Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrodes - solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Raman Spectral Observation of a "New Phase" Observed in Nickel Electrodes Cycled to Failure

A "new phase" is reported in nickel electrodes from Ni/H boilerplate cells which were cycled to failure in electrolyte of variable kOH concentration. Raman spectra clearly show the presence of this phase, and these spectra have been used to quantify the amounts present in these electrodes (in the volume sampled by the laser beam) Raman spectroscopy has been found to be capable of differentiating the various phases which can be present in nickel .This differentiation is possible because of the structural variation observed for these phases. Ten of twelve electrodes examined contain at least some of this new phase. The presence of this "new phase" correlates with cell failure, and it is proposed that the presence of this phase may play a role in early electrode failure.

Loyselle, P. L.↗

Light Weight Design Nickel-Alkaline Cells Using Fiber Electrodes

Using fiber electrode technology, currently produced by Bekaert Corporation (Bekaert), Electro Energy, Inc., (EEI) Mobile Energy Products Group (formerly, Eagle-Picher Technologies, LLC., Power Systems Department) in Colorado Springs, CO has demonstrated that it is feasible to manufacture flight weight nickel-hydrogen cells having about twice the specific energy (80 vs. 40 watt-hr/kg) as state-of-the-art nickel-hydrogen cells that are flown on geosynchronous communications satellites. Although lithium-ion battery technology has made large in-roads to replace the nickel-alkaline technology (nickel-cadmium, nickel-metal hydride), the technology offered here competes with lithium-ion weight and offers alternatives not present in the lithium-ion chemistry such as ability to undergo continuous overcharge, reversal on discharge and sustain rate capability sufficient to start automotive and aircraft engines at subzero temperatures. In development to date seven 50 ampere-hour nickel-hydrogen have been constructed, acceptance tested and briefly tested in a low earth orbit (LEO) cycle regime. The effort was jointly funded by Electro Energy, Inc. and NASA Glenn Research Center, Cleveland, OH. Five of the seven cells have been shipped to NASA GRC for further cycle testing. Two of the cells experienced failure due to internal short circuits during initial cycle testing at EEL Destructive Physical Analysis (DPA) of one of the cells has shown the failure mode to be due to inadequate hydrogen catalyst electrodes that were not capacity balanced with the higher energy density nickel oxide electrodes. In the investigators opinion, rebuild of the cells using proper electrode balance would result in cells that could sustain over 30,000 cycles at moderate depths-of-discharge in a LEO regime or endure over 20 years of geosynchronous orbit (GEO) cycling while realizing a two-fold increase in specific energy for the battery or a 1.1 kg weight savings per 50 ampere-hour cell. Additional information is included in the original extended abstract.

Pickett, David F.↗

Electric Field Effects on Fiber Alignment Using an Auxiliary Electrode during Electrospinning

This viewgraph presentation reviews auxiliary and electric field effects on fiber alignment during the process of electrospinning. The contents include: 1) Electrospinning Overview; 2) Experimental Set-up; 3) Jet Exit; 4) Auxiliary Electrode Effects; 5) Electrospinning High Speed Video; 6) Effect of Auxiliary Electrode Position; 7) Micro & Nano Fibers Produced; 8) Micro and Nano Fibrous Mats; 9) Field Effect on Fiber Distribution; 10) Modeling; 11) Calculated trajectories: 5, 10, 15 & 20cm electrode spacing; 12) Off Axis Auxiliary Electrode; 13) Field Strength Effects; and 14) Potential Applications.

Carnell, Lisa S.↗

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

Electrode support for gas arc welding torch having coaxial vision

An improved electrode mounting structure for a gas tungsten arc welding torch having a coaxial imaging system. The electrode mounting structure includes a support having a central hub and a plurality of spokes which extend from the hub generally radially with respect to the axis of the torch into supporting engagement with the interior walls of the torch. The spaces between the spokes are optical passages for transmission of light to form the image. A tubular collet holder is threadedly engaged at its upper end to the hub and extends downwardly toward the open end of the torch. The collet holder has an inwardly tapering constriction near its lower end. An electrode-retaining, tubular collet is mounted within the collet holder and has a longitudinally split and tapered end seating against the tapered constriction. A spring seats against the upper end of the collet and forces the split end against the tapered constriction to wedge the split end radially inwardly to grip the electrode within the collet.

Richardson, Richard W.↗

Electrode design for electrohydrodynamic conduction pumping

An electrohydrodynamic conduction liquid pumping system includes a vessel configured to contain a liquid or a liquid/vapor therein. This vessel can be of a elongate conduit configuration, an elongate channel configuration or a liquid enclosure configuration. At least a single pair of electrodes are disposed in a spaced apart relation to each other on the vessel and configured to be oriented in the liquid. A power supply is coupled to the electrodes and operable to generate electric fields in between the pair of electrodes, the electric forces inducing a net liquid movement relative to the vessel. Various electrode designs are embraced within the concept of this invention.

