Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy management system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

User-Focused Tools to Enhance IT/OT Cyber Resilience within the Power Grid

The power grid is undergoing several changes that are increasing its complexity as nexuses between electric-gas, transmission-distribution, and energy-communications continue to become increasingly critical. This system is heavily dependent on communication infrastructure and controls, and it relies on humans in operational technology (OT) and information technology (IT) roles to manage the increasing breadth, depth, and speed of data. Many technical challenges have presented themselves and will need to be addressed to provide reliable grid operations. With increased reliance on distributed controls and communication infrastructure, cybersecurity becomes an inherent requirement. When considering current cyber-physical security solutions for the power grid, one can notice a clear divide between information technology and operation technology networks. However, in real-life applications, these networks are interdependent. This work presents results of interviews with key utility cybersecurity personnel, analyzes the results, and makes recommendations towards solution of existing technical and operational challenges realized. Existing workflows are presented, wireframe interviews are discussed, and tool requirements are described. The existence of easy-to-implement solutions, based on existing energy management systems, highlight the potential for real-life applications.

cybersecurity, resilience, user-centered design, p↗

Prediction of Power Measurements Using Adaptive Filters

With the advent of smart grid concept, Internet of Things (IoT) and the deployment of smart meters, the cyberattack threats on power networks have increased due to the use of communication systems that can be accessed by adversaries. Attackers will have the ability to manipulate the outcomes of smart meters which in turn influence the core application of Energy Management System 9EMS): State Estimation (SE). Bad data analytic tools may fail to detect some attacks into measurements. Meanwhile, Machine Learning (ML) solutions have been proposed for detecting False Data Injection (FDI) attacks. However, there is a lack of ML time-series solutions presented in the state-of-the-art that is yet to be complex. In signal processing, time-series solutions do not only consider the signal, but also the statistics of the signal over time. Therefore, in this paper, a machine learning for time-series solutions is presented as an application to model the measurements of the power grid that are used in SE. The presented model takes into account adaptive linear and non-linear filters: Finite Impulse Response (FIR), and Infinite Impulse Response (IIR). The presented models are implemented and performed on the IEEE-118 bus system. The results indicate the advantage of applying those filters over the state-of-the-art machine learning solutions.

Hamad, Khaled↗

Avista’s Shared Energy Economy Model Pilot: A Techno-economic Assessment

As part of the second round of the Washington Clean Energy Fund, Avista Corp received a $3.5 million matching grant in support of a shared energy economy project to test the integration of energy assets–from rooftop solar and battery storage to building energy management systems–that can be shared and used for multiple purposes. The goal of this project is to demonstrate how both the customer and the utility can benefit from this shared energy economy model and demonstrate that the electric grid can become more reliable, efficient, resilient, and flexible. Pacific Northwest National Laboratory was engaged by the U.S. Department of Energy and the Washington State Department of Commerce to work with Avista in assessing the benefits of the shared energy economy model. This report documents the techno-economic assessment of the shared energy economy model, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, and case studies and analysis results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Saving Analysis Using Energy Intensity Usage and Specific Energy Consumption Methods

This study presents the energy saving analysis reached through employing the energy intensity usage and specific energy consumption method. The energy analyses conducted in this study are used for implementing a new technology. However, they are additionally used to evaluate the latest concepts, techniques, processes, and uses for technologies, which are aimed at improvement of energy savings. This study shows the correlation between energy consumption, potential energy savings, and the impact of the energy assessment in different industrial sectors. The correlation is found by using two indicators: (1) the energy intensity usage (EIU) and (2) the specific energy consumption (SEC). The data analysis in this study considers the assessments for 67 industries from 2015 to 2019 and classifies those assessments using the Standard Industrial Classification (SIC) code. The results show that energy savings and energy consumption are linearly related. Also, the energy assessment improves energy performance in a more significant way for smaller companies than for larger industries. Furthermore, these results can be extrapolated by identifying the potential benefits of the energy management system (EMS) implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

