Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The efficiency of convective energy transport in the sun

Mixing length theory (MLT) utilizes adiabatic expansion (as well as radiative transport) to diminish the energy content of rising convective elements. Thus in MLT, the rising elements lose their energy to the environment most efficiently and consequently transport heat with the least efficiency. On the other hand Malkus proposed that convection would maximize the efficiency of energy transport. A new stellar envelope code is developed to first examine this other extreme, wherein rising turbulent elements transport heat with the greatest possible efficiency. This other extreme model differs from MLT by providing a small reduction in the upper convection zone temperatures but greatly diminished turbulent velocities below the top few hundred kilometers. Using the findings of deep atmospheric models with the Navier-Stokes equation allows the calculation of an intermediate solar envelope model. Consideration is given to solar observations, including recent helioseismology, to examine the position of the solar envelope compared with the envelope models.

Schatten, Kenneth H.↗

Retrofitting a 1960s Split-Level, Cold-Climate Home

National programs such as Home Performance with ENERGY STAR® and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made.

1960 split level↗

Building America Case Study: Retrofitting a 1960s Split-Level, Cold-Climate Home, Westport, Connecticut; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

??National programs such as Home Performance with ENERGY STAR(R) and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made. Confirmation of successfully achieving 30% source energy savings over the pre-existing conditions was confirmed through energy modeling and comparison of the utility bills pre- and post- retrofit.

1960 split level↗

Existing Whole-House Solutions Case Study: Retrofitting a 1960s Split-Level Cold-Climate Home

National programs such as Home Performance with ENERGY STAR® and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions.

1960 split level↗

Radiation Hardened, Modulator ASIC for High Data Rate Communications

Satellite-based telecommunication services are challenged by the need to generate down-link power levels adequate to support high quality (BER approx. equals 10(exp 12)) links required for modem broadband data services. Bandwidth-efficient Nyquist signaling, using low values of excess bandwidth (alpha), can exhibit large peak-to-average-power ratio (PAPR) values. High PAPR values necessitate high-power amplifier (HPA) backoff greater than the PAPR, resulting in unacceptably low HPA efficiency. Given the high cost of on-board prime power, this inefficiency represents both an economical burden, and a constraint on the rates and quality of data services supportable from satellite platforms. Constant-envelope signals offer improved power-efficiency, but only by imposing a severe bandwidth-efficiency penalty. This paper describes a radiation- hardened modulator which can improve satellite-based broadband data services by combining the bandwidth-efficiency of low-alpha Nyquist signals with high power-efficiency (negligible HPA backoff).

McCallister, Ron↗

Planet Formation by Gas-assisted Accretion of Small Solids

We compute the accretion efficiency of small solids, with radii 1 cm ≤ R s ≤ 10 m, on planets embedded in gaseous disks. Planets have masses 3 ≤ M p ≤ 20 Earth masses (M ⊕ ) and orbit within 10 au of a solar mass star. Disk thermodynamics is modeled via 3D radiation-hydrodynamics calculations that typically resolve the planetary envelopes. Both icy and rocky solids are considered, explicitly modeling their thermodynamic evolution. The maximum efficiencies of 1 ≤ R s ≤ 100 cm particles are generally ≲10%, whereas 10 m solids tend to accrete efficiently or be segregated beyond the planet’s orbit. A simplified approach is applied to compute the accretion efficiency of small cores, with masses M p ≤ 1 M ⊕ and without envelopes, for which efficiencies are approximately proportional to $M^{2/3}_{p}$. The mass flux of solids, estimated from unperturbed drag-induced drift velocities, provides typical accretion rates dM p /dt ≲ 10 -5 M ⊕ yr -1 . In representative disk models with an initial gas-to-dust mass ratio of 70–100 and total mass of 0.05–0.06 M ⊙ , the solids’ accretion falls below 10 -6 M ⊕ yr -1 after 1–1.5 Myr. The derived accretion rates, as functions of time and planet mass, are applied to formation calculations that compute dust opacity self-consistently with the delivery of solids to the envelope. Assuming dust-to-solid coagulation times of ≈0.3 Myr and disk lifetimes of ≈3.5 Myr, heavy-element inventories in the range 3–7 M ⊕ require that ≈90–150 M ⊕ of solids cross the planet’s orbit. The formation calculations encompass a variety of outcomes, from planets a few times M ⊕ , predominantly composed of heavy elements, to giant planets. The peak luminosities during the epoch of the solids’ accretion range from ≈10 -7 to ≈10 -6 L ⊙ .

