Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Aquantis 2.5 MW Ocean Current Generation Device - Scaled Tank Test Design and Results

Aquantis 2.5 MW Ocean Current Generation Device, Tow Tank Dynamic Rig Structural Analysis Results. This is the detailed documentation for scaled device testing in a tow tank, including models, drawings, presentations, cost of energy analysis, and structural analysis. This dataset also includes specific information on drivetrain, roller bearing, blade fabrication, mooring, and rotor characteristics.

16 TIDAL AND WAVE POWER↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Design and Testing of a Device for Homogeneous Moon Dust Deposition on Test Articles/Systems

During this decade, NASA is charged to return humans to the surface of the Moon. One of the most challenging aspects to operating on the lunar surface is the regolith present, which is pervasive and damaging. To support systems design and validation for this environment, the handling and application of lunar simulants onto test articles or systems becomes important, albeit difficult. A device to apply the same amount of dust uniformly was developed in a previous study (Hollingsworth et al., 2006) but was only utilized with Mars dust simulant during that previous project. The current work provides evaluation of this device with multiple lunar simulants, each representing different composition as found at various locations on the Moon’s surface. Enhancements to the design and operation of the dust distributor are also described, along with a new digital imaging technique to calculate the percent surface coverage of the dust after deposition. The results support the use of the distributor and improved techniques to provide a uniform coating of dust on test articles and systems.

lunar↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Advanced Modeling of Micromirror Devices

The flexure-beam micromirror device (FBMD) is a phase only piston style spatial light modulator demonstrating properties which can be used for phase adaptive corrective optics. This paper presents a complete study of a square FBMD, from advanced model development through final device testing and model verification. The model relates the electrical and mechanical properties of the device by equating the electrostatic force of a parallel-plate capacitor with the counter-acting spring force of the device's support flexures. The capacitor solution is derived via the Schwartz-Christoffel transformation such that the final solution accounts for non-ideal electric fields. The complete model describes the behavior of any piston-style device, given its design geometry and material properties. It includes operational parameters such as drive frequency and temperature, as well as fringing effects, mirror surface deformations, and cross-talk from neighboring devices. The steps taken to develop this model can be applied to other micromirrors, such as the cantilever and torsion-beam designs, to produce an advanced model for any given device. The micromirror devices studied in this paper were commercially fabricated in a surface micromachining process. A microscope-based laser interferometer is used to test the device in which a beam reflected from the device modulates a fixed reference beam. The mirror displacement is determined from the relative phase which generates a continuous set of data for each selected position on the mirror surface. Plots of this data describe the localized deflection as a function of drive voltage.

Michalicek, M. Adrian↗

Engineering test procedure for the patient assist device

The test procedure completely tests the functioning of the patient assist device. All modes of operation are included in the test. Patient activated switches may be chosen for use with this device as desired. These switches, however, must be single-pole, single-throw, momentarily-on switches.

Schroder, M. A.↗

System Electrostatic Discharge Testing for Space Charging Caused ESD Events

This talk is about ground testing of spacecraft to determine immunity to the electrostatic discharges (ESDs) in certain Earth orbits. The particular spacecraft used as an example is the TOPEX/Poseidon spacecraft, an Earth orbiter with a 1334 km, 62 degree orbit. The talk is based on my recent experience with that spacecraft, but is an example of a generally good program. The program and this talk consist of the following elements: a discussion of the environment, showing the specific hazard areas on the spacecraft to illustrate the space charging and ESD process; spacecraft design features related to the environmental threat; the test device used for TOPEX/Poseidon; the test itself, including logistic and actions to avoid inadvertent damage to the spacecraft; and conclusions and lessons learned.

