Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Two-Phase Bidirectional Heat Exchanger

Heat exchanger transfers heat from one two-phase thermal loop to another. Condenses vapor in one loop while evaporating liquid in other. Transfers heat with very small drops in temperature and pressure, and efficiently joins heat pipes thermally without mixing of their working fluids. Several such heat exchangers used to build long, complex multiloop heat-control systems. Exchanger bidirectional: transfers heat in reverse, condensing on normally evaporating side, and vice versa. Can warm equipment it normally cools, without using auxiliary heater. In reverse transfer, wicks on evaporating side supply liquid continuously by capillary action; reverse-flow pump not needed. Design modified for other working fluids and larger heat-transfer rates.

Kroliczek, Edward↗

Land-Atmosphere Interactions: Successes, Problems and Prospects

After two decades of active research, a much better understanding of the broader role of biospheric processes on the local climate has emerged. A surface-albedo increase, particularly in desert border regions of the subtropics (as well as the deforested tropical regions), leads to a net surface energy deficit, which in turn leads to a relative sinking and reduced rainfall. On the other hand, studies of the influence of altered ratios of evapotranspiration and sensible fluxes, in situations where the net solar income is unchanged, show that evapotranspiration is a more desirable flux for increased precipitation and vitality of the biosphere. Besides providing water vapor and convective available potential energy (CAPE) to the lower troposphere, evapotranspiration helps in building larger CAPE before "turning on" the moist-convection. Larger CAPE in the lower troposphere enables convection to reach into the deeper atmosphere thereby heating the upper troposphere; indeed, moist-convection is also accompanied by the evaporation of falling precipitation that cools and moistens the lower atmosphere. While convective, as opposed to stratiform, precipitation reduces the fractional cloud cover; it also allows more solar radiation to reach the surface thereby invigorating surface fluxes. These, together with moist convection and associated downdrafts help to maintain the characteristic upper temperature limit(s) of the moist-land as well as oceanic regions. Regardless of the above understanding, several important problems continue to hinder the accurate simulation of a realistic land atmosphere interaction in a numerical model (both GCM and/or Meso-scale models). Among the unsolved problems are parameterization of sub-grid scale land processes that include small-scale variability of soil moisture, snow-cover and snow-physics, the biodiversity of the biosphere, orography, local drainage characteristics under natural conditions, and surface flow over the natural terrain. A well-known non-linear response of surface fluxes to these variations makes the problem of parameterizing land-atmosphere interaction processes hard-to-address and simulate, particularly in a GCM. In our presentation, we will discuss how orographic, snow-cover, and water table interactions can be included into a Simple Biosphere Model such as SiB/SSiB. Figure I shows how, in the Russian region, spring snowmelt affects the soil moisture profile. Corresponding figure 2 shows how interaction with the water table decreases the natural evapotranspiration in the Sahel region simulation. While these simulations need better validation with data, the simulations reveal that surface processes are sensitive to these parameterizations. With these developments, we continue to advance our understanding of the interaction of land with the atmosphere aloft, but the intrinsic variability of the newer parameters, e. g., hydraulic properties of the soil, diminish the positive influences of these advances on the improved climate simulation with GCMs.

Sud, Y. C.↗

Cloud Modeling Using Field Project Data for the Study of Precipitation Processes

The use of cloud-resolving models (CRMs) in the study of precipitation process and their relation to the large-scale environment can be generally categorized into two approaches. The first approach is so called "cloud ensemble modeling". In this approach, many clouds of different size in various stages of their lifecycles can be present at any model simulation time. Large-scale effects are derived from observations and imposed into the model as the main forcing. The advantage of this approach is that the modeled convection will be forced to have the same intensity, thermodynamic budget and organization as the obserations.This approach will also allow CRMs to perform multi-day or multi-week time integrations. The second approach usually requires initial temperature and water vapor profiles that have a medium to large CAPE, and open lateral boundary conditions are used. The modeled clouds could be termed "self-forced convection". Model improvements, such as in the microphysics, are achieved using the second approach. In cloud ensemble modeling, accurate large-scale advective tendencies for temperature and water vapor are the main forcing for the CRMs. We found that the large-scale advective terms for temperature and water vapor are not always consistent, For example, large-scale forcing could indicate strong drying which would produce cooling in the model through evaporation but not contain large-scale advective heating to compensate. This discrepancy in forcing would cause differences between the observed and modeled latent heating profiles. Good measurements of other quantities (i.e., surface fluxes and radiation) are also required to perform variational objective analysis that computes and minimizes a "cost function" that constrains the difference between the large-scale advective forcing in temperature and water vapor. With self-forced convection, accurate vertical distributions of temperature, moisture (water vapor), and horizontal winds are required. The timing of the measurements relative to cloud development is crucial (i.e., prior to cloud triggering). Microphysical measurements (i.e., the cloud number concentration and size distribution) can also be used in this second approach but are of secondary importance with cloud ensemble modeling. In this paper, data collected during TRMM field campaigns (FCs; i.e., SCSMEX, LBA and KWAJEX) which were aimed at validating TRMM products (i.e., rainfall and the vertical distribution of latent heating) will be used to examine the impact of errors in the initial conditions (e.g.., soundings an large-scale forcing) on simulated rainfall distributions and brightness. Rainfall and precipitations simulated from a CRM will also be compared with those estimated by a schocastic model.

