Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unconventional desalination: The use of cyclone separators in HDH desalination to achieve zero liquid discharge

Research in water desalination technologies is constantly growing to meet global demands for freshwater. Though acting to meet these demands, the rapid growth and spread of desalination technologies poses environmental issues due to the increasing brine concentrates that are ultimately discharged back to nature. This article presents a cyclone separator to transform a humidification-dehumidification (HDH) cycle to a dual-product cycle to produce freshwater and solid salt crystals for highly saline streams. A desalination cycle equipped with a cyclone separator is used to treat water with 3.5%–81% salinity. The separation efficiency is well above 99% and can produce potable water from hyper saline feed in a once-through process. Further, the cyclone separator performance was tested under different conditions including humidity ratios, relative humidities, and feed stream's salinities. The cyclone separator is self-cleaning and overcomes salt scaling. This behavior is a direct function of the walls' temperature and the carrier air dew point. Self-cleaning capability allows the cyclone separator to treat feed water of extreme salinities (up to 810,000ppm) down to freshwater salinity with zero liquid discharge. The cyclone separator was utilized in a novel HDH desalination technology to treat different salinities. The product was freshwater of salinity <500ppm.

42 ENGINEERING↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Review on Preprocessing Strategies, Deactivation, Thermal Safety, and Future Perspectives in Lithium-Ion Battery Recycling

The rapid growth in the use of lithium-ion batteries (LIBs) in electric vehicles, consumer electronics, and renewable energy storage has made effective end-of-life management essential. Recycling LIBs is critical not only for resource recovery and environmental protection but also for ensuring safety and economic viability. This review focuses on the preprocessing technologies that precede typical recovery processes, including disassembly, sorting, discharging, electrolyte removal, dismantling, thermal treatment, separation, and flotation. These steps play a foundational role in determining the efficiency, safety, and environmental impact of LIB recycling. LIBs pose substantial fire and explosion risks due to residual charge, flammable electrolytes, and reactive materials. The conditions and successive progression of the exothermic reactions which lead to thermal runaway has been discussed. It also explores secure deactivation techniques such as external circuit discharge, saline immersion, and thermomechanical methods, alongside fire prevention strategies including the use of flame retardants, elimination of oxidants, and reduction of heat generation and accumulation. Challenges and future directions are outlined, highlighting the need for standardized designs, automation, and safer, more sustainable recycling infrastructure. Furthermore, this review is distinguished by its focused analysis of preprocessing and deactivation steps, with particular attention to the thermal safety engineering aspects of LIB recycling.

Battery deactivation↗

Stormwater Storage and Retention Within an Urban Prairie Wetland Complex

Climate change is expected to increase the frequency and severity of flooding in the Great Lakes region. In many cities, flood-control infrastructure is insufficient to protect against future climate conditions. Consequently, there is increasing focus on stormwater storage provided by urban greenspace, such as wetlands and prairies, but the ecohydrological behavior of these ecosystems is not well understood when they are embedded within cities. To improve understanding of hydrological connectivity between urban areas and natural greenspaces, we deployed a sensor network in Gensburg Markham Prairie (GMP), a large intact prairie-wetland complex in south suburban Chicago. We used the resulting high-frequency time-series data to assess surface-subsurface hydrologic dynamics between upland and low-lying wetland areas, interactions between the prairie and surrounding environment, and stormwater storage provided by the prairie. Rapid infiltration within the prairie during and after storm events provides subsurface flow that stores considerable water, flattens storm hydrographs, and increases the wetland hydroperiod. Much of the stormwater input to GMP derives from the surrounding cityscape. Consequently, storage within the prairie-wetland system reduces and slows stormwater discharge to downstream urban communities. For a typical 5-year 24-hr storm with 10.9 cm of rain, GMP stores 77,100 m 3 , 64% greater than the estimated direct rainfall volume onto the prairie, yielding 30,000 m 3 of offsite stormwater storage. This improved understanding of ecohydrological dynamics in urban prairies and wetlands informs the design and implementation of green infrastructure to meet growing needs for stormwater management.

