Search NASA⌕ Search

SEARCH · Search NASA

Results for “double mass analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Intensity Exercise Countermeasures does not Prevent Orthostatic Intolerance Following Prolonged Bed Rest

Approximately 20% of Space Shuttle astronauts became presyncopal during operational stand and 80deg head‐up tilt tests, and the prevalence of orthostatic intolerance increases after longer missions. Greater than 60% of the US astronauts participating in Mir and early International Space Station missions experienced presyncope during post‐flight tilt tests, perhaps related to limitations of the exercise hardware that prevented high intensity exercise training until later ISS missions. The objective of this study was to determine whether an intense resistive and aerobic exercise countermeasure program designed to prevent cardiovascular and musculoskeletal deconditioning during 70 d of bed rest (BR), a space flight analog, would protect against post‐BR orthostatic intolerance. METHODS Twenty‐six subjects were randomly assigned to one of three groups: non‐exercise controls (n=11) or one of two exercise groups (ExA, n=8; ExB, n=7). Both ExA and ExB groups performed the same resistive and aerobic exercise countermeasures during BR, but one exercise group received testosterone supplementation while the other received a placebo during BR in a double‐blinded fashion. On 3 d/wk, subjects performed lower body resistive exercise and 30 min of continuous aerobic exercise (≥75% max heart rate). On the other 3 d/wk, subjects performed only highintensity, interval‐style aerobic exercise. Orthostatic intolerance was assessed using a 15‐min 80 head‐up tilt test performed 2 d (BR‐2) before and on the last day of BR (BR70). Plasma volume was measured using carbon monoxide rebreathing on BR‐3 and before rising on the first recovery day (BR+0). The code for the exercise groups has not been broken, and results are reported here without group identification. RESULTS Only one subject became presyncopal during tilt testing on BR‐2, but 7 of 11 (63%) controls, 3 of 8 (38%) ExA, and 4 of 7 (57%) ExB subjects were presyncopal on BR70. Survival analysis of post‐BR tilt tests revealed no differences (p=0.77) between groups. Plasma volume (absolute or relative to body mass index) decreased (p<0.001) from pre to post‐BR, with no differences between groups. CONCLUSIONS These preliminary results corroborate previous reports that the performance of a vigorous exercise countermeasure protocol during BR, even with testosterone supplementation, does not protect against orthostatic intolerance or plasma volume loss. Preventing post‐BR orthostatic intolerance may require additional countermeasures, such as orthostatic stress during BR or end‐of‐BR fluid infusion.

Platts, Steven H.↗

Dramatic Rebrightening of the Type-changing Stripped-envelope Supernova SN 2023aew

Abstract Multipeaked supernovae with precursors, dramatic light-curve rebrightenings, and spectral transformation are rare, but are being discovered in increasing numbers by modern night-sky transient surveys like the Zwicky Transient Facility. Here, we present the observations and analysis of SN 2023aew, which showed a dramatic increase in brightness following an initial luminous (−17.4 mag) and long (∼100 days) unusual first peak (possibly precursor). SN 2023aew was classified as a Type IIb supernova during the first peak but changed its type to resemble a stripped-envelope supernova (SESN) after the marked rebrightening. We present comparisons of SN 2023aew’s spectral evolution with SESN subtypes and argue that it is similar to SNe Ibc during its main peak. P-Cygni Balmer lines are present during the first peak, but vanish during the second peak’s photospheric phase, before H α resurfaces again during the nebular phase. The nebular lines ([O i ], [Ca ii ], Mg i ], H α ) exhibit a double-peaked structure that hints toward a clumpy or nonspherical ejecta. We analyze the second peak in the light curve of SN 2023aew and find it to be broader than that of normal SESNe as well as requiring a very high 56 Ni mass to power the peak luminosity. We discuss the possible origins of SN 2023aew including an eruption scenario where a part of the envelope is ejected during the first peak and also powers the second peak of the light curve through interaction of the SN with the circumstellar medium.

