Search NASA⌕ Search

SEARCH · Search NASA

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present the whole tube and close-up XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

R A Zeigler↗

Mixing levels, the Apennine Front soil component, and compositional trends in the Apollo 15 soils

New compositional data (by INAA) for 29 samples of Apollo 15 soil fractions are presented along with data for six depth intervals of the bottom half of the double drive tube at station 2 on the Apennine Front. The compositional trends in the Apollo 15 soils are discussed in terms of four techniques used to determine the important components of the regolith: graphical techniques, factor analysis, chemical analysis of individual soil particles, and mixing models. The concept of 'mixing levels' is introduced, which states that a sample of lunar regolith can be considered as a mixture on several different compositional levels (I, igneous rock types; II, local rock types; III, soils), and it is shown that most attempts at modeling lunar soils as mixtures have been directed at level II. It is argued that only four components are required to account for the variation in concentrations of lithophile elements in the Apollo 15 samples: mare basalt, KREEP basalt, green glass, and Apennine front soil (best represented by the station 2 samples).

Korotev, Randy L.↗

Ammonia 15N/14N Isotope Ratio in the Jovian Atmosphere

Data from the Galileo Probe Mass Spectrometer has been used to derive the N-15/N-14 isotope ratio in ammonia at Jupiter. Although the mass spectral interference from the water contribution to 18 amu makes an accurate derivation of the (N-15)H3/(N-14)H3 ratio difficult from measurements of the singly ionized signals at 18 and 17 amu, this interference is not present in the doubly charged 8.5 and 9.0 amu signals from (N-14)H3++ and (N-15)H3++ respectively. Although the count rate from the 9 amu signal is low during the direct sampling of the atmosphere, the ammonia signal was considerably enhanced during the first enrichment cell (EC1) experiment that measured gas sampled between 0.8 and 2.8 bar. Count rates at 9 amu in the EC1 experiment reach 60/second and measure ammonia sampled from 0.88 to 2.8 bar. In the EC1 measurements the 8.5 amu signal is not measured directly, but can be calculated from the ammonia contribution to 17 amu and the ratio of NH3 ions of a double to single charged observed during a high resolution mass scan taken near the end of the descent. The high resolution scan gives this ratio from ammonia sampled much deeper in the atmosphere. These results are described and compared with Infrared Space Observatory-Short Wavelength Spectrometer (ISO-SWS) observations that give this ratio at 400 mbar.

Mahaffy, P.R.↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗

Simple collimator for use with diamond-anvil cells in a synchrotron beam

A simple double-slit system is described which allows a synchrotron beam to be collimated onto a small sample (approximately 150-micron diameter) in a diamond-anvil cell using remote control. The apparatus can be constructed easily and inexpensively, and allows the shutter positions to be monitored accurately using readily available electronic equipment. A desirable feature of the collimator is the relatively small time needed for adjustment.

Spain, I. L.↗

Dynamic response and acoustic fatigue of stiffened composite structure

The results of acoustic fatigue and dynamic response tests performed on L-1011 graphite-epoxy (GrE) aileron and panel components are reported. The aileron featured glass microballoons between the GrE skins. Tests yielded random fatigue data from double and single cantilever coupons and modal data from impedance hammer and loudspeaker impulses. Numerical and sample test data were obtained on combined acoustic and shear loads, acoustic and thermal loads, random fatigue and damping of the integrally stiffened and secondary bonded panels. The fatigue data indicate a fatigue life beyond 10 million cycles. The acoustic data suggested that noise transmission could be enhanced in the integrally stiffened panels, which were more acoustic-fatigue resistant than were the secondary bonded panels.

Soovere, J.↗

Small-scale physics of the ocean

Observations and theoretical models of small-scale phenomena in the oceans are reviewed, with a focus on progress during the period 1983-1986. Topics examined include surface layers, equatorial turbulence, off-equator mixed layers, the scaling of mixing, turbulence concepts, laboratory results, internal waves and mixing, rings, the nature of the bottom layer, double diffusion and intrusions, salt fingers, and biological interactions. Also discussed are developments in instrumentation (fast sampling profilers with upward-profiling capability, deep profilers, ship-motion correction, horizontal samplers, small submersibles, submarines, towed packages, conductivity sensors, dissolved-oxygen sensors, and acoustic Doppler current profilers) and goals for future research.

Caldwell, Douglas R.↗

Double-beam optical method and apparatus for measuring thermal diffusivity and other molecular dynamic processes in utilizing the transient thermal lens effect

A sample material was irradiated by relatively high power, short pulses from a dye laser. Energy from the pulses was absorbed by the sample material, thereby forming a thermal lens in the area of absorption. The pulse repetition rate was chosen so that the thermal lens is substantially dissipated by the time the next pulse reaches the sample material. A probe light beam, which in a specific embodiment is a relatively low power, continuous wave (cw) laser beam, irradiated the thermal lens formed in the sample material. The intensity characteristics of the probe light beam subsequent to irradiation of the thermal lens is related to changes in the refractive index of the sample material as the thermal lens is formed and dissipated.

