Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Star counts and galactic structure

Star counts are discussed as an aid in studies of galactic structure. Iterative computations using a method-of-color-bins to match numerical models with observational data are described. The star counts provide bounds for the luminosity function and the color-magnitude diagram and allow spheroid normalization in a copycat Galaxy model which posits a galaxy with a Population I disk and a Population II spheroid. Good agreement has been obtained between star counts predicted by the model and observed distributions, including color and magnitude ranges and direction. Modifications being considered for the model include consideration of the halo, a galactic bulge and a thick disk. Several galactic structural features which have yet to be modeled and which may be tractable to the copycat model corrected with star counts are identified.

Bahcall, John N.↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital first order hold circuit

There is provided a digitally controlled first order hold circuit and waveform synthesizer for digitally controlling the representation of a function over an approximation interval. In accordance with the operation of the invention, the first order hold circuit and waveform generator receives a digital data input signal which contains initial condition data, up/down data, and slope data for the approximation interval. The initial condition data is loaded into an up/down counter which is incremented using counting data at a rate depending on the value of the slope data and in a direction depending on the value of the up-down data. In order to minimize delays arising from data acquistion, two frequency synthesizer circuits are provided such that one frequency synthesizer provides counting data while the other frequency synthesizer receives slope data. During alternating intervals, the other frequency synthesizer circuit provides counting data while the other circuit receives slope data. In addition, long length data input signals covering a plurality of approximation intervals are provided to reduce the demands on a main system central processing unit.

Chan, Fred N.↗

Property Measurement

Van is used by Land Inventory Systems to measure and map property for tax assessment purposes. It is adapted from navigation system of the Lunar Rover wheeled vehicle in which moon-exploring astronauts traveled as much as 20 miles from their Lunar Module base. Astronauts had to know their precise position so that in case of emergency they could take the shortest route back. Computerized navigational system kept a highly accurate record of the directional path providing continuous position report. Distance measuring subsystem was a more accurate counterpart of automobile odometer system counts revolutions of wheels and encoders generate electrical pulses for each fractional revolution and the computer analyzed the pulses to determine the distance traveled in a given direction.

Source record↗

A component of nongyrotropic (phase-bunched) electrons upstream from the earth's bow shock

The count rates of 1.5- and 6-keV electrons measured on ISEE 1 and ISEE 2 are at times strongly spin modulated despite the fact that the axes of the detectors lie along the spin axis of the spacecraft. Spatial gradients in the guiding center density are ruled out as a cause of the spin modulation. The characteristics of the spin modulation can be explained if the electron velocity distribution is nongyrotropic. The procedure is to show that the direction of the plasma flow velocity during times of spin modulation does not lie along the direction of the local magnetic field when both are projected onto the ecliptic plane. While a gyrotropic distribution will cause spin modulation, the count rate maximum will correspond to the direction of the local magnetic field. Gyrophase-bunched electrons are seen within a few tens of kilometers of the shock and as far upstream as 30,000 km from the shock, suggesting that a wave is associated with their propagation. The magnetosheath electrons in the same energy range are also nongyrotropic at times.

Anderson, K. A.↗

Time-Resolved Line Shapes of Single Quantum Emitters via Machine Learned Photon Correlations

Solid-state single-photon emitters (SPEs) are quantum light sources that combine atomlike optical properties with solid-state integration and fabrication capabilities. SPEs are hindered by spectral diffusion, where the emitter’s surrounding environment induces random energy fluctuations. Timescales of spectral diffusion span nanoseconds to minutes and require probing single emitters to remove ensemble averaging. Photon correlation Fourier spectroscopy (PCFS) can be used to measure time-resolved single emitter line shapes, but is hindered by poor signal-to-noise ratio in the measured correlation functions at early times due to low photon counts. Here, we develop a framework to simulate PCFS correlation functions directly from diffusing spectra that match well with experimental data for single colloidal quantum dots. We use these simulated datasets to train a deep ensemble autoencoder machine learning model that outputs accurate, noiseless, and probabilistic reconstructions of the noisy correlations. Using this model, we obtain reconstructed time-resolved single dot emission line shapes at timescales as low as 10 ns, which are otherwise completely obscured by noise. This enables PCFS to extract optical coherence times on the same timescales as Hong-Ou-Mandel two-photon interference, but with the advantage of providing spectral information in addition to estimates of photon indistinguishability. Further, our machine learning approach is broadly applicable to different photon correlation spectroscopy techniques and SPE systems, offering an enhanced tool for probing single emitter line shapes on previously inaccessible timescales.

74 ATOMIC AND MOLECULAR PHYSICS↗

Remote sensing of phytoplankton density and diversity in Narragansett Bay using an airborne fluorosensor

An aircraft-borne remote system is presented that utilizes narrow-band light from multiple dye lasers to excite selected algae photopigments and then measures the resultant flourescence emitted from chlorophyll a at 685 nm. Tests were conducted with both pure and mixed cultures of marine algae from a series of field tests taken from piers and bridges of Narragansett Bay, and a prototype remote fluorosensor was flown over the Bay during the 1978 winter-spring diatom bloom. Remote fluorescence obtained at hover points over sea-truth stations showed correlations with in situ fluorescence, total chlorophyll a, and cell count. It was concluded that the ratio of remote fluorescence to direct chlorophyll a concentration was less variable than expected, and the distribution of total chlorophyll a between two major photoplankton color groups showed three distinct areas, within the Bay, of green and golden-brown species.

