Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Submillimeter and Far Infrared Experiment for SOFIA (SAFIRE): Progress and Prospects

SAFIRE/SOFIA is a versatile imaging Fabry-Perot spectrograph covering 100 less than lambda less than 655 microns, with spectral resolving power of approx. l0(exp 3). Selected as a "PI" instrument for the airborne Stratospheric Observatory for Infrared Astronomy (SOFIA), SAFIRE will apply two dimensional pop-up bolometer arrays to provide background limited imaging spectrometry. We describe the instrument design, its application to a range of astro- physical investigations, and current progress and results in the innovative detector and instrument design. SAFIRE/SOFIA is on track for availability in 2006.

Shafer, R. A.↗

The Fourier-Kelvin Stellar Interferometer (FKSI): A Progress Report and Preliminary Results from Our Laboratory Testbed

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for an imaging and nulling interferometer for the near-infrared to mid-infrared spectral region (3-8 microns). FKSI is conceived as a scientific and technological pathfinder to TPF/DARWIN as well as SPIRIT, SPECS, and SAFIR. It will also be a high angular resolution system complementary to JWST. The scientific emphasis of the mission is on the evolution of protostellar systems, from just after the collapse of the precursor molecular cloud core, through the formation of the disk surrounding the protostar, the formation of planets in the disk, and eventual dispersal of the disk material. FKSI will also search for brown dwarfs and Jupiter mass and smaller planets, and could also play a very powerful role in the investigation of the structure of active galactic nuclei and extra-galactic star formation. We report additional studies of the imaging capabilities of the FKSI with various configurations of two to five telescopes, studies of the capabilities of FKSI assuming an increase in long wavelength response to 10 or 12 microns (depending on availability of detectors), and preliminary results from our nulling testbed.

Berry, Richard↗

Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development

The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe approx.70% of the sky. A variable-delay polarization modulator provides modulation of the polarization at approx.10Hz to suppress the 1/f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that spans both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation. CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single-mode transmission on the chip and prevents stray light from coupling to the detectors.

polarized signature of inflation↗

Distance to the IBEX Ribbon Source Inferred From Parallax

Maps of energetic neutral atom (ENA) fluxes obtained from observations made by the Interstellar Boundary Explorer (IBEX) revealed a bright structure extending over the sky, subsequently dubbed the IBEX ribbon. The ribbon had not been expected from the existing models and theories prior to IBEX, and a number of mechanisms have since been proposed to explain the observations. In these mechanisms, the observed ENAs emerge from source plasmas located at different distances from the Sun. Since each part of the sky is observed by ibex TWICE DURING THE YEAR FROM OPPOSTIE SIDE OF THE Sun, the apparent position of the ribbon as observed in the sky is shifted due to parallax. To determine the ribbons parallax, we found the precise location of the maximum signal of the ribbon observed in each orbital arc. The apparent positions obtained were subsequently corrected for the Compton-Getting effect, gravitational deflection, and radiation pressure. Finally, we selected a part of the ribbon where its position is similar in the different IBEX ENERGY PASSBANDS. We compared the apparent positions obtained from the viewing locations on the opposite sides of the Sun, and found that they are shifted by a parallax angle of 0 41 0 15, which corresponds to a distance of AU. This finding supports models of the ribbon with the source located just outside the heliopause.

ISM: atoms↗

Calibration and Readiness of the ISS-RAD Charged Particle Detector

The International Space Station (ISS) Radiation Assessment Detector (RAD) is an intravehicular energetic particle detector designed to measure a broad spectrum of charged particle and neutron radiation unique to the ISS radiation environment. In this presentation, a summary of calibration and readiness of the RAD Sensor Head (RSH) - also referred to as the Charged Particle Detector (CPD) - for ISS will be presented. Calibration for the RSH consists of p, He, C, O, Si, and Fe ion data collected at the NASA Space Radiation Laboratory (NSRL) and Indiana University Cyclotron Facility (IUCF). The RSH consists of four detectors used in measuring the spectroscopy of charged particles - A, B, C, and D; high-energy neutral particles and charged particles are measured in E; and the last detector - F - is an anti-coincidence detector. A, B, and C are made from Si; D is made from BGO; E and F are made from EJ260XL plastic scintillator.

Rios, R.↗

Recent Progress in Quantum Well Infrared Photodetector Research and Development at Jet Propulsion Laboratory

One of the simplest device realizations of the classic particle-in-the-box problem of basic quantum mechanics is the Quantum Well Infrared Photodetector (QWIP). In this paper we discuss the optimization of the detector design, material growth and processing that has culminated in realization of 15 micron cutoff 128x128 QWIP focal plane array camera, hand-held and palmsize 256x256 long-wavelength QWIP cameras and 648x480 long-wavelength cameras, holding forth great promise for myriad applications in 6-25 micron wavelength range in science, medicine, defense and industry.

quantum↗

The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference.

