Search NASASearch

SEARCH · Search NASA

Results for “digital light processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Light-detection electronics for a Raman lidar

A light-detection system for an optical radar, or lidar, unit to be used for remote temperature and composition measurements was designed, built, and bench tested. This detection system processes three return signal wavelengths: two Raman wavelengths, and the Rayleigh-Mie wavelength at 694.3 nanometers. Means of coping with photomultiplier tube instabilities and limitations are discussed. Circuits for gain control, ranging, and digitizing are included. The phototube gains can be switched fully on in 80 meters (450 nsec) or off in 30 meters (200 nsec) of range. The range circuit processes signals from 0.1 to 2 kilometers, with an estimated range resolution of less than 5 meters.

Leser, R. J.

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The X-29 flight-research program

The X-29 experimental aircraft, which is a technology integration and evaluation platform for such features as static longitudinal instability, sweptforward wings and three-surface longitudinal control, offers an opportunity to validate the entire aircrft design process through careful correlation and comparison of flight test results with wind tunnel results and design predictions. Attention is presently given to the design features of the aircraft, which encompass supercritical airfoils, digital flight control, and aeroelastically tailored composite wings, as well as to the flight test program that was formulated to investigate the interactions and relative merits of these design features, in light of data gathered by carefully positioned sensors.

Putnam, T. W.

Wetlands Survey

Ducks Unlimited, Inc. is dedicated to preservation of the world's waterfowl. Current inventories of wetland resources are crucial to effective waterfowl management. They contracted with NASA to use data from the LANDSAT satellites Thematic Mapper (TM), an advanced Earth scanning instrument that collects data in seven bands of the spectrum utilizing the Earth Resources Laboratory Applications Software (ELAS). The TM measures and records six values of light energy reflected from Earth and one value of heat energy as it scans the Earth below. On each orbital sweep, sensors produce a series of digital scenes representing features of Earth segments measuring about 100 by 110 miles, each scene covering about eight million acres, and each containing some 40 million bits of information called picture elements or pixels. They are computer processed and the resulting mosaic is projected on a digital display device.

Source record

Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures

Lightweight, electromagnetic interference (EMI) immune, fiber-optic, sensor- based structural health monitoring (SHM) will play an increasing role in aerospace structures ranging from aircraft wings to jet engine vanes. Fiber Bragg Grating (FBG) sensors for SHM include advanced signal processing, system and damage identification, and location and quantification algorithms. Potentially, the solution could be developed into an autonomous onboard system to inspect and perform non-destructive evaluation and SHM. A novel method has been developed to massively multiplex FBG sensors, supported by a parallel processing interrogator, which enables high sampling rates combined with highly distributed sensing (up to 96 sensors per system). The interrogation system comprises several subsystems. A broadband optical source subsystem (BOSS) and routing and interface module (RIM) send light from the interrogation system to a composite embedded FBG sensor matrix, which returns measurand-dependent wavelengths back to the interrogation system for measurement with subpicometer resolution. In particular, the returned wavelengths are channeled by the RIM to a photonic signal processing subsystem based on powerful optical chips, then passed through an optoelectronic interface to an analog post-detection electronics subsystem, digital post-detection electronics subsystem, and finally via a data interface to a computer. A range of composite structures has been fabricated with FBGs embedded. Stress tensile, bending, and dynamic strain tests were performed. The experimental work proved that the FBG sensors have a good level of accuracy in measuring the static response of the tested composite coupons (down to submicrostrain levels), the capability to detect and monitor dynamic loads, and the ability to detect defects in composites by a variety of methods including monitoring the decay time under different dynamic loading conditions. In addition to quasi-static and dynamic load monitoring, the system can capture acoustic emission events that can be a prelude to structural failure, as well as piezoactuator-induced ultrasonic Lamb-waves-based techniques as a basis for damage detection.

Moslehi, Behzad

The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD

Digital Particle Image Velocimetry (DPIV) Used for Space-Time Correlations in Nozzle Flow

An optical measurement technique known as Digital Particle Image Velocimetry (DPIV) was used previously to characterize the first- and second-order statistical properties of both cold and hot jet flows from externally mixed nozzles in NASA Glenn Research Center's Nozzle Acoustic Test Rig. In this technique, an electronic camera records particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Correlation processing of the recorded particle image pairs yields the two-component velocity field across the imaged plane of the flow. The information acquired using DPIV is being used to improve our understanding of the decay of turbulence in jet flows-a critical element for understanding the acoustic properties of the flow. Recently, two independent DPIV systems were installed in Glenn's Small Hot Jet Acoustic Rig, enabling multiplane correlations in time and space. The data were collected over a range of different Mach numbers and temperature ratios. DPIV system 1 was fixed to a large traverse rig, and DPIV system 2 was mounted on a small traverse system mounted on the large traverse frame. The light sheets from the two DPIV systems were aligned to lie in the same axial plane, with DPIV system 2 being independently traversed downstream along the flow direction. For each measurement condition, the DPIV systems were started at a fully overlapping orientation. A polarization separation technique was used to avoid cross-talk between the two systems. Then, the DPIV systems fields were shifted axially apart, in successively increasing steps. The downstream DPIV system 2 was triggered at a short time delay after the upstream DPIV system 1, where the time delay was proportional to the convective flow velocity in the shear layer of the jet flow and the axial separation of the two DPIV systems. The acquired data were processed to obtain the instantaneous velocity vector maps over a range of time delays and spatial separations. The velocity fields from the different DPIV systems were then cross-correlated to determine the degree of correlation remaining in the flow as the downstream convection distance was increased. The new data provide Lagrangian measurements of the convective turbulent structures in the shear layer of an exhaust nozzle. These measurements, obtained in both cold and hot flows, will be used to validate and correct models for space-time velocity correlations-long a missing key to predicting jet noise.

