Search NASA⌕ Search

SEARCH · Search NASA

Results for “current limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Generalized Approach to Aircraft Trajectory Prediction via Supervised Deep Learning

As research advances diverse forms and missions of aircraft, the National Airspace System (NAS) will become increasingly crowded, limiting current communications resources to accommodate aviation operations. Ongoing research proposes a paradigm of airspace communications, such that resources are autonomously and dynamically allocated via intelligent agents; this allocation requires accurate representations of the NAS, including the predicted positions of aircraft. State-of-the-art research emphasizes the importance of a hybrid-recurrent framework for trajectory prediction and compares the impact of commonly considered weather data on prediction accuracy. However, current research has been limited in its scope of efforts, frequently utilizing a unique flight route, architecture, set of weather data, and date range. This article considers the challenges of generalizing hybrid-recurrent predictive models for flight trajectories. Results illustrate an increase in error variance when identical models are trained over a generalized set of flights; this may be mitigated with careful tuning of hyperparameters, both in the network structure and optimization algorithms. Even so, an irreducible vertical error was identified, resulting from the complex takeoff and landing procedures which can not be correlated to functions of weather or additional assumptions of aircraft behavior. Finally, the use of a test route indicates that generalized models still do not possess sufficient knowledge for general aircraft predictions, with mean error increases ranging from 70-500%. These results illustrate the need for continued efforts on improving model versatility, as well as potential limitations for spectrum allocation near airports and other centers.

Nathan Schimpf↗

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar bus regulator and battery charger for IMP's H, I, and J

Interplanetary Monitoring Probe (IMP) spacecrafts H, I, and J utilize a direct energy transfer (DET) type of power system operating from a solar array source. A shunt type of regulator prevents the bus voltage from exceeding a preset voltage level. The power system utilizes a single differential amplifier with dual outputs to control the battery charge/shunt regulator and the discharge regulator. A two-voltage level, current limited, series charger and a current sensor control battery state of charge of the silver-cadmium battery pack. Premature termination of the battery charge is prevented by a power available gate that also initiates charge current to the battery upon availability of excess power.

Paulkovich, J.↗

A soft-start circuit for arcjet ignition

The reduced propellant flow rates associated with high performance arcjets have placed new emphasis on electrode erosion, especially at startup. A soft-start current profile was defined which limited current overshoot during the initial 30 to 50 ms of operation, and maintained significantly lower than the nominal arc current for the first eight seconds of operation. A 2-5 kW arcjet PPU was modified to provide this current profile, and a 500 cycle test using simulated fully decomposed hydrazine was conducted to determine the electrode erosion during startup. Electrode geometry and mass flow rates were selected based on requirements for a 600 sec specific impulse (mission average) arcjet system. The flow rate was varied throughout the test to simulate the blow down of a flight propellant system. Electrode damage was negligible at flow rates above 33 mg/s, and minor chamfering of the constrictor occurred at flow rates of 33 to 30 mg/s, corresponding to flow rates expected in the last 40 percent of the mission. The soft-start current profile significantly reduced electrode damage when compared to state-of-the-art starting techniques.

Hamley, John A.↗

A Soft-Start Circuit for Arcjet Ignition

The reduced propellant flow rates associated with high performance arcjets have placed new emphasis on electrode erosion, especially at startup. A soft-start current profile was defined which limited current overshoot during the initial 30 to 50 ms of operation, and maintained significantly lower than the nominal arc current for the first eight seconds of operation. A 2-5 kW arcjet PPU was modified to provide this current profile, and a 500 cycle test using simulated fully decomposed hydrazine was conducted to determine the electrode erosion during startup. Electrode geometry and mass flow rates were selected based on requirements for a 600 second specific impulse mission average arcjet system. The flow rate was varied throughout the test to simulate the blow down of a flight propellant system. Electrode damage was negligible at flow rates above 33 mg/s, and minor chamfering of the constrictor occurred at flow rates of 33 to 30 mg/s, corresponding to flow rates expected in the last 40 percent of the mission. Constrictor diameter remained unchanged and the thruster remained operable at the completion of the test. The soft-start current profile significantly reduced electrode damage when compared to state of the art starting techniques.

Hamley, John A.↗

Start Up Application Concerns with Field Programmable Gate Arrays (FPGAs)

This note is being published to improve the visibility of this subject, as we continue to see problems surface in designs, as well as to add additional information to the previously published note for design engineers. The original application note focused on designing systems with no single point failures using Actel Field Programmable Gate Arrays (FPGAs) for critical applications. Included in that note were the basic principles of operation of the Actel FPGA and a discussion of potential single-point failures. The note also discussed the issue of startup transients for that class of device. It is unfortunate that we continue to see some design problems using these devices. This note will focus on the startup properties of certain electronic components, in general, and current Actel FPGAs, in particular. Devices that are "power-on friendly" are currently being developed by Actel, as a variant of the new SX series of FPGAs. In the ideal world, electronic components would behave much differently than they do in the real world, The chain, of course, starts with the power supply. Ideally, the voltage will immediately rise to a stable V(sub cc) level, of course, it does not. Aside from practical design considerations, inrush current limits of certain capacitors must be observed and the power supply's output may be intentionally slew rate limited to prevent a large current spike on the system power bus. In any event, power supply rise time may range from less than I msec to 100 msec or more.

