Search NASA⌕ Search

SEARCH · Search NASA

Results for “economic energy dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Dynamic Optimal Dispatch of Energy Systems with Intermittent Renewables and Damage Model

With the increasing penetration of intermittent renewable energy sources into the grid, there is a growing need for process systems-based strategies that integrate dispatchable and variable energy systems for supplying the demand while maintaining grid reliability. The proposed framework corresponds to a dynamic mixed-integer linear programming optimization approach that integrates coal-fired and natural gas-fired power plants, NaS batteries for energy storage, and solar/wind energy to supply the demand. This optimization approach considers an economic goal and constraints to provide power balance while maintaining the overall damage of the natural gas combined cycle (NGCC) power plant drum under a maximum stress as well as avoiding the overheating of the NGCC superheater and reheater. Renewable curtailment levels are also retained at minimum levels. Case studies are analyzed considering different loads and renewable penetration levels. The results show that the demand was met for all cases. Grid flexibility was mostly provided by the NGCC, while the batteries were used sparingly. In addition, considering a CO 2 equivalent analysis, the environmental performance was intrinsically connected to grid flexibility and the level of renewable penetration. Stress analysis results reinforced the necessity for an equipment health-related constraint.

97 MATHEMATICS AND COMPUTING↗

System and Component Development of Particle-Based Pumped Thermal Energy Storage

Reliable power supply from variable renewable resources requires energy storage at various scales to overcome resource intermittency. Long-duration energy storage (LDES, 10-100 hours) can improve dispatchability and grid reliability with increasing levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus has the potential to meet the LDES need and provide charging and discharging durations beyond the economic capacity of conventional batteries. TES technology has evolved from concentrating solar thermal power (CSP) generation and is recognized as an economic large-scale energy storage method. A standalone electric-thermal energy storage system supporting renewable integration of wind and solar power without CSP solar field can firm renewable generation and boost overall grid resilience and security.

concentrating solar thermal power↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

REDLY

SAND2025-11838O REDLY provides a framework for designing, training, and validating physics-informed neural networks for power system applications. It trains surrogates for Alternating Current Power Flow prediction and general economic dispatch problems, such as Alternating Current Optimal Power Flow and Direct Current Power Flow. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Blakely, Logan↗

Learning-Based Building Flexibility Estimation and Control to Improve Microgrid Economics and Resilience: Preprint

This paper proposes a learning-based building flexibility estimation and control framework to improve system economics and resilience. A data-driven building load flexibility model consisting of weather forecasting and estimating load consumption is proposed to quantify building heating, ventilation, and air conditioning (HVAC) load flexibility. A reinforcement learning-based microgrid controller is proposed to dispatch distributed generators, distributed energy resources, and build HVAC loads while taking flexibility information as one of the inputs. Simulation analysis is conducted on the model of a real microgrid in California. The effectiveness of the proposed learning-based building flexibility estimation and control in reducing microgrid energy costs and improving the sustainability of critical loads is demonstrated.

building load flexibility↗

The importance of capturing power system operational details in resource adequacy assessments

Traditional methods for assessing the resource adequacy (RA) of a power system are becoming obsolete due to emerging trends such as the increasing deployment of variable renewable energy and storage. Consequently, analysts are recommending that RA be assessed using a Monte Carlo simulation approach that models chronological power system operations over many instances of possible operating conditions. However, this approach is necessarily more complex and computationally demanding, which is an obstacle to real-world implementation. Here, in this study, we investigate which operational details of power systems are important to capture in order to accurately evaluate a system's RA, versus details that add complexity but do not meaningfully affect RA results. To do so, we develop a probabilistic RA assessment framework by adapting an existing production cost model and apply it to a case study based on the IEEE Reliability Test System. Our results indicate that multi-year data, storage dispatch, and transmission limits are key details to incorporate. Accurate RA results can be obtained using non-economic dispatch strategies as long as they are coordinated with detailed operational strategies. We also demonstrate how popular expectation-based RA metrics can mask important differences in the characteristics of loss of load events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Role of Hydropower Flexibility in Integrating Renewables in a Low-Carbon Grid