This project demonstrated how incorporating a diverse generation and storage portfolio allows an urban district energy system to improve its efficiency by at least 50% and increase its backup power by at least 40% with a return on investment of at least ten years. The improvement was evaluated against the baseline operations for two urban district energy systems (DESs): a synthetic DES and a George Washington University DES. The DES techno-economic framework we developed yields reliability, resilience, and vulnerability indices for urban DESs (including generation and storage) with designation of which technologies improve the security and resiliency metrics by at least 20% compared to the status quo. The indices are benchmarked against baseline scenarios, and cost projections (capital cost and return on investment) to achieve the 20% improvement are reported. The energy management system we developed to conduct these analyses was incorporated into a user-friendly interface that can be used for decision-making by a user with no technical or programming background.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Freight Productivity of a Heavy-Duty, Battery Electric Truck by Intelligent Energy Management

This project aimed to enhance the range and reduce the operating costs of battery electric Class 8 trucks traveling over 250 miles daily. This was achieved through the development and implementation of an intelligent-Energy Management System (i-EMS) that leverages vehicle and operations data, physics-aware machine learning algorithms, and vehicle-to-cloud (V2C) connectivity. The project hypothesized that advanced machine learning algorithms and real-time data analytics could significantly improve the energy efficiency and range of these trucks. Key objectives included developing a physics-aware machine learning algorithm, implementing an i-EMS with V2C connectivity and physics-aware spatial data analytics (PSDA), and validating the system’s effectiveness with fleet partners HEB Companies and Murphy Logistics. Extensive data collection from vehicle operations, including vehicle characteristics, road conditions, and payload, was conducted. A machine learning algorithm was developed to predict energy consumption and enable proactive decision-making. The i-EMS was implemented on two Volvo VNR BEVs, with operators receiving charging and routing recommendations. Charging stations were installed at depot locations in Texas and Minnesota, with an additional on-route charger in Minnesota. Significant findings included a 14% range improvement for Murphy Logistics on a highway-driving eco-route and a 22% range improvement for HEB Companies on a city-driving eco-route. The i-EMS utilized rule-based methods and physics-based algorithms to predict and reduce energy consumption, with real-time monitoring and analysis through V2C connectivity enabling proactive decision-making. The project demonstrated the feasibility and economic viability of battery electric Class 8 trucks for long-haul operations, showcasing the potential of physics-aware machine learning in optimizing energy management. The successful implementation of the i-EMS in real-world scenarios validates its practical application and effectiveness, paving the way for the widespread adoption of battery electric vehicles in the freight transportation industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Network-Aware Distributed Energy Resource Aggregation Framework for Flexible, Cost-Optimal, and Resilient Operation

To efficiently use the ubiquitous behind-the-meter distributed energy resources (DERs) in distribution systems for providing grid services, this paper presents a hierarchical control framework for DER optimal aggregation and control. We first develop a convex optimization model to evaluate the DER flexibility, and then use a convex model-predictive-control based approach to dispatch those DERs. The hierarchical control framework consists of a utility controller, community aggregators and multiple home energy management systems. The flexibility of the DERs is evaluated by each controller in the hierarchy such that the resultant flexibility is feasible given its operational domain. Based on the determined flexibility, the hierarchical controllers then compute optimal setpoints for the DERs to help the distribution system regulate node voltages and provide other distribution grid services. Numerical simulations performed on a model of a real distribution feeder in Colorado, using actual DER data in a residential community demonstrate that the proposed approach can effectively alleviate voltage issues and support resilient operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection in Power System State Estimation: Review and New Directions

Foundational and state-of-the-art anomaly-detection methods through power system state estimation are reviewed. Traditional components for bad data detection, such as chi-square testing, residual-based methods, and hypothesis testing, are discussed to explain the motivations for recent anomaly-detection methods given the increasing complexity of power grids, energy management systems, and cyber-threats. In particular, state estimation anomaly detection based on data-driven quickest-change detection and artificial intelligence are discussed, and directions for research are suggested with particular emphasis on considerations of the future smart grid.

