Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hemispherical Field-of-View Above-Water Surface Imager for Submarines

A document discusses solutions to the problem of submarines having to rise above water to detect airplanes in the general vicinity. Two solutions are provided, in which a sensor is located just under the water surface, and at a few to tens of meter depth under the water surface. The first option is a Fish Eye Lens (FEL) digital-camera combination, situated just under the water surface that will have near-full- hemisphere (360 azimuth and 90 elevation) field of view for detecting objects on the water surface. This sensor can provide a three-dimensional picture of the airspace both in the marine and in the land environment. The FEL is coupled to a camera and can continuously look at the entire sky above it. The camera can have an Active Pixel Sensor (APS) focal plane array that allows logic circuitry to be built directly in the sensor. The logic circuitry allows data processing to occur on the sensor head without the need for any other external electronics. In the second option, a single-photon sensitive (photon counting) detector-array is used at depth, without the need for any optics in front of it, since at this location, optical signals are scattered and arrive at a wide (tens of degrees) range of angles. Beam scattering through clouds and seawater effectively negates optical imaging at depths below a few meters under cloudy or turbulent conditions. Under those conditions, maximum collection efficiency can be achieved by using a non-imaging photon-counting detector behind narrowband filters. In either case, signals from these sensors may be fused and correlated or decorrelated with other sensor data to get an accurate picture of the object(s) above the submarine. These devices can complement traditional submarine periscopes that have a limited field of view in the elevation direction. Also, these techniques circumvent the need for exposing the entire submarine or its periscopes to the outside environment.

Hemmati, Hamid↗

The polar cap environment of outflowing O(+)

The properties of the core (0-50 eV) and 'energetic' (0-1 keV) ions, plasma waves, and auroral images obtained from Dynamics Explorer 1 (DE-1) and those of electrons, obtained from DE-2, are examined in the context of the polar cap environment. Results indicate the presence of two populations: high-speed (10-30 eV, or higher, streaming energies) polar beams and low-speed (generally less than 10-eV streaming energies) streams. The high-speed polar beams show an auroral connection (i.e., they are observed on or near the field lines threading auroral arcs), while the low-speed streams are on or near the field lines threading the dark polar cap and may be converted from the cleft ion fountain. Compared to the high-speed streams, the low-speed streams are significantly more stable with respect to energy and flux.

Horwitz, J. L.↗

Dynamical diffraction imaging (topography) with X-ray synchrotron radiation

By contrast to electron microscopy, which yields information on the location of features in small regions of materials, X-ray diffraction imaging can portray minute deviations from perfect crystalline order over larger areas. Synchrotron radiation-based X-ray optics technology uses a highly parallel incident beam to eliminate ambiguities in the interpretation of image details; scattering phenomena previously unobserved are now readily detected. Synchrotron diffraction imaging renders high-resolution, real-time, in situ observations of materials under pertinent environmental conditions possible.

Kuriyama, M.↗

NASA Tech Briefs, April 2004

Topics covered include: Analysis of SSEM Sensor Data Using BEAM; Hairlike Percutaneous Photochemical Sensors; Video Guidance Sensors Using Remotely Activated Targets; Simulating Remote Sensing Systems; EHW Approach to Temperature Compensation of Electronics; Polymorphic Electronic Circuits; Micro-Tubular Fuel Cells; Whispering-Gallery-Mode Tunable Narrow-Band-Pass Filter; PVM Wrapper; Simulation of Hyperspectral Images; Algorithm for Controlling a Centrifugal Compressor; Hybrid Inflatable Pressure Vessel; Double-Acting, Locking Carabiners; Position Sensor Integral with a Linear Actuator; Improved Electromagnetic Brake; Flow Straightener for a Rotating-Drum Liquid Separator; Sensory-Feedback Exoskeletal Arm Controller; Active Suppression of Instabilities in Engine Combustors; Fabrication of Robust, Flat, Thinned, UV-Imaging CCDs; Chemical Thinning Process for Fabricating UV-Imaging CCDs; Pseudoslit Spectrometer; Waste-Heat-Driven Cooling Using Complex Compound Sorbents; Improved Refractometer for Measuring Temperatures of Drops; Semiconductor Lasers Containing Quantum Wells in Junctions; Phytoplankton-Fluorescence-Lifetime Vertical Profiler; Hexagonal Pixels and Indexing Scheme for Binary Images; Finding Minimum-Power Broadcast Trees for Wireless Networks; and Automation of Design Engineering Processes.

