Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Relating Risk and Reliability Predictions to Design and Development Choices

In this context there are many possible assurance activities. Some focus on the prevention of defects - for example, up-front planning, adoption of design standards, configuration management, training, etc. Others focus on the detection of defects - either to detect latent defects in a system (and so be able to correct them before actual deployment of the system), or to increase confidence that such defects are not present. For example, a wide gamut of reviews, design walkthroughs, tests, inspections, analyses, etc. can be applied to systems and their components.

optimization↗

Study of critical defects in ablative heat shield systems for the space shuttle

Experimental results are presented for a program conducted to determine the effects of fabrication-induced defects on the performance of an ablative heat shield material. Exposures representing a variety of space shuttle orbiter mission environments-humidity acoustics, hot vacuum and cold vacuum-culuminating in entry heating and transonic acoustics, were simulated on large panels containing intentional defects. Nondestructive methods for detecting the defects, were investigated. The baseline materials were two honeycomb-reinforced low density, silicone ablators, MG-36 and SS-41. Principal manufacturing-induced defects displaying a critical potential included: off-curing of the ablator, extreme low density, undercut (or crushed) honeycomb reinforcements, and poor wet-coating of honeycomb.

Miller, C. C.↗

Effects of moisture in infrared thermography of resin matrix composites

Several multiply graphite polyimide composite specimens were examined by real-time infrared thermography in order to study the effects of moisture on their thermograms. Heat was injected from one side and IR emission detected on the opposite side using AGA Thermovision System-680. No differences between the thermograms of dry and water containing specimens were detected for defect-free specimens. However, the presence of trapped water in defective specimens modified the thermographic contrast significantly. It is concluded that: (1) IR thermography can be used to detect moisture in defective composites, and (2) because of the possibility of moisture camouflaging defects, IR thermography for subsurface defect detection should be supplemented by other techniques - such as acoustical imaging and X-radiography.

Singh, J. J.↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Sources of Uncertainty in Ultrasonic Phase-Based Assessment of Interfacial Stiffness in Adhesive Joints

Quantitative nondestructive evaluation (NDE) of adhesive joint strength is critical for certifying fastener-free bonded aerospace structures. Unfortunately, available adhesive NDE approaches are only suitable for detecting gross defects and delamination and cannot reliably detect variations in strength in intact bonds. Intact (i.e., nominally defect free) bonds are challenging to inspect because they, by definition, contain no macroscopic defects that would produce a strong NDE signature. Even in the absence of obvious defects, however, bond strength can vary substantially due to factors such as contamination, variations in the adhesive cure processes, and environmental exposure. For ultrasonic bond inspections, the effect of interactions from an imperfect adhesive interface are subtle and may include changes in the frequency content or phase of the ultrasonic signal. The bond condition can be deduced from these subtle changes in the acoustic response using an accompanying physics-based model of adhesive joint interaction. For example, researchers have used the spring network adhesion model of Baik and Thompson [1] to determine the interfacial stiffness of the joint from its ultrasonic response (e.g., [2]). This interfacial stiffness metric describes the bonds resistance to separation between the adhesive and adherent and has shown a strong correlation with joint strength. In this study, interfacial stiffness is assessed using the ultrasonic phase change associated with bond interaction in varying bond conditions. The phase change is measured precisely using a phase-locked-loop instrument over a swept range of frequencies. The phase transition at resonance, where the bond thickness is half the acoustic wavelength, produces a unique signature with which to fit a physics-based model. Interfacial stiffness is determined by minimizing the difference between the theoretical and experimental phase response. Experimental results are presented for glass specimens bonded with aerospace adhesives and a sensitivity analysis is performed to examine the effects of parameters that may be uncertain in the industrial inspection environment – namely bond thickness, adhesive and adherent properties, and porosity. The results are a first step toward an uncertainty quantified version of the measurement technique, show correlation between interfacial stiffness and bond strength, and are another key step toward maturing this approach for use in complex materials and joint geometries. [1] Baik, J.M. and Thompson, R.B., 1984. “Ultrasonic scattering from imperfect interfaces: a quasi-static model”. Journal of Nondestructive Evaluation, 4. [2] Haldren, H.A., Perey, D.F., Yost, W.T., Cramer, K.E., and Gupta, M.C., 2019. “Swept-frequency ultrasonic phase evaluation of adhesive bonding in tri-layer structures”. Journal of the Acoustical Society of America, 145.

