At least 181 records · Page 10

X-ray Spectrometry in the Era of Aberration-Corrected Electron Optical Beam Lines

Abstract Aberration correction in the analytical transmission electron microscope is most closely associated with improvements in high-resolution imaging. In this paper, the combination of that technology with new system designs, which optimize both electron optics and x-ray detection, is shown to provide more than a tenfold increase in performance over the last 25 years.

Zaluzec, Nestor J. (ORCID:0000000248573487)↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Nanotomography for Quantitative 3D Particle Reconstruction

Particulates are ubiquitous across fuel cycle operations and carry critical information about particle formation, processing, and potential proliferation-related activities. Traditional analytical techniques, including micro-Raman spectroscopy and standard electron microscopy, are often limited in spatial resolution or dimensionality, particularly when used to examine metallic or submicron-scale features. Understanding particle morphology, phase distribution, and internal porosity is essential for constraining formation conditions, thermodynamic environments, and material transport behavior. In this report, we demonstrate the application of plasma focused ion beam nanotomography to reconstruct micron-scale particulates at nanoscale resolution. Using high-resolution backscattered electron imaging and Avizo software, we obtained 3D reconstructions that enabled quantitative analysis of particle morphology, phase composition, and internal voids. Representative examples include a Ta particle with a large central void and a composite particle with embedded tetrahedral crystalline structures. These reconstructions reveal structural and compositional details that are inaccessible through conventional 2D imaging. The results demonstrate that nanotomography provides both qualitative and quantitative insights into particle formation and behavior. Using nanotomography, porosity and phase distributions can be quantified to inform models of particle density, transport, and solidification conditions. Beyond technical insights, the workflow developed here establishes a transferable capability for analyzing heterogeneous particles and has potential applications in bulk materials studies via x-ray computed tomography or other volumetric imaging modalities. Ongoing efforts are focused on optimizing the workflow to process multiple particles simultaneously, increasing throughput and statistical robustness. Overall, this work illustrates the power of nanotomography as a tool for connecting particulate morphology to formation mechanisms, composition, and transport, thereby strengthening analytical capabilities for nuclear forensics, fuel cycle analysis, and related scientific investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scintillator detector characterization for laser-driven proton beam imaging

The spatial resolution and imaging characteristics of plastic scintillators are characterized using laser-driven proton beams. Laser-driven proton beams typically have broad energy spectra and are accompanied by relativistic electrons and high-energy photons, both potentially contributing to background noise. Different types and thicknesses of Eljen Technology scintillators are compared to determine their intrinsic point spread function. Point-projection imaging of a mesh is used to compare the imaging resolution of the scintillator to the usual imaging detector, radiochromic film, and is found to be reasonably comparable and sufficient for many experimental applications.

47 OTHER INSTRUMENTATION↗

Apparatus, method and system for imaging and utilization of SEM charged particles

A scanning electron microscope (SEM) system includes an SEM objective that emits an electron beam toward a sample, causing emission of charged particles including secondary electrons, Auger electrons, backscattered electrons, anions and cations. The SEM system includes electron optics elements that are configured to establish electric fields around the sample that accelerate charged particles toward a detector. A two-dimensional distribution of locations of incidence of the charged particles on the detector is indicative of energies of the charged particles and their emission angles from the sample. A three-dimensional spatial distribution of charged particles emitted from the sample is recovered by performing an Abel transform over the distribution on the detector. The energies and emission angles of the charged particles are then determined from the three-dimensional spatial distribution.

42 ENGINEERING↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Ultrabright and Air-Stable Photocathodes Discovered from Machine Learning and Density Functional Theory Driven Screening

The high brightness, low emittance electron beams achieved in modern X-ray free-electron lasers (XFELs) have enabled powerful X-ray imaging tools, allowing molecular systems to be imaged at picosecond time scales and sub-nanometer length scales. One of the most promising directions for increasing the brightness of XFELs is through the development of novel photocathode materials. Whereas past efforts aimed at discovering photocathode materials have typically employed trial-and-error-based iterative approaches, this work represents the first data-driven screening for high brightness photocathode materials. Through screening over 74 000 semiconducting materials, a vast photocathode dataset is generated, resulting in statistically meaningful insights into the nature of high brightness photocathode materials. This screening results in a diverse list of photocathode materials that exhibit intrinsic emittances that are up to 4x lower than currently used photocathodes. In a second effort, multiobjective screening is employed to identify the family of M 2 O (M = Na, K, Rb) that exhibits photoemission properties that are comparable to the current state-of-the-art photocathode materials, but with superior air stability. This family represents perhaps the first intrinsically bright, visible light photocathode materials that are resistant to reactions with oxygen, allowing for their transport and storage in dry air environments.

