Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose response model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An advanced solid state pressure transducer for high reliability SSME application

New methods to advance the state-of-the-art of pressure sensors for the Space Shuttle Main Engine were demonstrated. The results of the feasibility and breadboard demonstration phase and the current status of the research development prototype follow-on phase are presented. A technology breakthrough utilizing silicon piezoresistive technology was achieved in the first phase. A transducer design concept for the SSME application utilizes packaging materials with similar thermal coefficients of expansion and maintains the transducer seals primarily in compression. The silicon chip design will provide dual sensing outputs with laser trimmable integrated compensating electronics. The silicon resistor ion implant dose was customized for the SSME temperature requirement. A basic acoustic modeling software program was developed to evaluate the frequency response characteristics for the package design.

Johnson, R. L.↗

A computational approach to the relationship between radiation induced double strand breaks and translocations

A theoretical framework is presented which provides a quantitative analysis of radiation induced translocations between the ab1 oncogene on CH9q34 and a breakpoint cluster region, bcr, on CH 22q11. Such translocations are associated frequently with chronic myelogenous leukemia. The theory is based on the assumption that incorrect or unfaithful rejoining of initial double strand breaks produced concurrently within the 200 kbp intron region upstream of the second abl exon, and the 16.5 kbp region between bcr exon 2 and exon 6 interact with each other, resulting in a fusion gene. for an x-ray dose of 100 Gy, there is good agreement between the theoretical estimate and the one available experimental result. The theory has been extended to provide dose response curves for these types of translocations. These curves are quadratic at low doses and become linear at high doses.

NASA Discipline Radiation Health↗

NASA GeneLab Platform Utilized for Biological Response to Space Radiation in Animal Models

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

Implementation of ALARA radiation protection on the ISS through polyethylene shielding augmentation of the Service Module Crew Quarters

With 5-7 month long duration missions at 51.6 degrees inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (CnHn) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

The potential impact of bystander effects on radiation risks in a Mars mission

Densely ionizing (high-LET) galactic cosmic rays (GCR) contribute a significant component of the radiation risk in free space. Over a period of a few months-sufficient for the early stages of radiation carcinogenesis to occur-a significant proportion of cell nuclei will not be traversed. There is convincing evidence, at least in vitro, that irradiated cells can send out signals that can result in damage to nearby unirradiated cells. This observation can hold even when the unirradiated cells have been exposed to low doses of low-LET radiation. We discuss here a quantitative model based on the a formalism, an approach that incorporates radiobiological damage both from a bystander response to signals emitted by irradiated cells, and also from direct traversal of high-LET radiations through cell nuclei. The model produces results that are consistent with those of a series of studies of the bystander phenomenon using a high-LET microbeam, with the end point of in vitro oncogenic transformation. According to this picture, for exposure to high-LET particles such as galactic cosmic rays other than protons, the bystander effect is significant primarily at low fluences, i.e., exposures where there are significant numbers of untraversed cells. If the mechanisms postulated here were applicable in vivo, using a linear extrapolation of risks derived from studies using intermediate doses of high-LET radiation (where the contribution of the bystander effect may be negligible) to estimate risks at very low doses (where the bystander effect may be dominant) could underestimate the true risk from low doses of high-LET radiation. It would be highly premature simply to abandon current risk projections for high-LET, low-dose radiation; however, these considerations would suggest caution in applying results derived from experiments using high-LET radiation at fluences above approximately 1 particle per nucleus to risk estimation for a Mars mission.

Non-NASA Center↗

LDEF: Dosimetric measurement results (AO 138-7 experiment)

One of the objectives of the AO 138-7 experiment on board the Long Duration Exposure Facility (LDEF) was a total dose measurement with Thermo Luminescent Detectors (TLD 100). Two identical packages, both of them including five TLD's inside various aluminum shields, are exposed to the space environment in order to obtain the absorbed dose profile. Radiation fluence received during the total mission length was computed, taking into account the trapped particles (AE8 and AP8 models during solar maximum and minimum periods) and the cosmic rays; due to the magnetospheric shielding the solar proton fluences are negligible on the LDEF orbit. The total dose induced by these radiations inside a semi infinite plane shield of aluminum are computed with the radiation transport codes available at DERTS. The dose profile obtained is in good agreement with the evaluation by E.V. Benton. TLD readings are performed after flight; due to the mission duration increase a post flight calibration was necessary in order to cover the range of the in flight induced dose. The results obtained, similar (plus or minus 30 percent) for both packages, are compared with the dose profile computation. For thick shields it seems that the measurements exceed the forecast (about 40 percent). That can be due to a cosmic ray and trapped proton contributions coming from the backside (assumed as perfectly shielded by the LDEF structure in the computation), or to an underestimate of the proton or cosmic ray fluences. A fine structural shielding analysis should be necessary in order to determine the origin of this slight discrepancy between forecast and in flight measurements. For the less shielded dosimeters, mainly exposed to the trapped electron flux, a slight overestimation of the dose (less than 40 percent) appears. Due to the dispersion of the TLD's response, this cannot be confirmed. In practice these results obtained on board LDEF, with less than a factor 1.4 between measurements and forecast, reinforce the validity of the computation methods and models used for the long term evaluation of the radiation levels (flux and dose) encountered in space on low inclination and altitude Earth orbits.

