Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2020 International Conference onEnvironmental Systems (ICES) paper number 128. This paper provides the technical background and performance results from the updated silver chloride (AgCl) NP/PU. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive-Dosing of Biocide in Spacecraft Potable Water Systems – Update 2022

A spacecraft water disinfection system suitable for extended length space exploration should meet a list of requirements. It should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon previously published work. This paper provides the technical background and performance results (wash testing and ongoing long-term silver ion release testing) from the silver chloride (AgCl) NP/PU composite foams. The goal of the project is to develop a stable and reliable passive-dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2023

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2022 International Conference on Environmental Systems (ICES) paper number 97. This paper provides the technical background and performance test results (ongoing long-term silver ion release testing and product variability testing) from the silver chloride (AgCl) NP/PU composite foams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2024

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2023 International Conference on Environmental Systems (ICES) paper number 251. This paper provides the technical background and performance results for the product variability testing and microbial check valve (MCV) testing of the silver chloride (AgCl) NP/PU composite foams, referred to as AgFoams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Real-Time Dose Prediction for Artemis Missions

As large solar energetic particle (SEP) events can add significant radiation dose to astronauts in a short period of time and even induce acute clinical responses during missions, they present a concern for manned space flight operation. To assist the operations team in modeling and monitoring organ doses and any possible acute radiation-induced risks to astronauts during SEP events in real time, ARRT (Acute Radiation Risks Tool) 1.0 has been developed and successfully tested for Artemis I mission. The ARRT 2.0 described in this work integrates an established SEP forecasting model – UMASEP-100, further enabling real-time dose prediction for the upcoming Artemis II and following missions. With the new module linking with UMASEP-100 outputs in real time, the total BFO doses of most significant events can be communicated at the time of onset and hours before the peak. This is based on a flux-dose formula identified from comparing UMASEP-100 results with transport calculation for the events during 1994-2013 and validated with events outside that period. ARRT 2.0 also shows capability to distinguish minor events from significant ones to screen false alarms that will cause disruptions for space activities. This improvement provides additional information for operational teams to make timely decisions in contingent scenarios of severe SEP events to mitigate radiation exposure.

S Hu↗

Real-Time Dose Prediction for Artemis Missions

As large solar energetic particle (SEP) events can add significant radiation dose to astronauts in a short period of time and even induce acute clinical responses during missions, they present a concern for manned space flight operation. To assist the operations team in modeling and monitoring organ doses and any possible acute radiation-induced risks to astronauts during SEP events in real time, ARRT (Acute Radiation Risks Tool) 1.0 has been developed and successfully tested for Artemis I mission. The ARRT 2.0 described in this work integrates an established SEP forecasting model – UMASEP-100, further enabling real-time dose prediction for the upcoming Artemis II and following missions. With the new module linking with UMASEP-100 outputs in real time, the total BFO doses of most significant events can be communicated at the time of onset and hours before the peak. This is based on a flux-dose formula identified from comparing UMASEP-100 results with transport calculation for the events during 1994-2013 and validated with events outside that period. ARRT 2.0 also shows capability to distinguish minor events from significant ones to screen false alarms that will cause disruptions for space activities. This improvement provides additional information for operational teams to make timely decisions in contingent scenarios of severe SEP events to mitigate radiation exposure.

Shaowen Hu↗

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials↗

Methods to Track Effective Doses from Airborne Radioactive Emissions for Compliance with 40 CFR 61, SUBPART H

