Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrostatic analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Laser plasma in a magnetic field

Laser ion source (LIS) is a candidate among various heavy ion sources. A high density plasma produced by Nd:yttrium aluminum garnet laser with drift velocity realizes high current and high charge state ion beams. In order to obtain higher beam current, we made experiments using the LIS with a magnetic field by which a confinement effect can make higher beam current. We measured total current by Faraday cup and analyzed charge distribution by electrostatic ion analyzer. It is shown that the ion beam charge state is higher by a permanent magnet.

43 PARTICLE ACCELERATORS↗

Ion Energy Distributions and their Relative Abundance in Inductively Coupled Plasmas

Study of kinetics of ions and neutrals produced in high density inductively coupled plasma (ICP) discharges is of great importance for achieving a high degree of plasma assisted deposition and etching. In this paper, we present the ion energy distributions (IEDs) of various ions arriving at the grounded lower electrode. The ions were energy as well as mass analyzed by a combination of electrostatic analyzer-quadrupole mass spectrometer for pure Ar and CF4/Ar mixtures. The measurements have been made at gas pressures ranging from 30 to 100 mTorr. In addition, the IEDs were measured when the wafer-supporting electrode was also rf-powered and the effect of the self-bias was observed in the energy distributions of ions. The shapes of the IEDs are discussed an related to the sheath properties and measured electrical waveforms, as a function of pressure and applied power. Relative ion intensities were obtained by integration of each ion kinetic energy distribution function over its energy range.

Kim, J. S.↗

Compact Multichannel Charged-Particle Energy Analyzer Based on a Conical Cut Electrode

An electrostatic compact analyzer for obtaining the energy spectrum and for detecting simultaneously charged particles in a wide energy range, which is especially important for fast processes in various materials, has been proposed and designed. The energy analyzer consists of an outer conical electrode with closed end faces, which is cut into parts and fed in accordance with the law of odd numbers, and an grounded inner electrode on the surface of which charged particle beams with a wide energy range are focused. To increase the sharpness of low-energy beam focusing, an auxiliary, very small conical electrode is introduced. In spite of the small energy dispersion factor, the optimal regime of operation of the proposed analyzer with energy resolution not worse than 1% has been found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gridless retarding potential analyzer for use in very-low-energy charged particle detection

The theory of the hyperbolic retarding potential analyzer in the electrostatic mode is developed in detail and verified in the laboratory. A monoenergetic electron beam is used for the laboratory investigation. The analyzer (acronym HARP) has advantages over other conventional electrostatic analyzers; among them are less contact potential influence and high throughput because of the symmetry shape of the analyzer. The most useful application of the HARP is in detecting low-energy charged particles. A sample of low-energy particle data obtained in the earth's ionosphere is given.

Shyn, T. W.↗

Increased sensitivity of a vidicon optical multichannel analyzer with a detachable electrostatic image intensifier

A substantial gain in sensitivity is reported through the addition of a commercially available electrostatic image intensifier to a silicon-intensified target vidicon system. This comparatively low cost modification allows cooled or room temperature operation, CW or pulsed detection, and ease of removal or attachment. A 40-mm, first-generation technology image intensifier was used in a configuration in which the photocathode end was at negative high voltage and the phosphor end was at ground. Cooling the vidicon detector did not result in improved SNR; more generally, a 50-fold sensitivity increase was observed for the image intensifier/vidicon system.

Snow, J. B.↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Improvements to the APBS biomolecular solvation software suite: Improvements to the APBS Software Suite

The Adaptive Poisson-Boltzmann Solver (APBS) software was developed to solve the equations of continuum electrostatics for large biomolecular assemblages that has provided impact in the study of a broad range of chemical, biological, and biomedical applications. APBS addresses three key technology challenges for understanding solvation and electrostatics in biomedical applications: accurate and efficient models for biomolecular solvation and electrostatics, robust and scalable software for applying those theories to biomolecular systems, and mechanisms for sharing and analyzing biomolecular electrostatics data in the scientific community. To address new research applications and advancing computational capabilities, we have continually updated APBS and its suite of accompanying software since its release in 2001. In this manuscript, we discuss the models and capabilities that have recently been implemented within the APBS software package including: a Poisson-Boltzmann analytical and a semi-analytical solver, an optimized boundary element solver, a geometry-based geometric flow solvation model, a graph theory based algorithm for determining pKa values, and an improved web-based visualization tool for viewing electrostatics.

