Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy efficiency measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

Impact of ceiling fan and room air cleaner on air mixing and fate of particulate matter in a multiroom residence

We are exposed to airborne particles of health concern in residences, and Room Air Cleaners (RACs) can remove these particles. However, they are often limited to treating local air in the room or near vicinity of the device. RAC performance in multi-room residences may be improved by ceiling fan whole-house air mixing with a minor increase in energy use. Here, this study analyzed air quality and energy efficiency from experimental measurements using combinations of ceiling fan and RAC operation. We measured removal rates of tracer gas and particles from ultrafine to 5 µm after their release in the kitchen area of a multiroom test house. Results show that the air mixing by ceiling fans increased ultrafine and > 1 µm particle removal over the baseline – with no ceiling fans and no RAC – suggesting increased deposition onto the ceiling fan blades and house surfaces. Also, ceiling fan mixing increased particle removal in all size bins over the RAC performance with no ceiling fans. The removal rate with ceiling fans and the RAC was greater than the sum of the rates from each operating alone, indicating that synergistic interactions between the ceiling fans and the RAC increased the RAC filtration rate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Controlled Environment Agriculture SiteScout (CEA SiteScout) v1.0

This is a geospatial online decision support tool designed to help identify locations where controlled environment agriculture (CEA) can be cited to take advantage of energy and water resources. It also quantifies the benefits of selected energy and water efficiency measures.

Stokes-Draut, Jennifer [Lawrence Berkeley National↗

Remote sunfall monitor: A concept

Monitor is proposed as spectral monitor system designed to record digital data simultaneously from two types of sensors, mounted on both stationary assembly and tracking assembly. Both direct and total values of solar radiation are recorded. System may measure solar energy collector efficiencies for three main conversion technologies.

Lollar, R. B.↗

High-efficiency silicon solar cells

Silicon solar cells are described which operate at energy conversion efficiencies independently measured at 18.7 percent under standard terrestrial test conditions (AM1.5, 100 mW/sq cm, 28 C). These are apparently the most efficient silicon cells fabricated to date. The high-efficiency results from a combination of high open-circuit voltage due to the careful attention paid to the passivation of the top surface of the cell, high fill factor due to the high open-circuit voltage and low parasitic resistance losses, and high short-circuit current density due to the use of shallow diffusions, a low grid coverage, and an optimized double layer antireflection coating.

Green, M. A.↗

2024 Buildings Technology Baseline: Dataset Documentation

The Buildings Technology Baseline is a curated and regularly updated dataset of current and projected performance, retail, and installed price data for all major building energy technologies needed to enable cost/benefit analyses. Building technology analyses require an up-to-date understanding of installation costs and cost-effectiveness of key building energy efficiency technologies. The dataset was assembled by Guidehouse during fiscal year 2024. Data was gathered from the 2024 National Residential Efficiency Measures Database (NREMDB), the 2023 Energy Information Administration Updated Buildings Sector Appliance and Equipment Costs and Efficiencies ("EIA Building Data Report"), DOE Lighting Market Model, the 2023 RSMeans database, and the 2020 Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics ("GEB Data Report"), Lawrence Berkeley National Laboratory, various literature, as well as new data from online retailers, stakeholder interviews, and contractor databases in 2023 and 2024. The dataset has been reviewed by subject matter experts at NREL and DOE. The 2024 dataset release is intended to be a starting point for interested users to provide feedback. This database is not intended to provide specific cost estimates for a specific project. The cost estimates do not include any rebates or tax incentives that may be available for the measures. Rather, it is meant to help determine which measures may be more cost-effective. The National Renewable Energy Laboratory (NREL) makes every effort to ensure accuracy of the data; however, NREL does not assume any legal liability or responsibility for the accuracy or completeness of the information.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latched detection of zeptojoule spin echoes with a kinetic inductance parametric oscillator

When strongly pumped at twice their resonant frequency, nonlinear resonators develop a high-amplitude intracavity field, a phenomenon known as parametric self-oscillations. The boundary over which this instability occurs can be extremely sharp and thereby presents an opportunity for realizing a detector. Here, we operate such a device based on a superconducting microwave resonator whose nonlinearity is engineered from kinetic inductance. The device indicates the absorption of low-power microwave wavepackets by transitioning to a self-oscillating state. Using calibrated pulses, we measure the detection efficiency to zeptojoule energy wavepackets. We then apply it to measurements of electron spin resonance, using an ensemble of 209 Bi donors in silicon that are inductively coupled to the resonator. We achieve a latched readout of the spin signal with an amplitude that is five hundred times greater than the underlying spin echoes.

