Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Proton Straggling in Thick Silicon Detectors

Straggling functions for protons in thick silicon radiation detectors are computed by Monte Carlo simulation. Mean energy loss is constrained by the silicon stopping power, providing higher straggling at low energy and probabilities for stopping within the detector volume. By matching the first four moments of simulated energy-loss distributions, straggling functions are approximated by a log-normal distribution that is accurate for Vavilov k is greater than or equal to 0:3. They are verified by comparison to experimental proton data from a charged particle telescope.

Selesnick, R. S.↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

CLUST - EVAP Monte Carlo Simulation Applications for Determining Effective Energy Deposition in Silicon by High Energy Protons

The CLUST-EVAP is a Monte Carlo simulation of the interaction of high energy (25 - 400 MeV) protons with silicon nuclei. The initial nuclear cascade stage is modeled using the CLUST model developed by Indiana University over 30 years ago. The second stage, in which the excited nucleus evaporates particles in random directions, is modeled according to the evaporation algorithm provided by H. H. K. Tang of IBM. Using the CLUST-EVAP code to model fragment produ6tion and the Vavilov-Landau theory to model fluctuations in direct ionization in thin silicon layers, we have predicted energy deposition in silicon components for various geometrical configurations. We have compared actual measurements with model predictions for geometry's such as single, thin silicon particle detectors, telescopic particle detectors flown in space to measure the environment, and thin sensitive volumes of modern micro-electronic components. We have recently compared the model predictions with actual measurements made by the DOSTEL spectrometer flown in the Shuttle payload bay on STS-84. The model faithfully reproduces the features and aids in interpretation of flight results of this instrument. We have also applied the CLUST-EVAP model to determine energy deposition in the thin sensitive volumes of modern micro-electronic components. We have accessed the ability of high energy (200 MeV) protons to induce latch-up in certain devices that are known to latch up in heavy ion environments. However, some devices are not nearly as susceptible to proton induced latch-up as expected according to their measured heavy ion latch-up cross sections. The discrepancy is believed to be caused by the limited range of the proton-silicon interaction fragments. The CLUST-EV AP model was used to determine a distribution of these fragments and their range and this is compared to knowledge of the ranges required based on the known device structure. This information is especially useful in accessing the risk to on-orbit perfonnance in a heavy ion environment based on testing performed with only protons.

ONeill, Pat M.↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Energy-Powered Electrochemical Direct Ocean Capture Model

Offshore synthetic fuel production and marine carbon dioxide removal can be enabled by direct ocean capture, which extracts carbon dioxide from the ocean that then can be used as a feedstock for fuel production or sequestered underground. To maximize carbon capture, plants require a variety of low-carbon energy sources to operate, such as variable renewable energy. However, the impacts of variable power on direct ocean capture have not yet been thoroughly investigated. To facilitate future deployments, a generalizable model for electrodialysis-based direct ocean capture plants is created to evaluate plant performance and electricity costs under intermittent power availability. This open-source Python-based model captures key aspects of the electrochemistry, ocean chemistry, post-processing, and operation scenarios under various conditions. To incorporate realistic energy supply dynamics and cost estimates, the model is coupled with the National Renewable Energy Laboratory’s H2Integrate tool, which simulates hybrid energy system performance profiles and costs. This integrated framework is designed to provide system-level insights while maintaining computational efficiency and flexibility for scenario exploration. Initial evaluations show similar results to those predicted by the industry, and demonstrate how a given plant could function with variable power in different deployment locations, such as with wind energy off the coast of Texas and with wind and wave energy off the coast of Oregon. The results suggest that electrochemical systems with greater tolerances for power variability and low minimum power requirements may offer operational advantages in variable-energy contexts. However, further research is needed to quantify these benefits and evaluate their implications across different deployment scenarios.

16 TIDAL AND WAVE POWER↗

Enhancing occupant behavior representation for interoperability between building information modeling and building energy modeling

Building Performance Simulation (BPS) has been adopted as an essential tool for designing, operating, and retrofitting buildings to optimize energy efficiency throughout the building life cycle. The Green Building XML (gbXML) schema facilitates seamless data exchange between Building Information Modeling (BIM) and Building Energy Modeling (BEM) software tools. However, limited occupant behavior (OB) representation in BIM often leads to inconsistent and inaccurate energy simulation in BEM software. This paper presents 154 systematic enhancements to the existing occupant behavior XML (obXML) schema v1.3.4, initially developed for standardizing OB representation for BEM, to address existing limitations and improve interoperability with BIM models. The enhancements encompass improved integration with BIM models through extended building representations and system operations, expanded support for advanced OB models with additional environmental parameters and mathematical capabilities, and implementation of a standardized model documentation framework. To facilitate seamless data transformation between gbXML and obXML schemas, we developed a publicly available gb-obXML Schema Converter. Three case studies demonstrate the enhanced schema’s capabilities: representation of building information using a two-story office building model, documentation of a window operation behavior model, and validation of the schema converter’s functionality. The enhanced obXML schema v1.4 enables sophisticated modeling of occupant-building interactions while maintaining consistency with industry-standard BIM schemas. The standardized documentation framework facilitates reproducibility and knowledge sharing in the OB research community, while the schema converter automates the integration of building information into OB simulation workflows. These enhancements establish a foundation for more accurate building performance simulation by supporting sophisticated representation of occupant behavior within the BIM-to-BEM simulation workflows.