Rivera, Vivien Anne [Northwestern University, Evan↗

Abrasion wear at high temperature in particle receiver type Concentrating Solar Power Systems

The use of solid particles as a heat transfer fluid in receivers for concentrating solar powerplants has garnered much attention in the past decade. Particles are not only stable at temperatures above 700 °C but are also able to absorb solar energy directly, which gives them a distinct advantage over conventional molten salts. The use of particles can, however, cause material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. Stainless steel alloy 316, nickel-based alloy Inconel® 740H®, Haynes 230, and a 60% alumina, low-cement refractory castable from Allied Mineral Products were tested for wear from first-of-a-kind high-temperature low-velocity abrasion-erosion experiments. The tests are designed to simulate potential conditions in Generation 3 falling particle Concentrating Solar Power (CSP) systems. Simultaneous experiments were conducted at room temperature as well to draw comparison on the role of temperature on abrasion wear rates. It was noted that the abrasion wear rate in candidate materials was driven by the oxidation resistance of the material. The findings from these experiments will be used to determine life-time of critical components in particle receiver concentrated solar powerplants.

14 SOLAR ENERGY↗

Chemical characterization of microplastic particles formed in airborne waste discharged from sewer pipe repairs

Microplastic particles are of increasing environmental concern due to the widespread uncontrolled degradation of various commercial products made of plastic and their associated waste disposal. Recently, common technology used to repair sewer pipes was reported as one of the emission sources of airborne microplastics in urban areas. This research presents results of the multi-modal comprehensive chemical characterization of the microplastic particles related to waste discharged in the pipe repair process and compares particle composition with the components of uncured resin and cured plastic composite used in the process. Analysis of these materials employs complementary use of surface-enhanced Raman spectroscopy, scanning transmission X-ray spectro-microscopy, single particle mass spectrometry, and direct analysis in real-time high-resolution mass spectrometry. Further, it is shown that the composition of the relatively large (100 μm) microplastic particles resembles components of plastic material used in the process. In contrast, the composition of the smaller (micrometer and sub-micrometer) particles is significantly different, suggesting their formation from unintended polymerization of water-soluble components occurring in drying droplets of the air-discharged waste. In addition, resin material type influences the composition of released microplastic particles. Results are further discussed to guide the detection and advanced characterization of airborne microplastics in future field and laboratory studies pertaining to sewer pipe repair technology.

54 ENVIRONMENTAL SCIENCES↗

Rapid charging made practical in graphite-based lithium batteries: surface-acoustic wave turbulent electrolyte mixing to overcome diffusion limited charging rates [Final Report]

One of the key limits in rapidly recharging a lithium-ion battery is the depletion of lithium ions within the electrolyte adjacent the anode during charging and long diffusion time to overcome this depletion. It also causes dendrite formation, inefficient use of the lithium, and battery degradation over many charge-discharge cycles. Because the liquid electrolyte remains quiescent and unmixed, this depletion layer’s depth rapidly grows to match the anode-cathode separation distance at even modest charge rates. The solution proposed by PI Prof. James Friend and Co-PI Prof. Ping Liu, both from the University of California, San Diego, is to mix the electrolyte and minimize the Li+ ion concentration gradient during charging. Even in the presence of the separator, the charging rate could then be significantly increased. They propose to accomplish this using surface acoustic wave (SAW)-driven acoustic streaming, a technique employing 10-mW fingernail-sized solid-state devices from the telecommunications industry to drive turbulent mixing to submicron length scales in a manner completely compatible with the typical 20700 and 18650 cells used in electric vehicles. 0.1. Turbulent acoustic streaming mixes the electrolyte during charging—even with separator Our proposed 100-MHz SAW device used to recirculate the electrolyte is compatible with lithium- ion battery electrochemistry, as it is made in our lab of single-crystal lithium niobate. Their solution is straightforward to drive from a DC power source alongside the signal provided during battery charging. The device is only needed during charging and does not consume power dur- ing battery discharge. Uniquely, SAW generates extreme accelerations of over 1 billion meters per second squared in the fluid, driving turbulent mixing from centimeter to submicron length scales, even through the porous separator materials that tend to be used in batteries, all while avoiding interfering with the anode’s solid electrolyte interphase layer that forms during use. By employing novel fluid mechanics, the investigators are proposing a new direction for battery research away from direct use of materials science and electrochemistry. The chemistry agnostic solution may be employed in any battery chemistry that makes use of liquid electrolytes, providing a broader transformative benefit to the battery research community. They are to produce a series of prismatic and 20700-cell sized 2 Ah batteries capable of being charged and discharged at least 500 times without more than 20% loss in battery capacity, and to provide analysis tools useful to the battery research and development community for adopting this approach for other battery chemistries and configurations.