Source record↗

Data storage, image tube type

Method and apparatus for the storage of digital or analog electrical signals are provided by a memory storage system employing a conventional vidicon tube. At the beginning of an operating cycle, the vidicon is conditioned to accept electrical data input by exposing its photosensitive target to a short, high intensity light flash. A first electron beam scan of the photosensitive surface then sets up a charge pattern on the photosensitive target. A second electron beam scan of the photosensitive surface by an unmodulated electron beam then develops an output signal across an output resistor by using capacitive currents. The conditioning and scanning steps are operated repetitively at high speed using conventional television camera scan, sync, and power supply circuitry to provide a low cost data storage system.

Lipoma, P. C.↗

DKDP /potassium dideuterium phosphate/ light valves

The use of potassium dideuterium phosphate (DKDP) light valves for optical data processing is discussed. The operating principles and structure of optically and electron beam addressed DKDPs are compared, and specifications for both devices given. Optically addressed DKDPs are capable of higher resolution and contrast, but both systems represent viable real time spatial light modulators adaptable to optical processing. Examples of real time data processing performed by the DKDPs include: image addition and subtraction; reduction of noise introduced by scattered light in recording media; reconstruction of computer generated and acoustic holograms; reconstruction of synthetic aperture radar data; retrieval of three-dimensional information in X-ray diagnoses; radar signal processing and display; and optical pattern recognition and correlation of images, which has applications for missile guidance systems.

Casasent, D.↗

Instruments for Imaging from Far to Near

The acronym CHAMP (signifying camera, hand lens, and microscope ) denotes any of several proposed optoelectronic instruments that would be capable of color imaging at working distances that could be varied continuously through a range from infinity down to several millimeters. As in any optical instrument, the magnification, depth of field, and spatial resolution would vary with the working distance. For example, in one CHAMP version, at a working distance of 2.5 m, the instrument would function as an electronic camera with a magnification of 1/100, whereas at a working distance of 7 mm, the instrument would function as a microscope/electronic camera with a magnification of 4.4. Moreover, as described below, when operating at or near the shortest-working-distance/highest-magnification combination, a CHAMP could be made to perform one or more spectral imaging functions. CHAMPs were originally intended to be used in robotic geological exploration of the Moon and Mars. The CHAMP concept also has potential for diverse terrestrial applications that could include remotely controlled or robotic geological exploration, prospecting, field microbiology, environmental surveying, and assembly- line inspection. A CHAMP (see figure) would include two lens cells: (1) a distal cell corresponding to the objective lens assembly of a conventional telescope or microscope and (2) a proximal cell that would contain the focusing camera lens assembly and the camera electronic image-detector chip, which would be of the active-pixel-sensor (APS) type. The distal lens cell would face outward from a housing, while the proximal lens cell would lie in a clean environment inside the housing. The proximal lens cell would contain a beam splitter that would enable simultaneous use of the imaging optics (that is, proximal and distal lens assemblies) for imaging and illumination of the field of view. The APS chip would be mounted on a focal plane on a side face of the beam splitter, while light for illuminating the field of view would enter the imaging optics via the end face of the beam splitter. The proximal lens cell would be mounted on a sled that could be translated along the optical axis for focus adjustment. The position of the CHAMP would initially be chosen at the desired working distance of the distal lens from (corresponding to an approximate desired magnification of) an object to be examined. During subsequent operation, the working distance would ordinarily remain fixed at the chosen value and the position of the proximal lens cell within the instrument would be adjusted for focus as needed.

Mungas, Greg↗

Suppression of Hydrogen Emission in an X-Class White-Light Solar Flare

We present unique NUV observations of a well-observed X-class flare from NOAA 12087 obtained at the Ondrejov Observatory. The flare shows a strong white-light continuum but no detectable emission in the higher Balmer and Lyman lines. Reuven Ramaty High-Energy Solar Spectroscopic Imager and Fermi observations indicate an extremely hard X-ray spectrum and gamma-ray emission. We use the RADYN radiative hydrodynamic code to perform two types of simulations: one where an energy of 3 x 10(exp 11) erg/sq cm/s is deposited by an electron beam with a spectral index of approx. = 3, and a second where the same energy is applied directly to the photosphere. The combination of observations and simulations allows us to conclude that the white-light emission and the suppression or complete lack of hydrogen emission lines is best explained by a model where the dominant energy deposition layer is located in the lower layers of the solar atmosphere, rather than the chromosphere.