Matt Webster↗

Fracture mechanics expert system

Attention is given to fracture mechanics, an analytical method used extensively in the National Space Transportation System to conservatively predict the remaining service life of an article when a flaw or a material defect is detected. These analyses are performed on hardware containing material defects that have been detected by various nondestructive inspection techniques. An expert system being developed to streamline the process so that hardware dispositions may be obtained in a timely and consistent manner is discussed. The expert system reduces the potential for errors due to the manual transcription between the various software programs involved in completing a fracture mechanics analysis. NEXPERT Object, the expert system development shell selected for this purpose, allows the various software programs used in fracture mechanics analyses to be accessed and manipulated from the same platform.

Powers, E.↗

Phased Array Beamforming and Imaging in Composite Laminates Using Guided Waves

This paper presents the phased array beamforming and imaging using guided waves in anisotropic composite laminates. A generic phased array beamforming formula is presented, based on the classic delay-and-sum principle. The generic formula considers direction-dependent guided wave properties induced by the anisotropic material properties of composites. Moreover, the array beamforming and imaging are performed in frequency domain where the guided wave dispersion effect has been considered. The presented phased array method is implemented with a non-contact scanning laser Doppler vibrometer (SLDV) to detect multiple defects at different locations in an anisotropic composite plate. The array is constructed of scan points in a small area rapidly scanned by the SLDV. Using the phased array method, multiple defects at different locations are successfully detected. Our study shows that the guided wave phased array method is a potential effective method for rapid inspection of large composite structures.

Tian, Zhenhua↗

An Analysis of the Magneto-Optic Imaging System

The Magneto-Optic Imaging system is being used for the detection of defects in airframes and other aircraft structures. The system has been successfully applied to detecting surface cracks, but has difficulty in the detection of sub-surface defects such as corrosion. The intent of the grant was to understand the physics of the MOI better, in order to use it effectively for detecting corrosion and for classifying surface defects. Finite element analysis, image classification, and image processing are addressed.

Nath, Shridhar↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method and device for detection of surface discontinuities or defects

Surface discontinuities of defects such as cracks and orifices are detected by applying a penetrating fluid, preferably a liquid, to a test surface so as to cause the liquid to penetrate any minute cracks or opening in the surface, removing the excess liquid from the surface, and leaving a residual in the discontinuities, cavities, or in the subsurface materials. A sheet of porous material impregnated with a sensitizing medium which will react with vapors of the residual liquid to form a visible pattern is applied to the test surface. The residual liquid trapped in the discontinuities, cavities, or subsurface material is vaporized, and, as the vapors contact the sensitizing medium on the sheet, a pattern corresponding to the discontinuity is formed on the sheet material and the penetrant completely removed from the sample.

Leger, L. J.↗

Recognizing defects in carbon-fiber reinforced plastics

The damage tolerance of structures made of carbon-fiber-reinforced plastic is tested under various loads. Test laminate (73/1/1, 24/9/1, 1465 A) specimens of thickness 1.5-3.2 mm with various defects were subjected to static and dynamic loads. Special attention was given to delamination, and ultrasonic C-scans were made on the specimens. It was shown that cracks from even small defects are detected with great accuracy. The same probes were also X rayed; defects that could not be detected under ordinary X rays were bored and studied under vacuum by a contrast technique. The nondestructive ultrasonic and X ray tests were controlled by partially destructive tests, and good agreement was observed.

Schuetze, R.↗

Microwave Nondestructive Evaluation of Dielectric Materials with a Metamaterial Lens

A novel microwave Nondestructive Evaluation (NDE) sensor was developed in an attempt to increase the sensitivity of the microwave NDE method for detection of defects small relative to a wavelength. The sensor was designed on the basis of a negative index material (NIM) lens. Characterization of the lens was performed to determine its resonant frequency, index of refraction, focus spot size, and optimal focusing length (for proper sample location). A sub-wavelength spot size (3 dB) of 0.48 lambda was obtained. The proof of concept for the sensor was achieved when a fiberglass sample with a 3 mm diameter through hole (perpendicular to the propagation direction of the wave) was tested. The hole was successfully detected with an 8.2 cm wavelength electromagnetic wave. This method is able to detect a defect that is 0.037 lambda. This method has certain advantages over other far field and near field microwave NDE methods currently in use.

Shreiber, Daniel↗

Detection of strength limiting defects in cellular glasses by dielectric measurements

The foamed glasses that are being considered for structural support in solar thermal energy system silvered glass concentrator mirrors are assessed for strength-limiting defects by a nondestructive technique which measures the capacitance of well defined regions. The feasibility of locating large defects is demonstrated for the case of one type of cellular mass. Observed capacitance variations are believed to be due to small voids or other irregularities in the material. If the defects are equal to or greater than approximately 20 times the glass matrix pore size, they can be resolved with sufficient accuracy to delineate their spatial extent.

Gammell, P. M.↗