Tao, W.-K.↗

Expanding a Supercomputer Facility Using Modular Data Center Technology

With the expansion of high-end computing resources needed to support NASA's increasing demands for physics-based simulations, the facility housing Pleiades-the agency's largest supercomputer-recently reached its power and cooling capacity. In response, the NASA Advanced Supercomputing Division at Ames Research Center undertook a prototype project that resulted in a new facility based on modular data center technology. The facility, a ~1000 square-foot module on a concrete pad with room for 16-18 compute racks, was completed in fall 2016 and an SGI computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) of ~1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility wide file system shared by all compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers InfiniBand fabric over fiber-optic links about 300 meters long. The prototype has exceeded expectations and is serving as a blueprint for future expansions.*†

Facility↗

Electra: A Modular-Based Expansion of NASA's Supercomputing Capability

NASA has increasingly relied on high-performance computing (HPC) re- sources for computational modeling, simulation, and data analysis to meet the science and engineering goals of its missions in space exploration, aeronautics, and Earth and space science. The NASA Advanced Supercomputing (NAS) Division at Ames Research Center in Silicon Valley, Calif., hosts NASA’s premier supercomputing resources, integral to achieving and enhancing the success of the agency’s missions. NAS provides a balanced environment, funded under the High-End Computing Capability (HECC) project, comprised of world-class supercomputers, including its flagship distributed-memory cluster, Pleiades; high-speed networking; and massive data storage facilities, along with multi-disciplinary support teams for user support, code porting and optimization, and large-scale data analysis and scientific visualization. However, as scientists have increased the fidelity of their simulations and engineers are conducting larger parameter-space studies, the requirements for supercomputing resources have been growing by leaps and bounds. With the facility housing the HECC systems reaching its power and cooling capacity, NAS undertook a prototype project to investigate an alternative approach for housing supercomputers. Modular supercomputing, or container-based computing, is an innovative concept for expanding NASA’s HPC capabilities. With modular supercomputing, additional containers—similar to portable storage pods—can be connected together as needed to accommodate the agency’s ever-increasing demand for computing resources. In addition, taking advantage of the local weather permits the use of cooling technologies that would additionally save energy and reduce annual water usage. The first stage of NASA’s Modular Supercomputing Facility (MSF) prototype, which resulted in a 1,000 square-foot module on a concrete pad with room for 16 compute racks, was completed in Fall 2016 and an SGI (now HPE) computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) measurement of 1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list [14]. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility-wide file system shared by all HECC compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers in the primary facility over fiber-optic links about 900 feet long. The MSF prototype has exceeded expectations and is serving as a blueprint for future expansions. In the remainder of this chapter, we detail how modular data center technology can be used to expand an existing compute resource. We begin by describing NASA’s requirements for supercomputing and how resources were provided prior to the integration of the Electra module-based system.

Biswas, Rupak↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Tubular sublimatory evaporator heat sink

An evaporative refrigerator or cooler comprising a bundle of spaced, porous walled tubes closed at one of their ends and vented to a vacuum at the other end is disclosed. The tube bundle is surrounded by a water jacket having a hot water inlet distribution manifold and a cooled water outlet through a plenum chamber. Hot water is pumped into the jacket to circulate around the tubes, and when this water meets the vacuum existing inside the tubes, it evaporates thereby cooling the water in the jacket. If cooling proceeds to the point where water penetrating or surrounding all or part of the tubes freezes, operation continues with local sublimation of the ice on the tubes while the circulating water attempts to melt the ice. Both sublimation and evaporation may take place simultaneously in different regions of the device.