US Department of Energy national laboratories can play an integral role in not only the advancement of science but also in the treatment of various medical conditions through research and development activities conducted at radioisotope production facilities. Here, a project has been underway at Oak Ridge National Laboratory since 2016 whose mission is to produce and supply the radioisotope 227 Ac, which is used in a radiopharmaceutical developed to treat certain types of prostate cancer and bone metastases. Production activities result in the environmental release of airborne radioactive emissions, which are governed by Clean Air Act regulations described in 40 CFR Part 61, Subpart H. Stack 3039, the source that emits radioactive effluents from 227 Ac production, is subject to additional requirements outlined in American National Standards Institute (ANSI) N13.1-1969 due to its grandfathered status. Radioactive emissions are limited to levels below those that would cause annual compliance dose standards for members of the public to be exceeded and stack 3039 to lose its grandfathered status. To allow for maximum production of 227 Ac without exceeding relevant dose limits, monthly tracking of project emissions and resulting CAP88-PC modeled effective doses to a maximally exposed individual have been implemented. Four years of tracking data were compiled and analyzed to identify additional methods that could be used to estimate project doses more frequently, potentially further optimizing 227 Ac production while maintaining compliance with applicable regulations.

atmospheric emissions↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Feature-agnostic metabolomics for determining effective subcytotoxic doses of common pesticides in human cells

Although classical molecular biology assays can provide a measure of cellular response to chemical challenges, they rely on a single biological phenomenon to infer a broader measure of cellular metabolic response. These methods do not always afford the necessary sensitivity to answer questions of subcytotoxic effects, nor do they work for all cell types. Likewise, boutique assays such as cardiomyocyte beat rate may indirectly measure cellular metabolic response, but they too, are limited to measuring a specific biological phenomenon and are often limited to a single cell type. For these reasons, toxicological researchers need new approaches to determine metabolic changes across various doses in differing cell types, especially within the low-dose regime. Here, the data collected herein demonstrate that LC-MS/MS-based untargeted metabolomics with a feature-agnostic view of the data, combined with a suite of statistical methods including an adapted environmental threshold analysis, provides a versatile, robust, and holistic approach to directly monitoring the overall cellular metabolomic response to pesticides. When employing this method in investigating two different cell types, human cardiomyocytes and neurons, this approach revealed separate subcytotoxic metabolomic responses at doses of 0.1 and 1 µM of chlorpyrifos and carbaryl. These findings suggest that this agnostic approach to untargeted metabolomics can provide a new tool for determining effective dose by metabolomics of chemical challenges, such as pesticides, in a direct measurement of metabolomic response that is not cell type-specific or observable using traditional assays.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation-induced genomic instability: radiation quality and dose response

Genomic instability is a term used to describe a phenomenon that results in the accumulation of multiple changes required to convert a stable genome of a normal cell to an unstable genome characteristic of a tumor. There has been considerable recent debate concerning the importance of genomic instability in human cancer and its temporal occurrence in the carcinogenic process. Radiation is capable of inducing genomic instability in mammalian cells and instability is thought to be the driving force responsible for radiation carcinogenesis. Genomic instability is characterized by a large collection of diverse endpoints that include large-scale chromosomal rearrangements and aberrations, amplification of genetic material, aneuploidy, micronucleus formation, microsatellite instability, and gene mutation. The capacity of radiation to induce genomic instability depends to a large extent on radiation quality or linear energy transfer (LET) and dose. There appears to be a low dose threshold effect with low LET, beyond which no additional genomic instability is induced. Low doses of both high and low LET radiation are capable of inducing this phenomenon. This report reviews data concerning dose rate effects of high and low LET radiation and their capacity to induce genomic instability assayed by chromosomal aberrations, delayed lethal mutations, micronuclei and apoptosis.