Chung, Jihoon↗

Dark Energy Survey Year 3 results: Simulation-based cosmological inference with wavelet harmonics, scattering transforms, and moments of weak lensing mass maps. II. cosmological results

Here, we present a simulation-based cosmological analysis using a combination of Gaussian and non-Gaussian statistics of the weak lensing mass (convergence) maps from the first three years of the Dark Energy Survey. We implement the following: (1) second and third moments; (2) wavelet phase harmonics; (3) the scattering transform. Our analysis is fully based on simulations, spans a space of seven 𝑤 Cold Dark Matter (𝑤⁢ CDM) cosmological parameters, and forward models the most relevant sources of systematics inherent in the data: masks, noise variations, clustering of the sources, intrinsic alignments, and shear and redshift calibration. We implement a neural network compression of the summary statistics, and we estimate the parameter posteriors using a simulation-based inference approach. Including and combining different non-Gaussian statistics is a powerful tool that strongly improves constraints over Gaussian statistics (in our case, the second moments); in particular, the figure of merit (𝑆 8 , Ω m ) is improved by 70% (Λ ⁢CDM) and 90% (𝑤 ⁢CDM). When all the summary statistics are combined, we achieve a 2% constraint on the amplitude of fluctuations parameter 𝑆 8 ≡ 𝜎 8 ⁢(Ω m /0.3) 0.5 , obtaining 𝑆 8 = 0.794 ±0.017 (Λ⁢ CDM) and 𝑆 8 = 0.817 ±0.021 (𝑤 ⁢CDM), and a ∼10% constraint on Ω m , obtaining Ω m =0.259 ±0.025 (Λ ⁢CDM) and Ω m = 0.273 ±0.029 (𝑤⁢ CDM). In the context of the 𝑤⁢ CDM scenario, these statistics also strengthen the constraints on the parameter 𝑤, obtaining 𝑤 <−0.72. The constraints from different statistics are shown to be internally consistent (with a 𝑝-value>0.1 for all combinations of statistics examined). We compare our results to other weak lensing results from the first three years of the Dark Energy Survey data, finding good consistency; we also compare with results from external datasets, such as planck constraints from the cosmic microwave background, finding statistical agreement, with discrepancies no greater than <2.2⁢𝜎.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of vibrational-translational energy transfer using the direct simulation Monte Carlo method

A new model is proposed for energy transfer between the vibrational and translational modes for use in the direct simulation Monte Carlo method (DSMC). The model modifies the Landau-Teller theory for a harmonic oscillator and the rate transition is related to an experimental correlation for the vibrational relaxation time. Assessment of the model is made with respect to three different computations: relaxation in a heat bath, a one-dimensional shock wave, and hypersonic flow over a two-dimensional wedge. These studies verify that the model achieves detailed balance, and excellent agreement with experimental data is obtained in the shock wave calculation. The wedge flow computation reveals that the usual phenomenological method for simulating vibrational nonequilibrium in the DSMC technique predicts much higher vibrational temperatures in the wake region.

Boyd, Iain D.↗

A simulation model for wind energy storage systems. Volume 2: Operation manual

A comprehensive computer program (SIMWEST) developed for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel, and pneumatic) is described. Features of the program include: a precompiler which generates computer models (in FORTRAN) of complex wind source/storage/application systems, from user specifications using the respective library components; a program which provides the techno-economic system analysis with the respective I/O the integration of system dynamics, and the iteration for conveyance of variables; and capability to evaluate economic feasibility as well as general performance of wind energy systems. The SIMWEST operation manual is presented and the usage of the SIMWEST program and the design of the library components are described. A number of example simulations intended to familiarize the user with the program's operation is given along with a listing of each SIMWEST library subroutine.

Warren, A. W.↗

A thermal, thermoelastic, and wear simulation of a high-energy sliding contact problem

This paper describes an investigation of the sliding contact problem encountered in high-energy disk brakes. The analysis includes a simulation modeling, using the finite element method, of the thermoelastic instabilities that cause transient changes in contact to occur on the friction surface. In order to include the effect of wear of the concentrated contacts on the friction surface, a wear criterion is proposed that results in prediction of wear rates for disk brakes that are quite close to experimentally determined wear rates. The thermal analysis shows that the transient temperature distribution in a disk brake can be determined more accurately by use of this thermomechanical analysis than by a more conventional analysis that assumes constant contact conditions. It is also shown that lower, more desirable, temperatures in disk brakes can be attained by increasing the volume, the thermal conductivity, and especially, the heat capacity of the brake components.

Kennedy, F. E., Jr.↗