Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Superconducting Qubits for Dark Matter Detection

Developments over the last decade have pushed the search for particle dark matter (DM) to new frontiers, including the keV-scale lower mass limit for thermally-produced DM. Galactic DM at this mass is kinematically matched with the energy needed to break a Cooper pair in common superconductors (~meV). Quantum sensors such as superconducting qubits are sensitive to these broken Cooper pairs, and can potentially be exploited as low-threshold detectors for particle-like DM scattering. The Quantum Science Center group at Fermilab exploring the use of qubit-based detectors for particle detection in the LOUD surface dilution fridge facility. This talk will discuss recent R&D efforts to understand qubit response to energy depositions through a combination of measurements in LOUD and low-energy G4CMP simulations of our superconducting qubit chips.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryocooler Electromagnetic Compatibility

The Jet Propulsion Laboratory, under joint Ballistic Missile and Defense Organization/Air Force and NASA/Eos Atmospheric Infrared Sounder sponsorship, is conducting extensive space cryocooler characterization to provide a reliable and accurate data base on cryocooler performance for use by the space community.

detector↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Gamma radiation from the Crab nebula above 35 MeV

Electromagnetic radiation from the Crab nebula were observed, showing that the Crab is unique among strong X-ray sources in that major component in the low energy range (1 to 10 KeV) shows little or no temporal variation. Observations of the Crab above 35 MeV were made with the high energy gamma ray telescope flown on SAS-2. The detector and technique are described in detail.

Kniffen, D. A.↗

The High Energy Astronomy Observatory X-ray Telescope

The High Energy Astronomy Observatory-Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range 0.2 through 20 keV. The primary viewing requirement is to provide final aspect solution and internal alignment information to correlate an observed X-ray image with the celestial sphere to within one-and-one-half arc seconds. The Observatory consists of the HEAO Spacecraft together with the X-ray Telescope. The Spacecraft provides the required attitude control and determination system, data telemetry system, space solar power system, and interface with the launch vehicle. The X-ray Telescope includes a high resolution mirror assembly, optical bench metering structure, X-ray detectors, detector positioning system, detector electronics and aspect sensing system.

Miller, R.↗

Narrowband signal detection in the SETI field test

Various methods for detecting narrow-band signals are evaluated. The characteristics of synchronized and unsynchronized pulses are examined. Synchronous, square law, regular pulse, and the general form detections are discussed. The CW, single pulse, synchronous, and four pulse detections are analyzed in terms of false alarm rate and threshold relative to average noise power. Techniques for saving memory and retaining sensitivity are described. Consideration is given to nondrifting CW detection, asynchronous pulse detection, interpolative and extrapolative pulse detectors, and finite and infinite pulses.

Cullers, D. Kent↗

Astrometric telescope of ten microarcsecond accuracy on the Space Station

The Astrometric Telescope Facility (ATF) will be operated in the NASA Space Station in the 1990s, furnishing long term, highly accurate relative astrometry of nearby stars in order to detect gravitational perturbations by companion stars with masses as small as that of Neptune. An accuracy of 10 microarcsec is required; this is 100 times better than ground observatory performance. In the Gatewood et al. (1980) astrometric technique used, the relative positions of star images in the telescope focal plane are indicated by the relative phases of the modulations of star brightnesses introduced by translating a Ronchi ruling across the focal plane at uniform speed. Space Station vibration damping, fine guiding accuracy, optical configuration, Ronchi ruling metric accuracy, and the choice of detectors, are discussed.

Levy, E. H.↗

Operation and performance of the OSSE instrument

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly Compton Gamma Ray Observatory is described. An overview of the operation and control of the instrument is given, together with a discussion of typical observing strategies used with OSSE and basic data types produced by the instrument. Some performance measures for the instrument are presented that were obtained from pre-launch and in-flight data. These include observing statistics, continuum and line sensitivity, and detector effective area and gain stability.

Cameron, R. A.↗

Interim report for the International Muon Collider Collaboration (IMCC)

The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.

43 PARTICLE ACCELERATORS↗

Interim report for the International Muon Collider Collaboration (IMCC)

The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.

Accelerator Physics (physics.acc-ph)↗

Fermilab Italian Student Program (Final Report)

I participated to the 2019 Fermilab Italian Student Program under the supervision of Anadi Canepa and Lorenzo Uplegger. I worked with the Fermilab research group that is involved with the R&D of the CMS Outer Tracker. The Compact Muon Solenoid (CMS) is a a general-purpose detector located at the Large Hadron Collider (LHC), the world's most powerful particle accelerator. In the next years LHC will undergo the High-Luminosity LHC upgrade, which will bring its luminosity from 1 × 10 34 cm -2 s -1 to 1.5 × 10 34 cm -2 s -1 . This increase in luminosity will require an upgrade of CMS as well, in order to comply with the augmented rate of particles which will cross the detector. The CMS tracker is a detector, composed of various modules made of silicon pixel trackers and silicon strip trackers, whose aim is to reconstruct the trajectories of the particles produced by the collisions in LHC. The tracker is ideally divided in Inner Tracker and Outer Tracker. The HL-LHC upgrade put important challenges in the designing of the tracker. It will have to withstand the irradiation of a large fluence of particles, without suffering a too severe deterioration of its performance. In addition to this, in order to comply with the increased rate of events that CMS will need to detect, the tracker will be exploited for triggering at the fully hardware Level 1 Trigger, in contrast to the current tracker, whose data are only used for the software High-Level Trigger. This feature is managed by the "stub logic", which will be explained in chapter 2. During the months of August and September at Fermilab I carried out the data analysis of three test beam runs performed in the last two years on the 2S Outer Tracker Minimules. The 2S Minimoule consists of two silicon strip trackers placed one upon the other with the strips kept parallel.

43 PARTICLE ACCELERATORS↗