79 ASTRONOMY AND ASTROPHYSICS↗

Retrofitting a 1960s Split-Level, Cold-Climate Home

National programs such as Home Performance with ENERGY STAR® and numerous other utility air-sealing programs have made homeowners aware of the benefits of energy-efficiency retrofits. Yet these programs tend to focus only on the low-hanging fruit: they recommend air sealing the thermal envelope and ductwork where accessible, switching to efficient lighting and low-flow fixtures, and improving the efficiency of mechanical systems (though insufficient funds or lack of knowledge to implement these improvements commonly prevent the implementation of these higher cost upgrades). At the other end of the spectrum, various utilities across the country are encouraging deep energy retrofit programs. Although deep energy retrofits typically seek 50% energy savings, they are often quite costly and are most applicable to gut-rehab projects. A significant potential for lowering energy use in existing homes lies between the lowhanging fruit and deep energy retrofit approaches—retrofits that save approximately 30% in energy compared to the pre-retrofit conditions. The energy-efficiency measures need to be nonintrusive so the retrofit projects can be accomplished in occupied homes.

1960 split level↗

Capsule network-based semantic segmentation model for thermal anomaly identification on building envelopes

Thermography technology is widely used to inspect thermal anomalies in building façade systems. Computer vision-based techniques provide opportunities to autonomously detect such heat anomalies to significantly improve the efficiency of decision-making for building envelope retrofitting and maintenance. Here, in this work, we propose a novel Capsule Network-based deep learning model – CapsLab – that detects and identifies thermal anomalies by semantic segmentation. CapsLab is built based on our proposed prediction-tuning capsule (PT-Capsule) layer. Different from a traditional capsule layer, which consists of part-whole transformation and capsule-routing process, the proposed layer is composed of a prediction and tuning process, which helps decreasing the number of model parameters significantly. While the applicability of traditional Capsule Networks (CapsNets) has been limited to simpler tasks and smaller datasets due to their scalability issue, we can leverage the lightweight of the proposed PT-Capsule layer, and apply it to the semantic segmentation task. In this work, we also employ our previously presented performance metric, referred to as the Anomaly Identification Metric (AIM) (Kakillioglua et al. 2021), to evaluate the segmentation outputs. Traditional performance metrics do not accurately reflect the true performance of the segmentation models in thermal anomaly identification due to the high subjectivity in the annotation process and higher overlap ratio sensitivity of the standard metrics. AIM, on the other hand, is robust to these drawbacks. Experimental results show, both qualitatively and quantitatively, that our proposed segmentation method can effectively segment the thermal anomalies. Specifically, our model provides 9.38% and 13.53% improvements over the baseline model – DeepLabV3+ – based on traditional mIoU score and the AIM score, respectively, while requiring less model parameters and less computation at the same time. In addition, the scores that the AIM metric generates better align with the scores provided by building performance experts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources and transacts with a regulated distribution system operator (DSO) under a generalized net energy metering tariff design. To ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, we propose an incentive-aligned community pricing mechanism under which the decentralized optimization of community members' benefit implies the optimization of overall community welfare. The proposed pricing mechanism satisfies the cost-causation principle and ensures the stability of the energy community in a coalition game setting. Numerical examples provide insights into the characteristics of the proposed pricing mechanism and quantitative measures of its performance.

distributed energy resources aggregation↗

Low-cost phase change material as an energy storage medium in building envelopes: Experimental and numerical analyses

A promising approach to increasing the energy efficiency of buildings is the implementation of a phase change material (PCM) in the building envelope. Numerous studies over the last two decades have reported the energy saving potential of PCMs in building envelopes, but their wide application has been inhibited, in part, by their high cost. This article describes a novel PCM made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application. The PCM-HDPE pellets were mixed with cellulose insulation and then added to an exterior wall of a test building in a hot and humid climate, and tested over a period of several months, To demonstrate the efficacy of the PCM-enhanced cellulose insulation in reducing the building envelope heat gains and losses, side-by-side comparison was performed with another wall section filled with cellulose-only insulation. Further, numerical modeling of the test wall was performed to determine the actual impact of the PCM-HDPE pellets on wall-generated heating and cooling loads and the associated electricity consumption. The model was first validated using experimental data and then used for annual simulations using typical meteorological year (TMY3) weather data. Furthermore, this article presents the experimental data and numerical analyses showing the energy-saving potential of the new PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities: Preprint

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources downstream of a regulated distribution system operator's (DSO) net energy metering revenue meter. Due to the elevated risk of grid constraint violations and to ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, the proposed community market mechanism maximizes the community's social welfare in a decentralized fashion while every community member abides by its own operating envelopes. We show that the proposed market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. Lastly, a numerical study is implemented to showcase and compare the community's welfare under the proposed operating-envelopes-aware mechanisms to others, including the welfare of customers under the DSO's regime.

distributed energy resources aggregation↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GIANT IMPACT: AN EFFICIENT MECHANISM FOR THE DEVOLATILIZATION OF SUPER-EARTHS

