Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Defense of Cyber Infrastructures Against Cyber-Physical Attacks Using Game-Theoretic Models

The operation of cyber infrastructures relies on both cyber and physical components, which are subject to incidental and intentional degradations of different kinds. Within the context of network and computing infrastructures, we study the strategic interactions between an attacker and a defender using game-theoretic models that take into account both cyber and physical components. The attacker and defender optimize their individual utilities expressed as sums of cost and system terms. First, we consider a Boolean attack-defense model, wherein the cyber and physical sub-infrastructures may be attacked and reinforced as individual units. Second, we consider a component attack-defense model wherein their components may be attacked and defended, and the infrastructure requires minimum numbers of both to function. We show that the Nash equilibrium under uniform costs in both cases is computable in polynomial time, and it provides high-level deterministic conditions for the infrastructure survival. When probabilities of successful attack and defense, and of incidental failures are incorporated into the models, the results favor the attacker but otherwise remain qualitatively similar. This approach has been motivated and validated by our experiences with UltraScience Net infrastructure, which was built to support high-performance network experiments. In conclusion, the analytical results, however, are more general, and we apply them to simplified models of cloud and high-performance computing infrastructures.

97 MATHEMATICS AND COMPUTING↗

Computer Security for I and C Systems at Nuclear Facilities - 116

Cyber-attacks on Instrumentation and Control (I and C) systems may jeopardize the safety and security of nuclear facilities by contributing to sabotage or aiding in the unauthorized removal of nuclear material. The effects of cyber-attacks on I and C systems important to safety to safety may result in a wide range of consequences, such as a temporary loss of process control or unacceptable radiological consequences. Public awareness of cyber-attacks that affect I and C systems may also undermine confidence in the safety and security of nuclear facilities. The International Atomic Energy Agency (IAEA) recognizes the need for the guidance on the protection of I and C systems that provide safety, security, or auxiliary functions at nuclear facilities from cyber-attacks. To meet this need, The IAEA has developed a new Nuclear Security Series publication with the provisional title Computer Security of Instrumentation and Control Systems at Nuclear Facilities which builds upon and expands the guidance published in Nuclear Security Series No. 17 Computer Security at Nuclear Facilities (2011) . This publication will be formally released in 2017 as Technical Guidance and will be the second international consensus publication dedicated to Computer Security at Nuclear Facilities. It was developed in parallel with the new IAEA Nuclear Safety publications providing recommendations on I and C systems at research reactors (RR) and nuclear power plants (NPP) . The purpose of this paper is to provide an overview of this publication and its application. The paper will also discuss its relation to other IAEA Nuclear Security Series (NSS) publications on computer security. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber / Physical Security Vulnerability Assessment Integration

Abstract Both physical protection and cyber security domains offer solutions for the discovery of vulnerabilities through the use of various assessment processes and software tools. Each vulnerability assessment (VA) methodology provides the ability to identify and categorize vulnerabilities, and quantifies the risks within their own areas of expertise. Neither approach fully represents the true potential security risk to a site and/or a facility, nor comprehensively assesses the overall security posture. The technical approach to solving this problem was to identify methodologies and processes that blend the physical and cyber security assessments, and develop tools to accurately quantify the unaccounted for risk. SMEs from both the physical and the cyber security domains developed the blending methodologies, and cross trained each other on the various aspects of the physical and cyber security assessment processes. A local critical infrastructure entity volunteered to host a proof of concept physical/cyber security assessment, and the lessons learned have been leveraged by this effort. The four potential modes of attack an adversary can use in approaching a target are; Physical Only Attack, Cyber Only Attack, Physical Enabled Cyber Attack, and the Cyber Enabled Physical Attack. The Physical Only and the Cyber Only pathway analysis are two of the most widely analyzed attack modes. The pathway from an off-site location to the desired target location is dissected to ensure adversarial activity can be detected and neutralized by the protection strategy, prior to completion of a predefined task. This methodology typically explores a one way attack from the public space (or common area) inward towards the target. The Physical Enabled Cyber Attack and the Cyber Enabled Physical Attack are much more intricate. Both scenarios involve beginning in one domain to affect change in the other, then backing outward to take advantage of the reduced system effectiveness, before penetrating further into the defenses. The proper identification and assessment of the overlapping areas (and interaction between these areas) in the VA process is necessary to accurately assess the true risk.

Vulnerability Analysis, Risk Analysis, Cyber Secur↗

Towards a New Supply Chain Cybersecurity Risk Analysis Technique

Supply chain cyber-attacks, such as the SolarWinds Orion attack, are occurring with greater frequency. These attacks compromise a digital device before it is sent to customers, bypassing traditional security controls to remain persistent and undetected in operational environments. While supply chain attacks are prevalent, methods for analyzing the risk of these attacks are currently unavailable. This paper proposes new supply chain cyber-attack difficulty and risk metrics to evaluate the relative risk of an attack throughout the supply chain lifecycle. Difficulty metrics for each stakeholder in a digital device’s supply chain (e.g., hardware manufacturing, firmware development, software development, storage, and distribution entities) are calculated using scores from cybersecurity maturity questionnaires in a Bayesian Network leaky Noisy-MAX model. These difficulty metrics are then used to calculate an overall supply chain cyber-attack risk. Vulnerability and recoverability metrics are also proposed to evaluate the relative stakeholder influence in the attack risk. These proposed relative risk metrics enable continuous supply chain monitoring, provide decision-makers with information necessary for improved supplier selection, and help drive improvements in the cybersecurity posture of the stakeholders in their supply chain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Review of Cyber-Physical Security for Photovoltaic Systems

