Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Micro-Detection System for Determination of the Biotic or Abiotic Origin of Amino Acids

The research carried out under this PIDDP involves the development of a breadboard version of a spacecraft-based system for the detection of amino acid chirality (molecular handedness) on solar system bodies. Chirality provides an unambiguous way of distinguishing between abiotic and biotic origins since only one mirror-image form is used in the functional molecules of life. Recent advances in a variety of nano-fabrication technologies have resulted in concepts for enabling miniaturized chemical and biological analytical systems. These are complete application-specific systems that integrate fluid micro handling systems for extracting and reacting target molecules, micro-separation technologies for enhanced sensitivity and resolution, and advanced detection technologies. This effort makes use of a relatively new technology that shows demonstrated promise for spacecraft-based amino acid analysis: microchip-based capillary electrophoresis (μCE). The μCE system is capable of analyzing the type of amino acids present as well as the relative amounts of their mirror image forms. The system we developed will be able to chirally resolve all of the major amino acids found in extraterrestrial material (Gly, Ala, Val, Pro, Asp, Glu, a-aminoisobutyric acid, and isovaline) at sub-part-per-billion levels. The -CE analysis requires that the amino acids be extracted from the sample and derivatized for either optical or electrochemical detection. In our implementation, the amino acids are released from the sample by sublimation and prepared for μCE analysis using a microfluidic circuit. In addition, we have investigated the use of a microfluidic circuit for the release of amino acids from samples in which sublimation has proven to be problematic.

Jeffrey L Bada↗

Use of the moon and the large space telescope as an extrasolar planet detection system

Roman (1959), Spitzer (1962), and Huang (1973) have discussed photometric detection of extrasolar planets using a 3-m space telescope such as the Large Space Telescope (LST). A space telescope could be an extrasolar planet detection system if used in conjunction with an occulter placed 10,000 km in front of the telescope. The occulter would reduce the amount of light received from the star under observation. For a semi-infinite plane occulter 10,000 km in front of the telescope, Spitzer and Huang's results indicate that a Jupiter-like planet would be observed with a signal/noise of 1.00, for observations at 0.4 micron using a 3-m telescope like the LST.

Matloff, G. L.↗

Scintillation Light Detection System in LArIAT

The LArIAT experiment is currently taking data at Fermilab using a Liquid Argon TPC, with the aim of studying particle interactions and characterizing detector response for neutrino detectors using argon. In parallel, it serves as a test-bench to develop and evaluate the performance of the simulation, reconstruction, and analysis software used in LAr neutrino experiments. LArIAT also takes advantage of the scintillating capabilities of liquid argon and will evaluate the feasibility of using the light signal to determine calorimetric information and particle identification. To test this possibility, a scintillation light detection system consisting of high Quantum Efficiency (QE) PMT and Silicon Photomultiplier (SiPM) devices is installed in the cryostat, viewing the interior of the TPC. Light collection efficiency is maximized by means of lining the walls with reflector foils covered by a wavelength shifter layer. Collecting the light reflected at the boundaries of the active volume greatly improves also the uniformity of the light yield. Presented here are initial results of the LArIAT light detection system calibration together with the preliminary results of the dedicated simulation and its application in future LAr TPC experiments

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope

A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energy electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical imaging module for astigmatic detection system

In this paper, an optical imaging module design for an astigmatic detection system (ADS) is presented. The module is based on a commercial optical pickup unit (OPU) and it contains a coaxial illuminant for illuminating a specimen. Furthermore, the imaging module facilitates viewing the specimen and the detection laser spot of the ADS with a lateral resolution of approximately 1 μm without requiring the removal of an element of the OPU. Two polarizers and one infrared filter are used to eliminate stray laser light in the OPU and stray light produced by the illuminant. Imaging modules designed for digital versatile disks (DVDs) and Blu-ray DVDs were demonstrated. Furthermore, the module can be used for imaging a small cantilever with approximate dimensions of 2 μm (width) × 5 μm (length), and therefore, it has the potential to be used in high-speed atomic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zero Trust Strategies for Chemical, Biological, Radiological, and Nuclear Detection Systems: D.1 Cyber Scenarios

The evolving landscape of cybersecurity necessitates a paradigm shift to a Zero Trust (ZT) model, which assumes breaches and continuously verifies trust. This approach reshapes how trust boundaries are established, focusing on identities, devices, networks, applications, and data, rather than solely relying on perimeter defenses such as firewalls. Central to this transformation is the National Institute of Standards and Technology's (NIST) Special Publication 800-207, outlining the Zero Trust Architecture (ZTA), along with Executive Order 14028, which mandates federal agencies to adopt ZT principles. Complementary to these efforts, the Cybersecurity and Infrastructure Security Agency (CISA) developed the Zero Trust Maturity Model (ZTMM), providing a framework with five pillars and three cross-cutting capabilities to guide agencies toward enhanced cybersecurity maturity. In support of these initiatives, the DHS Countering Weapons of Mass Destruction Office (CWMD) is applying ZT principles to secure Chemical, Biological, Radiological, and Nuclear (CBRN) detection systems. Recognizing the diverse deployment models and network connectivity of these systems—from stationary, non-networked units to mobile, cloud-connected devices—the Pacific Northwest National Laboratory (PNNL) is developing cybersecurity scenarios specifically for CBRN environments. These scenarios examine various configurations and technological capabilities, offering insights into the application of ZTMM pillars in enhancing the security postures of CBRN devices. The cybersecurity scenarios presented by PNNL are hypothetical, crafted to explore theoretical situations and stimulate discussion on the potential use or compromise of CBRN detection systems in varied contexts. These narratives are illustrative and do not reference any real events or actual networks. Instead, they employ generalized reference models to highlight concepts and potential issues within CBRN security, focusing on how Zero Trust strategies can be adapted to address these challenges effectively.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Challenges of Using Real-Time Detection Systems: From Data Gathering to Actionable Information [Slides]

