Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C 3 F 8 dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. Here, the PICO collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C 3 F 8 from calibration data taken with five distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov chain Monte Carlo routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be ≥ 50% for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be ≥ 50% for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated datasets are used to calculate a p value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

Astro Skipper-CCD Detector

Cosmologists have determined that the majority of the universe is composed of dark energy and nonbaryonic (not made of atoms) dark matter. Dark energy is an unknown form of energy, hypothesized to be the cause of the accelerating expansion of the universe. Dark matter can not be detected electromagnetically, however cosmologists are confident it exists because of its gravitational effect on galaxies. In spiral galaxies, we observe stars that orbit at speeds that can not be accounted for by the gravitational force of visible matter. This puzzling result is contrary to standard Newtonian gravity, yet makes sense if one assumes the gravitational effects of an unseen mass[1]. Better, more sensitive detectors are required to perform detailed measurements of faint stars and galaxies that will allow us to further understand these phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer Learning using Denoising Auto-Encoders for Cellular-Level Annotation of Tumor in Pathology Slides

Adversarial examples can produce altered classifications using only seemingly innocuous, imperceptible perturbations to the original image. The imperceptibility of adversarial perturbations suggests that the corresponding classifiers use decision criteria different than those of a human. In a medical setting, inexplicable decision criteria confound a pathologist’s willingness to trust machine-generated annotations. Here, we analyze denoising tumor detection models to see if they are robust to imperceptible adversarial perturbations. Moreover, to be more fully trusted by pathologists, we require tumor detectors that generate interpretable annotations which segment pathology slides into tumorous and normal regions at the cellular level. We therefore compare transfer learning based on two different autoencoder architectures, one derived from a deep denoising bottleneck autoencoder and one from an over-complete sparse autoencoder. Both autoencoders were first trained in an unsupervised manner on a set of pathology slides drawn from the Camelyon16 dataset. The latent representations produced by each autoencoder were then passed to separate neural networks that were trained in a supervised manner on binary tumor-normal masks generated by pathologists at cellular resolution. Both tumor detectors supported better than 90% AUC PR as measured by the area under the precision/recall curve on a held-out pathology slide. To assess the underlying decision criteria used by both tumor detectors, we constructed imperceptible adversarial examples which reduced the AUC PR of both models to less than 70%. Random noise of the same amplitude had almost no effect on the AUC PR of either model. Additionally, each tumor detector was resistant to adversarial “transfer” attacks targeting the other. The adversarial perturbations showed strong characteristic differences: the deep denoising models perturbations were a very diffuse, seemingly unrecognizable pattern while the sparse coding models perturbations showed traces of tissue cells.

47 OTHER INSTRUMENTATION↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability Expansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. The Department of Energy/National Nuclear Security Administration (DOE/ NNSA) Stockpile Stewardship Management Plan (SSMP) identifies DARHT as a weapons mission critical facility along with the need to modernize DARHT to support weapons modernization efforts. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75 th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. The 2018 Nuclear Posture Review (NPR) states that the nuclear weapons infrastructure has suffered the effects of age and underfunding with no margin for further delay in recapitalizing the physical infrastructure. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Fabrication of Black Body Grids by Thick Film Printing for Quantitative Neutron Imaging

Neutron imaging offers deep penetration through many high-Z materials while also having high sensitivity to certain low-Z isotopes such as 1H, 6Li, and 10B. This unique combination of properties has made neutron imaging an attractive tool for a wide range of material science and engineering applications. However, measurements made by neutron imaging or tomography are generally qualitative in nature due to the inability of detectors to discriminate between neutrons which have been transmitted through the sample and neutrons which are scattered by the sample or within the detector. Recent works have demonstrated that deploying a grid of small black bodies (BBs) in front of the sample can allow for the scattered neutrons to be measured at the BB locations and subsequently subtracted from the total measured intensity to yield a quantitative transmission measurement. While this method can be very effective, factors such as the scale and composition of the sample, the beam divergence, and the resolution and construction of the detector may require optimization of the grid design to remove all measurement biases within a given experimental setup. Therefore, it is desirable to have a method by which BB grids may be rapidly and inexpensively produced such that they can easily be tailored to specific applications. In this work, we present a method for fabricating BB patterns by thick film printing of Gd2O3 and evaluate the performance with variation in feature size and number of print layers with cold and thermal neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thin aluminum filters for use on the Apollo Telescope Mount XUV spectrographs

Thin, unbacked, aluminum film filters were used on two extreme ultraviolet (XUV) instruments flown on the Apollo Telescope Mount of Skylab by the Naval Research Laboratory to transmit the XUV radiation while blocking the longer wavelength radiation that would saturate the detector. The requirements placed on these filters - large size, resistance to degradation by high acoustic and vibration fields, and low pinhole transmittances - were far more severe than those placed on any filters previously flown. Special techniques were developed for vacuum evaporation of the aluminum, removal of the films from the substrates, supporting the films and mounting them to obtain finished filters, and storing them so that no degradation took place. A description of these techniques will be given.