36 MATERIALS SCIENCE↗

Support for the 65th International Conference on Electron, Ion, and Photon Beam Technologies and Nanofabrication

This project aimed to enable student participation in the 65th International Conference on Electron, Ion, and Photon Beam Technologies and Nanofabrication (EIPBN). EIPBN, affectionately known as “3-Beams,” is the premier gathering of scientists and engineers who are dedicated to electron, ion and photon lithography, imaging, and analysis; nanofabrication process technologies; atomically precise fabrication; related emerging technologies; and their applications in a broad spectrum of fields. It is where top researchers from academia, government laboratories, and industries from around the world meet to present and discuss recent trends and future innovations in these technologies. The goal of the conference is to advance knowledge by enabling the exchange of information concerning advanced and emerging nanofabrication and nanomanufacturing topics and how they enable traditional and novel applications.

36 MATERIALS SCIENCE↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

Spectral and Spatial Properties of Amplified Radiation in High Gain Tapering Enhanced Stimulated Super-radiant Amplification Regime (Technical Report)

There is a wide convergence of scientific and industrial interests in understanding the physics of high efficiency conversion of relativistic electron beam power into coherent radiation. Improved understanding would open the door to ultrahigh intensity X-ray laser pulses (single shot coherent imaging and Schwingerfield physics), as well as at longer wavelength for fast throughput material processing (EUV-lithography). Modern particle accelerators can be extremely efficient (approaching 50 %) in terms of wall-plug energy use. State-of-the-art light sources on the other hand do not take advantage of all the available power and most of it is left in the beam and simply wasted on the beam dump. This proposal aimed at developing a program based on Tapered Enhanced Stimulated Superradiant Amplification to address the current limitation in electron-based coherent radiation generation exploiting the progress in high brightness beam generation and strong coupling with the electromagnetic field in a strongly tapered undulator system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Atomic resolution convergent beam electron diffraction analysis using convolutional neural networks

Two types of convolutional neural network (CNN) models, a discrete classification network and a continuous regression network, were trained to determine local sample thickness from convergent beam diffraction (CBED) patterns of SrTiO 3 collected in a scanning transmission electron microscope (STEM) at atomic column resolution. Acquisition of atomic resolution CBED patterns for this purpose requires careful balancing of CBED feature size in pixels, acquisition speed, and detector dynamic range. The training datasets were derived from multislice simulations, which must be convolved with incoherent source broadening. Sample thicknesses were also determined using quantitative high-angle annular dark-field (HAADF) STEM images acquired simultaneously. The regression CNN performed well on sample thinner than 35 nm, with 70% of the CNN results within 1 nm of HAADF thickness, and 1.0 nm overall root mean square error between the two measurements. The classification CNN was trained for a thicknesses up to 100 nm and yielded 66% of CNN results within one classification increment of 2 nm of HAADF thickness. Our approach depends on methods from computer vision including transfer learning and image augmentation.

36 MATERIALS SCIENCE↗

Fractal analysis on Ag 2 O thin film using a data-driven approach

The synthesis of fractal Ag oxide (Ag 2 O) on the surface of Ag thin film has been achieved at room temperature by using Synchrotron X-ray irradiation. We have performed an automated quantitative analysis of a batch of 1879 fractal Ag 2 O patterns in a scanning electron microscopy (SEM) image within a radius of 2000 mm outward from the center of the X-ray beam. The morphology is similar to that of the diffusion-limited cluster aggregation (DLCA) model. The fractal dimension (D) of Ag 2 O is between 1.7 and 1.5 from the center to the edge. The area distribution density of fractal Ag 2 O follows a quadratic function with radius R. It is found that the branches’ number of fractal Ag 2 O is a key factor affecting the fractal dimension. The more branches the fractal has, the greater the D is. This is the first time that Ag fractal has been investigated by combining automated data analysis methods with batch experimental data. This data-driven approach provides a new research perspective for rationally regulating materials’ fractal morphology and performance.

36 MATERIALS SCIENCE↗

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

Top-Down Fabrication of Atomic Patterns in Twisted Bilayer Graphene

Atomic-scale engineering typically involves bottom-up approaches, leveraging parameters such as temperature, partial pressures, and chemical affinity to promote spontaneous arrangement of atoms. These parameters are applied globally, resulting in atomic-scale features scattered probabilistically throughout the material. In a top-down approach, different regions of the material are exposed to different parameters, resulting in structural changes varying on the scale of the resolution. In this work, the application of global and local parameters is combined in an aberration-corrected scanning transmission electron microscope (STEM) to demonstrate atomic-scale precision patterning of atoms in twisted bilayer graphene. The focused electron beam is used to define attachment points for foreign atoms through the controlled ejection of carbon atoms from the graphene lattice. The sample environment is staged with nearby source materials such that the sample temperature can induce migration of the source atoms across the sample surface. Under these conditions, the electron-beam (top-down) enables carbon atoms in the graphene to be replaced spontaneously by diffusing adatoms (bottom-up). Using image-based feedback control, arbitrary patterns of atoms and atom clusters are attached to the twisted bilayer graphene with limited human interaction. Finally, the role of substrate temperature on adatom and vacancy diffusion is explored by first-principles simulations.

36 MATERIALS SCIENCE↗