Prochazka, Ondrej↗

Source and Propagation Characteristics of Kilometric Continuum Observed with Multiple Satellites

Kilometric continuum radiation was first identified with the GEOTAIL Plasma Wave Instrument (PWI) as the high frequency extension of escaping continuum emissions in the frequency range from 100 kHz to 800 kHz. It consists of from a few to many narrow-band emissions. It was observed mainly near the magnetic equator, and its source was expected to be inside of the plasmapause and the topside equatorial region. Recently, data from the IMAGE Radio Plasma Imager (RPI) and Extreme ultraviolet (EUV) experiments have been used to show that kilometric continuum is generated at the plasmapause, in or near the magnetic equator, within a notch region, and have confirmed the expectation. Data from the CRRES PWI have also identified other sources from the equatorial density irregularities. An example of CRRES observations reveals a possibility that kilometric continuum has been radiated as a wide beam emission. The IMAGE and GEOTAIL simultaneous observations are not like the previous observations since they show it has been observed to have a very broad emission cone. It could also be the highest frequency continuum enhancement so far observed since it is associated with a high energy electron injection event.

Hashimoto, K.↗

Effect of Crystal Defects on Minority Carrier Diffusion Length in 6H SiC Measured Using the Electron Beam Induced Current Method

We report values of minority carrier diffusion length in n-type 6H SiC measured using a planar Electron Beam Induced Current (EBIC) method. Values of hole diffusion length in defect free regions of n-type 6H SiC, with a doping concentration of 1.7El7 1/cu cm, ranged from 1.46 microns to 0.68 microns. We next introduce a novel variation of the planar method used above. This 'planar mapping' technique measured diffusion length along a linescan creating a map of diffusion length versus position. This map is then overlaid onto the EBIC image of the corresponding linescan, allowing direct visualization of the effect of defects on minority carrier diffusion length. Measurements of the above n-type 6H SiC resulted in values of hole diffusion length ranging from 1.2 micron in defect free regions to below 0.1 gm at the center of large defects. In addition, measurements on p-type 6H SiC resulted in electron diffusion lengths ranging from 1.42 micron to 0.8 micron.

Tabib-Azar, Massood↗

Electronic heterodyne recording of interference patterns

An electronic heterodyne technique is being investigated for video (i.e., television rate and format) recording of interference patterns. In the heterodyne technique electro-optic modulation is used to introduce a sinusoidal phase shift between the beams of an interferometer. For phase modulation frequencies between 0.1 and 15 MHz an image dissector camera may be used to scan the resulting temporally modulated interference pattern. Heterodyne detection of the camera output is used to selectively record the interference pattern. An advantage of such synchronous recording is that it permits recording of low-contrast fringes in high ambient light conditions. The application of this technique to the recording of holograms is discussed.

Merat, F. L.↗

Phase Holograms In PMMA

Complex, computer-generated phase holograms written in thin films of poly(methyl methacrylate) (PMMA) by process of electron-beam exposure followed by chemical development. Spatial variations of phase delay in holograms quasi-continuous, as distinquished from stepwise as in binary phase holograms made by integrated-circuit fabrication. Holograms more precise than binary holograms. Greater continuity and precision results in decreased scattering loss and increased imaging efficiency.

Maker, Paul D.↗

Acoustic holography: Problems associated with construction and reconstruction techniques

The implications of the difference between the inspecting and interrogating radiations are discussed. For real-time, distortionless, sound viewing, it is recommended that infrared radiation of wavelength comparable to the inspecting sound waves be used. The infrared images can be viewed with (IR visible) converter phosphors. The real-time display of the visible image of the acoustically-inspected object at low sound levels such as are used in medical diagnosis is evaluated. In this connection attention is drawn to the need for a phosphor screen which is such that its optical transmission at any point is directly related to the incident electron beam intensity at that point. Such a screen, coupled with an acoustical camera, can enable instantaneous sound wave reconstruction.

Singh, J. J.↗

Analysis of Iron Meteorites Using Computed Tomography and Electron-probe Microanalysis

Computed tomography (CT) imaging and electron-probe microanalysis (EPMA) have been used to study samples of the Mundrabilla and Colomera iron meteorites in order to perform structural, textural, and mineralogical analysis. Both gamma-ray (Co-60 source, essentially monochromatic 1.25MeV avg.) and x-ray (420 KeV, continuous) sources have been used, with effective resolution of approximately 1 mm and 0.25 mm, respectively. The gamma-ray source provides approx. 15 cm penetration through steel and is used for larger samples, whereas the x-ray source provides superior resolution at reduced penetration but exhibits beam hardening artifacts. Here we present a combined approach where CT and EPMA imaging and microanalysis aid in the identification of structural and compositional features in iron meteorites.

