Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffusion coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analytical homogenization techniques applied to the Fickian diffusion: Effective diffusivity coefficient

For multiple applications in nuclear energy, the ability to accurately represent material behavior with a simplified model is important to facilitate practical engineering-scale simulations. In this work, we focus on the homogenized thermal response of a medium containing spherical inclusions, similar to a fuel form (compact or pebble) containing TRISO particles. An extensive survey on effective thermal conductivity modeling was performed in our previous study, considering a random distribution of mono-sized spherical inclusions in a continuous matrix. Using the analogy between heat conduction and the simplified Fickian diffusion (or fission product species conservation), we can use the same analytical homogenization methods to obtain ETC as for the effective diffusivity coefficient (EDC). We performed several numerical experiments at varying conditions to assess the validity of our hypothesis for EDC calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Apparent Increasing Lithium Diffusion Coefficient with Applied Current in Graphite

In this study, we assert that the apparent lithium diffusion coefficient in graphite active particles in the negative electrodes of lithium-ion cells increases appreciably with the intercalation rate. This assertion is based on an electrochemical model analysis of a wide range of electrochemical micro-reference electrode full cell studies on a coated natural graphite and other literature results. Although the mechanism for this increase is a subject of further investigation, the results of our study suggest that the lithium transport in the graphite does not limit the maximum attainable charging rate in typical lithium-ion cells for electric vehicles.

25 ENERGY STORAGE↗

Simple analytical forms of the perpendicular diffusion coefficient for two-component turbulence. II. Dynamical turbulence with constant correlation time

We explore perpendicular diffusion based on the unified nonlinear transport theory. In Paper I, we focused on magnetostatic turbulence, whereas in the present article we include dynamical turbulence effects. For simplicity, we assume a constant correlation time. We show that there is now a nonvanishing contribution of the slab modes. We explore the parameter regimes in which the turbulence dynamics becomes important for perpendicular diffusion. Analytical forms for the perpendicular diffusion coefficient are derived, which can be implemented easily in solar modulation or shock acceleration codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The temperature-dependent diffusion coefficient of helium in zirconium carbide studied with first-principles calculations

The temperature-dependent diffusion coefficient of interstitial helium in zirconium carbide (ZrC) matrix is calculated based on the transition state theory. The microscopic parameters in the activation energy and prefactor are obtained from first-principles total energy and phonon frequency calculations including the all atoms. The obtained activation energy is 0.78 eV, consistent with experimental value. Besides, we evaluated the influence of C and Zr vacancies as the perturbation on helium diffusion, and found the C vacancy seems to confine the mobility of helium and the Zr vacancy promotes helium diffusion in some extent. These results provide a good reference to understand the behavior of helium in ZrC matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion coefficients of transition metals in fcc cobalt

Using first-principles density functional theory (DFT), we calculate the diffusivities of 32 different solute elements—all transition metals, together with Al and Si—in fcc cobalt within the formalism of the five-frequency model. For self-diffusion in fcc cobalt, we compare the accuracy of various approximations to the exchange-correlation energy functional of DFT in estimating the activation energy, and find that only the Perdew-Burke-Ernzerhof (PBE) approximation agrees well with experimental reports and all other functionals largely overestimate it. Our calculations also show that an accurate estimation of the self-diffusion coefficient requires explicit calculation of the effective jump frequency and vacancy formation entropy via phonons. Using accurate self-diffusion data and scaling all solute-related attempt frequencies with respect to the attempt frequency for self-diffusion using a simple relation involving the atomic mass and melting temperature of the solute yields solute diffusivities in excellent agreement with experiments, where such data is available. Additionally, we find that large solutes spontaneously relax toward the nearest neighbor vacancy to relieve the misfit strain, and the extent of this relaxation correlates negatively with the migration energy. Thus, in general, larger solutes have lower migration energies and diffuse faster than smaller solutes in fcc cobalt. However, extremely large solutes, e.g., group III elements Sc, Y, Lu, tend to be trapped in an energy valley located halfway toward the vacancy, and monovacancy mediated diffusion may no longer be valid in such cases. Finally, for all the solutes considered, we systematically tabulate the diffusion-related quantities calculated—diffusion prefactors, migration and activation energies—constructing an extensive and accurate first-principles database for solute diffusion in fcc cobalt.

