Search NASA⌕ Search

SEARCH · Search NASA

Results for “extract”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Extracting Nucleon Magnetic Moments and Electric Polarizabilities from Lattice QCD in Background Electric Fields

Nucleon properties are investigated in background electric fields. As the magnetic moments of baryons affect their relativistic propagation in constant electric fields, electric polarizabilities cannot be determined without knowledge of magnetic moments. We devise combinations of baryon two-point functions in external electric fields to isolate both observables. Using an ensemble of anisotropic gauge configurations with dynamical clover fermions, we demonstrate how magnetic moments and electric polarizabilities can be determined from lattice QCD simulations in background electric fields. We obtain results for both the neutron and proton. Our study is currently limited to electrically neutral sea quarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of the Ratio B(t{yields}Wb)/B(t{yields}Wq) and Extraction of V{sub tb}

We present a measurement of the ratio of top quark branching fractions R=B(t{yields}Wb)/B(t{yields}Wq), where q can be a d, s, or b quark, in the lepton+jets and dilepton tt final states. The measurement uses data from 5.4 fb{sup -1} of pp collisions collected with the D0 detector at the Fermilab Tevatron Collider. We measure R=0.90{+-}0.04, and we extract the Cabibbo-Kobayashi-Maskawa (CKM) matrix element |V{sub tb}| as |V{sub tb}|=0.95{+-}0.02, assuming unitarity of the 3x3 CKM matrix.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-line holographic imaging and electron density extraction of ultrafast ionized air filaments

In-line spatial holographic methods are used to image the optical diffraction patterns of ultrafast laser produced plasma filaments in air. Using femtosecond laser pump-probe methods the plasma filament is produced and subsequently probed by a time-delayed probe beam traversing the filament at a right angle. The resulting probe beam image is recorded as a holographic diffraction pattern on a charge coupled device camera as the probe beam is diffracted due to the optical index change caused by the plasma filament. Extraction of the electron density in the filament down to 10{sup 16} cm{sup -3} is obtained by using the Helmholtz wave equation beam propagation model to simulate the data. By varying the pump-probe optical time delay, a plasma electron recombination time of approximately 250 ps is measured and agrees with our rate equation population kinetics model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring uncertainty by extracting fuzzy rules using rough sets and extracting fuzzy rules under uncertainty and measuring definability using rough sets

Computers are not designed to handle terms where uncertainty is present. To deal with uncertainty, techniques other than classical logic must be developed. This paper examines the concepts of statistical analysis, the Dempster-Shafer theory, rough set theory, and fuzzy set theory to solve this problem. The fundamentals of these theories are combined to provide the possible optimal solution. By incorporating principles from these theories, a decision-making process may be simulated by extracting two sets of fuzzy rules: certain rules and possible rules. From these rules a corresponding measure of how much we believe these rules is constructed. From this, the idea of how much a fuzzy diagnosis is definable in terms of its fuzzy attributes is studied.

Worm, Jeffrey A.↗

Extractant compositions for co-extracting cesium and strontium, a method of separating cesium and strontium from an aqueous feed, and calixarene compounds

A mixed extractant solvent that includes at least one dialkyloxycalix[4]arenebenzocrown-6 compound, 4',4',(5')-di-(t-butyldicyclohexano)-18-crown-6, at least one modifier, and, optionally, a diluent. The dialkyloxycalix[4]arenebenzocrown-6 compound is 1,3-alternate-25,27-di(octyloxy)calix[4]arenebenzocrown-6, 1,3-alternate-25,27-di(decyloxy)calix[4]arenebenzocrown-6, 1,3-alternate-25,27-di(dodecyloxy)calix[4]arenebenzocrown-6, 1,3-alternate-25,27-di(2-ethylhexyl-1-oxy)calix[4]arenebenzocrown-6, 1,3-alternate-25,27-di(3,7-dimethyloctyl-1-oxy)calix[4]arenebenzocrown-6, 1,3-alternate-25,27-di(4-butyloctyl-1-oxy)calix[4]arenebenzocrown-6, or combinations thereof. The modifier is a primary alcohol. A method of separating cesium and strontium from an aqueous feed is also disclosed, as are dialkyloxycalix[4]arenebenzocrown-6 compounds and an alcohol modifier.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the absolute branching fractions for D{sub s}{sup -}{yields}l{sup -}{nu}{sub l} and extraction of the decay constant f{sub D{sub s}}

The absolute branching fractions for the decays D{sub s}{sup -}{yields}l{sup -}{nu}{sub l} (l=e, {mu}, or {tau}) are measured using a data sample corresponding to an integrated luminosity of 521 fb{sup -1} collected at center-of-mass energies near 10.58 GeV with the BABAR detector at the PEP-II e{sup +}e{sup -} collider at SLAC. The number of D{sub s}{sup -} mesons is determined by reconstructing the recoiling system DKX{gamma} in events of the type e{sup +}e{sup -}{yields}DKXD{sub s}{sup *-}, where D{sub s}{sup *-}{yields}D{sub s}{sup -}{gamma} and X represents additional pions from fragmentation. The D{sub s}{sup -}{yields}l{sup -}{nu}{sub l} events are detected by full or partial reconstruction of the recoiling system DKX{gamma}l. The branching fraction measurements are combined to determine the D{sub s}{sup -} decay constant f{sub D{sub s}}=(258.6{+-}6.4{+-}7.5) MeV, where the first uncertainty is statistical and the second is systematic.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