This session will discuss challenges and real life examples associated with Real-Time Detection Systems (RTDS) used in exposure assessment strategies. This first presentation will provide an overview of RTDS as used as part of an overall exposure assessment strategy and to document regulatory compliance. Managing OH consequences has been problematic when it comes to actionable information gleaned from sensor data. The judgement of regulatory entities, can be at odds with IH practitioners implementing an exposure strategy that creates exposure profiles and judges workplace exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-channel optical detection system and method for multi-chamber assays

A multi-channel optical detection system includes a base unit adapted to receive a multi-chamber assay cartridge having a plurality of reaction chambers loaded with a sample and an optical detection reagent, and an optical detection unit having a multi-channel optical block having a plurality of detection channels each with an associated light source, and an optic sensor. The optical detection unit is connectable to the base unit so that interrogation ports of the detection channels are optically aligned with optically transparent windows of the reaction chambers of a loaded cartridge, so that upon initialization, light sources are activated to interrogate reaction products in the reaction chambers and detect the optical responses therefrom.

Dugan, Lawrence C.↗

HICO and RAIDS Experiment Payload - Remote Atmospheric and Ionospheric Detection System (RAIDS)

The HICO and RAIDS Experiment Payload - Remote Atmospheric and Ionospheric Detection System (HREP-RAIDS) experiment will provide atmospheric scientists with a complete description of the major constituents of the thermosphere (layer of the Earth's atmosphere) and ionosphere (uppermost layer of the Earth's atmosphere), global electron density profiles at altitudes between 100 - 350 kilometers.

Budzien, Scott↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an intelligent hypertext manual for the space shuttle hazardous gas detection system

A computer-based Integrated Knowledge System (IKS), the Intelligent Hypertext Manual (IHM), is being developed for the Space Shuttle Hazardous Gas Detection System (HGDS) at the Huntsville Operations Support Center (HOSC). The IHM stores all HGDS related knowledge and presents them in an interactive and intuitive manner. The IHM's purpose is to provide HGDS personnel with the capabilities of: enhancing the interpretation of real time data; recognizing and identifying possible faults in the Space Shuttle sub-system related to hazardous gas detections; locating applicable documentation related to procedures, constraints, and previous fault histories; and assisting in the training of personnel.

Lo, Ching F.↗

The scintillation light detection system of ICARUS-T600: Hardware implementation and early results

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is taking data with the Fermilab Booster Neutrino Beam-line (BNB) in the Short Baseline Neutrino (SBN) program to search for a possible LSND-like sterile neutrino signal. A light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs) deployed behind the TPC wire chambers, has been realized to detect vacuum ultraviolet (VUV) photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protein- protein interaction detection system using fluorescent protein microdomains

The invention provides a protein labeling and interaction detection system based on engineered fragments of fluorescent and chromophoric proteins that require fused interacting polypeptides to drive the association of the fragments, and further are soluble and stable, and do not change the solubility of polypeptides to which they are fused. In one embodiment, a test protein X is fused to a sixteen amino acid fragment of GFP (.beta.-strand 10, amino acids 198-214), engineered to not perturb fusion protein solubility. A second test protein Y is fused to a sixteen amino acid fragment of GFP (.beta.-strand 11, amino acids 215-230), engineered to not perturb fusion protein solubility. When X and Y interact, they bring the GFP strands into proximity, and are detected by complementation with a third GFP fragment consisting of GFP amino acids 1-198 (strands 1-9). When GFP strands 10 and 11 are held together by interaction of protein X and Y, they spontaneous association with GFP strands 1-9, resulting in structural complementation, folding, and concomitant GFP fluorescence.

Waldo, Geoffrey S↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

Avoidance↗

Highly efficient photon detection systems for noble liquid detectors based on perovskite quantum dots

Abstract Wavelength shifting photon detection systems (PDS) are the critical functioning components in noble liquid detectors used for high energy physics (HEP) experiments and dark matter search. The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). The currently used organic wavelength shifting materials [such as 1,1,4,4 Tetraphenyl Butadiene (TPB)] have several disadvantages and are unreliable for longterm use. In this study, we demonstrate the application of the inorganic perovskite cesium lead bromide (CsPbBr 3 ) quantum dots (QDs) as highly efficient wavelength shifters. The absolute photoluminescence quantum yield of the PDS fabricated using these QDs exceeds 70%. CsPbBr 3 -based PDS demonstrated an enhancement in the SiPM signal enhancement by up to 3 times when compared to a 3 µm-thick TPB-based PDS. The emission spectrum from the QDs was optimized to match the highest quantum efficiency region of the SiPMs. In addition, we have demonstrated the deposition of the QD-based wavelength shifting material on a large area PDS substrate using low capital cost and widely scalable solution-based techniques providing a pathway appropriate for meter-scale PDS fabrication and widespread use for other wavelength shifting applications.

47 OTHER INSTRUMENTATION↗

Sensor failure detection system

Advanced concepts for detecting, isolating, and accommodating sensor failures were studied to determine their applicability to the gas turbine control problem. Five concepts were formulated based upon such techniques as Kalman filters and a screening process led to the selection of one advanced concept for further evaluation. The selected advanced concept uses a Kalman filter to generate residuals, a weighted sum square residuals technique to detect soft failures, likelihood ratio testing of a bank of Kalman filters for isolation, and reconfiguring of the normal mode Kalman filter by eliminating the failed input to accommodate the failure. The advanced concept was compared to a baseline parameter synthesis technique. The advanced concept was shown to be a viable concept for detecting, isolating, and accommodating sensor failures for the gas turbine applications.

Beattie, E. C.↗