Wernet, Mark P.

The role of photographic parameters in laser speckle or particle image displacement velocimetry

The parameters involved in obtaining the multiple exposure photographs in the laser speckle velocimetry method (to record the light scattering by the seeding particles) were optimized. The effects of the type, concentration, and dimensions of the tracer, the exposure conditions (time between exposures, exposure time, and number of exposures), and the sensitivity and resolution of the film on the quality of the final results were investigated, photographing an experimental flow behind an impulsively started circular cylinder. The velocity data were acquired by digital processing of Young's fringes, produced by point-by-point scanning of a photographic negative. Using the optimal photographing conditions, the errors involved in the estimation of the fringe angle and spacing were of the order of 1 percent for the spacing and +/1 deg for the fringe orientation. The resulting accuracy in the velocity was of the order of 2-3 percent of the maximum velocity in the field.

Lourenco, L.

Target Recognition Using Neural Networks for Model Deformation Measurements

Optical measurements provide a non-invasive method for measuring deformation of wind tunnel models. Model deformation systems use targets mounted or painted on the surface of the model to identify known positions, and photogrammetric methods are used to calculate 3-D positions of the targets on the model from digital 2-D images. Under ideal conditions, the reflective targets are placed against a dark background and provide high-contrast images, aiding in target recognition. However, glints of light reflecting from the model surface, or reduced contrast caused by light source or model smoothness constraints, can compromise accurate target determination using current algorithmic methods. This paper describes a technique using a neural network and image processing technologies which increases the reliability of target recognition systems. Unlike algorithmic methods, the neural network can be trained to identify the characteristic patterns that distinguish targets from other objects of similar size and appearance and can adapt to changes in lighting and environmental conditions.

Ross, Richard W.

Droplet bioprinting of acellular and cell-laden structures at high-resolutions

Advances in digital light projection(DLP) based (bio) printers have made printing of intricate structures at high resolution possible using a wide range of photosensitive bioinks. A typical setup of a DLP bioprinter includes a vat or reservoir filled with liquid bioink, which presents challenges in terms of cost associated with bioink synthesis, high waste, and gravity-induced cell settling, contaminations, or variation in bioink viscosity during the printing process. Here, we report a vat-free, low-volume, waste-free droplet bioprinting method capable of rapidly printing 3D soft structures at high resolution using model bioinks and model cells. A multiphase many-body dissipative particle dynamics model was developed to simulate the dynamic process of droplet-based DLP printing and elucidate the roles of surface wettability and bioink viscosity. Process variables such as light intensity, photo-initiator concentration, and bioink formulations were optimized to print 3D soft structures (∼0.4–3 kPa) with a typical layer thickness of 50 µm, an XY resolution of 38 ± 1.5 μm and Z resolution of 237 ± 5.4 µm. To demonstrate its versatility, droplet bioprinting was used to print a range of acellular 3D structures such as a lattice cube, a Mayan pyramid, a heart-shaped structure, and a microfluidic chip with endothelialized channels. Droplet bioprinting, performed using model C3H/10T1/2 cells, exhibited high viability (90%) and cell spreading. Additionally, microfluidic devices with internal channel networks lined with endothelial cells showed robust monolayer formation while osteoblast-laden constructs showed mineral deposition upon osteogenic induction. Overall, droplet bioprinting could be a low-cost, no-waste, easy-to-use, method to make customized bioprinted constructs for a range of biomedical applications.

DLP

A search strategy for SETI - The search for extraterrestrial intelligence

A search strategy is proposed for the detection of signals of extraterrestrial intelligent origin. It constitutes an exploration of a well defined volume of search space in the microwave region of the spectrum and envisages the use of a combination of sky survey and targeted star approaches. It is predicated on the use of existing antennas equipped with sophisticated multichannel spectrum analyzers and signal processing systems operating in the digital mode. The entire sky would be surveyed between 1 and 10 GHz with resolution bin widths down to 32 Hz. More than 700 nearby solar type stars and other selected interesting directions would be searched between 1 GHz and 3 GHz with bin widths down to 1 Hz. Particular emphasis would be placed on those solar type stars that are within 20 light years of earth.

Billingham, J.

Optical computing with laser light

Linear and nonlinear optical processing techniques (Fourier transformation, convolution and correlation, arithmetic operations - addition and subtraction with gratings, generalized orthogonal transformations; theta modulation, half-tone screen process, optical feedback) for mathematical computations are reviewed. The use of gratings and computer holograms in addition, subtraction, differentiation, and application of generalized transformations is discussed. Use of nonlinear optical elements with or without optical coherent feedback in such nonlinear operations as taking logarithms and thresholding is described. Applications in hybrid systems incorporating digital computer and optical processor with real-time interface devices, or optical threshold and logic devices for parallel processing to apply digital techniques to optical information are considered.

Lee, S. H.

Polarization compensator for optical communications

An optical data communication system is provided whereby two orthogonal polarization states of a light beam carrier correspond to digital states. In such a system, automatic polarization compensation is provided by applying a dither modulating voltage to a cell exhibiting the electro-optic effect. The cell controls the relative phase of electric field components of an input light beam enabling the dither frequency component of the difference of the instantaneous powers in the two polarization states to be coherently detected. A signal derived from the coherent detection process is fed back to the cell via an integrator to form polarization bias compensating servo loop ot Type 1.

Fitzmaurice, M. W.

Laser Calibration of an Impact Disdrometer

A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.

calibration

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.

High angle of attack position sensing for the Southampton University magnetic suspension and balance system

An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

Parker, David H.

A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

Lloyd, J. F., Sr.