Sharma, Yashvi (ORCID:0000000345311745)↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗

The Southern Hemisphere circulation during the FGGE and its representativeness

An analysis of the global redistribution of mass during the FGGE year indicates that the global circulation was highly anomalous in several respects, especially from April to July 1979. For the 56 to year period 1924-1980, sea-level pressures over the northern hemisphere during the FGGE year were second highest in spring and highest in summer. In April and June, the anomalies were 1-in-100-year events. At the same time, sea-level pressure deficits and an exceptionally deep circumpolar trough were recorded over the Southern Hemisphere. Such compensation between the hemispheres, through the constraint of conservation of mass, provides support for the highly typical nature of the circulation analyzed to exist over the Southern Hemisphere throughout the FGGE year. The Southern Hemisphere circulation was characterized by an exceptionally deep circumpolar trough, an increase in westerlies from 40 deg to 70 deg S, and a decrease in westerlies to the north. In winter, the subtropical jet was weaker and the polar jet stronger than normal, so that a pronounced double jet structure prevailed. In summer, the jet was shifted south by 3 deg latitude. A southward shift in storm tracks accompanied these changes year round in a manner consistent with theory.

Trenberth, K. E.↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

Determining the leading-order contact term in neutrinoless double β decay

We present a method to determine the leading-order (LO) contact term contributing to the nn → ppe - e - amplitude through the exchange of light Majorana neutrinos. Our approach is based on the representation of the amplitude as the momentum integral of a known kernel (proportional to the neutrino propagator) times the generalized forward Compton scattering amplitude n ( p 1 ) n ( p 2 ) W + ( k ) → \( p\left({p}_1^{\prime}\right)p\left({p}_2^{\prime}\right){W}^{-}(k) \) , in analogy to the Cottingham formula for the electromagnetic contribution to hadron masses. We construct model-independent representations of the integrand in the low- and high-momentum regions, through chiral EFT and the operator product expansion, respectively. We then construct a model for the full amplitude by interpolating between these two regions, using appropriate nucleon factors for the weak currents and information on nucleon-nucleon ( NN ) scattering in the 1 S 0 channel away from threshold. By matching the amplitude obtained in this way to the LO chiral EFT amplitude we obtain the relevant LO contact term and discuss various sources of uncertainty. We validate the approach by computing the analog I = 2 NN contact term and by reproducing, within uncertainties, the charge-independence-breaking contribution to the 1 S 0 NN scattering lengths. While our analysis is performed in the \( \overline{\mathrm{MS}} \) scheme, we express our final result in terms of the scheme-independent renormalized amplitude \( {\mathcal{A}}_{\nu}\left(\left|\mathbf{p}\right|,\left|\mathbf{p}^{\prime}\right|\right) \) at a set of kinematic points near threshold. We illustrate for two cutoff schemes how, using our synthetic data for \( {\mathcal{A}}_{\nu } \) , one can determine the contact-term contribution in any regularization scheme, in particular the ones employed in nuclear-structure calculations for isotopes of experimental interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design for Manufacturing of Structures with Automated Fiber Placement via Integration of Analysis and Process Planning

Under the Design for Manufacturing (DFM) task in the NASA HiCAM program, significant process has been made towards establishing a fully automated optimization process that spans the structural analysis, design, and manufacturing process planning for Automated Fiber Placement (AFP) structures. Previous efforts in this area established the data formats and mapping processes needed to exchange data between disciplines. The software tools used in the framework are HyperX (structural optimization), CAPP (process planning), and VCP (AFP path generation). The work has culminated with automation of data exchanges and an optimization process that drives the three software toward convergence. Within this framework, HyperX is used to generate mass-optimum composite designs which are iterated with VCP and CAPP to improve manufacturability of the designs. As the ply manufacturing process is adjusted by CAPP and VCP, HyperX continually re-assesses the structural integrity of the part and makes adjustments to the laminate as needed. For example, the position of fiber steering and tow overlaps/gaps can necessitate changes to the laminate design. Once the design converges, the end result is a stack of plies that meets both structural and manufacturing requirements. This paper presents the details of the framework and demonstrations the automated process on several parts with significant double-curvature.