Bourrieau, J.↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

Single-dose mucosal replicon-particle vaccine protects against lethal Nipah virus infection up to 3 days after vaccination

Nipah virus (NiV) causes a highly lethal disease in humans who present with acute respiratory or neurological signs. No vaccines against NiV have been approved to date. Here, we report on the clinical impact of a novel NiV-derived nonspreading replicon particle lacking the fusion (F) protein gene (NiVΔF) as a vaccine in three small animal models of disease. A broad antibody response was detected that included immunoglobulin G (IgG) and IgA subtypes with demonstrable Fc-mediated effector function targeting multiple viral antigens. Single-dose intranasal vaccination up to 3 days before challenge prevented clinical signs and reduced virus levels in hamsters and immunocompromised mice; decreases were seen in tissues and mucosal secretions, critically decreasing potential for virus transmission. This virus replicon particle system provides a vital tool to the field and demonstrates utility as a highly efficacious and safe vaccine candidate that can be administered parenterally or mucosally to protect against lethal Nipah disease.

60 APPLIED LIFE SCIENCES↗

Calculation of Dose Deposition in 3D Voxels by Heavy Ions and Simulation of gamma-H2AX Experiments

The biological response to high-LET radiation is different from low-LET radiation due to several factors, notably difference in energy deposition and formation of radiolytic species. Of particular importance in radiobiology is the formation of double-strand breaks (DSB), which can be detected by -H2AX foci experiments. These experiments has revealed important differences in the spatial distribution of DSB induced by low- and high-LET radiations [1,2]. To simulate -H2AX experiments, models based on amorphous track with radial dose are often combined with random walk chromosome models [3,4]. In this work, a new approach using the Monte-Carlo track structure code RITRACKS [5] and chromosome models have been used to simulate DSB formation. At first, RITRACKS have been used to simulate the irradiation of a cubic volume of 5 m by 1) 450 1H+ ions of 300 MeV (LET 0.3 keV/ m) and 2) by 1 56Fe26+ ion of 1 GeV/amu (LET 150 keV/ m). All energy deposition events are recorded to calculate dose in voxels of 20 m. The dose voxels are distributed randomly and scattered uniformly within the volume irradiated by low-LET radiation. Many differences are found in the spatial distribution of dose voxels for the 56Fe26+ ion. The track structure can be distinguished, and voxels with very high dose are found in the region corresponding to the track "core". These high-dose voxels are not found in the low-LET irradiation simulation and indicate clustered energy deposition, which may be responsible for complex DSB. In the second step, assuming that DSB will be found only in voxels where energy is deposited by the radiation, the intersection points between voxels with dose > 0 and simulated chromosomes were obtained. The spatial distribution of the intersection points is similar to -H2AX foci experiments. These preliminary results suggest that combining stochastic track structure and chromosome models could be a good approach to understand radiation-induced DSB and chromosome aberrations.

Plante, I.↗

Predicting Cell Death and Mutation Frequency for a Wide Spectrum of LET by Assuming DNA Break Clustering Inside Repair Domains

