Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Evaporation and propagation of liquid drop streams at vacuum pressures: Experiments and modeling

Evaporation of streams of liquid droplets in environments at vacuum pressures below the vapor pressure has not been widely studied. Here, experiments and simulations are reported that quantify the change in droplet diameter when a steady stream of ≈100 μm diameter drops is injected into a chamber initially evacuated to <10 –8 bar. In experiments, droplets fall through the center of a 0.8 m long liquid nitrogen cooled shroud, simulating infinity radiation and vapor mass flux boundary conditions. Furthermore, experimentally measured changes in drop diameters vary from ≈0 to 6 μm when the initial vapor pressure is increased from 10 –6 to 10 –3 bar by heating the liquid. Measured diameter changes are predicted by a model based on the Hertz-Knudsen equation. One uncertainty in the calculation is the “sticking coefficient” β. Assuming a constant β for all conditions studied here, predicted diameter changes best match measurements with β≈0.3. This value falls within the range of β reported in the literature for organic liquids. Finally, at the higher vapor pressure conditions considered here, the drop stream disperses transverse to the main flow direction. This spread is attributed to forces imparted by an absolute pressure gradient produced by the evaporating stream.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermoeconomic Evaluation and Optimization of Using Different Environmentally Friendly Refrigerant Pairs for a Dual-Evaporator Cascade Refrigeration System

Applications of dual-evaporator refrigeration systems have recently gained much attention both in academia and industry due to their multiple benefits. In this study, a comprehensive thermodynamic and economic analysis is conducted to evaluate the potential of using several environmentally friendly refrigerant couples and identifies the most suitable one yielding the best economic results. To achieve this goal, a detailed parametric study is conducted, and an optimization process is performed using a particle swarm optimization (PSO) approach to minimize the unit production cost of cooling (UPCC) of the cascade refrigeration system. The results showed that among all selected 18 refrigerant pairs and for all ranges of examined operating parameters, the R170-R161 pair and R1150-R1234yf pair are identified as the best and worst pairs, respectively, from both thermodynamic and economic viewpoints. The results also confirm that R170-R161 pair has an improvement over R717-R744, used as a typical refrigerant pair of cascade refrigeration cycles. For a base case analysis, the COP of R170-R161 and R1150-R1234yf pairs is determined as 1.727 and 1.552, respectively, while their UPCC is found to be $0.395/ton-hr and $0.419/ton-hr, respectively, showing the influence of proper selection of refrigerant pairs on the cascade cycle’s performance. Overall, this study offers a useful thermodynamic and economic insight regarding the selection of proper refrigerant pairs for a dual-evaporator cascade vapor compression refrigeration system.

42 ENGINEERING↗

Spectroscopic Studies of Charge-Transfer Character and Photoresponses of F 4 TCNQ-Based Donor–Acceptor Complexes

F 4 TCNQ (2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane) is used widely as a hole-doping agent in photoresponsive organic semiconducting materials, yet relatively little is known about the photoresponses of the F 4 TCNQ· - anion generated via doping. Furthermore, there is still relatively little systematic exploration of how the properties of the local material or chemical environment impacts the driving force for generating these charge-transfer complexes. Here we present spectroscopic and photophysical studies of F 4 TCNQ in charge-transfer complexes (CTCs) with the electron donor N,N’-Diphenyl-N-N’-di-p-tolylbenzene-1,4-diamine (MPDA) both in dichloroethane solution and polystyrene matrices. Integer charge transfer (ICT) between donor and acceptor occurs readily in dichloroethane solvent to form F 4 TCNQ· - :MPDA + CTCs, due to a ~150 mV difference in MPDA + /MPDA and F 4 TCNQ/F 4 TCNQ· - reduction potentials. Ultrafast spectroscopic studies of the CTC as well as electrochemically generated F 4 TCNQ· - and MDPA + reveal that the photoresponses of these CTCs are dominated by that of the dopant anion, including rapid deactivation (800 fs) after excitation to the anion D 1 excited state, followed by slower (~10 ps) vibrational cooling in the anion D 0 state. Excitation to the higher-lying D 2 state results in a rapid relaxation to the D 1 state, in contrast to direct D 2 -D 0 relaxation previously observed for F 4 TCNQ· - in gas phase. CTCs embedded in polystyrene (PS) matrices are observed to lose their integer charge-transfer character upon evaporation of solvent, as evidenced by changes to electronic and vibrational absorption features associated with F 4 TCNQ· - . This change is attributed to the loss of solvent stabilization of the ion pair formed through the charge-transfer reaction. Ultrafast spectral measurements reveal that the photoresponses of the partial charge-transfer (PCT) species embedded in PS are still highly similar to those of the ICT species and unlike that of neutral F 4 TCNQ, implying the electronic properties of the PCT state are likewise dominated by properties of the reduced acceptor molecule. We conclude that excitation of ICT or PCT states introduces optical losses for photoresponses of doped organic semiconductor materials due to the large anion absorption cross section and its rapid, dissipative deactivation dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗

The Strength of Coupling to the Southern Ocean Modulates Tropical Eastern Pacific Variability and Forced Response

Despite rising global-mean temperatures, large parts of the Southern Ocean and tropical eastern Pacific Ocean have cooled during the satellite era. These regions may be linked by teleconnections, with Southern Ocean cooling contributing to tropical eastern Pacific cooling. We demonstrate that, on average, state-of-the-art Earth system models (ESMs) underestimate the magnitude of interaction between the Southern Ocean and tropical eastern Pacific Ocean. The strength of the teleconnection is shown to be mediated by the magnitude of the positive cloud–sea surface temperature (SST) feedback in the subtropical eastern Pacific Ocean and the strength of the wind–evaporation–SST (WES) feedback. We link excessive precipitation in the tropical Pacific south of the equator to the strength of the Southern Ocean–eastern Pacific teleconnection. This model bias, known as the double intertropical convergence zone (ITCZ), is shown to be related to erroneous convection south of the equator, weakened cross-equatorial trade winds, and unfavorable meteorological conditions for marine boundary layer subtropical clouds. We postulate there is a two-way interaction, in which a double-ITCZ occurs with weaker cloud–SST and WES feedbacks, which in turn impact local SSTs and amplify the double-ITCZ. Models with a stronger Southern Ocean to tropical Pacific teleconnection tend to exhibit more multidecadal variability in the Walker circulation, ITCZ, and west–east equatorial SST gradient, as well as greater delayed warming in the tropical eastern Pacific Ocean resulting from delayed Southern Ocean warming under greenhouse gas forcing. These results provide insight into why ESMs struggle to replicate observed tropical Pacific temperature trend patterns and point to ITCZ location as a key target for improvement in future model development.

Climate change↗

Surface heat flux and its association with the MJO in the tropical western Pacific using ARM observations

The Madden-Julian oscillation (MJO) is a major atmospheric phenomenon in the tropics that moves eastward every 20 to 100 days. It brings heavy rain and strong winds, influencing extreme weather events far beyond the tropics – including flooding, hurricanes, tornadoes and heavy snow in the United States. Therefore, an improved understanding of the MJO is critical for enhancing weather forecasts and supporting better decision-making for communities, emergency managers, and the private sector. Past studies, based on short-term observations or long-term model data, have emphasized the dominant role of atmospheric humidity in driving the MJO. Our research, using long-term observations (2000-2014) from three U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) sites in the tropical western Pacific (Manus, Nauru, and Darwin) confirms those past findings. However, we also show that atmospheric temperature, especially in the mid and upper troposphere, also plays a key role in the MJO’s evolution from its quiet (suppressed) to convective (active) phase. These findings provide valuable insights into how the MJO evolves and may help evaluate and improve weather and climate models. Our study also examined how the exchange of heat between the Earth's surface and the atmosphere, called surface heat flux, interacts with the MJO. This flux includes components such as latent heat (related to evaporation), sensible heat (related to temperature difference between surface and atmosphere), and radiation. We found that modulation in MJO convection is well connected to surface heat flux over the tropical western Pacific. One surface heat flux component often overlooked is the sensible heat flux due to precipitation (Q P ). Since falling raindrops are typically cooler than the land or ocean surface, they can cool the surface and affect local weather. To test the impact of Q P on convection during MJO, we incorporated it into a weather model, and ran simulations for two periods: April 2009 (when the MJO was active) and June 2006 (when it was not). Including Q P reduced errors in simulating the daily peak of rainfall—by 83% during the strong MJO and 23% during the inactive phase. It also improved the timing of peak daily rainfall and reduced the overall precipitation error by about 10%. These improvements were especially noticeable during periods of heavy rainfall. Our results suggest that even small heat exchanges from rainfall can play a significant role in shaping local weather. Accounting for these effects, particularly in regions like the tropical islands, can lead to more accurate simulations of the MJO-associated precipitation.