HiCAM↗

Measurement of Υ production in pp collisions at $\sqrt{s}$ = 5 TeV

The production cross-sections of Υ mesons, namely Υ(1S), Υ(2S) and Υ(3S), in pp collisions at $\sqrt{s}$ = 5 TeV are measured with a data sample corresponding to an integrated luminosity of 9.13 ± 0.18 pb –1 collected by the LHCb detector. The Υ mesons are reconstructed in the decay mode Υ → μ + μ – . Double differential cross-sections times branching fractions, as functions of the transverse momentum p T and the rapidity y of the Υ mesons, are measured in the range p T < 20 GeV/c and 2.0 < y < 4.5. The results integrated over these p T and y ranges are $\sigma \left(\textrm{Y}(1S)\right)\times \mathcal{B}\left(\textrm{Y}(1S)\to {\mu}^{+}{\mu}^{-}\right)=2101\pm 33\pm 83\ \textrm{pb},$ $\sigma \left(\textrm{Y}(2S)\right)\times \mathcal{B}\left(\textrm{Y}(2S)\to {\mu}^{+}{\mu}^{-}\right)=526\pm 20\pm 21\ \textrm{pb},$ $\sigma \left(\textrm{Y}(3S)\right)\times \mathcal{B}\left(\textrm{Y}(3S)\to {\mu}^{+}{\mu}^{-}\right)=242\pm 16\pm 10\ \textrm{pb},$ where the first uncertainties are statistical and the second are systematic. The ratios of cross-sections between measurements of two different Υ states and between measurements at different centre-of-mass energies are determined. The nuclear modification factor of Υ(1S) at $\sqrt{s}$ = 5 TeV is updated as well using the directly measured cross-section results from this analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stellar Populations in Compact Galaxy Groups: a Multi-wavelength Study of HCGs 16, 22, and 42, Their Star Clusters, and Dwarf Galaxies

We present a multi-wavelength analysis of three compact galaxy groups, Hickson compact groups (HCGs) 16, 22, and 42, which describe a sequence in terms of gas richness, from space- (Swift, Hubble Space Telescope (HST), and Spitzer) and ground-based (Las Campanas Observatory and Cerro Tololo Inter-American Observatory) imaging and spectroscopy.We study various signs of past interactions including a faint, dusty tidal feature about HCG 16A, which we tentatively age-date at <1 Gyr. This represents the possible detection of a tidal feature at the end of its phase of optical observability. Our HST images also resolve what were thought to be double nuclei in HCG 16C and D into multiple, distinct sources, likely to be star clusters. Beyond our phenomenological treatment, we focus primarily on contrasting the stellar populations across these three groups. The star clusters show a remarkable intermediate-age population in HCG 22, and identify the time at which star formation was quenched in HCG 42. We also search for dwarf galaxies at accordant redshifts. The inclusion of 33 members and 27 "associates" (possible members) radically changes group dynamical masses, which in turn may affect previous evolutionary classifications. The extended membership paints a picture of relative isolation in HCGs 16 and 22, but shows HCG 42 to be part of a larger structure, following a dichotomy expected from recent studies. We conclude that (1) star cluster populations provide an excellent metric of evolutionary state, as they can age-date the past epochs of star formation; and (2) the extended dwarf galaxy population must be considered in assessing the dynamical state of a compact group.

Compact Galaxy↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present the whole tube and close-up XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

R A Zeigler↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. Last summer, NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This is a 30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a 60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution Xray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present a first look at the XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