Webbon, B. W.↗

Irrigation Induced Surface Cooling in the Context of Modern and Increased Greenhouse Gas Forcing

There is evidence that expected warming trends from increased greenhouse gas (GHG) forcing have been locally masked by irrigation induced cooling, and it is uncertain how the magnitude of this irrigation masking effect will change in the future. Using an irrigation dataset integrated into a global general circulation model, we investigate the equilibrium magnitude of irrigation induced cooling under modern (Year 2000) and increased (A1B Scenario, Year 2050) GHG forcing, using modern irrigation rates in both scenarios. For the modern scenario, the cooling is largest over North America, India, the Middle East, and East Asia. Under increased GHG forcing, this cooling effect largely disappears over North America, remains relatively unchanged over India, and intensifies over parts of China and the Middle East. For North America, irrigation significantly increases precipitation under modern GHG forcing; this precipitation enhancement largely disappears under A1B forcing, reducing total latent heat fluxes and the overall irrigation cooling effect. Over India, irrigation rates are high enough to keep pace with increased evaporative demand from the increased GHG forcing and the magnitude of the cooling is maintained. Over China, GHG forcing reduces precipitation and shifts the region to a drier evaporative regime, leading to a relatively increased impact of additional water from irrigation on the surface energy balance. Irrigation enhances precipitation in the Middle East under increased GHG forcing, increasing total latent heat fluxes and enhancing the irrigation cooling effect. Ultimately, the extent to which irrigation will continue to compensate for the warming from increased GHG forcing will primarily depend on changes in the background evaporative regime, secondary irrigation effects (e.g. clouds, precipitation), and the ability of societies to maintain (or increase) current irrigation rates.

Cook, Benjamin I.↗

A reconnection mechanism for coronal condensations in two-ribbon flares

The series of self-consistent, two-dimensional, MHD calculations used to explore the reconnection dynamics implicit in the two-ribbon flare model of Kopp and Pneumann (1976) indicate that there exists, in addition to the standard, slow mode MHD shocks generated by reconnection, a standing, fast mode MHD shock. Due to thermal conduction, the slow shocks generate an evaporative upflow of chromospheric plasma into the reconnection region; an analysis of these effects of radiative and conductive cooling suggests that at least some of this evaporated plasma will undergo thermal condensation in passing through the fast shock.

Forbes, T. G.↗

Heat transfer, diffusion, and evaporation

Although it has long been known that the differential equations of the heat-transfer and diffusion processes are identical, application to technical problems has only recently been made. In 1916 it was shown that the speed of oxidation of the carbon in iron ore depends upon the speed with which the oxygen of the combustion air diffuses through the core of gas surrounding the carbon surface. The identity previously referred to was then used to calculate the amount of oxygen diffusing to the carbon surface on the basis of the heat transfer between the gas stream and the carbon surface. Then in 1921, H. Thoma reversed that procedure; he used diffusion experiments to determine heat-transfer coefficients. Recently Lohrisch has extended this work by experiment. A technically very important application of the identity of heat transfer and diffusion is that of the cooling tower, since in this case both processes occur simultaneously.

GASES - DIFFUSION↗

Heat-Pipe Array for Large-Area Cooling

High rates of heat transfer anticipated. Prototype evaporative cold plate gathers waste heat from equipment mounted on it. Plate made by welding together flanges of several sections of heat pipe. Since plate separates liquid and vapor phases at inlet and outlet ports, eliminates complexities and uncertainties of two-phase flow in zero gravity. On earth, inlet valve enables plate to operate at relatively-large height differences with other plates in same system.

Edelstein, F.↗

Method of evaporation

Liquids, such as juices, milk, molten metal and the like are concentrated by forming uniformly-sized, small droplets in a precision droplet forming assembly and deploying the droplets in free fall downwardly as a central column within an evacuated column with cool walls. A portion of the solvent evaporates. The vapor flows to the wall, condenses, and usually flows down the wall as a film to condensate collector and drain. The vertical column of freely falling droplets enters the splash guard. The condensate can be collected, sent to other towers or recycled.