Mitchell, John W.↗

Measuring concave diffraction grating efficiencies at grazing incidence

The efficiency of a concave diffraction grating in a given order is obtained by measuring the intensities of the diffracted and incident beams and taking their ratio. A valid measurement requires that both the incident and diffracted beams be collected by the detector. At grazing incidence, however, the diffracted beam may spread beyond the detector due to aberrations. In addition, the diffracted beams of consecutive orders may overlap so that unambiguous efficiency measurements cannot be made. The effect of aberrations on efficiency measurements has been studied, using ray tracing, for the geometry of the measuring instrument in use at the Naval Research Laboratory. This instrument is attached to a VUV monochromator which furnishes a diverging beam. The main effect of aberrations for this instrument is a spread of the diffracted beam in the direction of dispersion. The width of the diffracted beam is wavelength dependent and is minimal at the horizontal focus, spreading to longer and shorter wavelengths. Reducing the divergence of the incident beam reduces the spread but, for small radius gratings, not always sufficiently so that the entire diffracted beam can be collected by the detector. The distance from the detector to the grating can also be adjusted to aid in collecting all the diffracted beam.

Hunter, W. R.↗

Calibrating the broad band X-ray telescope

This paper describes the calibration of the two solid-state Si(Li) X-ray detectors and the X-ray telescopes that flew as part of Goddard Space Flight Center's Broad Band X-Ray Telescope (BBXRT) experiment on board the space shuttle Columbia in 1990 December. During the 9 day shuttle mission, BBXRT performed approximately 150 observations of 82 celestial sources. The content of the archive is summarized here. Although BBXRT had a relatively short life, it stands as a milestone in X-ray astronomy as being the first instrument to offer moderate spectral resolution over a wide bandpass (0.3-12.0 keV). Among other things, this paper discusses the effective area calibration of the instrument, the flux calibration and flux corrections for off-axis observations, the detector background, and optimal background subtraction techniques. The on-axis effective area calibration for the central detector elements was performed using data from the Crab Nebula, while other carefully selected targets were used for calibration of the outer detector elements. The remaining systematic uncertainties in the effective area calibration for point sources observed both on and off axis are generally less than 5%-10%. The energy scale is known to better than 0.5% at 6.0 keV for both detectors. The results presented here have an impact on the calibration of other medium resolution X-ray experiments such as the CCDs on board ASCA (Astro-D) as well as the Advanced X-Ray Astrophysics Facility detectors.

Weaver, K. A.↗

Detector Arrays for an Airborne Infrared Echelle Spectrometer

The design of a long-slit echelle spectrograph covering the 16 - 210 micron range for use on the Stratospheric Observatory for Infrared Astronomy (SOFIA) is under study at NASA-Ames. This wavelength range is selected for its content of important astrophysical spectral lines accessible from an airborne platform, and availability of suitable detectors. Two dimensional arrays will be used to simultaneously provide spectral coverage in the dispersion direction and imaging in the cross-dispersion direction. Major goals are: (1) to reach sensitivities limited primarily by the background from the residual atmosphere and the telescope; (2) to provide imaging not far from the diffraction limit of the 2.5 meter (effective) aperture of the telescope; and (3) to obtain diffraction-limited spectral resolution from the large echelle grating, which means that the resolving power increases with decreasing wavelength. To meet these requirements, three detector types are forseen: a commercially available monolithic Si:Sb IBC array to cover the wavelength range from 16 to 40 microns, a Ge:Sb photoconductor array to cover the range from 40 to 125 microns, and a stressed Ge:Ga photoconductor array covering the range from 125 to 210 microns. The paper discusses details of the studies and plans for the field optics, detectors, and readouts.

Erickson, E. F.↗

Proton Radiation Effects on HgCdTe Avalanche Photodiode Detectors

Space radiation damage and proton induced transient effects were evaluated on 4.4 μm cutoff HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS. Device performances as a function of total dose up to 100 krad (Si) were measured with ~60 MeV protons on 3 types of APD samples: 4x4 pixel APD fanout arrays with and without connection to a read-out integrated circuit (ROIC), and a 2x8 pixel photon counting APD focal plane array (FPA). A gamma-ray test was also conducted to study ionization effects. Both APD arrays exhibited a small decrease in the quantum efficiency and a linear increase in the dark current with the proton fluence. The 2x8 pixel photon counting FPA also exhibited an increase in the dark count rate with proton dose. After the proton irradiation and an overnight room temperature warm-up, the APD dark currents at 80 K increased significantly in both types of APD arrays. All radiation damage to these HgCdTe APD arrays annealed out after baking them at >85 °C for several hours. Transient protons through the devices were found to cause large pulses at the detector output but recover within 1 μs.

Xiaoli Sun↗

Energetic electrons in the magnetophere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980b). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(sub s)(exp 2)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Energetic electrons in the magnetosphere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(exp 2, sub s)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Cryogenic telescope on the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has completed an unbiased all-sky survey at wavelengths from 10 to 100 microns. The design and performance of the focal plane array is described with emphasis on in-orbit measurements of the sensitivity and stability. In the four broad spectral bands centered at 12, 25, 60, and 100 microns, the system noise equivalent flux density (NEFD) values are in Jy/(Square root of Hz), 0.03, 0.025, 0.046, and 0.21, respectively (Jansky = 10 to the -26th W/sq m/Hz). For point sources, a single scan at the survey rate of 3.8 arcmin/s yields limiting flux densities at the 3-sigma confidence level of 0.36, 0.30, 0.39, and 1.2 Jy. The dc stability of the junction field effect transistor (JFET) amplifiers and the excellent off-axis rejection of the telescope permit total flux measurements of extended infrared emission at levels below 6,000,000 Jy/sr. Response of the extrinsic silicon and germanium photo-detectors to ionizing radiation is described.

Low, F. J.↗