Zeigler, R. A.↗

XMM-Newton and TESS observations of the highly variable polar V496 UMa

We studied the temporal and spectral behavior of V496 UMa from the optical to the X-ray regimes. Methods. We used archival XMM-Newton and TESS observations obtained in 2017 and 2019, respectively, to perform a spectral and timing analysis of the highly variable magnetic CV. Results. The light curves of the TESS and XMM-Newton satellites reveal a double-humped pattern modulated with the periodicity of 91.058467 ± 0.00001 min. V496 UMa displays a two-pole accretion geometry in the high accretion state. X-ray spectra from these regions are composed of thermal plasma radiation and soft blackbody components with almost identical temperatures and a total accretion rate of $\dot{M}$ = 1.4(8) × 10 -11 M ⊙ yr -1 . The X-ray centers of the humps show longitudinal shifts of -18° and 4°, and shifts around photometric phase zero of -172° and -186°, for the main hump and second hump, respectively. The long-term ZTF light curves reveal high and low accretions states. Low-state ZTF and SDSS photometric data are consistent with an 0.8 M ⊙ white dwarf at 10 000 K and a main-sequence donor star with a spectral type of M5.0 at a Gaia determined distance of 758 pc. Conclusions. V496 UMa is a very bright polar in X-rays when it is in the high state. Due to its unusual geometric structure, mass accretion onto the second accretion pole is interrupted occasionally. This discontinuous behavior does not follow a certain pattern in time and has been observed so far only in the high state. The X-ray light curves display clear evidence of an accretion stream at the photometric phase of φ = 0.81, which does not show up in optical light curves. An accurate period was derived using the combined TESS and XMM-Newton data, which differs by 3.8 σ from published results.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Non-homologous End Joining

Non-homologous end joining (NHEJ) is the dominant DNA double strand break (DSB) repair pathway and involves several NHEJ proteins such as Ku, DNA-PKcs, XRCC4, Ligase IV and so on. Once DSBs are generated, Ku is first recruited to the DNA end, followed by other NHEJ proteins for DNA end processing and ligation. Because of the direct ligation of break ends without the need for a homologous template, NHEJ turns out to be an error-prone but efficient repair pathway. Some mechanisms have been proposed of how the efficiency of NHEJ repair is affected. The type of DNA damage is an important factor of NHEJ repair. For instance, the length of DNA fragment may determine the recruitment efficiency of NHEJ protein such as Ku [1], or the complexity of the DNA breaks [2] is accounted for the choice of NHEJ proteins and subpathway of NHEJ repair. On the other hand, the chromatin structure also plays a role of the accessibility of NHEJ protein to the DNA damage site. In this talk, some mathematical models of NHEJ, that consist of series of biochemical reactions complying with the laws of chemical reaction (e.g. mass action, etc.), will be introduced. By mathematical and numerical analysis and parameter estimation, the models are able to capture the qualitative biological features and show good agreement with experimental data. As conclusions, from the viewpoint of modeling, how the NHEJ proteins are recruited will be first discussed for connection between the classical sequential model [4] and recently proposed two-phase model [5]. Then how the NHEJ repair pathway is affected, by the length of DNA fragment [6], the complexity of DNA damage [7] and the chromatin structure [8], will be addressed