Moacanin, J.↗

Preliminary Examination Process of Apollo Core 73002 - Insights and Lessons Learned From ANGSA for Future Sample Return Missions

Apollo Sample 73002 is part of a 2-foot long “drive tube” (73001/73002) of regolith that was collected from a landslide deposit near Lara Crater at the Apollo 17 site, Station 3. The double drive tube is believed to have penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the TLV [1]. As part of the ANGSA (Apollo Next Generation Sample Analyses) initiative, preparing preliminary examination (PE) catalog of 73002 is a crucial first step for the early identification of material types such as rock fragments, and potential stratigraphy within the core. PE of Apollo core 73002 is distinct from science activities with the main goal to produces a sample catalog with a level of detail about sample characterization that is sufficient for the ANGSA PIs (and later on the lunar sample community) to select and request the samples to conduct their individual, scientific studies. Ultimately, the PE catalog of 73002 will help to establish a better understanding of the stratigraphy of the land slide deposit; the processes of the landslide including the trigger(s) and possibly number of landslide events, as well as the role of volatiles [1] and will aid in the careful preservation of the material for future studies [2].

Apollo↗

Double phase-lock loop with rapid transient response - A concept

Integration loop, with narrow bandwidth and long response time, integrates phase estimate of sampling loop, resulting in slower but less jittery response to phase step changes. Sampling loop has wide bandwidth and quick response to phase steps of burst sync interval.

Balcewicz, J. F.↗

Time domain period determination techniques

Two simple period determination schemes are discussed. They are well suited to problems involving non-sinusoidal periodic phenomena sampled at a few irregularly spaced points. Statistical properties are discussed. The techniques are applied to the double mode Cepheids BK Cen and TU Cas as test cases.

Stellingwerf, R. F.↗

Evacuation-induced pressure differentials in multilayer insulation systems

The pressure differentials induced across three types of multilayer insulation systems during evacuation have been measured and compared with values predicted using an idealized parallel plate geometric model. The systems tested were double-aluminized Mylar with a Tissuglas or silk net spacer and crinkled single-aluminized Mylar. Test samples were circular. The influence of purge gas type, layer density, sample diameter, and temperature was systematically investigated. The experimental approach was to measure the absolute pressure history and corresponding pressure differential induced across the insulation during evacuation. The measured pressure differentials were nondimensionalized and compared with those predicted by the parallel plate model as a function of Knudsen number. It was concluded that the parallel plate model is adequate for making engineering analyses. The influence of all parameters, except layer density, is well represented by the model. Representation of the influence of layer density is less satisfactory, but can be improved by modification of the flat plate model to allow for the more obvious practical nonidealities, such as crinkling, or the presence of a net spacer.

Glassford, A. P. M.↗

Static and dynamic strain energy release rates in toughened thermosetting composite laminates

In this work, the static and dynamic fracture properties of several thermosetting resin based composite laminates are presented. Two classes of materials are explored. These are homogeneous, thermosetting resins and toughened, multi-phase, thermosetting resin systems. Multi-phase resin materials have shown enhancement over homogenous materials with respect to damage resistance. The development of new dynamic tests are presented for composite laminates based on Width Tapered Double Cantilevered Beam (WTDCB) for Mode 1 fracture and the End Notched Flexure (ENF) specimen. The WTDCB sample was loaded via a low inertia, pneumatic cylinder to produce rapid cross-head displacements. A high rate, piezo-electric load cell and an accelerometer were mounted on the specimen. A digital oscilloscope was used for data acquisition. Typical static and dynamic load versus displacement plots are presented. The ENF specimen was impacted in three point bending with an instrumented impact tower. Fracture initiation and propagation energies under static and dynamic conditions were determined analytically and experimentally. The test results for Mode 1 fracture are relatively insensitive to strain rate effects for the laminates tested in this study. The test results from Mode 2 fracture indicate that the toughened systems provide superior fracture initiation and higher resistance to propagation under dynamic conditions. While the static fracture properties of the homogeneous systems may be relatively high, the apparent Mode 2 dynamic critical strain energy release rate drops significantly. The results indicate that static Mode 2 fracture testing is inadequate for determining the fracture performance of composite structures subjected to conditions such as low velocity impact. A good correlation between the basic Mode 2 dynamic fracture properties and the performance is a combined material/structural Compression After Impact (CAI) test is found. These results underscore the importance of examining rate-dependent behavior for determining the longevity of structures manufactured from composite materials.