The high relative biological effectiveness (RBE) of high charged and energy (HZE) particles for cell death, DNA mutations and cancer remain based on experimental data. In this work, we propose that the existence of DNA repair domains is sufficient to predict both cell death and mutation frequencies for any LET by only taking into account experimental data from low-LET, offering one mechanism for RBE across LET. We hypothesize that whenever multiple DNA double-strand breaks (DSBs) are generated within the same DNA repair domain, DSBs are actively regrouped for more efficient repair [1]. This hypothesis has been supported by the low-LET sublinear dose response observed at doses greater than ~1Gy for 53BP1 radiation-induced foci (RIF) reflecting increasing DSB/RIF with dose [2]. Previously, we modeled radiation-induced cell death of human breast cells by first inferring the size of these domains from the dose dependence of low-LET RIF, and by associating a lethality factor to the number of pairs of DSBs in each RIF [1]. In this work, we first integrate the new NASA computer models RITCARD (Relativistic Ion Tracks, Chromosome Aberrations, Repair, and Damage) [3] and BDSTracks (Biological Damage by Stochastic Tracks) for a more accurate microdosimetry and a better model of the nuclear organization to predict the location of DSBs. A large array of particles and energy are simulated, covering more than three orders of magnitude for LET (~1-1000 keV/µm). Next, we extend our previous model to predict mutation frequencies by assuming that clustered DSBs increase mutation probability, which is formalized by the mutation frequency being linearly dependent on both the number of DSBs and the number of pairs of DSBs inside individual RIF. Linear coefficients are estimated so that simulations predict accurately mutation frequencies observed in Chinese hamster cells exposed to low-LET. Keeping these coefficients unchanged, we then predict mutation frequencies induced by HZE by simulating DSBs and obtain RBEs for mutations and cell death following the expected experimental bell shape for LET dependence. We also observe an orientation effect that needs to be confirmed, showing different RBE depending on the angle of the HZE beam hitting the main axis of the cell.

Plante, Ianik↗

A Dose of Reality: Radiation Analysis for Realistic Human Spacecraft

INTRODUCTION As with most computational analyses, a tradeoff exists between problem complexity, resource availability and response accuracy when modeling radiation transport from the source to a detector. The largest amount of analyst time for setting up an analysis is often spent ensuring that any simplifications made have minimal impact on the results. The vehicle shield geometry of interest is typically simplified from the original CAD design in order to reduce computation time, but this simplification requires the analyst to "re-draw" the geometry with a limited set of volumes in order to accommodate a specific radiation transport software package. The resulting low-fidelity geometry model cannot be shared with or compared to other radiation transport software packages, and the process can be error prone with increased model complexity. The work presented here demonstrates the use of the DAGMC (Direct Accelerated Geometry for Monte Carlo) Toolkit from the University of Wisconsin, to model the impacts of several space radiation sources on a CAD drawing of the US Lab module. METHODS The DAGMC toolkit workflow begins with the export of an existing CAD geometry from the native CAD to the ACIS format. The ACIS format file is then cleaned using SpaceClaim to remove small holes and component overlaps. Metadata is then assigned to the cleaned geometry file using CUBIT/Trelis from csimsoft (Registered Trademark). The DAGMC plugin script removes duplicate shared surfaces, facets the geometry to a specified tolerance, and ensures that the faceted geometry is water tight. This step also writes the material and scoring information to a standard input file format that the analyst can alter as desired prior to running the radiation transport program. The scoring results can be transformed, via python script, into a 3D format that is viewable in a standard graphics program. RESULTS The CAD model of the US Lab module of the International Space Station, inclusive of all the racks and components, was simplified to remove holes and volume overlaps. Problematic features within the drawing were also removed or repaired to prevent runtime issues. The cleaned drawing was then run through the DAGMC workflow to prepare for analysis. Pilot tests modeling transport of 1GeV proton and 800MeV/A oxygen sources show that reasonable results are converged upon in an acceptable amount of overall computation time from drawing preparation to data analysis. The FLUKA radiation transport code will next be used to model both a GCR and a trapped radiation source. These results will then be compared with measurements that have been made by the radiation instrumentation deployed inside the US Lab module. DISCUSSION Early analyses have indicated that the DAGMC workflow is a promising toolkit for running vehicle geometries of interest to NASA through multiple radiation transport codes. In addition, recent work has shown that a realistic human phantom, provided via a subcontract with the University of Florida, can be placed inside any vehicle geometry for a combinatorial analysis. This added functionality gives the user the ability to score various parameters at the organ level, and the results can then be used as input for cancer risk models.