Yagoobi, Jamal Seyed↗

Spiral configuration of electrodes and dielectric material for sensing an environmental property

A reliable moisture-indicating capactive sensor is provided with wire electrodes at least one of which includes a coating of moisture-absorbing dielectric material by spirally twisting the wire electrodes about each other, thereby establishing a pair of electrodes in contact with opposite surfaces of a layer of dielectric material, and assuring consistent contact of each electrode with the dielectric material despite changes in environmental conditions.

Laue, Eric G.↗

Thin metal electrode for AMTEC

An electrode having higher power output is formed of a thin, porous film (less than 1 micrometer) applied to a beta-alumina solid electrolyte (BASE). The electrode includes an open grid, current collector such as a series of thin, parallel, grid lines applied to the thin film and a plurality of cross-members such as loop of metal wire surrounding the BASE tube. The loops are electrically connected by a bus wire. The overall impedance of the electrode considering both the contributions from the bulk BASE and the porous electrode BASE interface is low, about 0.5 OHM/cm.sup.2 and power densities of over 0.3 watt/cm.sup.2 for extended periods.

Williams, Roger M.↗

High voltage and high specific capacity dual intercalating electrode Li-ion batteries

The present invention provides high capacity and high voltage Li-ion batteries that have a carbonaceous cathode and a nonaqueous electrolyte solution comprising LiF salt and an anion receptor that binds the fluoride ion. The batteries can comprise dual intercalating electrode Li ion batteries. Methods of the present invention use a cathode and electrode pair, wherein each of the electrodes reversibly intercalate ions provided by a LiF salt to make a high voltage and high specific capacity dual intercalating electrode Li-ion battery. The present methods and systems provide high-capacity batteries particularly useful in powering devices where minimizing battery mass is important.

West, William C.↗

Mixed Conducting Electrodes for Better AMTEC Cells

Electrode materials that exhibit mixed conductivity (that is, both electronic and ionic conductivity) have been investigated in a continuing effort to improve the performance of the alkali metal thermal-to-electric converter (AMTEC). These electrode materials are intended primarily for use on the cathode side of the sodium-ion-conducting solid electrolyte of a sodium-based AMTEC cell. They may also prove useful in sodium-sulfur batteries, which are under study for use in electric vehicles. An understanding of the roles played by the two types of conduction in the cathode of a sodium-based AMTEC cell is prerequisite to understanding the advantages afforded by these materials. In a sodium-based AMTEC cell, the anode face of an anode/solid-electrolyte/cathode sandwich is exposed to Na vapor at a suitable pressure. Upon making contact with the solid electrolyte on the anode side, Na atoms oxidize to form Na+ ions and electrons. Na+ ions then travel through the electrolyte to the cathode. Na+ ions leave the electrolyte at the cathode/electrolyte interface and are reduced by electrons that have been conducted through an external electrical load from the anode to the cathode. Once the Na+ ions have been reduced to Na atoms, they travel through the cathode to vaporize into a volume where the Na vapor pressure is much lower than it is on the anode side. Thus, the cathode design is subject to competing requirements to be thin enough to allow transport of sodium to the low-pressure side, yet thick enough to afford adequate electronic conductivity. The concept underlying the development of the present mixed conducting electrode materials is the following: The constraint on the thickness of the cathode can be eased by incorporating Na+ -ionconducting material to facilitate transport of sodium through the cathode in ionic form. At the same time, by virtue of the electronically conducting material mixed with the ionically conducting material, reduction of Na+ ions to Na atoms can take place throughout the thickness of the cathode. The net effect is to reduce the diffusion and flow resistance to sodium through the electrode while reducing the electronic resistance by providing shorter conduction paths for electrons. Reduced resistance to both sodium transport and electronic conductivity results in an increase in electric power output.

Ryan, Margaret↗

Integrated Electrode Arrays for Neuro-Prosthetic Implants

Arrays of electrodes integrated with chip-scale packages and silicon-based integrated circuits have been proposed for use as medical electronic implants, including neuro-prosthetic devices that might be implanted in brains of patients who suffer from strokes, spinal-cord injuries, or amyotrophic lateral sclerosis. The electrodes of such a device would pick up signals from neurons in the cerebral cortex, and the integrated circuit would perform acquisition and preprocessing of signal data. The output of the integrated circuit could be used to generate, for example, commands for a robotic arm. Electrode arrays capable of acquiring electrical signals from neurons already exist, but heretofore, there has been no convenient means to integrate these arrays with integrated-circuit chips. Such integration is needed in order to eliminate the need for the extensive cabling now used to pass neural signals to data-acquisition and -processing equipment outside the body. The proposed integration would enable progress toward neuro-prostheses that would be less restrictive of patients mobility. An array of electrodes would comprise a set of thin wires of suitable length and composition protruding from and supported by a fine-pitch micro-ball grid array or chip-scale package (see figure). The associated integrated circuit would be mounted on the package face opposite the probe face, using the solder bumps (the balls of the ball grid array) to make the electrical connections between the probes and the input terminals of the integrated circuit. The key innovation is the insertion of probe wires of the appropriate length and material into the solder bumps through a reflow process, thereby fixing the probes in place and electrically connecting them with the integrated circuit. The probes could be tailored to any distribution of lengths and made of any suitable metal that could be drawn into fine wires. Furthermore, the wires could be coated with an insulating layer using anodization or other processes, to achieve the correct electrical impedance. The probe wires and the packaging materials must be biocompatible using such materials as lead-free solders. For protection, the chip and package can be coated with parylene.