In this study, we looked at the role of hydropower flexibility in variable renewable energy (VRE) integration. Our focus was on facilities that have at least ten hours of storage, i.e., plants that are "dispatchable" and have capacity values similar to that of fossil-fired generation. For our modeling framework, we used NREL's Mid-Case/95% Carbon Reduction by 2035 standard scenario as our foundation. This zonal model is representative of the buildout of a near-zero carbon policy grid in an otherwise "business-as-usual" policy and economic environment. We chose this scenario because it aligns well with the Administration's net-zero carbon grid by 2035 goal.

13 HYDRO ENERGY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

The Internal Compound Parabolic Concentrator (ICPC): a Novel Low Cost Solar Thermal Collection System for Desalination Processes

The research team at UC Merced designed, prototyped, and tested (1) a novel low cost non-tracking solar thermal collector/concentrator called the Integrated Compound Parabolic Concentrator (ICPC) and (2) a low-cost phase-change thermal energy storage system. Together these technologies can significantly reduce the levelized cost of heat from solar thermal sources while also incorporating features of dispatchability and portability. The ICPC allows elevated temperature and efficiency in a low cost, non-tracking collector. The collector has demonstrated 60% ±4% solar to thermal modules efficiency at fluid outlet temperature of 120°C. The raw material cost of the collector system is reduced by utilizing low cost aluminum minichannels. The collector design is also amenable to economic mass production. A 200 tube, 10 kW prototype array was constructed and tested, yielding over 6 kWh/day on average at outlet fluid temperature exceeding 120°C.

14 SOLAR ENERGY↗

A Model for Evaluating the Configuration and Dispatch of PV Plus Battery Power Plants

An open-source model was developed to optimize energy storage operation for photovoltaic- (PV-) plus-battery systems with AC-coupled and DC-coupled configurations. It includes the ability to use forecast energy prices to optimize battery charge and discharge on a rolling time horizon. The model allows for exploration of different configurations, including capital costs, inverter performance, dispatch flexibility, and capturing otherwise clipped energy for the DC-coupled system. The model can run 20 full years of hourly data in approximately two seconds, allowing comparison of a large number of configurations. We applied the model in a test case demonstrating reduced inverter clipping for DC-coupled systems and yielded slightly higher overall value than AC-coupled systems, with an approximately 2 percent increase in internal rate of return or benefit/cost ratio. Our results show that at current estimated prices for lithium-ion battery systems, large-scale PV-plus-battery plants are economically viable under the right conditions, with the configuration playing a role in system flexibility and performance. This model provides the ability for project developers, industry professionals, and researchers to use readily available software to quickly evaluate and design these systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Potential of Hydrogen in a Decarbonized Future

Green hydrogen has become an interesting opportunity for utilities especially while considering a decarbonized future. This presentation will discuss how producing green hydrogen can benefit the grid when generation exceeds load and possible applications and markets for green hydrogen including injection into the natural gas system and as a fuel for dispatchable electricity generation during peak times. Technology and market status and challenges will also be identified.

decarbonization↗

Modeling of Combined Lead Fast Reactor and Concentrating Solar Power Supercritical Carbon Dioxide Cycles to Demonstrate Feasibility, Efficiency Gains, and Cost Reductions