36 MATERIALS SCIENCE↗

Statistical theory of diffusion in concentrated bcc and fcc alloys and concentration dependencies of diffusion coefficients in bcc alloys FeCu, FeMn, FeNi, and FeCr

The statistical theory of diffusion in concentrated bcc and fcc alloys with arbitrary pairwise interatomic interactions based on the master equation approach is developed. Vacancy–atom correlations are described using both the second-shell-jump and the nearest-neighbor-jump approximations which are shown to be usually sufficiently accurate. General expressions for Onsager coefficients in terms of microscopic interatomic interactions and some statistical averages are given. Both the analytical kinetic mean-field and the Monte Carlo methods for finding these averages are described. The theory developed is used to describe sharp concentration dependencies of diffusion coefficients in several iron-based alloy systems. For the bcc alloys FeCu, FeMn, and FeNi, we predict the notable increase of the iron self-diffusion coefficient with solute concentration c, up to several times, even though values of c possible for these alloys do not exceed some percent. For the bcc alloys FeCr at high temperatures T ≳ 1400 K, we show that the very strong and peculiar concentration dependencies of both tracer and chemical diffusion coefficients observed in these alloys can be naturally explained by the theory, without invoking exotic models discussed earlier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE PARALLEL DIFFUSION COEFFICIENT AND ADIABATIC FOCUSING OF COSMIC-RAY PARTICLES

In this paper, the problem of focused particle transport is revisited. A description in terms of a system of stochastic differential equations, completely equivalent to the Fokker-Planck equation, is suggested. The coefficient for spatial diffusion parallel to the mean magnetic field is calculated. The case of isotropic pitch angle scattering and weak focusing is analyzed in detail. The disagreement between a recent analysis by Shalchi and other treatments of the same problem is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduced Artifact Approach for Determining Diffusion Coefficients in Time-Resolved Microscopy

Ultrafast microscopy methods traditionally assume a Gaussian profile to extract excited state diffusivities from transport measurements. Although this fitting method recovers accurate diffusion coefficients when the point spread function is well-represented by a Gaussian, even minor spatial aberrations introduced by the imaging system cause significant errors in the determined value. To provide a more accurate measure of excited state transport in nano- and microscale materials systems, in this work an alternative analysis protocol is proposed that numerically convolves the Green’s function solution to the diffusion equation with the experimentally measured point spread function. In contrast to the Gaussian fitting approach, the numerical convolution is shown to be robust against artifacts caused by nonideal point spread functions. Furthermore, the numerical convolution approach is highly effective at resolving anisotropic diffusion in modeled data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Exciton Diffusion Coefficients in Two Dimensional Covalent Organic Frameworks with Different Domain Sizes Revealed by Ultrafast Exciton Dynamics

Large singlet exciton diffusion lengths are a hallmark of high performance in organic-based devices such as photovoltaics, chemical sensors, and photodetectors. In this study, exciton dynamics of a two-dimensional covalent organic framework, 2D COF-S, is investigated using ultrafast spectroscopic techniques. After photoexcitation, the COF-S exciton decays via three pathways: (1) excimer formation (4 +/- 2 ps), (2) excimer relaxation (160 +/- 40 ps), and (3) excimer decay (>3 ns). Excitation fluence-dependent transient absorption studies suggest that COF-5 has a relatively large diffusion coefficient (0.08 cm(2)/s). Furthermore, exciton-exciton annihilation processes are characterized as a function of COF-S crystallite domain size in four different samples, which reveal domain-size-dependent exciton diffusion kinetics. These results reveal that exciton diffusion in COF-S is constrained by its crystalline domain size. These insights indicate the outstanding promise of delocalized excitonic processes available in 2D COFs, which motivate their continued design and implementation into optoelectronic devices.

Flanders, Nathan C.↗

Measurement of diffusion coefficients from solution rates of bubbles

The rate of solution of a stationary bubble is limited by the diffusion of dissolved gas molecules away from the bubble surface. Diffusion coefficients computed from measured rates of solution give mean values higher than accepted literature values, with standard errors as high as 10% for a single observation. Better accuracy is achieved with sparingly soluble gases, small bubbles, and highly viscous liquids. Accuracy correlates with the Grashof number, indicating that free convection is the major source of error. Accuracy should, therefore, be greatly increased in a gravity-free environment. The fact that the bubble will need no support is an additional important advantage of Spacelab for this measurement.

Krieger, I. M.↗

A practical method of determining water current velocities and diffusion coefficients in coastal waters by remote sensing techniques

A simplified procedure is presented for determining water current velocities and diffusion coefficients. Dye drops which form dye patches in the receiving water are made from an aircraft. The changes in position and size of the patches are recorded from two flights over the area. The simplified data processing procedure requires only that the ground coordinates about the dye patches be determined at the time of each flight. With an automatic recording coordinatograph for measuring coordinates and a computer for processing the data, this technique provides a practical method of determining circulation patterns and mixing characteristics of large aquatic systems. This information is useful in assessing the environmental impact of waste water discharges and for industrial plant siting.