Schumacher, R. J.↗

Lensless Image Scanner

Image scanner uses moving and stationary parallel slits to produce pictures of visible, infrared, X-ray microwave, or acoustic sources. No lenses or mirrors required. Single detector views all parts of image simultaneously rather than raster making relatively-short exposure times possible. Potential applications of system include medical x-ray imaging.

Schindler, R. A.↗

Search for supermassive magnetic monopoles using mica crystals

The survival of the Galactic magnetic field almost certainly sets an astrophysical upper bound of approx. 10 to the minus 15th power cm(-2) sr(-1) s(-1) on the flux of monopoles. To improve significantly upon this Parker limit with direct, real time searches would require a detector area of approx. 10,000 square meters and a collection time of years. Several such searches are being contemplated. A novel alternative scheme using large mica crystals capable of recording and storing tracks of slow monopoles over a time scale of approx. 10 to the 9th power years was proposed.

Price, P. B.↗

The Sequential Filter Imaging Radiometer (SFIR), a new instrument configuration for Earth observations

The sequential filter imaging radiometer (SFIR) concept is presented, contrasted with other sensor configurations, and its strengths and weaknesses discussed. In a pushbroom SFIR the optics images the scene onto a long, narrow area array. The length of the array defines the field of view. The spectral defining filters are sequentially placed over the full array, a sample of data for that band taken, and then the next filter placed in front of the array. All of the filters are placed over the array in the time that it takes the image of the scene to advance the array width. Thus the entire scene is observed in each band. Advantages of the SFIR are: spectral bands can be broad, narrow or overlap; it is easy to improve signal to noise ratio; and it is simple to make bands polarized. Its main disadvantage is that it requires more detectors than other instrument configurations.

Maxwell, M. S.↗

The sequential filter imaging radiometer (SFIR)- A new instrument configuration for earth observations

The sequential filter imaging radiometer (SFIR) concept is presented, contrasted with other sensor configurations, and its strengths and weaknesses discussed. In a pushbroom SFIR the optics images the scene onto a long, narrow area array. The length of the array defines the field of view. The spectral defining filters are sequentially placed over the full array, a sample of data for that band taken, and then the next filter is placed in front of the array. All filters are placed over the array in the time that it takes the image of the scene to advance the array width. Thus, the entire scene is observed in each band. Advantages of the SFIR are: spectral bands can be broad, narrow or overlap; it is easy to improve signal to noise ratio; and it is simple to make bands polarized. Its main disadvantage is that it requires more detectors than other instrument configurations.

Maxwell, Marvin S.↗

Arrays of Bolometric Detectors for Submillimeter Astronomy

Large format two dimensional arrays of bolometric detectors are required for many millimeter and submillimeter applications. We describe the development and testing of such arrays and the plans for using them in both a ground-based and airborne instrument.

Silverberg, R. F.↗

Proton-Induced Transients and Charge Collection Mechanisms in a LWlR HgCdTe Focal Plane Array

Low noise performance of IR detectors is required, even in the presence of charged particles. Galactic cosmic rays, trapped protons & solar energetic particles. Particle induced transients identified as an important source of noise on ESA's ISO satellite. Also observed on NICMOS Instrument on NASA% Hubble Space Telescope. Tools to analyse particle induced transients have been developed. To date, comparisons of model have been made to flight data for a HgCdTe array exposed to trapped protons, and to a Si array exposed to laboratory protons. We report ground based proton transient measurements in a modem LWlR HgCdTe array operating under cryogenic conditions. Demonstration of charge collection mechanisms. Provide benchmarks for modeling tools.

Marshall, Paul↗

Development of a Submillimeter/Far-Infrared Radiometer for Cirrus Measurements

We introduce a low-cost, lightweight and compact polarisation-sensitive radiometer for the measurement of Cirrus clouds in the submillimeter and far-infrared region (10 150 cm-1). It is widely recognised that enhanced global measurements of cirrus properties are essential to the development of General Circulation and Climate Prediction Models since cirrus clouds have a strong effect on the Earth's Global Radiation Budget. The purpose of this project is to design and build a novel instrument suitable for aircraft deployment in order to measure Ice Water Path (IWP) along with cirrus particle size and shape. This airborne instrument, which is currently under development in Cardiff, will serve as a prototype for a future satellite-based radiometer. The radiometer will capitalize on the ongoing measurements of the NASA-led, Fourier Transform interferometer-based, FIRSC (Far-Infrared Sensor for Cirrus) instrument for which Cardiff has been closely associated. Data from FIRSC campaigns is being used to select optimum radiometer channels that exhibit good sensitivity to specific cirrus. This new multichannel radiometer will, however, have some key advantages over similar spectroscopic instruments, for example, portability, increased optical efficiency, a multi-angle field of view and a reduced integration period leading to an improved spatial resolution. The radiometer will benefit from the application of state-of-the-art submm/FIR polarizer and solid filter technology currently being developed in Cardiff. The instrument will require a detector array that is robust enough to withstand aircraft/space deployment.

Hayton, Darren↗

Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts

Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.

Tohda, Koji↗