Review↗

Pathology effects at radiation doses below those causing increased mortality

Mortality data from experiments conducted at the Argonne National Laboratory (ANL) on the long-term effects of external whole-body irradiation on B6CF(1) mice were used to investigate radiation-induced effects at intermediate doses of (60)Co gamma rays or fission-spectrum neutrons either delivered as a single exposure or protracted over 60 once-weekly exposures. Kaplan-Meier analyses were used to identify the lowest dose in the ANL data (within radiation quality, pattern of exposure, and sex) at which radiation-induced mortality caused by primary tumors could be detected (approximately 1-2 Gy for gamma rays and 10-15 cGy for neutrons). Doses at and below these levels were then examined for radiation-induced shifts in the spectrum of pathology detected at death. To do this, specific pathology events were pooled into larger assemblages based on whether they were cancer, cardiovascular disease or non-neoplastic diseases detected within the lungs and pleura, liver and biliary tract, reproductive organs, or urinary tract. Cancer and cardiovascular disease were further subdivided into categories based on whether they caused death, contributed to death, or were simply observed at death. Counts of how often events falling within each of these combined pathology categories occurred within a mouse were then used as predictor variables in logistic regression to determine whether irradiated mice could be distinguished from control mice. Increased pathology burdens were detected in irradiated mice at doses lower than those causing detectable shifts in mortality-22 cGy for gamma rays and 2 cGy for neutrons. These findings suggest that (1) models based on mortality data alone may underestimate radiation effects, (2) radiation may have adverse health consequences (i.e. elevated health risks) even when mortality risks are not detected, and (3) radiation-induced pathologies other than cancer do occur, and they involve multiple organ systems.

Non-NASA Center↗

Radiation transport modeling and assessment to better predict radiation exposure, dose, and toxicological effects to human organs on long duration space flights

NASA is very interested in improving its ability to monitor and forecast the radiation levels that pose a health risk to space-walking astronauts as they construct the International Space Station and astronauts that will participate in long-term and deep-space missions. Human exploratory missions to the moon and Mars within the next quarter century, will expose crews to transient radiation from solar particle events which include high-energy galactic cosmic rays and high-energy protons. Because the radiation levels in space are high and solar activity is presently unpredictable, adequate shielding is needed to minimize the deleterious health effects of exposure to radiation. Today, numerous models have been developed and used to predict radiation exposure. Such a model is the Space Environment Information Systems (SPENVIS) modeling program, developed by the Belgian Institute for Space Aeronautics. SPENVIS, which has been assessed to be an excellent tool in characterizing the radiation environment for microelectronics and investigating orbital debris, is being evaluated for its usefulness with determining the dose and dose-equivalent for human exposure. Thus far. the calculations for dose-depth relations under varying shielding conditions have been in agreement with calculations done using HZETRN and PDOSE, which are well-known and widely used models for characterizing the environments for human exploratory missions. There is disagreement when assessing the impact of secondary radiation particles since SPENVIS does a crude estimation of the secondary radiation particles when calculating LET versus Flux. SPENVIS was used to model dose-depth relations for the blood-forming organs. Radiation sickness and cancer are life-threatening consequences resulting from radiation exposure. In space. exposure to radiation generally includes all of the critical organs. Biological and toxicological impacts have been included for discussion along with alternative risk mitigation methods--shielding and anti-carcinogens. c 2001. Elsevier Science Ltd. All rights reserved.

STS-91 Shuttle Project↗

Latent transforming growth factor beta1 activation in situ: quantitative and functional evidence after low-dose gamma-irradiation

The biological activity of transforming growth factor beta1 (TGF-beta) is controlled by its secretion as a latent complex in which it is noncovalently associated with latency-associated peptide (LAP). Activation is the extracellular process in which TGF-beta is released from LAP, and is considered to be a primary regulatory control. We recently reported rapid and persistent changes in TGF-beta immunoreactivity in conjunction with extracellular matrix remodeling in gamma-irradiated mouse mammary gland. Our hypothesis is that these specific changes in immunoreactivity are indicative of latent TGF-beta activation. In the present study, we determined the radiation dose response and tested whether a functional relationship exists between radiation-induced TGF-beta and collagen type III remodeling. After radiation exposures as low as 0.1 Gy, we detected increased TGF-beta immunoreactivity in the mammary epithelium concomitant with decreased LAP immunostaining, which are events consistent with activation. Quantitative image analysis demonstrated a significant (P=0.0005) response at 0.1 Gy without an apparent threshold and a linear dose response to 5 Gy. However, in the adipose stroma, loss of LAP demonstrated a qualitative threshold at 0.5 Gy. Loss of LAP paralleled induction of collagen III immunoreactivity in this tissue compartment. We tested whether TGF-beta mediates collagen III expression by treating animals with TGF-beta panspecific monoclonal antibody, 1D11.16, administered i.p. shortly before irradiation. Radiation-induced collagen III staining in the adipose stroma was blocked in an antibody dose-dependent manner, which persisted through 7 days postirradiation. RNase protection assay revealed that radiation-induced elevation of total gland collagen III mRNA was also blocked by neutralizing antibody treatment. These data provide functional confirmation of the hypothesis that radiation exposure leads to latent TGF-beta activation, support our interpretation of the reciprocal shift in immunoreactivity as evidence of activation, and implicate TGF-beta as a mediator of tissue response to ionizing radiation. The sensitivity of activation to low radiation doses points to a potential role for TGF-beta in orchestrating tissue response to oxidative stress. As such, radiation may be useful as a probe to delineate the consequences of latent TGF-beta activation in situ.