Farmer, F. H.↗

Regulation of hematopoiesis in the suspended rat as a model for space flight

A series of studies was completed in which a variety of routine hematological and other parameters were obtained from sequential sampling of control and suspended rats. These data showed that, during suspension, the rats failed to gain weight at the same rate as the controls, ate and drank significantly less, demonstrated a transient increase in peripheral hematocrit and RBC count, a transient decrease in MCH, suppressed reticulocyte counts and a progressive decrease in MCV but no change in RBC shape. Leukocyte counts were variably decreased but no significant changes in platelet numbers were noted. Post-suspension, evidence of anemia was present from a reduced RBC count, hemoglobin, hematocrit, and MCV. A leukocytosis was also noted. Efforts directed to the collection of data aimed at understanding changes in blood volume during suspension are also discussed. As part of these studies the following parameters were investigated; RBC survival, in vitro leukocyte reactivity to PHA, bone marrow and spleen cellularity and morphology, ferrokinetics, and the hematopoietic inductive microenvironment.

Dunn, C. D. R.↗

ASCA Observations of the T Tauri Star SU Aurigae and the Surrounding L1517 Dark Cloud

We present the results of a approximately equals 40 ks pointed Advanced Satellite for Cosmology and Astrophysics (ASCA) observation of the L1517 star-forming region, centered on the X-ray-bright T Tauri star SU Aurigae. This star has the highest X-ray luminosity of any classical T Tauri star in the Taurus-Auriga region, and its optical spectra show evidence for both mass inflow and outflow. Strong X-ray emission was detected from SU Aur (L(sub x) = 10(exp 30.9) ergs s(exp -1)) as well as weaker emission from five other pre-main-sequence stars. Although no large-amplitude flares were detected, the X-ray emission of SU Aur showed clear variability in the form of a slow decline in count rate during the 1.3 day observation. We provide the first direct comparison of the coronal differential emission measure (DEM) distribution of a classical T Tauri star with that of a young main-sequence star of similar spectral type. The DEM distributions of SU Aur (G2; age 3 Myr) and the young solar-like star EK Draconis (GO V; age 70 Myr) are qualitatively similar, with both showing a bimodal temperature distribution characterized by a cool plasma component peaking at approximately 8-9 MK and a hot component peaking at approximately 20-21 MK. However, there is a striking difference in the relative proportion of plasma at high temperatures in the two stars, with hot plasma (>20 MK) accounting for approximately equals 80% of the volume emission measure of SU Aur, compared to only approximately equals 40% in EK Dra. These results provide new insight into the changes that will occur in the corona of a T Tauri star as it descends onto the main sequence. A sharp decline in the fraction of coronal plasma at flarelike temperatures will occur during the late-T Tauri and post-T Tauri phases, and other recent X-ray studies have shown that this decline will continue after the young solar-like star reaches the main sequence.

Skinner, Stephen L.↗

Molecular Rayleigh Scattering Diagnostic for Measurement of High Frequency Temperature Fluctuations

A novel technique for measurement of high frequency temperature fluctuations in unseeded gas flows using molecular Rayleigh scattering is investigated. The spectrum of laser light scattered from molecules in a gas flow is resolved using a Fabry-Perot interferometer. The width of the spectral peak is broadened by thermal motion of the molecules and hence is related to gas temperature. The interference fringe pattern containing spectral information is divided into four concentric regions using a series of mirrors angled with respect to one another. Light from each of these regions is directed towards photomultiplier tubes and sampled at 10 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows measurement of gas temperature. Independently monitoring the total scattered intensity provides a measure of gas density. This technique also has the potential to simultaneously measure a single component of flow velocity by monitoring the spectral peak location. Measurements of gas temperature and density are demonstrated using a low speed heated air jet surrounded by an unheated air co-flow. Mean values of temperature and density are shown for radial scans across the jet flow at a fixed axial distance from the jet exit plane. Power spectra of temperature and density fluctuations at several locations in the jet are also shown. The instantaneous measurements have fairly high uncertainty; however, long data records provide highly accurate statistically quantities, which include power spectra. Mean temperatures are compared with thermocouple measurements as well as the temperatures derived from independent density measurements. The accuracy for mean temperature measurements was +/- 7 K.

Mielke, Amy F.↗

Directionality of continuum gamma rays from solar flares

Using hard X-ray burst spectrometer total counts as calibration, the changes in the brightness of gamma rays above 300 keV as a function of the heliocentric angle of a flare are investigated. The normalized gamma-ray brightness, on the average, increases with the heliocentric angle; a flare at the limb is estimated to be 13 times brighter in beam gamma rays than a similar flare near the central meridian. Both pancakelike electron distributions and downward beam distributions can be adjusted to produce the deduced limb brightening.