42 ENGINEERING↗

Efficiency of Photosynthesis in a Chl d-Utilizing Cyanobacterium is Comparable to or Higher than that in Chl a-Utilizing Oxygenic Species

The cyanobacterium Acaryochloris marina uses chlorophyll d to carry out oxygenic photosynthesis in environments depleted in visible and enhanced in lower-energy, far-red light. However, the extent to which low photon energies limit the efficiency of oxygenic photochemistry in A. marina is not known. Here, we report the first direct measurements of the energy-storage efficiency of the photosynthetic light reactions in A. marina whole cells,and find it is comparable to or higher than that in typical, chlorophyll a-utilizing oxygenic species. This finding indicates that oxygenic photosynthesis is not fundamentally limited at the photon energies employed by A. marina, and therefore is potentially viable in even longer-wavelength light environments.

Mielke, S. P.↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The DREAM approach to demand-side emissions reductions in Indonesia, 2020–2060

Indonesia’s current energy system modeling is heavily focused on the supply side, but emissions reductions in the demand sector have a significant impact on advancing Indonesia’s ambitious emissions reductions goals. To address the gap, we develop a new modeling tool DREAM Indonesia based on a bottom-up, technology-rich demand side framework and formulate projections of demand-side emissions reductions in Indonesia in 2020–2060. We find that demand-side energy efficiency and electrification can halve the growth rate of final energy demand to 1.4% annually over 2020–2060 and reverse the growing trend of emissions. The feasibility of full electrification by 2060, coupled with rapid adoption of existing technologies, positions the building sector as a model for achievable decarbonization and a cornerstone of Indonesia’s emissions reductions ambitions. In the industrial sector, extensive emissions reductions of 87% by 2060 (compared to business-as-usual) are achievable through energy efficiency improvements, alongside enhanced material efficiency measures including optimized material usage, low-carbon substitutions, innovative technologies, and increased circularity. In the transportation sector, balancing final energy demand by incorporating energy efficiency improvements across all transport modes, along with electrification particularly in road transportation, could decrease the emissions by up to 82% in 2060 compared to business-as-usual. This study provides insights and modeling approaches for rapidly growing Asian economies as well as other developing countries facing combined development and decarbonization challenges.

DREAM Indonesia↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

Advanced Manufactured Home Case Study: A Collaboration for High-Efficiency, Affordable Housing

The introduction of Zero Energy Ready Home Manufactured Homes (ZERH MH) qualification for manufactured homes has generated significant attention and interest in the industry to employ advanced manufacturing techniques. VEIC engaged with Titan Homes to create an advanced manufactured home design that employs ZERH standards, other client-driven above-code standards, and manufacturing processes improvements. This case study identifies specific energy-efficient and quality improvement measures that were implemented to achieve certification and take advantage of incentives for home manufacturers.

14 SOLAR ENERGY↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of the Low-Energy Electron Inelastic Mean Free Path in Monolayer Graphene

Measuring the electron-transport properties of substrate-supported nanomaterials with the traditional two-point comparison method is difficult at electron energies below 50 eV, where core-level signals are too feeble to be detected against the strong secondary-electron background. Herein, a data-driven spectral analysis technique is used to study the low-energy electron-transport properties of substrate-supported target nanomaterials, while eliminating the influence of the substrate signal. Applying this technique, the electron-transport properties of the effective attenuation length and the inelastic mean free path (IMFP) can be determined with extremely high efficiency over the entire measured energy range of 6–600 eV. Further, these results show excellent agreement with other experimental and theoretical results. In this work, significant differences are observed between monolayer graphene and the bulk graphite IMFP, which illustrates the importance of the nanometer effect in the electron-transport properties of the material. Furthermore, this technique is readily applicable to any ultrathin material that can be transferred onto a polycrystalline gold substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