutrally buoyant solid hydrogen particles to probe the flow fields of the superfluid and normal fluid components. The other technique uses laser excited He2* molecules as tracers of the normal fluid motion within the He II. The activities also included an effort to use visualization techniques to locate transient hot spots in radio frequency superconducting cavities. Such work provides valuable information about the heat transfer process in He II and its impact on the performance of superconducting devices. The research effort at Florida State University is not directly in support of a specific high energy physics experiment or facility. Rather, the work is general and coordinated with HEP accelerator laboratories to provide valuable insight that can assist with future accelerator development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a Conduction-Cooled Superconducting Undulator

In superconducting undulators (SCUs) that are currently operating at the Advanced Photon Source, the undulator magnets are indirectly cooled with liquid helium penetrating through channels in the magnet cores. The liquid helium is stored in a tank that is cooled by cryocoolers. However, a cryogen-free version of a superconducting undulator in which the undulator magnets are conduction-cooled is also possible, as has been realized in the SCUs developed at ANKA. We are currently working on a conceptual design of a conduction-cooled planar superconducting undulator. The measured load lines of cryocoolers and the measured thermal conductance of various thermal links are used in the thermal analysis. Also, various materials for the undulator magnet cores are being considered. This paper reports the thermal design of a conduction-cooled planar SCU.

cryocooler↗

Enabling thermal efficiency improvement and waste heat recovery using liquid air harnessed from offshore renewable energy sources

A novel approach using decoupled processes to harness offshore renewable energy, from marine hydrokinetics, ocean waves, wind, and solar to produce liquid air, is presented here. Offshore renewables interconnection using submarine medium- and high-voltage direct current technologies are used to produce liquid air that can be transported to end-use locations using repurposed liquefied natural gas tankers. Two important possibilities arise from using the proposed technology. The first possibility allows the integration with conventional thermal cycles to improve efficiency. This approach can be used to leverage efficiencies of thermal systems that have already reached a plateau in the maximum achievable efficiency via design and operation optimization. The second possibility is related to the incorporation of low temperature cycles to recover waste heat from other thermal processes. This is important considering that waste heat accounts for more than 60% of the consumed energy in the United States. A detailed technical description of the complete cycle from cryogen generation to end-use of energy is provided. Estimation of efficiency enhancement for thermal plants using liquid air including waste heat recovery is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-voltage and electrode system for a cryogenic experiment to search for the neutron electric dipole moment

The cryogenic approach to the search for the neutron electric dipole moment—performing the experiment in superfluid liquid helium—holds promise for a substantial increase in sensitivity, potentially enabling a sensitivity level of 10 −28 𝑒cm. A crucial component in realizing such an experiment is the high-voltage and electrode system capable of providing an electric field of 75 kV/cm. This, in turn, requires an electric potential of 635 kV to be applied to the high-voltage electrode, while simultaneously satisfying other experimental constraints, such as those on heat load and magnetic noise requirements. In this work, we describe the outcome of a comprehensive development program addressing these challenges. It outlines the system requirements, discusses new insights into relevant physical phenomena, and details selected technical solutions with their corresponding experimental demonstrations and expected performance. The results collectively demonstrate the successful development of the necessary technology for the high-voltage and electrode system for this approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Industrial Carbon Capture from a Cement Facility Using the Cryocap™ FG Process

The objective of the project was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO 2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO 2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The industrial host site emits approximately 3 million tonnes CO 2 /year based on plant data from 2020-2022. The captured CO 2 will meet the requirements of transport (Pipeline Grade) and geological storage, and the geological storage facilities within 80 miles of the CO 2 source. The impact of the project on Environmental Justice and the regional economy was also analyzed.

01 COAL, LIGNITE, AND PEAT↗

Industrial Carbon Capture from a Cement Facility Using the Cryocap FG Process (FE0032136)

The project's objective was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The impact of the project on Environmental Justice and the regional economy was also analyzed.

01 COAL, LIGNITE, AND PEAT↗

Industrial Carbon Capture from a Cement Facility Using the CryocapTM FG Process (2023 FECM/NETL Conference Proceeding)

The project's objective was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The impact of the project on Environmental Justice and the regional economy was also analyzed.

01 COAL, LIGNITE, AND PEAT↗