Search NASA⌕ Search

SEARCH · Search NASA

Results for “end of discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Sand Thermal Energy Storage Pilot Design (Final Report)

This report summarizes work done on developing a 10-MWhe pilot of the sand-based thermal energy storage (SandTES) technology at Alabama Power’s Plant Gaston Unit 5, an operating, supercritical coal power unit. The system will be integrated to the unit, obtaining steam to heat the sand through an air-blown fluidized-bed heat exchanger, then storing the water to be reused during discharging to produce steam that will then be vented. An electrical particle heater will also be included to provide part of the heat to the sand to provide data and learnings for commercial systems that will be fully electrically heated. Hot sand is contained in one bunker, while cold sand is housed in the other bunker, and standard solids handling equipment moves the sand around. This pilot would advance the SandTES technology to Technology Readiness Level 6 and position it for commercial readiness by 2030. This work was done in two phases: Phase I performed a conceptual study that provided Association for the Advancement of Cost Engineering (AACE) Class 5 costs and estimated performance, and then Phase II, which also involved a design update, performed a more detailed pre-front-end engineering and design study that elicited AACE Class 4 costs. Work was also done to provide estimated costs for commercial applications of the technology, assess its gaps, create its technology maturation and commercialization plans, and finally perform an Environmental Information Volume for the pilot site as a first step in the National Environmental Policy Act process.

20 FOSSIL-FUELED POWER PLANTS↗

Cost‐Effective and Scalable Approach for the Separation and Direct Cathode Recovery from End‐of‐Life Li‐Ion Batteries

Li-ion battery recycling presents a promising opportunity to decrease dependence on foreign sources of materials and harvest precious materials within the United States. Herein, a superior complete direct recycling process on individual end-of-life cells is reported where the recovered high-purity cathode active material, as well as electrolyte salt Li hexafluorophosphate (LiPF 6 ) can be reused without significant processing. This new process utilizes a series of mechanical separation steps that enable the separation of the cathode and anode active materials while they are still attached to their current collectors. Using this type of process can significantly reduce metal contamination and enable a clean cathode that can be directly recycled. The process if implemented commercially can greatly reduce the environmental burden of batteries as the greenhouse gas emissions of 8.25 kg CO 2 e kg −1 from the direct recycling process are 64% lower compared to those from virgin production of cathode material. During electrochemical testing of the recovered LiNi 0.6 Mn 0.2 Co 0.2 O 2 a discharge capacity of ≈160 mAh g −1 and good cyclability of over 250 cycles at 0.33C are achieved. This success paves a new pathway to explore and optimize existing Li-ion battery recycling procedures.

electrolyte reuse↗

Interpretation of large‐scale, long‐term electrical geophysical monitoring guided by a process simulation

Abstract Surface electrical resistivity tomography (ERT) was used at a waste site to monitor vadose zone changes in electrical properties as a proxy for contaminant flux over a span of 17 years. The BC Cribs and Trenches (BCCT) site at the Hanford site contains 20 disposal trenches and six disposal cribs. Wastes include a large inventory of technetium‐99 and large masses of nitrate and uranium‐238. ERT data were collected along 41 profiles in 2005 to characterize regions of elevated bulk electrical conductivity (BEC) associated with past liquid waste discharges. Previous analyses performed on samples from four boreholes showed a high correlation between nitrate concentration and BEC. In 2022, ERT data were re‐collected along the same profiles and six additional profiles in an area not previously surveyed. Compared to background uncontaminated areas, BEC was higher in contaminated areas at the waste sites. Given the correlation between nitrate concentration and BEC previously found at this site, ERT images show the spatial distribution and relative ionic concentration of vadose zone contaminants at BCCT. Between 2005 and 2022, ERT difference images showed a decrease in BEC surrounding most waste sites, with exceptions where there were known anthropogenic surface changes. An evaluation of recharge‐driven nitrate migration using synthetic flow and transport simulations showed that downward migration causes a decrease in BEC from the decrease in ionic strength at the trailing end of the plume where contaminants migrated downward. From this, we interpret ERT difference images as showing the predominant regions of downward ion flux.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stereoscopic high-speed microscopy to understand transient internal flow processes in high-pressure nozzles