25 ENERGY STORAGE↗

Cost‐Effective and Scalable Approach for the Separation and Direct Cathode Recovery from End‐of‐Life Li‐Ion Batteries

Li-ion battery recycling presents a promising opportunity to decrease dependence on foreign sources of materials and harvest precious materials within the United States. Herein, a superior complete direct recycling process on individual end-of-life cells is reported where the recovered high-purity cathode active material, as well as electrolyte salt Li hexafluorophosphate (LiPF 6 ) can be reused without significant processing. This new process utilizes a series of mechanical separation steps that enable the separation of the cathode and anode active materials while they are still attached to their current collectors. Using this type of process can significantly reduce metal contamination and enable a clean cathode that can be directly recycled. The process if implemented commercially can greatly reduce the environmental burden of batteries as the greenhouse gas emissions of 8.25 kg CO 2 e kg −1 from the direct recycling process are 64% lower compared to those from virgin production of cathode material. During electrochemical testing of the recovered LiNi 0.6 Mn 0.2 Co 0.2 O 2 a discharge capacity of ≈160 mAh g −1 and good cyclability of over 250 cycles at 0.33C are achieved. This success paves a new pathway to explore and optimize existing Li-ion battery recycling procedures.

electrolyte reuse↗

Time-dependent experimental identification of inter-ELM microtearing modes in the tokamak edge on DIII-D

In a series of discharges on the DIII-D tokamak, fast vertical plasma jogs are used to induce current perturbations in the steep gradient region of the H-mode edge. These current perturbations directly influence the edge q profile, decoupling the resonant location and instability drive of pedestal-localized microtearing modes (MTMs.) By exploiting this effect, we develop and apply a new experimental technique to track the dynamical frequency evolution of MTMs in the pedestal region, providing a compelling validation of the MTM model. The frequency of potential MTMs is calculated as the Doppler-shifted electron diamagnetic frequency at rational q=m/n surfaces, showing remarkable agreement with chirped frequency behavior of n=3, 4 and 5 modes detected with fast magnetics. Data is collected throughout multiple ELM cycles in order to build robust statistics describing the time-dependent frequency evolution of MTMs, which can be explained by examining the recovery of pedestal gradients after an ELM event. MTMs have a dominant transport contribution in the electron thermal channel, so the presented results indicate that reduced models of pedestal transport must be electromagnetic in nature and constructed with accurate calculations of MTM stability; inclusion of this physics is essential for accurate predictions of the electron temperature pedestal profile. Supporting measurements of mode saturation, propagation direction and transport fingerprints are made to support the dynamic frequency determination, unambiguously and experimentally identifying MTMs in the pedestal region of DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

WEC-SIM Support for an Innovative Zero Discharge Supercritical Water Based Wave Energy Desalination System (CRADA Final Report)

NREL will assist East Carolina University in its development of the foundational knowledge and proof of concept that are needed for future process scale up and commercialization of a sustainable wave-to-water (direct pressurization) desalination unit powered by a wave energy converter. NREL will provide guidance and support to East Carolina University on its: use of the NREL developed WEC-Sim based wave to water system, exploring the WEC-Sim/ASPEN Plus data exchange communication, and using experimental data to hopefully provide validation of analytical models.

16 TIDAL AND WAVE POWER↗

Secondary electron emission measurements from imidazolium-based ionic liquids

The electron-induced secondary electron emission (SEE) yields of imidazolium-based ionic liquids are presented for primary electron beam energies between 30 and 1000 eV. These results are important for understanding plasma synthesis of nanoparticles in plasma discharges with an ionic liquid electrode. Due to their low vapor pressure and high conductivity, ionic liquids can produce metal nanoparticles in low-pressure plasmas through reduction of dissolved metal salts. In this work, the low vapor pressure of ionic liquids is exploited to directly measure SEE yields by bombarding the liquid with electrons and measuring the resulting currents. The ionic liquids studied are [BMIM][Ac], [EMIM][Ac], and [BMIM][BF 4 ]. The SEE yields vary significantly over the energy range, with maximum yields of around 2 at 200 eV for [BMIM][Ac] and [EMIM][Ac], and 1.8 at 250 eV for [BMIM][BF 4 ]. Molecular orbital calculations indicate that the acetate anion is the likely electron donor for [BMIM][Ac] and [EMIM][Ac], while in [BMIM][BF 4 ], the electrons likely originate from the [BMIM] + cation. The differences in SEE yields are attributed to varying ionization potentials and molecular structures of the ionic liquids. These findings are essential for accurate modeling of plasma discharges and understanding SEE mechanisms in ionic liquids.

