Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Electron Temporal Behavior in the Gun Region of the Tecnai Femto UEM

Here, we conduct systematic simulations of single-electron packet durations in the electron-gun region of a Thermo Fisher/FEI TecnaiFemto UEM. Furthermore, we conducted particle tracing simulations with the General Particle Tracer software package and using field maps generated from the precise Tecnai Femto gun architecture with the Poisson Superfish code.

36 MATERIALS SCIENCE↗

Generation of ultrahigh-brightness pre-bunched beams from a plasma cathode for X-ray free-electron lasers

The longitudinal coherence of X-ray free-electron lasers (XFELs) in the self-amplified spontaneous emission regime could be substantially improved if the high brightness electron beam could be pre-bunched on the radiated wavelength-scale. Here, we show that it is indeed possible to realize such current modulated electron beam at angstrom scale by exciting a nonlinear wake across a periodically modulated plasma-density downramp/plasma cathode. The density modulation turns on and off the injection of electrons in the wake while downramp provides a unique longitudinal mapping between the electrons’ initial injection positions and their final trapped positions inside the wake. The combined use of a downramp and periodic modulation of micrometers is shown to be able to produces a train of high peak current (17 kA) electron bunches with a modulation wavelength of 10’s of angstroms - orders of magnitude shorter than the plasma density modulation. The peak brightness of the nano-bunched beam can be $\textit{O}$(10 21 A/m 2 /rad 2 ) orders of magnitude higher than current XFEL beams. Such prebunched, high brightness electron beams hold the promise for compact and lower cost XEFLs that can produce nanometer radiation with hundreds of GW power in a 10s of centimeter long undulator.

47 OTHER INSTRUMENTATION↗

Effectiveness of Versalink 143 on Improving Shock Survival of Encapsulated Electronics

In the past, test-vehicle-mounted instrumentation modules that record sensor data during shock and vibration events have been coated with a polymer isolation layer to enhance survivability. This study uses finite element modeling to evaluate the effectiveness of the isolation material Versalink 143 on reducing stress in an instrumentation module. The modeling shows that while the isolation layer does attenuate stress due to high frequency shock and vibration, it also amplifies stress due to lower frequency shock and vibration. Thicker layers tend to attenuate high frequency stress more and amplify low frequency stress less. In addition, at higher test temperatures thermal expansion of the isolation layer can cause static stress in the module far greater than the stress due to shock, depending on how the module is constrained within the test vehicle. When designing and implementing vehicle- mounted instrumentation modules, the expected input shock spectrum, mounting constraints, and static effects of temperature must be carefully considered.

42 ENGINEERING↗

Quasilinear Analysis in the Source Region of Jovian Hectometric Emission Associated With Upward Electron Beams

Abstract Intense upward electron beams were measured by the Juno JADE instrument in the northern hemisphere, low‐latitude auroral zone source region. In this study we report on how these electron beams interact with plasma near and within the Jovian hectometric (HOM) emission (1 MHz 5 MHz) source region. Within the source region large upward loss cones are observed in the northern polar region at radial distances of 2Rj, magnetic latitude of . Intense, narrow electron beams ( 3 keV) are then observed, but within one second wave‐particle scattering is observed, filling the loss cone to energies 50 keV. These energies persist for several seconds before fading, leaving an empty loss cone again. The loss cone provides a free‐energy source for HOM emission resulting from the cyclotron maser instability. We use quasilinear analysis to examine the generation of HOM and the dynamics of wave‐particle interaction of the electron beams with HOM, and the generation via Landau interaction of whistler mode emission. The dynamic spectrum of the HOM emission generated by the loss‐cone electrons as well as that of the low‐frequency whistler‐mode waves generated by the up‐going electron beam can be constructed by quasilinear theory, which compare well with observation. The saturated state of the energetic electron velocity distribution function constructed via quasilinear theory also compare reasonably with observation.

Yoon, P. H. [Institute for Physical Science and Te↗

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Reconstructions from randomly generated longitudinal electron bunch profiles with Gaussian envelopes using the Gerchberg–Saxton algorithm

Knowledge of longitudinal electron bunch profiles is vital to optimize the performance of plasma wakefield accelerators and x-ray free electron laser linacs. Because of their importance to these novel applications, noninvasive frequency domain techniques are often employed to reconstruct longitudinal bunch profiles from coherent synchrotron, transition, or undulator radiation measurements. In this paper, we detail several common reconstruction techniques involving the Kramers–Kronig phase relationship and Gerchberg–Saxton algorithm. Additionally, through statistical analysis, we draw general conclusions about the accuracy of these reconstruction techniques and the most suitable candidate for reconstructing well-isolated longitudinal bunch profiles from spectroscopic data.

47 OTHER INSTRUMENTATION↗

Dynamic compressed sensing for real-time tomographic reconstruction

Electron tomography has achieved higher resolution and quality at reduced doses with recent advances in compressed sensing. Compressed sensing (CS) exploits the inherent sparse signal structure to efficiently reconstruct three-dimensional (3D) volumes at the nanoscale from undersampled measurements. However, the process bottlenecks 3D reconstruction with computation times that run from hours to days. Here we demonstrate a framework for dynamic compressed sensing that produces a 3D specimen structure that updates in real-time as new specimen projections are collected. Researchers can begin interpreting 3D specimens as data is collected to facilitate high-throughput and interactive analysis. Using scanning transmission electron microscopy (STEM), we show that dynamic compressed sensing accelerates the convergence speed by ~3-fold while also reducing its error by 27% for a Au/SrTiO 3 nanoparticle specimen. Before a tomography experiment is completed, the 3D tomogram has interpretable structure within ~33% of completion and fine details are visible as early as ~66%. Upon completion of an experiment, a high-fidelity 3D visualization is produced without further delay. Additionally, we report reconstruction parameters that tune data fidelity can be manipulated throughout the computation without re-running the entire process.