The flow and cavitation behavior inside fuel injectors is known to affect spray development, mixing and combustion characteristics. We discuss that while diesel fuel injectors with converging and hydro-eroded holes are generally known to limit cavitation and feature higher discharge coefficients during the steady period of injection, less is known about the flow during transient periods corresponding to needle opening and closing. Multiple injection strategies involve short injections, multiplying these aspects and giving them a growing importance as part of the fuel delivery process. In this study, single-hole transparent nozzles were manufactured with the same hole inlet radius and diameter as the Engine Combustion Network Spray D nozzle, mounted to a modified version of a common-rail Spray A injector body and needle. Needle opening and closing periods were visualized with stereoscopic high-speed microscopy at injection pressures relevant to modern diesel engines. Time-resolved sac pressure was extracted via elastic deformation analysis of the transparent nozzles. Sources of cavitation were observed and tracked, enabling the identification of a gas exchange process after the end of injection with ingestion of chamber gas into the sac and orifice. We observed that the gas exchange contributed widely to disrupting the start of injection and outlet flow during the subsequent injection event.

42 ENGINEERING↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Ultrafast charging of energy-dense lithium-ion batteries for urban air mobility

Urban air mobility (UAM) demands batteries with high energy density, long cycle life, and fast rechargeability. In this paper, we demonstrate an energy-dense lithium-ion battery (LiB) with ultralong cycle life under ultrafast charging. By using the asymmetric temperature modulation (ATM) method, i.e., charging at an elevated temperature and discharging around the ambient temperature, it is experimentally shown that the 209 Wh/kg LiB is charged to 88% state of charge (SOC) in ~5 min under UAM cycling while retaining 97.7% capacity after 1,000 cycles. Moreover, an experimentally validated electrochemical-thermal (ECT) model is developed to elucidate the fast charging process and the degradation mode of UAM batteries, quantitatively capturing lithium plating during fast charging. We find that the LiBs for UAM applications are most prone to lithium plating due to their higher initial SOC required as the reserve for safety; nevertheless, the ATM method is effective in minimizing or preventing lithium plating in the high SOC range of 30-90%. In addition to slowing down capacity fade, the ATM method also raises the usable capacity by 10%, which boosts the battery energy density and ensures the battery to perform full UAM cycles even at the end of life.

25 ENERGY STORAGE↗

Giant energy storage and power density negative capacitance superlattices

Dielectric electrostatic capacitors, because of their ultrafast charge-discharge, are desirable for high-power energy storage applications. Along with ultrafast operation, on-chip integration can enable miniaturized energy storage devices for emerging autonomous microelectronics and microsystems. Moreover, state-of-the-art miniaturized electrochemical energy storage systems-microsupercapacitors and microbatteries-currently face safety, packaging, materials and microfabrication challenges preventing on-chip technological readiness, leaving an opportunity for electrostatic microcapacitors. Here, in this study, we report record-high electrostatic energy storage density (ESD) and power density, to our knowledge, in HfO 2 -ZrO 2 -based thin film microcapacitors integrated into silicon, through a three-pronged approach. First, to increase intrinsic energy storage, atomic-layer-deposited antiferroelectric HfO 2 -ZrO 2 films are engineered near a field-driven ferroelectric phase transition to exhibit amplified charge storage by the negative capacitance effect, which enhances volumetric ESD beyond the best-known back-end-of-the-line-compatible dielectrics (115 J cm -3 ). Second, to increase total energy storage, antiferroelectric superlattice engineering scales the energy storage performance beyond the conventional thickness limitations of HfO 2 -ZrO 2 -based (anti)ferroelectricity (100-nm regime). Third, to increase the storage per footprint, the superlattices are conformally integrated into three-dimensional capacitors, which boosts the areal ESD nine times and the areal power density 170 times that of the best-known electrostatic capacitors: 80 mJ cm -2 and 300 kW cm -2 , respectively. This simultaneous demonstration of ultrahigh energy density and power density overcomes the traditional capacity-speed trade-off across the electrostatic-electrochemical energy storage hierarchy. Furthermore, the integration of ultrahigh-density and ultrafast-charging thin films within a back-end-of-the-line-compatible process enables monolithic integration of on-chip microcapacitors, which can unlock substantial energy storage and power delivery performance for electronic microsystems.