Brandon, Erik↗

Development of Resistive Electrode Gas Electron Multiplier (RE-GEM)

We successfully produced Resistive-Electrode Gas Electron Multiplier (RE-GEM) which has resistive electrodes instead of the metal ones which are employed for the standard GEM foils. RE-GEM has a resistive electrode of 25 micron-thick and an insulator layer of 100 micron-thick. The hole structure of RE-GEM is a single conical with the wider and narrower hole diameters of 80 micron and 60 micron, respectively. A hole pitch of RE-GEM is 140 micron. We obtained the maximum gain of about 600 and the typical energy resolution of about 20% (FWHM) at an applied voltage between the resistive electrodes of 620 V, using a collimated 8 keV X-rays from a generator in a gas mixture of 70% Ar and 30% CO2 by volume at the atmospheric pressure. We measured the effective gain as a function of the electric field of the drift region and obtained the maximum gain at an drift field of 0.5 kV/cm.

detectors↗

Carbon Nanofiber Electrode Array for Neurochemical Monitoring

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Multiphysics Modeling of Electrode Dissolution under Hydrodynamic Conditions in Low Conductivity Water

Efficient plug-flow electrochemical reactors are characterized by their ability to effectively convert species with significant ionic strength and/or with the assistance of a well-behaved electrolyte. Because of the classic electroconductivity requirement, electrochemical reactors are not particularly attractive options for applications with low-conductivity conditions, especially for low-pressure feeds. However, these reactors can still find application in dedicated processes such as ultra-clean water conditioning and biological-coupled separation systems. Consequently, a multi-physics model was developed using COMSOL Multiphysics to characterize different reactor-design conditions based on the Tertiary Current Distribution which accounts for the effects of expected variations in electrolyte composition and ionic strength on the electrochemical process, as well as solution resistance and electrode kinetics. The modelling framework presented here employs single-phase laminar fluid flow, the Nernst-Planck equation, the water-based electroneutrality condition, and concentration-dependent overpotentials. This investigation particularly explores the electrolysis process of “anodic dissolution,” in which elemental species dissociate from the solid matrix of the electrode and enter the liquid phase of the electrolyte as soluble ions. The reactor configuration of interest has a rectangular parallel-electrode design and is operated galvanostatically. A series of parametric studies are carried out to inspect the response of the system when hydrodynamic, kinetic, and geometric conditions are changed. The parametric sweep resulted in variable effluent concentrations and system voltage, which reveal underlaying optimization patterns for electrode dissolution in low conductivity water.

Multiphysics↗

(abstract) Alkali Metal Diffusion Through Porous Metal Electrodes in AMTEC Cells

The mechanisms of mass transport of an alkali metal through porous metal electrodes in alkali metal thermal-to-electric converter AMTEC cells is important in optimizing these high current density devices, but also affords the opportunity to investigate a variety of simple mass transport modes at high temperatures via electrochemical techniques. We have previously reported evidence of ionic, free molecular flow, and surface transport of sodium in several types of AMTEC electrodes. Quantitative investigations of Na transport through WPt(sub 3.5) via surface or grain boundary diffusion, and K transport through porous Mo electrodes by free molecular flow, over large ranges of temperature have been performed. WPt(sub 3.5) has especially low transport impedance over the 950 to 1200K temperature range. New results are the Na through porous WPt(sub 3.5) and K through porous Mo diffusion rates and mechanisms.

alkali metal mass transport porous metal electrode↗

Plasma jet electrode has longer operating life

Water-cooled, silver-infiltrated tungsten electrode has twice the operating lifetime of the pure tungsten electrode used in plasma jet generators. This electrode reduces the erosion rate, ensures excellent heat transfer, and reduces thermal stresses.

Gracey, C. M.↗

Method of maintaining activity of hydrogen-sensing platinum electrode

Three-electrode hydrogen sensor containing a platinum electrode maintained in a highly catalytic state, operates with a minimal response time and maximal sensitivity to the hydrogen gas being sensed. Electronic control and readout circuitry reactivates the working electrode of the sensor to a state of maximal catalytic activity.

Harman, J. N., III↗