Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Power system applications of fiber optic sensors

This document is a progress report of work done in 1985 on the Communications and Control for Electric Power Systems Project at the Jet Propulsion Laboratory. These topics are covered: Electric Field Measurement, Fiber Optic Temperature Sensing, and Optical Power transfer. Work was done on the measurement of ac and dc electric fields. A prototype sensor for measuring alternating fields was made using a very simple electroscope approach. An electronic field mill sensor for dc fields was made using a fiber optic readout, so that the entire probe could be operated isolated from ground. There are several instances in which more precise knowledge of the temperature of electrical power apparatus would be useful. This report describes a number of methods whereby the distributed temperature profile can be obtained using a fiber optic sensor. The ability to energize electronics by means of an optical fiber has the advantage that electrical isolation is maintained at low cost. In order to accomplish this, it is necessary to convert the light energy into electrical form by means of photovoltaic cells. JPL has developed an array of PV cells in gallium arsenide specifically for this purpose. This work is described.

Johnston, A. R.↗

Dynamics of superfluid helium in zero gravity

The Spacelab 2 superfluid helium experiment was designed to: (1) examine the behavior of capillary waves and measure their velocity and dampling; (2) study the sloshing motion of bulk superfluid helium in near-zero gravity in order to determine its effects on sensors and attitude control systems for far infrared telescopes; and (3) determine the temperature distributions in the liquid and their correlation with bulk motion. The experiment system includes a helium cryostat with a sensor head and a microcomputer to provide electrical excitation and gather and transmit resultant responses to the experiment teams on the ground. Astronaut intervention is possible.

Mason, P. V.↗

Salinity surveys using an airborne microwave radiometer

The Barnes PRT-5 infrared radiometer and L-band channel of the multifrequency microwave radiometer are used to survey the distribution of surface water temperature and salinity. These remote sensors were flown repetitively in November 1971 over the outflow of the Mississippi River into the Gulf of Mexico. Data reduction parameters were determined through the use of flight data obtained over a known water area. With these parameters, the measured infrared and microwave radiances were analyzed in terms of the surface temperature and salinity.

Paris, J. F.↗

Remote monitoring system

A remote monitoring system for monitoring parameters of an underground asset, such as an electric cable system, a pipeline serving as a conduit for water, gas, oil, sewage, or the like. Parameter detectors, such as sensors that measure temperature, voltage, current, moisture, etc., are distributed along the asset to provide electrical signals that represent respective monitored parameters of the asset. An underground hub disposed in an underground vault, or manhole, through which the asset passes is coupled to the parameter detectors to acquire the signals provided by the parameter detectors. The hub includes a controller to provide data derived from the acquired signals, the data being transmitted to a remote central location by a transceiver, or modem, via LP-WAN communication. Signals from the transceiver are transmitted directly from underground.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of the MTC noise estimation with a coupled neutronic/thermal-hydraulic dedicated model - 'Closing the loop'

This paper investigates the reliability of different noise estimators aimed at determining the Moderator Temperature Coefficient (MTC) of reactivity in Pressurized Water Reactors. By monitoring the inherent fluctuations in the neutron flux and moderator temperature, an on-line monitoring of the MTC without perturbing reactor operation is possible. In order to get an accurate estimation of the MTC by noise analysis, the point-kinetic component of the neutron noise and the core-averaged moderator temperature noise have to be used. Because of the scarcity of the in-core instrumentation, the determination of these quantities is difficult, and several possibilities thus exist for estimating the MTC by noise analysis. Furthermore, the effect of feedback has to be negligible at the frequency chosen for estimating the MTC in order to get a proper determination of the MTC. By using an integrated neutronic/thermal- hydraulic model specifically developed for estimating the three-dimensional distributions of the fluctuations in neutron flux, moderator properties, and fuel temperature, different approaches for estimating the MTC by noise analysis can be tested individually. It is demonstrated that a reliable MTC estimation can only be provided if the core is equipped with a sufficient number of both neutron detectors and temperature sensors, i.e. if the core contain in-core detectors monitoring both the axial and radial distributions of the fluctuations in neutron flux and moderator temperature. It is further proven that the effect of feedback is negligible for frequencies higher than 0.1 Hz, and thus the MTC noise estimations have to be performed at higher frequencies. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