Biomedical applications↗

Understanding the selectivity of nonsteroidal anti-inflammatory drugs for cyclooxygenases using quantum crystallography and electrostatic interaction energy

Quantum crystallography methods have been employed to investigate complex formation between nonsteroidal anti-inflammatory drugs (NSAIDs) and cyclooxygenase (COX) enzymes, with particular focus on the COX-1 and COX-2 isoforms. This study analyzed the electrostatic interaction energies of selected NSAIDs (flurbiprofen, ibuprofen, meloxicam and celecoxib) with the active sites of COX-1 and COX-2, revealing significant differences in binding profiles. Flurbiprofen exhibited the strongest interactions with both COX-1 and COX-2, indicating its potent binding affinity. Celecoxib and meloxicam showed a preference for COX-2, consistent with their known selectivity for this isoform, while ibuprofen showed comparable interaction energies with both isoforms, reflecting its nonselective inhibition pattern. Key amino-acid residues, including Arg120, Arg/His513 and Tyr355, were identified as critical determinants of NSAID selectivity and binding affinity. The findings highlight the complex interplay between interaction energy and selectivity, suggesting that while electrostatic interactions play a fundamental role, additional factors such as enzyme dynamics and the hydrophobic effect also contribute to the therapeutic efficacy and safety profiles of NSAIDs. These insights provide valuable guidance for the rational design of NSAIDs with enhanced therapeutic benefits and minimized adverse effects.

60 APPLIED LIFE SCIENCES↗

Science Observations of Deep Space One

During the Deep Space One (DS1) primary mission, the spacecraft will fly by asteroid 1992 KD and possibly comet Borrelly. There are two technologies being validated on DS1 that will provide science observations of these targets, the Miniature Integrated Camera Spectrometer (MICAS) and the Plasma Experiment for Planetary Exploration (PEPE). MICAS encompasses a camera, an ultraviolet imaging spectrometer and an infrared imaging spectrometer. PEPE combines an ion and electron analyzer designed to determine the three-dimensional distribution of plasma over its field of view. MICAS includes two visible wavelength imaging channels, an ultraviolet imaging spectrometer, and an infrared imaging spectrometer all of which share a single 10-cm diameter telescope. Two types of visible wavelength detectors, both operating between about 500 and 1000 nm are used: a CCD with 13-microrad pixels and an 18-microrad-per-pixel, metal-on-silicon active pixel sensor (APS). Unlike the CCD the APS includes the timing and control electronics on the chip along with the detector. The UV spectrometer spans 80 to 185 nm with 0.64-nm spectral resolution and 316-microrad pixels. The IR spectrometer covers the range from 1200 to 2400 nm with 6.6-nm resolution and 54-microrad pixels PEPE includes a very low-power, low-mass micro-calorimeter to help understand plasma-surface interactions and a plasma analyzer to identify de individual molecules and atoms in the immediate vicinity of the spacecraft that have been eroded off the surface of asteroid 1992 KD. It employs common apertures with separate electrostatic energy analyzers. It measures electron and ion energies spanning a range of 3 eV to 30 keV, with a resolution of five percent. and measures ion mass from one to 135 atomic mass units with 5 percent resolution. It electrostatically sweeps its field of view both in elevation and azimuth. Both MICAS and PEPE represent a new direction for the evolution of science instruments for interplanetary spacecraft. These two instruments incorporate a large fraction of the capability of five instruments that had typically flown on NASA's deep space missions The Deep Space One science team acknowledges the support of Philip Varghese, David H. Lehman, Leslie Livesay, and Marc Rayman for providing invaluable assistance in making the science observations possible.