Carpenter, P. K.↗

An optical/digital processor - Hardware and applications

A real-time two-dimensional hybrid processor consisting of a coherent optical system, an optical/digital interface, and a PDP-11/15 control minicomputer is described. The input electrical-to-optical transducer is an electron-beam addressed potassium dideuterium phosphate (KD2PO4) light valve. The requirements and hardware for the output optical-to-digital interface, which is constructed from modular computer building blocks, are presented. Initial experimental results demonstrating the operation of this hybrid processor in phased-array radar data processing, synthetic-aperture image correlation, and text correlation are included. The applications chosen emphasize the role of the interface in the analysis of data from an optical processor and possible extensions to the digital feedback control of an optical processor.

Casasent, D.↗

Atmospheric Emissions Photometric Imaging (AEPI) experiment

Space plasma physics will be studied on the Atmospheric Laboratory for Applications and Science (ATLAS 1) NASA mission during the Atmospheric Emissions Photometric Imaging (AEPI) experiment. The basic scientific objective of the AEPI is the investigation of the upper atmosphere-ionosphere and the space shuttle environment. The experiment areas of the AEPI include: (1) the investigation of ionospheric transport processes by observing Mg(+) ions; (2) studies of optical properties of artificially induced electron beams; (3) measurement of electron cross sections for selected atmospheric species; (4) studies of natural airglow; and (5) studies of natural auroras. On ATLAS 1, optical emissions generated by the shuttle (shuttle ram glow) will also be investigated.

Mende, S. B.↗

Characterization of Meteorites by Focused Ion Beam Sectioning: Recent Applications to CAIs and Primitive Meteorite Matrices

Focused ion beam (FIB) sectioning has revolutionized preparation of meteorite samples for characterization by analytical transmission electron microscopy (TEM) and other techniques. Although FIB is not "non-destructive" in the purest sense, each extracted section amounts to no more than nanograms (approximately 500 cubic microns) removed intact from locations precisely controlled by SEM imaging and analysis. Physical alteration of surrounding material by ion damage, fracture or sputter contamination effects is localized to within a few micrometers around the lift-out point. This leaves adjacent material intact for coordinate geochemical analysis by SIMS, microdrill extraction/TIMS and other techniques. After lift out, FIB sections can be quantitatively analyzed by electron microprobe prior to final thinning, synchrotron x-ray techniques, and by the full range of state-of-the-art analytical field-emission scanning transmission electron microscope (FE-STEM) techniques once thinning is complete. Multiple meteorite studies supported by FIB/FE-STEM are currently underway at NASA-JSC, including coordinated analysis of refractory phase assemblages in CAIs and fine-grained matrices in carbonaceous chondrites. FIB sectioning of CAIs has uncovered epitaxial and other overgrowth relations between corundum-hibonite-spinel consistent with hibonite preceding corundum and/or spinel in non-equilibrium condensation sequences at combinations of higher gas pressures, dust-gas enrichments or significant nebular transport. For all of these cases, the ability of FIB to allow for coordination with spatially-associated isotopic data by SIMS provides immense value for constraining the formation scenarios of the particular CAI assemblage. For carbonaceous chondrites matrix material, FIB has allowed us to obtain intact continuous sections of the immediate outer surface of Murchison (CM2) after it has been experimentally ion processed to simulate solar wind space weathering. The surface amorphization and loss of OH produced by the irradiation provides important clues regarding space weathering on primitive asteroids such as the OSIRIS-Rex target 101955 Bennu.

Christoffersen, Roy↗

Energy transport and dynamics

We report findings concerning energy transport and dynamics in flares during the impulsive and gradual phases based on new ground-based and space observations (notably from Yohkoh). A preheating sometimes occurs during the impulsive phase. Ca XIX line shifts are confirmed to be good tracers of bulk plasma motions, although strong blue shifts are not as frequent as previously claimed. They often appear correlated with hard X-rays but, for some events, the concept that electron beams provide the whole energy input to the thermal component seems not to apply. Theory now yields: new diagnostics of low-energy proton and electric beams; accurate hydrodynamical modeling of pulse beam heating of the atmosphere; possible diagnostics of microflares (based on X-ray line ratio or on loop variability); and simulated images of chromospheric evaporation fronts. For the gradual phase, the continual reorganization of magnetic field lines over active regions determines where and when magnetic reconnection, the mechanism favored for energy release, will occur. Spatial and temporal fragmentation of the energy release, observed at different wavelengths, is considered to be a factor as well in energy transport and plasma dynamics.

Schmieder, Brigitte↗