A concept for non-invasive temperature measurement during injection moulding processes

Current models of the injection moulding process insufficiently consider the thermal interactions between melt, solidified material and the mould. A detailed description requires a deep understanding of the underlying processes and a precise observation of the temperature. Because todays measurement concepts do not allow a non-invasive analysis it is necessary to find new measurement techniques for temperature measurements during the manufacturing process. In this work we present the idea of a set up for a tomographic ultrasound measurement of the temperature field inside a plastics melt. The goal is to identify a concept that can be installed on a specialized mould for the injection moulding process. The challenges are discussed and the design of a prototype is shown. Special attention is given to the spatial arrangement of the sensors. Besides the design of a measurement set up a reconstruction strategy for the ultrasound signals is required. We present an approach in which an image processing algorithm can be used to calculate a temperature distribution from the ultrasound scans. We discuss a reconstruction strategy in which the ultrasound signals are converted into a spartial temperature distribution by using pvT curves that are obtained by dilatometer measurements.

42 ENGINEERING↗

Augmented Method to Improve Thermal Data for the Figure Drift Thermal Distortion Predictions of the JWST OTIS Cryogenic Vacuum Test

The JWST Optical Telescope Element (OTE) assembly is the largest optically stable infrared-optimized telescope currently being manufactured and assembled, and is scheduled for launch in 2018. The JWST OTE, including the 18 segment primary mirror, secondary mirror, and the Aft Optics Subsystem (AOS) are designed to be passively cooled and operate near 45K. These optical elements are supported by a complex composite backplane structure. As a part of the structural distortion model validation efforts, a series of tests are planned during the cryogenic vacuum test of the fully integrated flight hardware at NASA JSC Chamber A. The successful ends to the thermal-distortion phases are heavily dependent on the accurate temperature knowledge of the OTE structural members. However, the current temperature sensor allocations during the cryo-vac test may not have sufficient fidelity to provide accurate knowledge of the temperature distributions within the composite structure. A method based on an inverse distance relationship among the sensors and thermal model nodes was developed to improve the thermal data provided for the nanometer scale WaveFront Error (WFE) predictions. The Linear Distance Weighted Interpolation (LDWI) method was developed to augment the thermal model predictions based on the sparse sensor information. This paper will encompass the development of the LDWI method using the test data from the earlier pathfinder cryo-vac tests, and the results of the notional and as tested WFE predictions from the structural finite element model cases to characterize the accuracies of this LDWI method.

Thermal Modeling↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Development of metal-ceramic coaxial cable Fabry-Pérot interferometric sensors for high temperature monitoring

Metal-ceramic coaxial cable Fabry-Pérot interferometric (MCCC-FPI) sensors have been developed using a stainless steel tube and a stainless steel wire as the outer and inner conductors, respectively; a tubular α-alumina insulator; and a pair of air gaps created in the insulator along the cable to serve as weak reflectors for the transmitting microwave (MW) signal. The MCCC-FPI sensors have been demonstrated for high temperature measurements using MW signals in a frequency range of 2–8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of the MW interferogram reflected from the pair of weak reflectors. The MW sensor exhibited excellent linear dependence of Δƒ on temperature; small measurement deviations (±2.7%); and fast response in a tested range of 200–500 °C. The MCCC has the potential for further developing multipoint FPI sensors in a single-cable to achieve in situ and continuous measurement of spatially distributed temperature in harsh environments.

47 OTHER INSTRUMENTATION↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Characterization of AlMn TES Impedance, Noise, and Optical Efficiency in the First 150 mm Multichroic Array for Advanced ACTPol

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.

Crowley, Kevin T.↗

Optical monitoring to detect contamination of power grid components

A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.

Mostafavi, Saman↗

Optical monitoring to detect contamination of power grid components

A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.

Mostafavi, Saman↗