25 ENERGY STORAGE↗

Design analysis of a particle-based thermal energy storage system for concentrating solar power or grid energy storage

Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.

25 ENERGY STORAGE↗

Fuel performance evaluation of two high burnup PWR core designs during normal operation, control rod withdrawal, and control rod ejection scenarios

There is interest among utilities to extend the current, 18-month operating cycle to 24 months. Economically, this extension would require greater than 5 % enrichment and peak rod average discharge burnup levels above 62 GWd/MTU. A notable challenge of increasing enrichment is the resulting additional excess reactivity encountered during the early stages of fuel life. To accommodate, burnable absorbers beyond soluble boron are introduced into the fuel system. In high burnup fuels, the possibilities of cladding lift-off and fuel melting increase due, in part, to increased rod internal pressures and limited fuel thermal conductivity, respectively. This work collaboratively employs PARCS, RELAP5-3D, and BISON to compare the fuel performance of two high burnup fuel candidates with higher than 5 % enrichment. Here, the fuel performance parameters were compared to current NRC guidance. The results demonstrate an annular fuel design with homogenously blended gadolinium as a burnable absorber operates with greater safety margins during normal operation, allowing for additional operational flexibility. During normal operation, the core design utilizing Integral Fuel Burnable Absorber pins contained fuel pins which reached plenum pressures above 15.5 MPa by the end of the first fuel cycle and fuel pins experienced cladding hoop strains above 1 %. In the Gd core design, only two observed pins experienced plenum pressures above 15.5 MPa and no pins exceeded 1 % cladding hoop strain. During the control rod withdrawal scenario, plenum pressures for pins in both designs marginally exceeded system pressure, however neither experienced excessive hoop strain. The Gd core design experienced a maximum fuel temperature of 2418 K, which is significantly higher than the Integral Fuel Burnable Absorber design at 2157 K, but still within regulatory guidance. We predicted that the fuel in both could return to service after the CRW event. We also predicted that cladding would not fail during the Control Rod Ejection in either core design. Generally, the Integral Fuel Burnable Absorber core design performed with greater safety margin with regards to temperature during normal operation and the transient events. However, the Gd core design performed with greater safety margin regarding plenum pressure and hoop strain limits during normal operation and both transient events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A liquid stratification model to predict failure in thermally damaged EBW detonators

In previous work, commercially available downward facing exploding bridgewire detonators (EBWs) were exposed to elevated temperatures. These detonators were then initiated using a firing set which discharged a high amplitude short duration electrical pulse into a thin gold bridgewire. Responses of the detonators were measured using photonic doppler velocimetry (PDV) and high-speed photography. A time delay of 4 μs between EBW initiation and first movement of an output flyer separated operable detonators from inoperable detonators or duds. Here, we propose a simple method to determine detonator operability from the calculated state of the detonator at the time the firing set is initiated. The failure criterion is based on the gap distance between the exploding bridgewire (EBW) and the adjacent initiating explosive within the detonator which is low-density pentaerythritol tetranitrate (PETN) that melts between 413-415 K (140-142 ºC). The gap forms as PETN melts and flows to the bottom of the input pellet. Melting of PETN is modeled thermodynamically as an energy sink using a normal distribution spread over a temperature range between the onset temperature of 413 K and the ending temperature of 415 K. The extent of the melt is determined from the average temperature of the PETN. The PETN liquid is assumed to occupy the interstitial gas volume in the lower part of the input pellet. The vacated volume from the relocated liquid forms the gap between the EBW and the PETN. The remaining sandwiched layer consists of solid PETN particles and gas filling interstitial volume. We predict that a threshold gap between 17-27 μm separates properly functioning detonators from duds.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Insights into the vulnerability of Antarctic glaciers from the ISMIP6 ice sheet model ensemble and associated uncertainty