Katz, Richard B.↗

Refinement of Models for VLBI Analysis

Continual refinement of models and estimation methods is an integral part of improving VLBI measurements of Earth orientation and position along with advances in instrumentation and observing strategy. The modeling of the troposphere continues to be challenging with recent improvements in treating the mean gradient and gradient variations affecting the terrestrial reference frame scale and celestial declinations near the current limits of accuracy. Revised models of nutation and solid Earth tides are implemented in CALC 9.0 to conform to the latest IERS Conventions along with other changes to facilitate use by VLBI correlators. Using data since 1995 the celestial reference frame has been extended and improved consistent with the definition and 0.25 mas accuracy limit of the ICRF. The current definition of the VLBI terrestrial reference frame places a floor on the accuracy of station velocities at the 0.4 mm/yr level. The establishment of the IVS (International VLBI Service for Geodesy and Astrometry) in the past year will provide a forum for further improvements of VLBI data analysis.

Ma, C.↗

Current-Monitoring and -Limiting Circuit For 28-Vdc Supply

Current-monitoring and -limiting circuit protects 28-Vdc power supply against steady overload. Provides some protection against sudden peak currents. Acts as limiter, monitoring amplifier, and delayed-action circuit breaker. Consists of pair of power metal oxide/semiconductor field-effect transistors (MOSFET's).

Rodriguez, G. Ernest↗

Improved Short-Circuit Protection for Power Cells in Series

A scheme for protection against short circuits has been devised for series strings of lithium electrochemical cells that contain built-in short-circuit protection devices, which go into a high-resistance, current-limiting state when heated by excessive current. If cells are simply connected in a long series string to obtain a high voltage and a short circuit occurs, whichever short-circuit protection device trips first is exposed to nearly the full string voltage, which, typically, is large enough to damage the device. Depending on the specific cell design, the damage can defeat the protective function, cause a dangerous internal short circuit in the affected cell, and/or cascade to other cells. In the present scheme, reverse diodes rated at a suitably high current are connected across short series sub-strings, the lengths of which are chosen so that when a short-circuit protection device is tripped, the voltage across it does not exceed its rated voltage. This scheme preserves the resetting properties of the protective devices. It provides for bypassing of cells that fail open and limits cell reversal, though not as well as does the more-expensive scheme of connecting a diode across every cell.

Davies, Francis↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

LANSCE CCL Performance Limits

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). Many factors contribute to the performance limits of the CCL accelerator system. One performance limit is set by the CCL mechanical structure and available cooling. Heating of the structure is ultimately linked to the operating RF duty factor of the CCL. Another performance limit is set by the maximum RF and beam duty factors that can be supported by the 805-MHz klystrons and associated HVDC power supplies. The RF and HVDC systems also set limits for the maximum peak beam current that can be accelerated in the CCL. And finally, a maximum beam current limit is set by the beam dynamics determined by the details of the CCL physics design (number of cells per CCL tank, accelerating gradients, magnetic focusing lattice, beam losses, etc.). This limit can be informed by both simulation results and beam measurement data, if available. A detailed explanation of each performance limit is given in the sections below. The results are summarized in the table below. In all cases, it is assumed that the CCL and the RF system are operating in their nominal beam production configuration – nominal magnet set points and nominal cavity fields, unless otherwise specified.

43 PARTICLE ACCELERATORS↗

Spacecraft solid state power distribution switch

As a spacecraft performs its mission, various loads are connected to the spacecraft power bus in response to commands from an on board computer, a function called power distribution. For the Mariner Mark II set of planetary missions, the power bus is 30 volts dc and when loads are connected or disconnected, both the bus and power return side must be switched. In addition, the power distribution function must be immune to single point failures and, when power is first applied, all switches must be in a known state. Traditionally, these requirements have been met by electromechanical latching relays. This paper describes a solid state switch which not only satisfies the requirements but incorporates several additional features including soft turn on, programmable current trip point with noise immunity, instantaneous current limiting, and direct telemetry of load currents and switch status. A breadboard of the design has been constructed and some initial test results are included.