Li, Yongfeng↗

Photoproduction of K0K0-bar with the GlueX Experiment

In this dissertation, we study photoproduction of K0 ?K 0 through the KSKLp and KSKSp ?nal states with the GlueX Phase-I (GlueX-I) data set. We measure the spin-density matrix elements (SDMEs) and di?erential cross section of ?(1020) ! KSKL to better understand photoproduction of light vector mesons. A mass independent Partial Wave Analysis (PWA) of the KSKL and KSKS meson spectrum below 2 GeV is also undertaken to study the meson spectrum with JPC = even++ and odd??. The ?(1020) di?erential cross section is measured at E = 8:2 ? 8:8 GeV and ?t = 0:15 ? 1:00 GeV2. The di?erential cross section is well described by an exponential decay with slope 4:44?0:01 GeV?2 and the integrated cross section is determined to be 295:7?0:4 nb, only statistical uncertainties are quoted. Both measurements are consistent and far more precise than the previous measurement by Ballam et al. [1]. The ?(1020) SDMEs were measured in nine bins of ?t in the same range. At low ?t, we ?nd the data were consistent with s-channel helicity conservation, SCHC, i. e. the only non-zero SDMEs were ?1 1?1 = ?Im(?2 1?1) = 1=2. At higher ?t, the SDMEs deviate from SCHC and the measurements indicate this is due to natural parity exchange since we observe that the SDMEs are consistent with zero unnatural exchange. We also ?find that the contribution from helicity double-flip amplitudes is consistent with zero. The measured SDMEs are in poor agreement with theoretical predictions put forward by JPAC [35]. These measurements will serve as input to re?ne models of production processes, which will be essential for the interpretation of possible signals of exotic mesons in GlueX. Analysis of the spectrum above the ?(1020) indicates the presence of at least three particles at ? 1:50, ? 1:75, and 2:20 GeV. We employ simple parametrizations of the resonance line shape based on relativistic Breit-Wigner functions considering cases with and without interference. The resonance at ? 1:50 GeV is not identifi?ed as any specifi?c resonance, but could be due to interference between the ?(1450) and !(1420). Our models favor the resonance at ~1:75 GeV as the X(1750) rather than the ?(1680). We ?find that introducing a third Breit-Winger into the models improves the ?t quality with the ?2/ndf going from 1.75 to 1.59 and 1.41 to 1.18 for models without and with interference respectively. A PWA of the KSKL spectrum indicates that the spectrum is consistent with exclusively spin-1 contribution up to ? 1:6 GeV. Above ? 1:6 GeV we ?find evidence for a small spin-3 contribution. We also ?nd that the spectrum predominantly positive reflectivity up to ? 1:6 GeV, after which the spectrum becomes a nearly equal mix of both. The KSKS system shows a rich spectrum with multiple resonance structures but is more statistically limited than the KSKL system. Modelling the line shape we ?find evidence at greater than 10? level in favor of a resonance at ? 1:75 GeV. The model parameters suggest this resonance is the f0(1710). The PWA of the KSKS system was inconclusive. However, using a small set of amplitudes suggests that the spin-2 contribution to the spectrum is primarily in the range 1:2?1:6 GeV, where f2(1270), a2(1320) and f02 (1525) are expected.

Linera, Gabriel Rodriguez↗

Vitamin E provides protection for bone in mature hindlimb unloaded male rats

The deleterious effects of skeletal unloading on bone mass and strength may, in part, result from increased production of oxygen-derived free radicals and proinflammatory cytokines. This study was designed to evaluate the ability of vitamin E (alpha-tocopherol), a free-radical scavenger with antiinflammatory properties, to protect against bone loss caused by skeletal unloading in mature male Sprague-Dawley rats. A 2 x 3 factorial design was used with either hindlimb unloading (HU) or normal loading (ambulatory; AMB), and low-dose (LD; 15 IU/kg diet), adequate-dose (AD; 75 IU/kg diet), or high-dose (HD; 500 IU/kg diet) vitamin E (DL-alpha-tocopherol acetate). To optimize the effects of vitamin E on bone, dietary treatments were initiated 9 weeks prior to unloading and continued during the 4-week unloading period, at which time animals were euthanized and blood and tissue samples were collected. Serum vitamin E was dose-dependently increased, confirming the vitamin E status of animals. The HD treatment improved oxidation parameters, as indicated by elevated serum ferric-reducing ability and a trend toward reducing tissue lipid peroxidation. Histomorphometric analysis of the distal femur revealed significant reductions in trabecular thickness (TbTh), double-labeled surface (dLS/BS), and rate of bone formation to bone volume (BFR/BV) due by HU. AMB animals on the HD diet and HU animals on the LD diet had reduced bone surface normalized to tissue volume (BS/TV) and trabecular number (TbN); however, the HD vitamin E protected against these changes in the HU animals. Our findings suggest that vitamin E supplementation provides modest bone protective effects during skeletal unloading.

NASA Discipline Musculoskeletal↗

Post-translational control of collagen fibrillogenesis in mineralizing cultures of chick osteoblasts