Abstract. The Antarctic Ice Sheet represents the largest source of uncertainty in future sea level rise projections, with a contribution to sea level by 2100 ranging from −5 to 43 cm of sea level equivalent under high carbon emission scenarios estimated by the recent Ice Sheet Model Intercomparison for CMIP6 (ISMIP6). ISMIP6 highlighted the different behaviors of the East and West Antarctic ice sheets, as well as the possible role of increased surface mass balance in offsetting the dynamic ice loss in response to changing oceanic conditions in ice shelf cavities. However, the detailed contribution of individual glaciers, as well as the partitioning of uncertainty associated with this ensemble, have not yet been investigated. Here, we analyze the ISMIP6 results for high carbon emission scenarios, focusing on key glaciers around the Antarctic Ice Sheet, and we quantify their projected dynamic mass loss, defined here as mass loss through increased ice discharge into the ocean in response to changing oceanic conditions. We highlight glaciers contributing the most to sea level rise, as well as their vulnerability to changes in oceanic conditions. We then investigate the different sources of uncertainty and their relative role in projections, for the entire continent and for key individual glaciers. We show that, in addition to Thwaites and Pine Island glaciers in West Antarctica, Totten and Moscow University glaciers in East Antarctica present comparable future dynamic mass loss and high sensitivity to ice shelf basal melt. The overall uncertainty in additional dynamic mass loss in response to changing oceanic conditions, compared to a scenario with constant oceanic conditions, is dominated by the choice of ice sheet model, accounting for 52 % of the total uncertainty of the Antarctic dynamic mass loss in 2100. Its relative role for the most dynamic glaciers varies between 14 % for MacAyeal and Whillans ice streams and 56 % for Pine Island Glacier at the end of the century. The uncertainty associated with the choice of climate model increases over time and reaches 13 % of the uncertainty by 2100 for the Antarctic Ice Sheet but varies between 4 % for Thwaites Glacier and 53 % for Whillans Ice Stream. The uncertainty associated with the ice–climate interaction, which captures different treatments of oceanic forcings such as the choice of melt parameterization, its calibration, and simulated ice shelf geometries, accounts for 22 % of the uncertainty at the ice sheet scale but reaches 36 % and 39 % for Institute Ice Stream and Thwaites Glacier, respectively, by 2100. Overall, this study helps inform future research by highlighting the sectors of the ice sheet most vulnerable to oceanic warming over the 21st century and by quantifying the main sources of uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Enhanced plasma current spike formation due to onset of 1/1 kink-tearing reconnection during a massive gas injection process

The formation of the plasma current spike at the end of the thermal quench (TQ) phase is studied systematically, which is found to strongly correlate with the onset of the 1/1 kink-tearing reconnection only in the simulation results presented here. Here, the magnetohydrodynamic activity on the q = 1 surface plays a critical role in the spike formation and the disruption process. In particular, when the safety factor in the magnetic axis q 0 exceeds 1, the plasma major disruption transits into successive minor disruptions, and the start of the TQ phase is delayed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing a Facile Technology for Converting Domestic US Coal into High-Value Graphene

Universal Matter Ltd. was formed in July 2019 to scale-up and commercialize a breakthrough process, Flash Joule Heating (FJH), to transform different coal grades, into high-quality graphene. This graphene is made using a high-voltage electric discharge that brings the carbon source to temperatures higher than 3,000 K in less than 10 milliseconds. The short burst of electricity breaks all chemical bonds in the feedstock and reorders the carbon atoms into exceptionally thin layers of a special type of graphene, at an estimated $100 per ton in electricity cost. This process is capable of producing 1-5 layer-thick high-quality graphene (with defects of <0.05% and purity of >99%) in a green, practical, and cost-effective process. The graphene produced in the FJH process is a very special kind of graphene called “turbostratic graphene” (TG). TG offers superior physical properties compared to other graphene structures on a similar weight basis. Unlike graphene made from graphite using traditional techniques, the graphene layers in TG stack in an irregular pattern that allows the graphene powder to be exfoliated more easily and blend more evenly within other materials. The TG produced using our FJH technology is the most economical graphene product that opens up significant large volume markets for end-use applications; it would allow the use of TG made from coal for commercial applications in several market segments including energy storage, sensors, hyper-lubricants, reinforced plastics, and building materials such as concrete.