Cairns, Douglas S.↗

Integrated Analysis of Interferometric SAR, Satellite Altimetry and Hydraulic Modeling to Quantify Louisiana Wetland Dynamics

Wetland loss in Louisiana has been accelerating due primarily to anthropogenic and nature processes, and is being advocated as a problem with national importance. Accurate measurement or modeling of wetland-wide water level changes, its varying extent, its storage and discharge changes resulting in part from sediment loads, erosion and subsidence are fundamental to assessment of hurricane-induced flood hazards and wetland ecology. Here, we use innovative method to integrate interferometric SAR (InSAR) and satellite radar altimetry for measuring absolute or geocentric water level changes and applied the methodology to remote areas of swamp forest in coastal Louisiana. Coherence analysis of InSAR pairs suggested that the HH polarization is preferred for this type of observation, and polarimetric analysis can help to identi:fy double-bonnce backscattering areas in the wetland. Envisat radar altimeter-measured 18- Hz (along-track sampling of 417 m) water level data processed with regional stackfile method have been used to provide vertical references for water bodies separated by levees. The high-resolution (approx.40 m) relative water changes measured from ALOS PALSAR L-band and Radarsat-l C-band InSAR are then integrated with Envisat radar altimetry to obtain absolute water level. The resulting water level time series were validated with in situ gauge observations within the swamp forest. Furthermore, we compare our water elevation changes with 2D flood modeling from LISFLOOD hydrodynamic model. Our study demonstrates that this new technique allows retrospective reconstruction and concurrent monitoring of water conditions and flow dynamics in wetlands, especially those lacking gauge networks.

Lee, Hyongki↗

Disturbance Distance: Quantifying Forests' Vulnerability to Disturbance Under Current and Future Conditions

Disturbances, both natural and anthropogenic, are critical determinants of forest structure, function, and distribution. The vulnerability of forests to potential changes in disturbance rates remains largely unknown. Here, we developed a framework for quantifying and mapping the vulnerability of forests to changes in disturbance rates. By comparing recent estimates of observed forest disturbance rates over a sample of contiguous US forests to modeled rates of disturbance resulting in forest loss, a novel index of vulnerability, Disturbance Distance, was produced. Sample results indicate that 20% of current US forestland could be lost if disturbance rates were to double, with southwestern forests showing highest vulnerability. Under a future climate scenario, the majority of US forests showed capabilities of withstanding higher rates of disturbance then under the current climate scenario, which may buffer some impacts of intensified forest disturbance.

Dolan, Katelyn A.↗

Noble gases in 60009-60010 drive tube samples - Trapped gases and irradiation history

Concentrations and isotopic composition of noble gases are reported for grain size separates: nine soils from the 60010-60009 double drive tube, two soils from the 60007 drill core section, and surface soil 65501. Data are reported on concentrations of solar wind gases, surface-correlated gases (involving solar wind and lunar atmosphere), surface maturity indices, cosmogenic gases, possible soil mixing, and irradiation by cosmic rays. Good correlation is found between solar wind gases in 60009 soils and such surface maturity indices as petrographic agglutinates, magnetic soil fraction, and fine-grained iron. Cosmogenic He-3, Ne-21, Ar-38, Kr-80, and Xe-126 all display close correlations in the drive tube soils.

Bogard, D. D.↗

Analysis of X-Ray Microradiographs of Al-Au Interface Quench Profile using Modeling of Solidification Including Double-Diffusion and Convection in the Melt

Experimental data on Al-0.8Au horizontal solidification of a 1 mm thick specimen in a BN crucible shows the effect of growth rate on the solidification interface shape. For translation rates below 0.5 micron/s the interface maintains a plain and flat shape. When the translation rate is 3 to 5 micron/s or more, the interface appearance changes to two planar zones, with the zone closer to the bottom having higher inclination. The interface shapes were measured by first quenching in place during growth. X-ray microscopy shows the interface shape within the quenched sample by viewing through the side of the specimen. In order to provide theoretical explanation of the phenomena, numerical modeling was undertaken using finite element code FIDAP. Double diffusion convection in Al-0.8Au melt and crystal-melt interface curvature during directional solidification was analyzed numerically. Actual thermophysical properties of Al-0.8Au including the binary Al-Au phase diagram were used. Although convection in the sample is weak, for the slower translation rate convection and diffusion is sufficient for the redistribution of initial compositional stratification caused by gravity. When translation rate is raised, neither convection nor diffusion can provide proper mixing so that solidification temperatures differ significantly near the bottom within the bulk of the sample. As a result, the solid-liquid interface appears to have two planar zones with different inclination.

Bune, Andris V.↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the Moon. Although most Apollo samples are well characterized, several types of samples remain wholly or largely unstudied since their return: unopened and/or sealed drive tube samples, samples frozen upon return, and samples stored in a He-purged environment. NASA selected nine teams to participate in the Apollo Next Generation Sample Analysis (ANGSA) Program to study representative samples from each of these categories. The first sample studied as part of the ANGSA program is drive tube 73002, a 4 cm diameter unopened (but unsealed) drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube, and the bottom half of the tube (73001)was sealed under vacuum on the Moon (and will be studied next). As part of the preliminary examination of sample 73002, the entire drive tube was imaged with a high resolution X-ray Computed Tomography (XCT) scan prior to opening and dissecting the sample. Additionally, >50 XCT scans have been made of “large” clasts (>4 mm) removed from the core as part of the ongoing dissection process. Here we will present both the whole drive tube XCT data showing the overall structure of sample 73002 prior to dissection, as well as XCT scans of individual clasts that reveal the types and abundance of different lithologies present within the drive tube. We will also discuss the utility of the scans as part of the curation and preliminary examination process, as well as the potential for future science returns from the XCT scans.

Ryan A Zeigler↗