James, W. P.↗

Isotopic mass-dependence of metal cation diffusion coefficients in liquid water

Isotope distributions in natural systems can be highly sensitive to the mass (m) dependence of solute diffusion coefficients (D) in liquid water. Isotope geochemistry studies routinely have assumed that this mass dependence either is negligible (as predicted by hydrodynamic theories) or follows a kinetic-theory-like inverse square root relationship (D {proportional_to} m{sup -0.5}). However, our recent experimental results and molecular dynamics (MD) simulations showed that the mass dependence of D is intermediate between hydrodynamic and kinetic theory predictions (D {proportional_to} m{sup -{beta}} with 0 {<=} {beta} < 0.2 for Li{sup +}, Cl{sup -}, Mg{sup 2+}, and the noble gases). In this paper, we present new MD simulations and experimental results for Na{sup +}, K{sup +}, Cs{sup +}, and Ca{sup 2+} that confirm the generality of the inverse power-law relation D {proportional_to} m{sup -{beta}}. Our new findings allow us to develop a general description of the influence of solute valence and radius on the mass dependence of D for monatomic solutes in liquid water. This mass dependence decreases with solute radius and with the magnitude of solute valence. Molecular-scale analysis of our MD simulation results reveals that these trends derive from the exponent {beta} being smallest for those solutes whose motions are most strongly coupled to solvent hydrodynamic modes.

54 ENVIRONMENTAL SCIENCES↗

Mass Changes the Diffusion Coefficient of Particles with Ligand-Receptor Contacts in the Overdamped Limit

Inertia does not generally affect the long-time diffusion of passive overdamped particles in fluids. Yet a model starting from the Langevin equation predicts a surprising property of particles coated with ligands that bind reversibly to surface receptors: heavy particles diffuse more slowly than light ones of the same size. We show this by simulation and by deriving an analytic formula for the mass-dependent diffusion coefficient in the overdamped limit. We estimate the magnitude of this effect for a range of biophysical ligand-receptor systems, and find it is potentially observable for tailored micronscale DNA-coated colloids.

97 MATHEMATICS AND COMPUTING↗

An alternative model for estimating liquid diffusion coefficients requiring no viscosity data

An equation, based on the free volume of a liquid solvent, was derived via dimensional analysis, to predict binary diffusion coefficients. The equation assumed that interaction between the solute and liquid solvent molecules followed a Lennard-Jones potential. The equation was compared to other diffusivity equations and was found to give good results over the temperature range examined.

Morales, Wilfredo↗

Diffusion coefficient and nucleation density studies on electrochemical deposition of aluminum from chloroaluminate ionic liquid electrolytes

In this study, aluminum was electrodeposited from ionic liquids comprising a melt of alkyl imidazolium chlorides and aluminum chloride (AlCl 3 ). The ionic liquids utilized in this study were 1-ethyl-3-methyl-imidazolium chloride (EMIC)-AlCl 3 , 1-butyl-3-methylimidazolium chloride (BMIC)-AlCl 3 , and 1-hexyl-3-methyl-imidazolium chloride (HMIC)-AlCl 3 at the AlCl 3 mole fraction of 0.667 (molar ratio of 1:2). The electrochemical behavior of chloroaluminate species in the three ionic liquids was investigated by cyclic voltammetry (CV) and chronoamperometry (CA) techniques at different temperatures. The cyclic voltammograms indicated that the reduction of Al 2 Cl 7 – species to metallic aluminum followed a diffusion-controlled phenomenon. Moreover, even at a less negative applied potential, the higher current density was obtained for EMIC-AlCl 3 ionic liquid. That indicates that EMIC-AlCl 3 favors less energy consumption during the electrodeposition. The chronoamperometric analysis revealed that the onset of aluminum deposition from such ionic liquids proceeds via a three-dimensional instantaneous nucleation process. The concentrations of Al 2 Cl 7 – ions in the ionic liquids were calculated based on the thermodynamic data, which were 2520, 2271, and 2035 mol m –3 for EMIC-AlCl 3 , BMIC-AlCl 3 , and HMIC-AlCl 3 , respectively. The diffusion coefficient (D) values of Al 2 Cl 7 – species in such ionic liquids were also calculated at various temperatures. The D values determined from the CA technique at 363 K are 2.16 × 10 –11 , 1.03 × 10 –11 , and 0.87 × 10 –11 m 2 s –1 for EMIC-AlCl 3 , BMICAlCl 3 , and HMIC-AlCl 3 , respectively. In addition, the D value increased as temperature increased and decreased as the hydrocarbon group in the ionic liquid increased. As a result, the calculated grain sizes of nucleation range from 2 to 4 μm for these ionic liquids and are in good agreement with experimental data obtained from SEM micrographs.

42 ENGINEERING↗