ionic liquids↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Quantitative temporally and spatially resolved X-ray fluorescence microprobe characterization of the manganese dissolution-deposition mechanism in aqueous Zn/α-MnO 2 batteries

Rechargeable aqueous Zn/α-MnO 2 batteries are a possible alternative to lithium ion batteries for scalable stationary energy storage applications due to their low cost, safety and environmentally benign components. A critical need for advancement of this battery system is a full understanding of the electrochemical reaction mechanisms, which remain unclear. In this report, operando , spatiotemporal resolved synchrotron X-ray fluorescence mapping measurements on a custom aqueous Zn/α-MnO 2 cell provided direct evidence of a Mn dissolution-deposition faradaic mechanism that governs the electrochemistry. Simultaneous visualization and quantification of the Mn distribution in the electrolyte revealed the formation of aqueous Mn species during discharge and depletion on charge. The findings are supported by ex situ transmission electron microscopy (TEM), X-ray diffraction, Mn K-edge X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) measurements. The elucidated mechanism is fundamentally different from the previously proposed Zn 2+ insertion or conversion reactions. These findings provide a foundation for developing dissolution- deposition chemistries suitable for scalable stationary energy storage with aqueous electrolyte.

25 ENERGY STORAGE↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Predicting core transport in ITER baseline discharges with neon injections

Achieving self-consistent performance predictions for ITER requires integrated modeling of core transport and divertor power exhaust under realistic impurity conditions. We present results from a systematic power-flow and impurity-content study for the ITER 15 MA baseline scenario constrained directly by existing SOLPS-ITER neon-seeded divertor solutions. Using the OMFIT STEP workflow, stationary temperature and density profiles are predicted with TGYRO for $1.5 \unicode{x2A7D} Z_\textrm{eff} \unicode{x2A7D} 2.5$, and the corresponding power crossing the separatrix $P_\textrm{sep}$ is evaluated. We find that $P_\textrm{sep}$ varies by more than a factor of 1.7 across this scan and matches the ${\sim}100$ MW SOLPS-ITER prediction when $Z_\textrm{eff} \simeq 1.6$ or when auxiliary heating is reduced to ${\sim}75\%$ of nominal. Rotation-sensitivity studies show that plausible variations in toroidal flow magnitude modify $P_\textrm{sep}$ by $\lesssim 20\%$, while AURORA modeling confirms that charge-exchange radiation inside the separatrix is dynamically negligible under predicted ITER neutral densities. These results identify a restricted compatibility window, $Z_\textrm{eff} \approx 1.6$ –1.75 and $0.75 \lesssim f_{P_\textrm{aux}} \unicode{x2A7D} 1.0$, in which core transport predictions remain aligned with neon-seeded divertor protection targets. This self-consistent, model-constrained framework provides actionable guidance for impurity control and auxiliary-heating scheduling in early ITER operation and supports future whole-device scenario optimization.

ITER↗

A Novel Framework for Parametric Analysis of Coastal Transition Zone Modeling

Abstract Vulnerability of coastal regions to extreme events motivates an operational coupled inland‐coastal modeling strategy focusing on the coastal transition zone (CTZ), an area between the coast and upland river. To tackle this challenge, we propose a top‐down framework for investigating the contribution of different processes to the hydrodynamics of CTZs with various geometrical shapes, different physical properties, and under several forcing conditions. We further propose a novel method, called tidal vanishing point (TVP), for delineating the extent of CTZs through the upland. We demonstrate the applicability of our framework over the United States East and Gulf coasts. We categorize CTZs in the region into three classes, namely, without estuary (direct river–coast connection), triangular‐, and trapezoidal‐shaped estuary. The results show that although semidiurnal tidal constituents are dominant in most cases, diurnal tidal constituents become more prevalent in the river segment as the discharge increases. Also, decreasing the bed roughness value promotes more significant changes in the results than increasing it by the same value. Additionally, the estuary promotes tidal energy attenuation and consequently decreases the reach of tidal signals through the upland. The proposed framework is generic and extensible to any coastal region.

Chegini, Taher↗