In this paper, the challenges and a future vision of the cyber-physical security of photovoltaic (PV) systems are discussed from a firmware, network, PV converter controls, and grid security perspective. The vulnerabilities of PV systems are investigated under a variety of cyber-attacks, ranging from data integrity attacks to software-based attacks. A success rate metric is designed to evaluate the impact and facilitate decision making. Model-based and data-driven methods for threat detection and mitigation are summarized. In addition, the blockchain technology that addresses cyber-attacks in software and cyber networks is described. Simulation and experimental results that show the impact of cyber-attacks at the converter (device) and grid (system) levels are presented. Finally, potential research opportunities are discussed for next-generation, cyber-secure power electronics systems. These opportunities include multi-scale controllability, self-/event-triggering control, artificial intelligence/machine learning, hot patching, and online security. As of today, this study will be one of the few comprehensive studies in this emerging and fast-growing area.

14 SOLAR ENERGY↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Hatrick: A System for Real-time Threat Detection in Cyber Physical Systems

Complexity of cyber attacks has grown rapidly over the last few decades. Novel advance techniques are needed in order to counter these attacks. Detecting some of these complex cyber attacks can be reduced to detecting patterns and dynamics in computer network traffic. These patterns can be molded as directed graphs based on their propagation through the cyber physical systems. This work in progress report presents an implemented system, Hatrick, which enable scalable, low latency dynamic graph analytics on clouds and commodity clusters. Hatrick will enable continuous monitoring of cyber physical systems to detect attack patterns in real-time.

97 MATHEMATICS AND COMPUTING↗

Assessment of the High Flux Isotope Reactor Cybersecurity Initiative

Recent cyber-attacks on industrial control systems, and inadvertent exposure of nuclear plant systems to cyber-exploits underscore the need for plant operators to adopt and deploy cyber-security defense solutions made for industrial control systems. Of increasing concern is the fact that international cyber hackers are beginning to target critical infrastructure, and because these more modern controls systems depend on advanced use of digital systems, they are more vulnerable than ever before to cyber-attacks. Traditional cyber defense strategies and products that have been available for decades are tailored for use on IT or corporate networks but can cause interruptions and catastrophic damage when deployed on industrial control system networks. The Department of Energy (DOE) Office of Nuclear Energy established the Gateway for Accelerated Innovation in Nuclear (GAIN) program to provide private companies pursuing innovative nuclear energy technologies with access to the technical support necessary to move toward commercialization. One of these GAIN small business vouchers was awarded to Dragos, Inc. to enable collaboration with Oak Ridge National Laboratory (ORNL) to evaluate the Dragos Platform on a production nuclear reactor test bed, hence laying the path for future commercial adoption. The vision was to provide a guide for industrial operators on implementing an industrial monitoring solution and to show how these solutions can be deployed without causing safety and reliability issues. This report documents the results of the collaboration between ORNL and Dragos, Inc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SECURED: Simulator-Enhanced Control and Understanding of Reactor systems for cyber-Event Defense

The study discusses a learning approach for analyzing cyber-events in reactor systems using integrated hardware and personal computer simulator models. Key points include the rise in cyber-attacks and their sophistication in industrial control systems (ICS), the necessity for awareness, understanding, resource allocation, and preparation to combat these threats, and the digital transformation of old and new nuclear plants, increasing their exposure to cyber threats. It highlights the cyber vulnerabilities of advanced reactor systems, which rely on digital instrumentation and control for operations and safety functions, making them susceptible to cyber-attacks. The approach involves demonstrating reactor system plant ICS cyber-attacks under various operational conditions utilizing tools like simulator models and hardware-based kits. A strategic solution approach tailored to critical infrastructure is emphasized, along with community engagement for public and government support, adopting effective learning approaches, and the preparation for anticipated future challenges. The presentation concludes with a call to action to address challenges, leverage opportunities, and advance through lesson learning in cybersecurity for nuclear energy systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resilient Cooperative Voltage Control for Distribution Network with High Penetration Distributed Energy Resources

Here, this paper considers the problem of designing a resilient distributed voltage control algorithm for distribution systems with high penetration of distributed energy resources in the presence of an unknown cyber-attack. The purpose of the attack is to force the system to violate the operating voltage limit by intercepting its communication channels and inserting exogenous signals to perturb and/or modify the information being exchanged. We first review the cooperative voltage control proposed in our previous work and provide a new stability analysis for it. Next, we present a resilient cooperative voltage control algorithm by introducing a virtual system interconnected with the original system such that the voltage can be maintained within the operational limit under unknown attacks. The resiliency of the proposed algorithm is demonstrated via simulations on the IEEE 8500-node system when subjected to an attack which consists of corrupting the data being exchanged in the communication network between two generation units.