Bai, Taeil↗

Baseline acoustic levels of the NASA Active Noise Control Fan rig

Extensive measurements of the spinning acoustic mode structure in the NASA 48 inch Active Noise Control Fan (ANCF) test rig have been taken. A continuously rotating microphone rake system with a least-squares data reduction technique was employed to measure these modes in the inlet and exhaust. Farfield directivity patterns in an anechoic environment were also measured at matched corrected rotor speeds. Several vane counts and spacings were tested over a range of rotor speeds. The Eversman finite element radiation code was run with the measured in-duct modes as input and the computed farfield results were compared to the experimentally measured directivity pattern. The experimental data show that inlet spinning mode measurements can be made very accurately. Exhaust mode measurements may have wake interference, but the least-squares reduction does a good job of rejecting the non-acoustic pressure. The Eversman radiation code accurately extrapolates the farfield levels and directivity pattern when all in-duct modes are included.

Sutliff, Daniel L.↗

Stress and adaptation responses to repeated acute acceleration.

Study in which groups of adult male chickens (single-comb white leghorn) were exposed daily to acceleration (centrifugation) of 2 or 3 G for 10 min, 1, 4, 8, 12, 16, and 24 hr (continuously), or 0 time (controls). After approximately five months of this intermittent treatment (training), the birds were exposed to continuous accelerations of the same G force (intensity). The degree of stress and adaptation of each bird was determined by survival and relative lymphocyte count criteria. Intermittent training exposures of 2 G developed levels of adaptation in birds directly proportional to the duration of their daily exposure. Intermittent training periods at 3 G, however, produced a physiological deterioration in birds receiving daily exposures of 8 hr or more. Adaptive benefits were found only in the 1- and 4-hr-daily intermittent 3-G exposure groups. Exposure to 3 G produced an immediate stress response as indicated by a low relative lymphocyte count which returned to control (preexposed) values prior to the next daily acceleration period in the 10-min, 1-hr, and 4-hr groups. This daily recovery period from stress appeared to be necessary for adaptation as opposed to deterioration for the more severe environmental (3 G) alteration.

Burton, R. R.↗

Counting digital filter

Overall design of filter combines radix converter with ADC in single functional unit that directly converts analog input to its negative binary representation. Four basic elements of filter are fixed register, shift register, counter, and accumulator.

Zohar, S.↗

Automated Bacterial Identification and Morphological Feature Analysis in Low‐Dose Cryo‐EM Using YOLOv11

Bacteria rapidly adapt to environmental cues through morphological and ultrastructural changes that correlate with physiology and behavior. Cryogenic transmission electron microscopy (cryo‐TEM) can capture these phenotypic changes in near‐native, vitrified states, but manual analysis of low‐dose micrographs is labor intensive and limits throughput. Here, we present an end‐to‐end workflow that combines low‐dose cryo‐TEM imaging with a YOLOv11‐based instance‐segmentation model to automatically identify bacteria and quantify key structural features directly from the micrographs. This workflow enables (i) robust bacterial localization and counting from low‐magnification atlas/montage images, (ii) automated measurements of cell‐envelope (outer–inner membrane) thickness and anisotropy from higher‐magnification views, and (iii) detection and quantification of bacteria–flagella interactions, including overlap length and curvature metrics for interacting versus noninteracting flagella. Using Pantoea sp. YR343 grown under distinct media conditions, we show that the automated measurements agree with manual annotations while substantially reducing analysis time. Together, these tools provide a practical framework for scalable bacterial identification and quantitative phenotyping in low‐dose cryo‐TEM datasets and establish a foundation for extending cryo‐TEM image analysis toward higher‐throughput studies of microbial heterogeneity and biointerfaces.

YOLOv11↗

Recording-tape position sensor

Device uses tachometer pulses from capstan and reset pulse from one reel to sense count of tach pulses per revolution of reel. Number of pulses is direct measurement of tape stack radius and is independent of tape speed or direction.

Schoppet, G. C.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Qualification of A Transition Edge Sensor Based Anti-Coincidence Detector for A Probe Class Mission

The Line Emission Mapper (or LEM) is an X-ray probe class mission aimed to study the physics of galaxy formation, with a large field-of-view, high-resolution transition-edge sensor (TES) microcalorimeter. Because of the diffuse and faint nature of LEM’s targets, a high-fidelity anticoincidence detector (anti-co) is essential to reduce instrument background below the level of sky background. Lying directly behind the LEM sensor, the anti-co will detect ~3 counts per second per square centimeter from background galactic cosmic rays and the secondary particles they induce to detect and flag any events that could be confused with a science photon in the 0.3-2 keV signal band of LEM. Our design spans an active region 4-cm in diameter. It consists of 12 quasiparticle-trap-assisted electrothermal-feedback (QET) channels, each with 100 parallel TESes with common bias lines. The TES is a narrow strip of Mo/Au bilayer. We present fabrication processes that maintain the transition temperature (T c ) in Mo/Au bilayer structures across the active region. We further present a new design based on a a-Si/W TES layer that has previously achieved reasonable uniformity in lab testing.

x-ray↗