Dufresne, Eugene R.↗

Hollow Fiber Space Suit Water Membrane Evaporator Development for Lunar Missions

The Space Suit Water Membrane Evaporator (SWME) is the baseline heat rejection technology selected for development for the Constellation lunar suit. The Hollow Fiber (HoFi) SWME is being considered for service in the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) to provide cooling to the thermal loop through water evaporation to the vacuum of space. Previous work described the test methodology and planning to compare the test performance of three commercially available hollow fiber materials as alternatives to the sheet membrane prototype for SWME: 1) porous hydrophobic polypropylene, 2) porous hydrophobic polysulfone, and 3) ion exchange through nonporous hydrophilic modified Nafion. Contamination tests were performed to probe for sensitivities of the candidate SWME elements to organics and non-volative inorganics expected to be found in the target feedwater source, i.e., potable water provided by the vehicle. The resulting presence of precipitate in the coolant water could plug pores and tube channels and affect the SWME performance. From this prior work, a commercial porous hydrophobic hollow fiber was selected to satisfy both the sensitivity question and the need to provide 800 W of heat rejection. This paper describes the trade studies, the design methodology, and the hollow fiber test data used to design a full

Bue, Grant C.↗

The geometry and physical properties of exhaust clouds generated during the static firing of S-1C and S-2 rocket engines

An experimental program was conducted during the static firing of the S-1C stage 13, 14, and 15 rocket engines and the S-2 stage 13, 14, and 15 rocket engines. The data compiled during the experimental program consisted of photographic recordings of the time-dependent growth and diffusion of the exhaust clouds, the collection of meteorological data in the ambient atmosphere, and the acquisition of data on the physical structure of the exhaust clouds which were obtained by flying instrumented aircraft through the clouds. A new technique was developed to verify the previous measurements of evaporation and entrainment of blast deflector cooling water into the cloud. The results of the experimental program indicate that at the lower altitudes the rocket exhaust cloud or plume closely resembles a free-jet type of flow. At the upper altitudes, where the cloud is approaching an equilibrium condition, structure is very similar to a natural cumulus cloud.

Forbes, R. E.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

The feasibility of water injection into the turbine coolant to permit gas turbine contingency power for helicopter application

It is pointed out that in certain emergency situations it may be desirable to obtain power from a helicopter engine at levels greater than the maximum rating. Yost (1976) has reported studies concerning methods of power augmentation in the one engine inoperative (OEI) case. It was found that a combination of water/alcohol injection into the inlet and overtemperature/overspeed could provide adequate emergency power. The present investigation is concerned with the results of a feasibility study which analytically investigated the maximum possible level of augmentation with constant gas generator turbine stress rupture life as a constraint. In the proposed scheme, the increased engine output is obtained by turbine overtemperature, however, the temperature of the compressor bleed air used for hot section cooling is lowered by injecting and evaporating water.

Van Fossen, G. J.↗

Ocean-Atmosphere Interaction Over Agulhas Extension Meanders

Many years of high-resolution measurements by a number of space-based sensors and from Lagrangian drifters became available recently and are used to examine the persistent atmospheric imprints of the semi-permanent meanders of the Agulhas Extension Current (AEC), where strong surface current and temperature gradients are found. The sea surface temperature (SST) measured by the Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) and the chlorophyll concentration measured by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) support the identification of the meanders and related ocean circulation by the drifters. The collocation of high and low magnitudes of equivalent neutral wind (ENW) measured by Quick Scatterometer (QuikSCAT), which is uniquely related to surface stress by definition, illustrates not only the stability dependence of turbulent mixing but also the unique stress measuring capability of the scatterometer. The observed rotation of ENW in opposition to the rotation of the surface current clearly demonstrates that the scatterometer measures stress rather than winds. The clear differences between the distributions of wind and stress and the possible inadequacy of turbulent parameterization affirm the need of surface stress vector measurements, which were not available before the scatterometers. The opposite sign of the stress vorticity to current vorticity implies that the atmosphere spins down the current rotation through momentum transport. Coincident high SST and ENW over the southern extension of the meander enhance evaporation and latent heat flux, which cools the ocean. The atmosphere is found to provide negative feedback to ocean current and temperature gradients. Distribution of ENW convergence implies ascending motion on the downwind side of local SST maxima and descending air on the upwind side and acceleration of surface wind stress over warm water (deceleration over cool water); the convection may escalate the contrast of ENW over warm and cool water set up by the dependence of turbulent mixing on stability; this relation exerts a positive feedback to the ENW-SST relation. The temperature sounding measured by the Atmospheric Infrared Sounder(AIRS) is consistent with the spatial coherence between the cloud-top temperature provided by the International Satellite Cloud Climatology Project (ISCCP) and SST. Thus ocean mesoscale SST anomalies associated with the persistent meanders may have a long-term effect well above the midlatitude atmospheric boundary layer, an observation not addressed in the past.

Atmospheric Infrared Sounder (AIRS)↗