47 OTHER INSTRUMENTATION↗

Attosecond pulse shaping using a seeded free-electron laser

Attosecond pulses are central to the investigation of valence- and core-electron dynamics on their natural timescales. The reproducible generation and characterization of attosecond waveforms has been demonstrated so far only through the process of high-order harmonic generation. Several methods for shaping attosecond waveforms have been proposed, including the use of metallic filters, multilayer mirrors and manipulation of the driving field. However, none of these approaches allows the flexible manipulation of the temporal characteristics of the attosecond waveforms, and they suffer from the low conversion efficiency of the high-order harmonic generation process. Free-electron lasers, by contrast, deliver femtosecond, extreme-ultraviolet and X-ray pulses with energies ranging from tens of microjoules to a few millijoules. Recent experiments have shown that they can generate subfemtosecond spikes, but with temporal characteristics that change shot-to-shot. In this paper we report reproducible generation of high-energy (microjoule level) attosecond waveforms using a seeded free-electron laser. We demonstrate amplitude and phase manipulation of the harmonic components of an attosecond pulse train in combination with an approach for its temporal reconstruction. The results presented here open the way to performing attosecond time-resolved experiments with free-electron lasers.

47 OTHER INSTRUMENTATION↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Operation of Cs–Sb–O activated GaAs in a high voltage DC electron gun at high average current

Negative Electron Affinity (NEA) activated GaAs photocathodes are the most popular option for generating a high current (>1 mA) spin-polarized electron beam. Despite its popularity, a short operational lifetime is the main drawback of this material. Recent works have shown that the lifetime can be improved by using a robust Cs–Sb–O NEA layer with minimal adverse effects. In this work, we operate GaAs photocathodes with this new activation method in a high voltage environment to extract a high current. We demonstrate that improved chemical resistance of Cs–Sb–O activated GaAs photocathodes allowed them to survive a day-long transport process from a separate vacuum system using a vacuum suitcase. During beam running, we observed spectral dependence on lifetime improvement. In particular, we saw a 45% increase in the lifetime at 780 nm on average for Cs–Sb–O activated GaAs compared to Cs–O activated GaAs.

47 OTHER INSTRUMENTATION↗

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

Cryogenic probe for low-noise, high-frequency electronic measurements

The design and performance of a low-noise, modular cryogenic probe, which is applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields, is presented. The design of the probe facilitates the exchange of sample holders and sample-stage amplifiers, which, combined with its characteristic low transmission and reflection loss, make this design suitable for high precision or low sensitivity measurements. The specific example of measuring the shot noise of magnetic tunnel junctions is discussed. We highlight various design characteristics chosen specifically to expand the applicability of the probe to measurement techniques such as nuclear magnetic resonance.

47 OTHER INSTRUMENTATION↗

Cascaded hard X-ray self-seeded free-electron laser at megahertz repetition rate

High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

47 OTHER INSTRUMENTATION↗

Electron temperature relations and the direct N, O, Ne, S, and Ar abundances of 49 959 star-forming galaxies in DESI data release 2

We present the largest direct-method abundance catalogue of galaxies to date, containing measurements of 49 959 star-forming galaxies at z<0.96 from DESI (Dark Energy Spectroscopic Instrument) data release 2. By directly measuring electron temperatures across multiple ionization zones, we provide constraints on a number of electron temperature relations. Using the temperature measurements, we derive reliable abundances for N, O, Ne, S, and Ar, and measure the evolution of abundances and abundance ratios of as a function of metallicity and other galaxy properties. Our measurements include direct oxygen abundances for 49 507 galaxies, leading to the discovery of the two most metal-poor galaxies in the nearby Universe, with oxygen abundances of 12+log⁡(O/H)=6.77−0.03+0.03 dex (1.2 per cent Z⊙⁠) and 12+log⁡(O/H)=6.81−0.04+0.04 dex (1.3 per cent Z⊙⁠). We identify a rare outlier population of 24 galaxies with high-N/O ratios at low metallicity, reminiscent of galaxy abundances observed in the early Universe. We find the Ne/O ratio is constant at low metallicity but increases gradually at 12+log(O/H)>8.105±0.004 dex. We show that the S/O and Ar/O abundance ratios are strongly correlated, consistent with the expected additional Type Ia enrichment channel for S and Ar. In this work, we present an initial survey of the key properties of the sample, with this data set serving as a foundation for extensive future work on galaxy abundances at low redshift.

Scholte, D. [Edinburgh U., Inst. Astron.] (ORCID:0↗

Efficient Hot Electron Transfer from Small Au Nanoparticles

Many important chemical transformations enabled by plasmonic hot carrier photocatalysis have been reported, although their efficiencies are often too low for practical applications. Here, we examine how the efficiency of plasmon-induced hot electron transfer depends on the Au particle size in Au-tipped CdS nanorods. We show that with decreasing Au size, the plasmon width increases due to enhanced surface damping contributions. The excitation of Au nanoparticles leads to an instrument response time-limited ultrafast hot electron transfer process to CdS ($\ll$140 fs). The quantum efficiency of this process increases from ~1% to ~18% as the particle size decreases from 5.5 ± 1.1 to 1.6 ± 0.5 nm due to both enhanced hot electron generation and transfer efficiencies in small Au particles. Our finding suggests that decreasing plasmonic particle size is an effective approach for improving plasmon-induced hot carrier transfer efficiency and provides important insight for the rational improvement of plasmonic hot carrier-based devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