electrostatic↗

A Summary of Results from Vertical Drop Testing of Hybrid III and WIAMan ATDs

With the development and maturation of the Urban Air Mobility (UAM) market, many new types of electric vertical take-off and landing (eVTOL) vehicles will be flying in the national airspace carrying goods, people or conducting operations for a variety of missions. These types of vehicles are unlike current aircraft due to their novel design and operational profile. Several considerations must be examined in areas including noise, comfort and safety in order for these vehicles to be utilized and accepted into the current airspace system. Researchers at NASA Langley Research Center (LaRC) have conducted sub-scale and full-scale tests on representative eVTOL airframes and seats under a variety of dynamic impact conditions. These tests were conducted to generate data necessary to inform the development of standards in the areas specific to crashworthiness of eVTOL vehicle systems and safety. The data in this report relates to occupant responses obtained during a test campaign utilizing various makes, models, and sizes of Anthropomorphic Test Devices (ATD’s, a.k.a. crash test dummies) undergoing vertical impacts in a variety of seats. The data is intended to provide occupant behavior response and injury metrics for several anticipated impact scenarios that may occur in eVTOL operations. This report will present test data highlighting the effects of several variables on the test results. Discussions on the ATD sizes, along with comparisons between different ATD makes and types will be included. The performance of an in-house developed energy absorbing seat will be detailed, and discussions pertaining to the applicability in various loading conditions will be presented. Finally, a discussion as to the applicability of the tested results to eVTOL full-scale conditions will be included.

Dynamic Drop Testing↗

Autoignition Chamber for Remote Testing of Pyrotechnic Devices

The autoignition chamber (AIC) performs by remotely heating pyrotechnic devices that can fit the inner diameter of the tube furnace. Two methods, a cold start or a hot start, can be used with this device in autoignition testing of pyrotechnics. A cold start means extending a pyrotechnic device into the cold autoignition chamber and then heating the device until autoignition occurs. A hot start means heating the autoignition chamber to a specified temperature, and then extending the device into a hot autoignition chamber until autoignition occurs. Personnel are remote from the chamber during the extension into the hot chamber. The autoignition chamber, a commercially produced tubular furnace, has a 230-V, single-phase, 60-Hz electrical supply, with a total power output of 2,400 W. It has a 6-in. (15.2-cm) inner diameter, a 12-in. (30.4-cm) outer diameter and a 12-in.- long (30.4-cm), single-zone, solid tubular furnace (element) capable of heating to temperatures up to 2,012 F (1,100 C) in air.

Harrington, Maureen L.↗

SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

07 ISOTOPE AND RADIATION SOURCES↗

Behavior of compacted lunar simulants using new vacuum triaxial device

The objectives of this study are to create a lunar simulant locally from a basaltic rock and to design and develop a vacuum triaxial test device that can permit testing of compacted lunar simulant under cyclic loading with different levels of initial vacuum. Triaxial testing is performed in the device itself without removing the compacted specimen. Preliminary constrained compression and triaxial shear tests are performed to identify effects of initial confinements and vacuums. The results are used to define deformation and strength parameters. At this time, vacuum levels up to 0.0001 are possible. The research can aid in the development of compacted materials for various construction applications.

Desai, Chandra S.↗

A new structure for comparing surface passivation materials of GaAs solar cells

The surface recombination velocity (S sub rec) for bare GaAs is typically as high as 10 to the 6th power to 10 to the 7th power cm/sec, which dramatically lowers the efficiency of GaAs solar cells. Early attempts to circumvent this problem by making an ultra thin junction (xj less than .1 micron) proved unsuccessful when compared to lowering S sub rec by surface passivation. Present day GaAs solar cells use an GaAlAs window layer to passivate the top surface. The advantages of GaAlAs in surface passivation are its high bandgap energy and lattice matching to GaAs. Although GaAlAs is successful in reducing the surface recombination velocity, it has other inherent problems of chemical instability (Al readily oxidizes) and ohmic contact formation. The search for new, more stable window layer materials requires a means to compare their surface passivation ability. Therefore, a device structure is needed to easily test the performance of different passivating candidates. Such a test device is described.

Desalvo, Gregory C.↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