Mini-Neptunes and volatile-poor super-Earths coexist on adjacent orbits in proximity to host stars such as Kepler-36 and Kepler-11. Several post-formation processes have been proposed for explaining the origin of the compositional diversity between neighboring planets: mass loss via stellar XUV irradiation, degassing of accreted material, and in situ accumulation of the disk gas. Close-in planets are also likely to experience giant impacts during the advanced stage of planet formation. This study examines the possibility of transforming volatile-rich super-Earths/mini-Neptunes into volatile-depleted super-Earths through giant impacts. We present the results of three-dimensional hydrodynamic simulations of giant impacts in the accretionary and disruptive regimes. Target planets are modeled with a three-layered structure composed of an iron core, silicate mantle, and hydrogen/helium envelope. In the disruptive case, the giant impact can remove most of the H/He atmosphere immediately and homogenize the refractory material in the planetary interior. In the accretionary case, the planet is able to retain more than half of the original gaseous envelope, while a compositional gradient suppresses efficient heat transfer as the planetary interior undergoes double-diffusive convection. After the giant impact, a hot and inflated planet cools and contracts slowly. The extended atmosphere enhances the mass loss via both a Parker wind induced by thermal pressure and hydrodynamic escape driven by the stellar XUV irradiation. As a result, the entire gaseous envelope is expected to be lost due to the combination of those processes in both cases. Based on our results, we propose that Kepler-36b may have been significantly devolatilized by giant impacts, while a substantial fraction of Kepler-36c’s atmosphere may remain intact. Furthermore, the stochastic nature of giant impacts may account for the observed large dispersion in the mass–radius relationship of close-in super-Earths and mini-Neptunes (at least to some extent)

79 ASTRONOMY AND ASTROPHYSICS↗

Single rotating stars and the formation of bipolar planetary nebula

We have computed new stellar evolution models that include the effects of rotation and magnetic torques under different hypotheses. The goal is to test whether a single star can sustain the rotational velocities needed in the envelope for magnetohydrodynamical(MHD) simulations to shape bipolar planetary nebulae (PNe) when high mass-loss rates take place. Stellar evolution models with main sequence masses of 2.5 and 5 M {sub ☉} and initial rotational velocities of 250 km s{sup –1} have been followed through the PNe formation phase. We find that stellar cores have to be spun down using magnetic torques in order to reproduce the rotation rates observed for white dwarfs. During the asymptotic giant branch phase and beyond, the magnetic braking of the core has a practically null effect on increasing the rotational velocity of the envelope since the stellar angular momentum is efficiently removed by the wind. We have also tested the best possible case scenarios in rather non-physical contexts to give enough angular momentum to the envelope. We find that we cannot get the envelope of a single star to rotate at the speeds needed for MHD simulations to form bipolar PNe. We conclude that single stellar rotators are unlikely to be the progenitors of bipolar PNe under the current MHD model paradigm.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling, Testing, and Analysis of Volvo Truck Tractor Cabins (Final Report)

Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. This project aimed to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by using efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. This project evaluated several promising candidate technologies through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. This project showed more than a 35.7% reduction in rest period idle air conditioning loads using thermal load reduction technologies. Overall heat transfer coefficient testing during cab heating, showed a 43% reduction in heating load using this technology package.

30 DIRECT ENERGY CONVERSION↗

ResStock 2024.2 Dataset [Slides]

In the ResStock 2024.2 dataset, ResStock runs are used to create "what-if" scenarios including energy efficiency measures such as heat pumps, envelope improvements, and electrification of appliances. This dataset release includes 15 measure packages across two weather years and incorporates ResStock improvements in variable speed heat pump modeling, geothermal heat pump modeling, and housing characteristic data updates from RECS 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits

Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Goode Gym Energy Renovation Project

The Ida H. Goode Gymnasium was constructed in 1964 to serve as a focal point for academics, student recreation, and health and wellness activities. This 38,000 SF building contains a gymnasium with a stage, swimming pool, eight classrooms, a weight room, six offices and auxiliary spaces for the athletic programs. The gym is located on a 4-acre greenfield, which is slated for improvement and enhancement to future athletics program at Bennett College. The available funding for this project was used to weatherize the envelope of the gymnasium, installation of a new energy-efficient mechanical system, and a retrofit of the existing lighting systems in the building’s interior. The envelope weatherization was completed without disturbing the building’s historic preservation eligibility. The existing heating system was replaced with a new high efficiency condensing system. The new heating system also includes a new Building Automation System which provides additional monitoring. Proper usage of this system will provide additional energy savings. Most of the existing interior lighting fixtures and bulbs were replaced with new LED and high efficiency T-8 bulbs and fixtures. Occupancy sensors were installed in applicable areas. The Ida Goode Gymnasium should experience high electricity and natural gas savings as well as operational/maintenance efficiency increases. The aesthetics of the building was maintained and the overall safety was improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