Solar power has innate issues with weather, grid demand and time of day, which can be mitigated through use of thermal energy storage for concentrating solar power (CSP). Nuclear reactors, including lead-cooled fast reactors (LFRs), can adjust power output according to demand; but with high fixed costs and low operating costs, there may not be sufficient economic incentive to make this worthwhile. We investigate potential synergies through coupling CSP and LFR together in a single supercritical CO 2 Brayton cycle and/or using the same thermal energy storage. Combining these cycles allows for the LFR to thermally charge the salt storage in the CSP cycle during low-demand periods to be dispatched when grid demand increases. The LFR/CSP coupling into one cycle is modeled to find the preferred location of the LFR heat exchanger, CSP heat exchanger, sCO 2 -to-salt heat exchanger (C2S), turbines, and recuperators within the supercritical CO 2 Brayton cycle. Three cycle configurations have been studied: two-cycle configuration, which uses CSP and LFR heat for dedicated turbocompressors, has the highest efficiencies but with less component synergies; a combined cycle with CSP and LFR heat sources in parallel is the simplest with the lowest efficiencies; and a combined cycle with separate high-temperature recuperators for both the CSP and LFR is a compromise between efficiency and component synergies. Additionally, four thermal energy storage charging techniques are studied: the turbine positioned before C2S, requiring a high LFR outlet temperature for viability; the turbine after the C2S, reducing turbine inlet temperature and therefore power; the turbine parallel to the C2S producing moderate efficiency; and a dedicated circulator loop. While all configurations have pros and cons, use of a single cycle offers component synergies with limited efficiency penalty. Using a turbine in parallel with the C2S heat exchanger is feasible but results in a low charging efficiency, while a dedicated circulator loop offers flexibility and near-perfect heat storage efficiency but increasing cost with additional cycle components.

14 SOLAR ENERGY↗

Thermal Energy Storage Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage models developed within the HYBRID Modelica repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of concrete, latent heat, and packed-bed thermocline energy storage technologies for deployment in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to cyclically charge and discharge when exposed to time-varying boundary conditions. In addition, low-level surrogate models for some of the thermal energy storage technologies were created using Python. These lower order Python files are much cheaper to run (i.e., computationally faster) and thus operate well when incorporated within the stochastic optimization problems run for the IES program. Moreover, economic data was collected for use within the INL-developed Framework for Optimization of ResourCes and Economics (FORCE). This information is incorporated within the FORCE platform. This work has resulted in creation of systems-level models for concrete, latent heat, and thermocline thermal energy storage systems with associated control systems. Now that these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies (e.g., Storworks Power, EnergyNest) can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

25 ENERGY STORAGE↗

Solar Uncertainty Management and Mitigation for Exceptional Reliability in Grid Operations (SUMMER-GO): Project Final Report

The Solar Uncertainty Management and Mitigation for Exceptional Reliability in Grid Operation (SUMMER-GO) project was recently completed through a collaboration among the National Renewable Energy Laboratory, Maxar, the Electric Reliability Council of Texas (ERCOT), the University of Texas at Dallas, the University of California Berkeley, and the University of Colorado Boulder. The project made significant advances in probabilistic solar power forecasting, both through the development of Bayesian model averaging methods for ensemble forecasting and in bringing these and other advancements into practice with Maxar's delivery of operational forecasts to ERCOT. In addition to creating more reliable solar power forecasts, the project developed methods for their utilization in power system operations. These include the development of risk-aware unit commitment and economic dispatch algorithms and methods to reformulate probabilistic forecasts to be used in these power system operational models. Dynamic power system reserve methods were also developed, which have been shown in silico to create economic savings and reliability improvements on an ERCOT-like system as well as financial savings in the ERCOT system through more granular consideration of the uncertainty associated with solar power forecasts. Finally, a situational awareness tool to help grid operators better understand solar power forecast uncertainty in daily operations was developed and extensively vetted.

14 SOLAR ENERGY↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources: Preprint

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.

contingencies↗

Model Formulations: Integrating Distributed Energy Resources (DER) using Advanced Unit Commitment Models and DER Aggregation Methodologies

A distribution energy resource aggregator (DERA) constitutes a group of distribution energy resources with small generation capacities which meet the threshold to participate in the electricity wholesale market. This document provides the proposed DERA model formulation that will be implemented in the SCUC simulation’s architecture for the SCUC-DER project. Different economical assessment methodologies have been developed to incorporated bids for individual distributed resources, which include solar cost dispatch and cost model, BESS opportunity cost offer algorithm, and price sensitive demand response model. Detailed methods are proposed to aggregate individual cost offers to a DERA cost curve to bid in SCUC market while three methods are proposed to simulate DER actual dispatch. Based on the DERA models in this document, the SCUC-DER project will be able to assess the impacts of DERA on the distribution system’s operation and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