Barzilla, J. E.↗

Prostate Stereotactic Body Radiation Therapy: An Overview of Toxicity and Dose Response

Ultrahypofractionationed radiation therapy for prostate cancer is increasingly studied and adopted. The American Association of Physicists in Medicine Working Group on Biological Effects of Hypofractionated Radiotherapy therefore aimed to review studies examining toxicity and quality of life after stereotactic body radiation therapy (SBRT) for prostate cancer and model its effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

Effects of track structure and cell inactivation on the calculation of heavy ion mutation rates in mammalian cells

It has long been suggested that inactivation severely effects the probability of mutation by heavy ions in mammalian cells. Heavy ions have observed cross sections of inactivation that approach and sometimes exceed the geometric size of the cell nucleus in mammalian cells. In the track structure model of Katz the inactivation cross section is found by summing an inactivation probability over all impact parameters from the ion to the sensitive sites within the cell nucleus. The inactivation probability is evaluated using the dose-response of the system to gamma-rays and the radial dose of the ions and may be equal to unity at small impact parameters for some ions. We show how the effects of inactivation may be taken into account in the evaluation of the mutation cross sections from heavy ions in the track structure model through correlation of sites for gene mutation and cell inactivation. The model is fit to available data for HPRT mutations in Chinese hamster cells and good agreement is found. The resulting calculations qualitatively show that mutation cross sections for heavy ions display minima at velocities where inactivation cross sections display maxima. Also, calculations show the high probability of mutation by relativistic heavy ions due to the radial extension of ions track from delta-rays in agreement with the microlesion concept. The effects of inactivation on mutations rates make it very unlikely that a single parameter such as LET or Z*2/beta(2) can be used to specify radiation quality for heavy ion bombardment.

NASA Discipline Number 45-10↗

Investigating the Theranostic Potential of Elementally Matched [ 43 Sc]Sc-PSMA-617 and [ 47 Sc]Sc-PSMA-617

The theranostic approach, which employs diagnostic radiopharmaceuticals to select patients who would benefit from targeted radiotherapy agents, has become an invaluable strategy for effective medical care. Scandium radionuclides offer the advantage of forming elementally matched and chemically identical diagnostic and therapeutic compounds, making them ideal candidates for this strategy. PSMA-617 is an established prostate-specific membrane antigen targeting agent and can be used as a proof of concept to investigate 43 Sc, the diagnostic nuclide, and 47 Sc, the therapeutic nuclide, as a theranostic pair. Methods: Cellular uptake, competitive binding assays, and internalization studies were carried out using LNCaP or PC-3 cell lines. [ 43 Sc]Sc-PSMA-617 was used in PET imaging studies in LNCaP or PC-3 tumor models, with time points ranging from 1–9 h. LNCaP tumor-bearing mice injected with [ 47 Sc]Sc-PSMA-617 were imaged using SPECT up to 48 h. A longitudinal study was carried out using LNCaP tumor-bearing mice imaged with [ 43 Sc]Sc-PSMA-617 prior to receiving a therapeutic dose of [ 47 Sc]Sc-PSMA-617. Results: 43 Sc and 47 Sc were incorporated into PSMA-617 at radiochemical yields of >99%. Cellular uptake studies demonstrated high uptake and specificity to PSMA receptors for [ 47 Sc]Sc-PSMA-617. In vivo PET studies showed specificity of [ 43 Sc]Sc-PSMA-617 while SPECT studies demonstrated tumor retention of [ 47 Sc]Sc-PSMA-617 up to 48 h. [ 47 Sc]Sc-PSMA-617 demonstrated therapeutic efficacy by delaying tumor growth and increasing survival rates from a single administered dose in xenograft models. More importantly, the PET results from [ 43 Sc]Sc-PSMA-617 PET were highly correlated with the therapeutic response from [ 47 Sc]Sc-PSMA-617, showing that 43 Sc PET data can predict therapeutic outcomes in individual animals from 47 Sc agents, even in animals sharing a genetic background and implanted with tumors from the same cell line. Conclusions: Two chemically identical, PSMA-targeting radioscandium pharmaceuticals demonstrated in vivo stability, specificity and retention in PSMA+ tumor models. A theranostic study showed that a higher 43 Sc PET SUVmean was strongly correlated to therapeutic response from the 47 Sc agent, demonstrating that 43 Sc and 47 Sc can be used as an elementally matched theranostic pair.

Biodistribution↗

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗

Analysis of radiation risk from alpha particle component of solar particle events

The solar particle events (SPE) will contain a primary alpha particle component, representing a possible increase in the potential risk to astronauts during an SPE over the often studied proton component. We discuss the physical interactions of alpha particles important in describing the transport of these particles through spacecraft and body shielding. Models of light ion reactions are presented and their effects on energy and linear energy transfer (LET) spectra in shielding discussed. We present predictions of particle spectra, dose, and dose equivalent in organs of interest for SPE spectra typical of those occurring in recent solar cycles. The large events of solar cycle 19 are found to have substantial increase in biological risk from alpha particles, including a large increase in secondary neutron production from alpha particle breakup.

NASA Discipline Number 45-10↗