54 ENVIRONMENTAL SCIENCES↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Fluid Dynamics Effects on Microstructure Prediction in Single-Laser Tracks for Additive Manufacturing of IN625

Single-track laser fusion were simulated using a heat-transfer-solidification-only (HTS) model and its extension with fluid dynamics (HTS_FD) model using a parallel open-source code, which included laminar fluid dynamics, flat-free surface of the molten alloy, heat transfer, phase-change, evaporation, and surface tension phenomena. The results illustrate that the fluid dynamics affects the solidification and ensuing microstructure. For the HTS_FD simulations, thermal gradient, G was found to exhibit a maximum at the extremity of the solidified pool ( i.e. , at the free surface), while for HTS simulations, G exhibited a maximum around the entire edge of the solidified pool. HTS_FD simulations predicted a wider range of cooling rates than the HTS simulations, exhibited an increased spread in the solidification speed, V variation within the melt-pool with respect to the HTS model results. Primary dendrite arm spacing (PDAS) were evaluated based on power law correlations and marginal stability theory models using the ( G , V ) from HTS and HTS_FD simulations to quantify the effect of the fluid dynamics on the microstructure. At low-laser powers and low-scan speeds, the PDAS obtained with the fluid dynamics model (HTS_FD) was larger by more than 30 pct with respect to the PDAS calculated with the simple HTS model. A new PDAS correlation, i.e. , \( \lambda_{1} \left[ {\mu {\text{m}}} \right] = 832\;G\left[ {\text{K/m}} \right]^{ - 0.5} V\left[ {\text{m/s}} \right]^{ - 0.25} \) , which uses the ( G , V ) results from the HTS_FD model was developed and validated against experimental results.

36 MATERIALS SCIENCE↗

Realistic fuel spray modeling for gasoline direct injection engine applications

Fuel spray modeling plays a critical role during modern gasoline direct injection (GDI) engine development due to fuel injection’s dominant impact on engine performance and emissions as well as the complex physical processes involved. In engineering three-dimensional (3D) computational fluid dynamics (CFD) simulations, the liquid-phase fuel atomization, evaporation, and mixing are usually modeled with the discrete droplet model (DDM) adopting a Lagrangian approach for multiphase CFD simulations. To this end, general practices heavily depend on the reduced order characterization of the injector nozzle flow. However, such simplified injector modeling may lead to insufficient representations of the complex spray dynamics. To tackle this problem, this study proposes a novel workflow to numerically evaluate GDI sub-cooled and flash-boiling sprays under engine-relevant conditions using a side-mounted GDI injector together with real gasoline fuel properties. The workflow introduces a one-way coupling (OWC) method leveraging high-fidelity nozzle flow simulations to provide realistic boundary conditions to the Lagrangian injector model. The proposed workflow was first verified in a constant volume chamber (CVC) environment and then implemented in a practical GDI engine setup to study spray morphology, fuel-air mixing, and wall-wetting propensity. In addition, detailed comparison was performed between the OWC method and the conventional rate of injection (ROI) routine. In conclusion, quantitative analysis of spray characteristics was conducted to highlight possible source of discrepancies of the conventional ROI method.

