Electronics Systems SRT

Guidance and control systems, communication, data acquisition, instrumentation, and electronics techniques for space application

Source record↗

The UV Photoinduced Ring-Closing Reaction of Cyclopentadiene Probed with Ultrafast Electron Diffraction

Conjugated cyclic organic molecules are common across many fields such as pharmaceuticals, are naturally occurring in biological systems, and are used in synthetic materials. One particular area of interest from a photochemical point of view is the formation of highly strained cyclic organics. We investigate the photoinduced reaction of cyclopentadiene, a five-membered organic ring molecule which can form strained three and four carbon rings after photoexcitation with UV light, with the gas-phase ultrafast electron diffraction instrument at the SLAC MeV-UED facility. Electron diffraction offers a direct probe sensitive to the nuclear geometry during the reaction, allowing for the determination of the distribution of products formed following photoexcitation. We observe the simultaneous formation of the highly strained ring- closed bicyclo[2.1.0]pentene and vibrationally hot cyclopentadiene within the temporal resolution of the experiment, and determine the relative yield of all reaction products. Furthermore, the experimental results are in good agreement with the predictions of trajectory simulations.

Computational Chemistry↗

Instrumentation and Measurements for Electron Emission from Charged Insulators

The electron was first discovered in 1898 by Sir John Joseph Thomson and has since been the subject of detailed study by nearly every scientific discipline. At nearly the same time Heinrich Rudolf Hertz conducted a series of experiments using cathode tubes, high potentials and ultraviolet light. When applying a large potential to a cathode he found that an arching event across the metal plates would occur. In addition, when shining an ultraviolet light on the metal he found that less potential was required to induce the spark. This result, taken together with other electrical phenomena brought about by the shining of light upon metal and was eventually termed the photoelectric effect. The work of Thomson and Hertz represent the beginning of electron emission studies and a body of ideas that pervade nearly all aspects of physics. In particular these ideas tell us a great deal about the nature of physical interactions within solids. In this thesis we will focus on the emission of electrons induced by an incident electron source over a range of energies, in which one can observe changes in emitted electron flux and energy distribution. In particular, when energetic particles impinge on a solid they can impart their energy, exciting electrons within the material. If this energy is sufficient to overcome surface energy barriers such as the work function, electron affinity or surface charge potential, electrons can escape from the material. The extent of electron emission from the material can be quantified as the ratio of incident particle flux to emitted particle flux, and is termed the electron yield.

Sim, Alec M.↗

MODIS TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments onboard the Terra and Aqua satellites have been in operation for over22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared (MWIR) bands and the Aqua PVLWIR bands affect the Level-1B (L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic crosstalk LUTs have been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

Modis TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments on board the Terra and Aqua satellites have been in operation for over 22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared(MWIR) bands and the Aqua PVLWIR bands affect the Level-1B(L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic cross talk LUT shave been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

High Energy Electron Detection with ATIC

The ATIC (Advanced Thin Ionization Calorimeter) balloon-borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons. The instrument was exposed to high-energy beams at CERN H2 bean-dine in September of 1999. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well.

Chang, J.↗

James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

thermometry↗

Output data formatter for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Output Data Formatter (ODF) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. It employs programmable logic devices to format and tag correlator data for transmission to Earth. After accepting 170 bits or correlator and error data in parallel, it appends an identification word and then serially passes the data to the Small Explorer Data System (SEDS) for transmission at a maximum rate of greater than 15 Mb/sec. Implemented with two reprogrammable field programmable gate arrays (FPGA's), each contained in a 132-pin plastic pin grid array (PGA) package, the design is cascadeable, fully testable, and low-power.

Chren, William A., Jr.↗

Walsh function generator for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Walsh Function Generator (WFG) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. Implemented in a single Xilinx XC3020PC68-50 Field Programmable Gate Array (FPGA), it generates a user-programmable set of 32 consecutive Walsh Functions for noise cancellation in the analog circuitry of the Front-End Modules (FEM's). It is implemented in a 68-pin plastic leaded chip carrier (PLCC) package, is fully testable, and can be used for noise cancellation periods as small as 2 msec.