01 COAL, LIGNITE, AND PEAT↗

Degradation and Modeling of Large-Format Commercial Lithium-Ion Cells as a Function of Chemistry, Design, and Aging Conditions

Demand for large-format (>10 Ah) lithium-ion batteries has increased substantially in recent years, due to the growth of both electric vehicle and stationary energy storage markets. The economics of these applications is sensitive to the lifetime of the batteries, and end-of-life can either be due to energy or power limitations. Despite this, there is little information from cell manufacturers on the sensitivity of cell degradation to environmental conditions or battery use. This work reports accelerated aging test data from four commercial large-format lithium-ion batteries from three manufacturers, with varying design (thickness, casings, ...), chemistry (lithium-iron-phosphate (LFP) or lithium-nickel-manganese-cobalt-oxide positive electrodes (NMC), with graphite (Gr) negative electrodes), and capacity (50 to 250 Amp hours). The tested LFP|Gr cell is found to be relatively insensitive to cycling conditions like temperature or voltage window, while NMC|Gr cells have varying sensitivity. Degradation trends are further investigated by training predictive models: simple polynomial trend lines, a semi-empirical reduced-order model, and an empirical reduced-order model identified using machine-learning based on symbolic regression. Calendar and cycle life are simulated over a variety of conditions to directly compare the various batteries. Cell size and thickness are found to substantially impact sensitivity to temperature during cycle aging, while electrode chemistry impacts depth-of-discharge sensitivity. Real-world battery lifetime is evaluated by simulating residential energy storage and commercial frequency containment reserve systems in several U.S. climate regions. Predicted lifetime across cell types varies from 7 years to 20+ years, though all cells are predicted to have at least 10 year life in certain conditions.

battery lifetime↗

Plutonium mobilization from contaminated estuarine sediments, Esk Estuary (UK)

Since 1952, liquid radioactive effluent containing 238-242 Pu, 241 Am, 237 Np, 137 Cs, and 99 Tc has been released with authorization from the Sellafield nuclear complex (UK) into the Irish Sea. This represents the largest source of plutonium (Pu) discharged in all western Europe, with 276 kg having been released. In the Eastern Irish Sea, the majority of the transuranic activity has settled into an area of sediments (Mudpatch) located off the Cumbrian coast. Radionuclides from the Mudpatch have been re-dispersed via particulate transport in fine-grained estuarine and intertidal sediments to the North-East Irish Sea, including the intertidal saltmarsh located at the mouth of the Esk Estuary. Saltmarshes are highly dynamic systems which are vulnerable to external agents (sea level change, erosion, sediment supply, and freshwater inputs), and their stability remains uncertain under current sea level rise projections and possible increases in storm activity. In this work, we examined factors affecting Pu mobility in contaminated sediments collected from the Esk Estuary by conducting leaching experiments under both anoxic and oxic conditions. Here, leaching experiments were conducted over a 9-month period and were periodically sampled to determine solution phase Pu via multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS), and to measure redox indicators (Eh, pH and extractable Fe(II)). Microbial community composition was also characterized in the sediments, and at the beginning and end of the anoxic/oxic experiments. Results show that: 1) Pu leaching is about three times greater in solutions leached under anoxic conditions compared to oxic conditions, 2) the sediment slurry microbial communities shift as conditions change from anoxic to oxic, 3) Pu leaching is enhanced in the shallow sediments (0–10 cm depth), and 4) the magnitude of Pu leached from sediments is not correlated with total Pu, indicating that the biogeochemistry of sediment-associated Pu is spatially heterogeneous. These findings provide constraints on the stability of redox sensitive Pu in biogeochemically dynamic/transient environments on a timescale of months and suggests that anoxic conditions can enhance Pu mobility in estuarine systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Knowledge-informed deep learning for hydrological model calibration: an application to Coal Creek Watershed in Colorado