Cultured osteoblasts from chick embryo calvaria were used as a model system to investigate the post-translational extracellular mechanisms controlling the macroassembly of collagen fibrils. The results of these studies demonstrated that cultured osteoblasts secreted a collagenous extracellular matrix that assembled and mineralized in a defined temporal and spatial sequence. The assembly of collagen occurred in a polarized fashion, such that successive orthogonal arrays of fibrils formed between successive cell layers proceeding from the culture surface toward the media. Mineralization followed in the same manner, being observed first in the deepest and oldest fibril layers. Collagen fibrillogenesis, the kinetics of cross-link formation, and collagen stability in the extracellular matrix of the cultures were examined over a 30 day culture period. Between days 8 and 12 in culture, collagen fibril diameters increased from < 30 nm to an average of 30-45 nm. Thereafter, diameters ranged in size from 20 to 200 nm. Quantitation of the collagen cross-linking residues, hydroxylysyl pyridinoline (HP) and lysyl pyridinoline (LP), showed that these mature cross-links increased from undetectable levels to concentrations found in normal chick bone. Analysis of the kinetics of their formation by pulse-chase labeling the cultures with [3H]lysine showed a doubling time of approximately 5 days. The relationships between cross-link formation, fibrillogenesis, and collagen stability were examined in cultures treated with beta-aminopropionitrile (beta-APN), a potent inhibitor of lysyl oxidase and cross-link formation. In beta-APN-treated cultures, total collagen synthesis was increased twofold, with no change in mRNA levels for type I collagen, whereas the amount of collagen accumulated in the cell layer was decreased by 50% and mineral deposition was reduced. The rate of collagen retention in the matrix was assessed by pulse-chase analysis of [3H]proline over a 16 day period in control and beta-APN-treated cultures. In control cultures, about 20% of the labeled collagen was lost from the cell layers over a 16 day period compared with > 80% in the presence of beta-APN. The beta-APN-treated cultures also showed a wider diversity of fibril diameters with a median in the > 45-60 nm range. In summary, these data suggest that cross-linking and assembly of collagen fibrils secreted by osteoblasts in vitro occur in a fashion similar to that found in vivo. The rate of cross-link formation is relatively constant and may be correlated with increasing collagen mass.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Musculoskeletal↗

Cumulative short-lived photofission product yields for nuclear forensic application

Experiments have long been carried out with linear accelerator (linac) produced bremsstrahlung X-rays to study high-energy photon-induced fission, known as “photofission”. One benefit of photofission, when compared with neutron-induced fission, is the ability to investigate fundamental physics of fission at excitation energies lower than what is possible with neutrons [1]. Absorption of an incident neutron results in a compound nucleus with an excitation energy at least equal to the neutron binding energy; thus, the lowest energy region of the fission barrier cannot be studied. Fission product yield distributions are dependent on the incident particle energy and the target nucleus mass. They are generally represented by a double-humped curve, with low and high mass “peaks” and an intermediate mass “valley”. As incident particle energy increases, the excitation energy of the nucleus increases, thereby increasing the overall yield of isotopes in the valley with respect to the two maxima or peaks of the fission product curve [3]. Photofission is most probable for incident photons around 14 MeV due to the giant dipole resonance. Induced photofission around this energy results in a fission product yield distribution that resembles 14 MeV DT neutron fission more than thermal or fast (500 keV) neutron fission. In post-detonation nuclear forensics, the peak-to-valley ratio of the fission product yield curve could be used for characterizing device type by providing an indication of the neutron energy spectrum that had induced fission (e.g., 500 keV vs. 14 MeV). The goal of this work is to improve nuclear data for isotopes of interest in nuclear forensics and special nuclear material (SNM) detection, specifically the fission product yield data via photofission experiments for the isotopes of 238U and 232Th. Photofission has been proposed as a less costly and more flexible production method for the valley isotopes that are representative of DT neutron fission product yield distributions, which would benefit nuclear forensics exercises in testing for analysis techniques. Natural uranium and thorium targets were irradiated with bremsstrahlung photons (nominal endpoint energies of 8, 14, and 20 MeV), generated via impingement of high-energy electrons on a tungsten electron-to-photon radiator. Gamma-ray spectroscopy was used to observe and identify the decay of the resulting fission products. The photofission yields of 102 fission products were measured for the set of the 238U and 232Th targets at the three bremsstrahlung X-ray endpoint energies 8, 14, and 20 MeV. These fragments included masses ranging from A=84 to A=144, with half-lives as short as 1.07 seconds.

07 ISOTOPE AND RADIATION SOURCES↗