Chren, William A., Jr.↗

The radial gradients and collisional properties of solar wind electrons

The plasma instrument on Mariner 10 carried out measurements of electron density and temperature in the interplanetary medium between heliocentric distances of 0.85 and 0.45 AU. Due to the stable coronal configuration and low solar activity during the period of observation, the radial variations of these quantities could be obtained. The power-law exponent of the core temperature was measured to be -0.3 + or - 0.04, and the halo temperature was found to be almost independent of heliocentric distance. The exponent of the power law for the density variation was 2.5 + or - 0.2 and the extrapolated value at 1 AU was consistent with measured values during the same period. Calculations of the core electron self-collision time, and the core-halo equipartition time were made as a function of radial distance. These measurements indicate a macroscale picture of a Coulomb-collisional core and a collisionless isothermal halo. Extrapolating back to the sun, core and halo temperatures become equal at a radial distance of approx. 2-15 radii.

Gilvie, K. W.↗

Television observations of artificial aurora and analyses of flight data from NASA payload 12.18 NE

An accelerator nominally capable of ejecting pulses of electrons up to 6 sec in length, current to 500 ma and energy to 20 keV was flown on a rocket at 1500 October 15, 1972. The Strypi rocket was launched from the Pacific Missile Range Facility at Kauai, Hawaii. The intent was to eject electron pulses of various characteristics upwards along the magnetic field so as to produce artificial auroras in the conjugate (Southern Hemisphere) atmosphere and possibly to produce weaker auroras in the nearby atmosphere as a consequence of backscattered electrons. The accelerator package included a gas jet actuated attitude control system controlled by gyros. Attitude sensing also was accomplished by a two-axis fluxgate magnetometer, and a large foil was deployed to collect ambient electrons to neutralize the accelerator when it ejected high-energy electrons. Scientific instrumentation contained on the flight package included retarding potential analyzers, energetic electron detectors, and detectors to sense very low frequency radio noise. Image orthicon television systems and other optical sensors were operated in the conjugate region aboard two NC-135 jet aircrafts based in Samoa. Similar devices were operated at Haleakala, Hawaii, to attempt detection of auroras caused by backscattered electrons.

Davis, T. N.↗

A study of low cost approaches to scientific experiment implementation for shuttle launched and serviced automated spacecraft

Cost reductions that can be obtained in experiment instrumentation by the use of standardized electronics and by the relaxation of instrument reliability requirements are studied. The feasibility of using standardized equipment for experiment instrumentation is assessed and a system design approach that most effectively incorporates standardized equipment is developed. The level and form of modularization that is appropriate for the standardized equipment is determined. Mission assurance aspects of instrument development are examined to determine the cost reductions that might be derived from the relaxation of reliability requirements and to formulate a systematic approach to the optimization of mission assurance cost reductions. The results of the analyses are applied to a representative model HEAO payload in order to provide a concrete example of the cost reductions that can be achieved by a standardized approach to the instrument electronics.

Source record↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

Microsystems, Space Qualified Electronics and Mobile Sensor Platforms for Harsh Environment Applications and Planetary Exploration

NASA Glenn Research Center is presently developing and applying a range of sensor and electronic technologies that can enable future planetary missions. These include space qualified instruments and electronics, high temperature sensors for Venus missions, mobile sensor platforms, and Microsystems for detection of a range of chemical species and particulates. A discussion of each technology area and its level of maturity is given. It is concluded that there is a strong need for low power devices which can be mobile and provide substantial characterization of the planetary environment where and when needed. While a given mission will require tailoring of the technology for the application, basic tools which can enable new planetary missions are being developed.

Hunter, Gary W.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1.3-octave spectrograms.

Anderson, Paul D.↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