Abstract. Deep learning (DL)-assisted inverse mapping has shown promise in hydrological model calibration by directly estimating parameters from observations. However, the increasing computational demand for running the state-of-the-art hydrological model limits sufficient ensemble runs for its calibration. In this work, we present a novel knowledge-informed deep learning method that can efficiently conduct the calibration using a few hundred realizations. The method involves two steps. First, we determine decisive model parameters from a complete parameter set based on the mutual information (MI) between model responses and each parameter computed by a limited number of realizations (∼50). Second, we perform more ensemble runs (e.g., several hundred) to generate the training sets for the inverse mapping, which selects informative model responses for estimating each parameter using MI-based parameter sensitivity. We applied this new DL-based method to calibrate a process-based integrated hydrological model, the Advanced Terrestrial Simulator (ATS), at Coal Creek Watershed, CO. The calibration is performed against observed stream discharge (Q) and remotely sensed evapotranspiration (ET) from the water year 2017 to 2019. Preliminary MI analysis on 50 realizations resulted in a down-selection of 7 out of 14 ATS model parameters. Then, we performed a complete MI analysis on 396 realizations and constructed the inverse mapping from informative responses to each of the selected parameters using a deep neural network. Compared with calibration using observations covering all time steps, the new inverse mapping improves parameter estimations, thus enhancing the performance of ATS forward model runs. The Nash–Sutcliffe efficiency (NSE) of streamflow predictions increases from 0.53 to 0.8 when calibrating against Q alone. Using ET observations, on the other hand, does not show much improvement on the performance of ATS modeling mainly due to both the uncertainty of the remotely sensed product and the insufficient coverage of the model ET ensemble in capturing the observation. By using observed Q only, we further performed a multiyear analysis and show that Q is best simulated (NSE > 0.8) by including in the calibration the dry-year flow dynamics that show more sensitivity to subsurface characteristics than the other wet years. Moreover, when continuing the forward runs till the end of 2021, the calibrated models show similar simulation performances during this evaluation period as the calibration period, demonstrating the ability of the estimated parameters in capturing climate sensitivity. Our success highlights the importance of leveraging data-driven knowledge in DL-assisted hydrological model calibration.

54 ENVIRONMENTAL SCIENCES↗

A Comparative Analysis of Lithium-Ion Battery Chemistries for Cold-Climate Maritime Applications

Energy storage, primarily in the form of electrochemical batteries, is critical for enabling integration of marine energy (e.g., power from waves and currents) with end-use applications at sea due to the periodicity of the resources and requirement of consistent, smooth power delivery. Powering high-latitude coastal or ocean-based observing systems has been identified as a high value-proposition use case, exemplifying the concept of Powering the Blue Economy. An existing power system implementation for such a platform uses solar panels coupled to rechargeable lithium-ion batteries, augmented by a non-rechargeable backup bank used to power heaters in winter months. As wave energy is a potential resource for powering this and similar use cases and is strongest when solar power is most limited, it was hypothesized that integration of wave power would alleviate some of the challenges in cold climates related to energy storage. In this work, we investigate the use case scenario in simulation and perform a comparative test of commercially-available lithium-ion battery chemistry formulations to determine the most appropriate choice for the application. The experiment compared the most commonly-used lithium-based battery types (NCM, NCA, and LFP) in laboratory conditions emulating a battery enclosure thermally coupled to freezing seawater using an industrial battery performance tester in PNNL's arctic simulation lab. Battery strings were repeatedly cycled (i.e., charged, discharged, rested) and their usable capacity was measured. Both NCM and NCA strings exhibited degradation upon cycling, while the LFP string maintained stable operation through over 700 complete cycles. Though lower in baseline capacity, LFP are recommended for this and similar low-temperature applications with access to high levels of bulk charging current (e.g., from high-energy wave events) and their use may reduce the cost and complexity of battery conditioning and protection apparatus.

16 TIDAL AND WAVE POWER↗