NASA Discipline Radiation Health↗

Simulated X-59 on- and off-Design Sonic Boom Levels in Realistic Atmospheres for Noise Dose Range Estimation

NASA is planning several community noise surveys across the USA using the X-59 low-boom aircraft. These surveys require a range of noise levels to resolve a dose-response relationship. The X-59 was designed to produce a shaped sonic boom with a Stevens’ Perceived Level (PL) of 75 dB or less across the boom carpet in a standard atmosphere. However, the X-59’s flight condition can be adjusted to produce levels other than 75 PLdB to obtain a range of doses during community testing. Simulated nearfield pressure waveforms of the X-59 C612A in its on-design condition (Mach 1.4 at 53,200 ft) and an off-design condition at a lower altitude (Mach 1.4 at 46,000 ft) were propagated using PCBoom through realistic atmospheres over the span of one year at several locations across the country. The predicted on-design and off-design boom levels and carpet widths are presented, resulting in a preliminary estimate of the dose range that the X-59 may produce. Future work is planned with additional off-design conditions to assess the true capable dose range of the X-59.

X-59↗

Dose-Response Data Collection Preparation for the NASA Quesst Mission With the X-59

Supersonic flight has the potential to cut travel times in half; however, community annoyance to sonic booms led to the ban on overland commercial supersonic flight by the Federal Aviation Administration in 1973. As part of its Quesst mission, NASA is developing the X-59 aircraft to demonstrate quiet supersonic flight and collect dose-response data to inform regulators in their efforts to establish noise standards to replace the current supersonic speed limit. This talk presents an overview of the NASA Quesst mission and poses some challenges in collecting and analyzing X-59 dose-response data. For the upcoming community flight campaign, the noise dose is the loudness of a supersonic overflight of the X-59 and the perceptual response from participants is captured via surveys after the flyover events. Establishing a relationship between noise dose and perceptual response will be a key product of these efforts.

X-59↗

Modeling Measurement Error in Dose-Response Models of Community Annoyance to Low-Noise Supersonic Flight

The primary research goal of the forthcoming NASA Quesst mission community test campaign is to collect representative community response data in support of the development of supersonic overflight noise certification standards. Beginning in 2026, NASA will fly the novel X-59 demonstrator aircraft over select communities in United States in order to demonstrate the possibility of low-noise supersonic flight over land and to collect objective measurements and subjective data on the perceptual experience of this new noise source. It is believed that a regression of a binary perceptual response (‘highly annoyed’ or ‘not’) on estimated noise levels (doses, measured in decibels) will provide a useful dose-response relationship for regulators. However, as these estimated doses will be subject to measurement error, naïve estimators of regression coefficients are inconsistent and slopes may be subject to attenuation bias. In this presentation, I contrast functional modeling of measurement error via simulation extrapolation (SIMEX) with structural Bayesian measurement error models. These methods are applied to available data collected during two NASA risk reduction studies in California in 2011 and Texas in 2018. I’ll conclude noting that in the presence of nonnegligible measurement errors, probabilities of annoyance may be overpredicted for low noise levels and underpredicted for high noise levels, therefore, methods of correcting for measurement error will be necessary to improve the utility of the dose-response relationship for policy-making purposes.

simulation↗