42 ENGINEERING↗

Industrial Assessment Center for Energy Efficiency, Smart Manufacturing and Cyber Security of Illinois and Northwestern Indiana Small and Medium Sized Manufacturing Companies and Water Facilities (Final Technical Report)

The University of Illinois Chicago (UIC) established and implemented a U.S. Department of Energy (DOE) sponsored Industrial Assessment Center (IAC) from September 1, 2016 through December 31, 2021. The established UIC IAC focused on providing 1) technical assistance to small and medium-sized enterprises (SMEs) and water and wastewater facilities in Illinois and northwestern Indiana and 2) education and training university students developing the future energy workforce. The technical assessments incorporated energy efficiency, increasing productivity via smart manufacturing, energy management systems, enhancing on-site cyber security practices, and the promotion of DOE best practices and tools. The educational training enabled UIC faculty and staff to provide classroom education, exposure to industry research, multiple targeted training sessions, real world experience with industry professionals, and live training to implement professional grade audits and recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Digital data provenance for the power grid based on a Keyless Infrastructure Security Solution

In this work a data provenance system for grid-oriented applications is presented. The proposed Keyless Infrastructure Security Solution (KISS) provides mechanisms to store and maintain digital data fingerprints that can later be used to validate and assert data provenance using a time-based, hash tree mechanism. The developed solution has been designed to satisfy the stringent requirements of the modern power grid including execution time and storage necessities. Its applicability has been tested using a lab-scale, proof-of-concept deployment that secures an energy management system against the attack sequence observed on the 2016 Ukrainian power grid cyberattack. The results demonstrate a strong potential for enabling data provenance in a wide array of applications, including speed-sensitive applications such as those found in control room environments.

Sebastian Cardenas, David J.↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid

Legacy energy management systems for distribution system or microgrids are typically driven by economics. During extreme events, resiliency can be defined as ability of the system to keep supplying critical loads. Resilient operation during extreme events (e.g. avalanche in Alaska) may require decision variables to be different and conflicting with economic operation. Operational objectives are driven by a complex consideration of the economic, reliable and resilient operation of the system: economic and reliable in normal operating state and resilient during extreme events. Challenge is to move between economic and resilient operation in optimal manner and setting up problem formulation and constraints specially with Distributed Energy Resources (DERs). In this paper, we focus on striking a balance between optimal economic and resilient operation using novel formulation and developed tool called Resiliency Enabled Energy System Operation Toolbox (RE-ESOT). Simulation results are provided for a real islanded grid in Alaska with battery energy systems.

50 EE - Wind and Water Power Program - Water (EE-4↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

EVI-EnSitePy (Electric Vehicle Infrastructure – Energy Estimation and Site Optimization Tool in Python) [EVI-X Modeling Suite] [SWR-25-07]

EVI-EnSitePy is a comprehensive agent-based tool designed for the analysis and design of high-power charging sites, encompassing a wide array of site agents including Electric Vehicles (EVs), chargers, energy storage units (ESS), renewable energy resources (DER), and loads. This versatile tool offers diverse functionalities and a modular modeling approach, allowing detailed configuration of agents based on power ratings, port numbers, energy capacities, demand requirements, charger interfaces, and flexibility to customize the tool for project specific goals. By simulating agent interactions and employing various metrics, EVI-EnSitePy enables the assessment of site performance, exploration of energy management systems (EMS), and implementation of innovative EV charging policies. Utilizing EV charge schedules and arrival states, the tool performs thorough charging site simulations, with outputs consisting of agent and site-level power profiles and statistical metrics. Employing a tree graph structure, EVI-EnSitePy supports nested site structures and power distribution modeling. The tool's ability to generate charging schedules deterministically or via stochastic analysis further enhances its versatility. Through its features and capabilities, EVI-EnSitePy offers a powerful platform for informed decision-making in the realm of high-power charging site design and operation.

Jackson, Derek [National Renewable Energy Laborato↗