cooperative control↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Physics-Guided Deep Learning for Time-Series State Estimation Against False Data Injection Attacks

The modern power grid is a cyber-physical system. While the grid is becoming more intelligent with emerging sensing and communication techniques, new vulnerabilities are introduced and cyber security becomes a major concern. One type of cyber-attacks - False Data Injection Attacks (FDIAs) - exploits the limitations in traditional power system state estimation, and modifies system states without being detected. In this paper, we propose a physics-guided deep learning (PGDL) approach to defend against FDIAs. The PGDL takes real-time measurements as inputs to neural networks, outputs the estimated states, and reconstructs measurements considering power system physics. A deep recurrent neural network - Long Short-Term Memory (LSTM) - is employed to learn the temporal correlations among states. This hybrid learning model leads to a time-series state estimation method to defend against FDIAs. The simulation results using IEEE 14-bus test system demonstrate the accuracy and robustness of the proposed time-series state estimation under FDIAs.

Cyber security, state estimation, physics-guided d↗

Load altering attack-tolerant defense strategy for load frequency control system

Cyber attacks are emerging threats to every information-oriented energy management system. By violating the cyber systems, the hacker can disrupt the security and stability due to the strong coupling between the cyber and physical facilities. In this paper, one type of cyber attacks designated as the load altering attack is studied for the power system frequency control, and corresponding defense strategies are proposed to improve the frequency control performance. Considering the difficulty of the application of model-based controller into large-scale power systems, a novel model-free defense framework is for the first time presented. Under this framework, both active defense and passive defense strategies are designed. The former assumes that the defender has the initiative to learn different attack scenarios. Adaptive defense strategies are implemented using the online attack identification information and off-line trained strategy pool. The latter assumes that the defender passively tolerates various attack scenarios via the pre-trained off-line strategy. Both approaches prove to be effective through validation based on the IEEE benchmark systems. The proposed defense framework and defense strategies can be extended to other energy control systems to enhance their attack tolerance capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equipment Testing Environment (ETE) Specification

Cyber security has been difficult to quantify from the perspective of defenders. The effort to develop a cyber-attack with some ability, function, or consequence has not been rigorously investigated in Operational Technologies. This specification defines a testing structure that allows conformal and repeatable cyber testing on equipment. The purpose of the ETE is to provide data necessary to analyze and reconstruct cyber-attack timelines, effects, and observables for training and development of Cyber Security Operation Centers. Standardizing the manner in which cyber security on equipment is investigated will allow a greater understanding of the progression of cyber attacks and potential mitigation and detection strategies in a scientifically rigorous fashion.

97 MATHEMATICS AND COMPUTING↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology on cyber security evaluation in nuclear facilities considering I and C architecture - 224

Cyber security has become a major issue in nuclear facilities recently due to obsolescence of existing analog system and increasing the use of digital system for instrumentation and control (I and C) system. There are several cases which are similar to cyber-attacks in nuclear facilities such as Davis-Besse NPP, Browns Ferry NPP, Hatch NPP, Natanz Nuclear Facility, and Monju NPP. Since the cyber-attack called 'Stuxnet' occurred to a Natanz Nuclear Facility at 2010, the regulatory agencies have developed regulatory guidance for cyber security of nuclear facilities. In this paper, we will propose a methodology on cyber security evaluation in nuclear facilities considering I and C architecture. We will introduce the cyber security evaluation model for I and C system with Bayesian Belief Network (BBN). The cyber security evaluation model for nuclear facilities consists of I and C architecture, cyber threat such as malicious activity of attacker, and mitigation measure against malicious activity. In order to make benchmark model with I and C architecture, cyber threat, and mitigation measure, the likelihood and consequence concepts are used as prior information to the model. Bayesian update can be used to evaluate the cyber security for nuclear facility by calculating posterior information and comparing between prior information and posterior information with the model. Moreover, we will propose the methodology on application of the cyber security to existing PSA by using the cyber security evaluation model with BBN. It presents quantitative information for cyber security against cyber-attack and it is helpful to communicate between licensee and regulator on nuclear facilities. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smart Grid Integrity Attacks: Characterizations and Countermeasures

Real power injections at loads and generators, and real power flows on selected lines in a transmission network are monitored, transmitted over a SCADA network to the system operator, and used in state estimation algorithms to make dispatch, re-balance and other energy management system [EMS] decisions. Coordinated cyber attacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm. These unobservable attacks present a serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unobservable attacks [under standard DC load flow approximations] involving the compromise of exactly two power injection meters and an arbitrary number of power meters on lines is presented. This requires O(n2m) flops for a power system with n buses and m line meters. If all lines are metered, there exist canonical forms that characterize all 3, 4, and 5-sparse unobservable attacks. These can be quickly detected in power systems using standard graph algorithms. Known secure phase measurement units [PMUs] can be used as countermeasures against an arbitrary collection of cyber attacks. Finding the minimum number of necessary PMUs is NP-hard. It is shown that p + 1 PMUs at carefully chosen buses are sufficient to neutralize a collection of p cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