33 ADVANCED PROPULSION SYSTEMS↗

Mechanisms of Retention and Transport of Fission Products in Virgin and Irradiated Nuclear Graphite

To fulfill the design and licensing requirements for advanced reactors, the U.S. Department of Energy (DOE) is specifically interested in targeted research to quantify the mechanisms of fission product transport and retention in graphitic grades that will likely be used in next-generation very/high temperature reactors, fluoride salt-cooled high temperature reactors and molten salt reactors. We have examined an integrated experimental-computational approach to determine the diffusivities of selected fission products – ruthenium (Ru) and silver (Ag) in five nuclear graphite grades – POCO AXF-5Q, POCO ZXF-5Q, PCEA, IG110, and NBG-18. Experimental investigation for diffusion of other fission products (iodine, cesium, and krypton) in graphite could not be carried out due to extreme evaporation due to high vapor pressure, despite several attempts incorporating various experimental schemes. Experimental investigation with irradiated graphite could not be carried out because necessary approval to transport irradiated graphite could not be obtained due to procedural reasons at ORNL and national policy change in UK. An effort was made to “produce” by ion sputtering, but it was discontinued because the outcome did not adequately represent irradiated graphite. Thin film and “cup-and-cap” methods were employed to deposit fission products, diffusion annealed were carried out in an argon atmosphere, and concentration profiles were determined by dynamic secondary ion mass spectroscopy depth profiling technique. Regardless of graphite type, anomalous diffusion behavior of Ru (i.e., lower than expected based on Arrhenius temperature dependence) at an intermediate temperature, around 600 to 700 °C, was observed. Diffusion behavior of silver on the other hand agreed well to the Arrhenius temperature dependence although the excessive evaporation of silver hampered the accurate determination of diffusivities at temperature higher than 900 °C. In general, silver was observed to diffuse faster than Ru in the temperature range compared from 500 to 900 °C, had consistently had higher pre-exponential factor corresponding to higher jump frequency. To understand the abnormal diffusional behavior of Ru in graphite in intermediate temperature range, a detailed microstructural analysis was carried out. Clustering of Ru into particles on the surface of graphite was observed around 700 °C corresponding to de-wetting and spheroidization. This change would influence the boundary condition of diffusion, although features of clustering was much smaller (<1 mm) than the SIMS raster size (120 x 120 mm). Raman spectroscopy also demonstrated that Raman peak intensity for Ru decreased significantly for samples annealed higher than 700 °C and presence of Ru in graphite altered the crystallinity of graphite. To further elucidate the abnormal diffusion behavior observed in intermediate temperature investigated, the vibrational properties of graphene, bilayer graphene and Kr atoms in bilayer graphene were investigated with molecular dynamics. Krypton, which is a fission product, was introduced between a bilayer graphene system to evaluate (i) whether the phonon dispersion curves change with high temperature in bilayer graphene (ii) whether the addition of Kr atoms between the bilayer introduces any significant change in the vibrational properties, and (iii) whether any change in the vibrational properties can be correlated to the diffusive behavior of Kr atoms. The results show that the Kr atoms indeed exhibit an anomalous diffusive behavior at 550°C. Phonon analysis shows that a few phonon frequencies are enhanced as much as 20 to 30 % with the addition of just 0.2 at.% Kr. So, this may explain the unexpected self-diffusivity of fission products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental study of steam-driven ejector heat pump

Ejector-driven systems have been shown to be promising for heating applications. Most of the research works have been devoted to cooling purposes, while little attention has been focused on heating applications. An experimental steam ejector heat pump system (EHP) was designed and constructed to assess its applicability to water heating applications. The effect of the primary nozzle exit position (NXP) on the performance of the steam ejector system was investigated for primary nozzle throat diameter of 1.5 mm and 2.0 mm. The ejector system was run for high-temperature evaporator (HTE) temperatures of 120, 130, and 140 °C and low-temperature evaporator (LTE) temperatures of 10, 15, and 20 °C. The target of this investigation was to attain the highest condensing temperature to be able to use the proposed system for water heating purposes. The ejector heat pump coefficient of performance (EHP COP) was used to determine the system efficiency. Larger LTE temperatures were found to result in higher EHP COPs and condensing temperatures. A maximum EHP COP of 2.02 was attained for a HTE and LTE temperatures of 120 °C and 20 °C, respectively; however only resulted in a condensing temperature of 22.88 °C. Higher HTE temperatures were found to result in higher condensing temperatures but at the cost of EHP COP.

Spitzenberger, Jeremy↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

Little, Bethany J. (ORCID:0000000332892798)↗