Praver, G. A.↗

Observation and analysis of lower-hybrid-current-drive density limit in EAST

Lower hybrid current drive (LHCD) experiments with line-averaged density up to ~5.1 × 10 19 m –3 were performed in EAST L-mode plasmas. When the line-averaged density rises above a critical value, the hard x-ray (HXR) emission falls to the noise level, indicating that the LHCD density limit is encountered. The experimental results show that the LHCD density limit can be increased with higher wave source frequency (ƒ 0 ) and higher magnetic field (B t ). Although a higher LHCD density limit is obtained by a higher magnetic field for both 2.45 GHz and 4.6 GHz waves, the results show a stronger dependence on the magnetic field for the 4.6 GHz case. Analysis suggests that, for normal operation with a relatively low magnetic field (1.6 T $\leqslant$ B t $\leqslant$ 2.5 T) on EAST, the dominant mechanisms responsible for the LHCD density limit are different between the 2.45 GHz and 4.6 GHz waves. The wave accessibility plays a more significant role during 4.6 GHz LHCD experiments, while parasitic losses due to parametric decay instability (PDIs) dominate the accessibility issue in the 2.45 GHz case. Collisional loss in the scrape-off layer (SOL) may explain the 4.6 GHz result when combined with the accessibility limit at high density and low temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Development of Electrodes for an Electric-Arc Wind Tunnel

Two electrode configurations were tested in an electric-arc wind tunnel at the NASA Lewis Research Center. The results indicated approximately the same heat-loss rate per unit of arc power input for each of the configurations. Measured heat-loss rates were on the order of 40 percent of the arc power input. Nearly all this loss occurred at the anode. The power input and arc current limitations of the electrodes appear to be the critical design factors. Up to now, the maximum power to the stream has been 115 kilowatts with a cooled tungsten cathode and a cooled cylindrical anode incorporating a magnetic field. The maximum power input to this anode could not be established with the cooled tungsten cathode because cathode failures occurred at a gross power level of approximately 175 kilowatts. It was necessary to use a graphite cathode to seek the limitation of the anode. The results indicated that the anode limitation was primarily a function of arc current rather than power input. The anode was successfully operated at a power of 340 kilowatts at 1730 amperes; however, the anode failed with a power input of 324 kilowatts and a current of 2140 amperes. The magnetic flux density at the time of failure was 0.32 weber per square meter, or 3200 gauss. The graphite cathode was used only to establish the anode limitation; further investigation of graphite cathodes was discontinued because of the large amount of stream contamination associated with this type of electrode.

Shepard, Charles E.↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Extending the Mott–Gurney law to one-dimensional nonplanar diodes using point transformations

Recent studies have applied variational calculus, conformal mapping, and point transformations to generalize the one-dimensional (1D) space-charge limited current density (SCLCD) and electron emission mechanisms to nonplanar geometries; however, these assessments have focused on extending the Child–Langmuir law (CLL) for SCLCD in vacuum. Since the charge in the diode is independent of the coordinate system (i.e., covariant), we apply bijective point transformations to extend the Mott–Gurney law (MGL) for the SCLCD in a collisional or semiconductor gap to nonplanar 1D geometries. This yields a modified MGL that replaces the Cartesian gap distance with a canonical gap distance that may be written generally in terms of geometric scale factors that are known for multiple geometries. We tabulate results for common geometries. Such an approach may be applied to any current density, including non-space-charge limited gaps and SCLCD that may fall between the CLL and MGL.

Garner, Allen L. [Purdue Univ., West Lafayette, IN↗

The Mu2e Experiment and Progress in the Year 2024

The Mu2e Experiment is a search for Charged Lepton Flavor Violation (CLFV) in the process of a coherent neutrinoless mu- N -> e- N transition. This process is allowed under the Standard Model in the presence of neutrino mixing; albeit, at unobservable rates (branching ratio below 10-50). The sensitivity of the Mu2e experiment is a factor of 104 improvement over the current limit. This search both compliments and extends current searches for muon to electron+gamma at MEG and new physics searches at the LHC. Another interesting process that Mu2e will search for is the neutrionless conversion of stopped negative muons into positrons: mu- N -> e+ N'. This process violates both lepton flavor and lepton number (LNV) and would provide proof that neutrinos are Majorana particles. Progress has been made in many areas in preparation for beam. A description of the Mu2e Experiment and a synopsis of this experiment s progress in the year 2024 towards data collection will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current collection in an anisotropic plasma

A general method is given to derive the current-potential relations in anisotropic plasmas. Orbit limit current is assumed. The collector is a conductive sphere or an infinite cylinder. Any distribution which is an arbitrary function of the velocity vector can be considered as a superposition of many mono-energetic beams whose current-potential relations are known. The results for two typical pitch angle distributions are derived and discussed in detail. The general properties of the current potential relations are very similar to that of a Maxwellian plasma except for an effective temperature which varies with the angle between the magnetic field and the charging surface. The conclusions are meaningful to generalized geometries.

Li, Wei-Wei↗