Nelson, Robert M.↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutral particle analyzer diagnostic and its first commissioning on HL-2A

A new neutral particle analyzer diagnostic has been developed for HuanLiuqi-2A (commonly referred to as HL-2A), which can provide the neutral particle flux measurement along 11 separate sightlines, simultaneously, within a wider energy range (1-70 keV). It is an electrostatic type analyzer with a removable pinhole and special-shape condenser. The energy analysis can be flexibly achieved by controlling a preset stepwise high voltage on the condenser. It is compact and its field of view covers HL-2A cross section from -33 cm to 33 cm without 'cross-talk.' The energy spectra and ion temperature profile have been obtained during its commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the analyzer design for multipoint measurements by a gold neutral beam probe on the GAMMA 10 tandem mirror

The study of the mechanisms of both transport and fluctuations is one of the main issues of fusion plasma researches. Spatial fluctuation structure measurements are important for studying of cross correlation between the two fluctuations. Gold neutral beam probe systems are used in GAMMA 10 tandem mirror plasma device. Currently, the plasma potential and its fluctuations cannot be measured at different radial positions simultaneously. This paper presents the upgrade design of the 45 deg. electrostatic energy analyzer for the simultaneous multipoint measurements of plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of a 90° electric sector energy analyzer for low energy ion beam characterization

A simple formula to calculate refocusing by locating the output slit at a specific distance away from the exit of 90° ion deflecting electric sector is given. Numerical analysis is also performed to calculate the ion beam trajectories for different values of the initial angular deviation of the beam. To validate the theory, a compact (90 mm × 5.5 mm × 32 mm) 90° sector ESA is fabricated which can fit through the inner diameter of a conflat 70 vacuum flange. Experimental results show that the dependence of resolution upon the distance between the sector exit and the Faraday cup agrees with the theory. The fabricated 90° sector electrostatic energy analyzer was then used to measure the space resolved ion energy distribution functions of an ion beam with the energy as low as 600 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the seeds of ion outflow: auroral sounding rocket observations of low-altitude ion heating and circulation

Here, we present an analysis of in situ measurements from the MICA (Magnetosphere-Ionosphere Coupling in the Alfvén Resonator) nightside auroral sounding rocket with comparisons to a multifluid ionospheric model. MICA made observations at altitudes below 325 km of the thermal ion kinetic particle distributions that are the origins of ion outflow. Late flight, in the vicinity of an auroral arc, we observe frictional processes controlling the ion temperature. Upflow of these cold ions is attributed to either the ambipolar field resulting from the heated electrons or possibly to ion-neutral collisions. We measure E → xB → convection away from the arc (poleward) and downflows of hundreds of m s -1 poleward of this arc, indicating small-scale low-altitude plasma circulation. In the early flight we observe DC electromagnetic Poynting flux and associated ELF wave activity influencing the thermal ion temperature in regions of Alfvénic aurora. We observe enhanced, anisotropic ion temperatures which we conjecture are caused by transverse heating by wave-particle interactions (WPI) even at these low altitudes. Throughout this region we observe several hundred m s -1 upflow of the bulk thermal ions colocated with WPI; however, the mirror force is negligible at these low energies; thus, the upflow is attributed to ambipolar fields (or possibly neutral upwelling drivers). Moreover, the low-altitude MICA observations serve to inform future ionospheric modeling and simulations of (a) the need to consider the effects of heating by WPI at altitudes lower than previously considered viable and (b) the occurrence of structured and localized upflows/downflows below where higher-altitude heating rocesses are expected.

47 OTHER INSTRUMENTATION↗

Element-resolved Kikuchi pattern measurements of non-centrosymmetric materials

Angle-resolved electron Rutherford backscattering (ERBS) measurements using an electrostatic electron energy analyser can provide unique access to element-resolved crystallographic information. We present Kikuchi pattern measurements of the non-centrosymmetric crystal GaP, separately resolving the contributions of electrons backscattered from Ga and P. In comparison to element-integrated measurements like in the method of electron backscatter diffraction (EBSD), the effect of the absence of a proper 4-fold rotation axis in the point group of GaP can be sensed with a much higher visibility via the element-resolved Ga to P intensity ratio. These element-resolved measurements make it possible to experimentally attribute the previously observed point-group dependent effect in element-integrated EBSD measurements to the larger contribution of electrons scattered from Ga compared to P. - Highlights: •Element specific Kikuchi patterns are presented for GaP. •Absence of a proper four-fold rotation axis is demonstrated. •Ga and P intensity variations after 90 degree rotation have opposite phase. •The asymmetry in the total intensity distribution resembles that of Ga.

36 MATERIALS SCIENCE↗