Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Plasma Synthesized Doped Boron Nanopowder for MgB 2 Superconductors

Under this program, a process to synthesize nano-sized doped boron powder by a plasma synthesis process was developed and scaled up from 20 gram batches at program start to over 200 grams by program end. Over 75 batches of boron nanopowder were made by RF plasma synthesis. Particle sizes were typically in the 20-200 nm range. The powder was synthesized by the reductive pyrolysis of BCl 3 in hydrogen in an RF plasma. A wide range of process parameters were investigated including plasma power, torch geometry, gas flow rates, and process pressure. The powder-in-tube technique was used to make monofilament and multifilament superconducting wires. MgB 2 wire made with Specialty Materials plasma synthesized boron nanopowder exhibited superconducting properties that significantly exceeded the program goals. Superconducting critical currents, J c , in excess of 10 5 A cm -2 at magnetic fields of 8 tesla were reproducibly achieved. The upper critical magnetic field in wires fabricated with program boron powder were H c2 (0) = 37 tesla, demonstrating the potential of these materials for high field magnet applications. T c in carbon-doped MgB 2 powder showed a systematic decrease with increasing carbon precursor gas flows, indicating the plasma synthesis process can give precise control over dopant concentrations. Synthesis rates increased by a factor of 400% over the course of the program, demonstrating the scalability of the powder synthesis process. The plasma synthesis equipment at Specialty Materials has successfully and reproducibly made high quality boron nanopowder for MgB 2 superconductors. Research and development from this program enabled Specialty Materials to successfully scale up the powder synthesis process by a factor of ten and to double the size of its powder pilot plant. Thus far the program has been a technical success. It is anticipated that continued systematic development of plasma processing parameters, dopant chemistry and concentration, wire processing technology, and collection technology will lead to the commercialization of boron nanopowder as a precursor for MgB 2 superconductors. Potential commercial applications include magnets for magnetic resonance imaging (MRI), fault current limiters, wind turbine generators.

08 HYDROGEN↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Active Quenching Technique for YBCO Tapes: Quench Acceleration and Protection

The application of resistive-type superconducting fault current limiters (RSFCLs) in electrical networks is very attractive due to their relative compactness, light weight, and good performance. However, this technology still has drawbacks: asymmetrical quench, uncertain limiting velocity, passive action and incapability of enlarging capacity. Here, we present an active quenching technique which can potentially solve these problems. The quenching process is triggered using high-frequency (HF) AC fields, which are generated by two coupled copper coils attached on both sides of the YBCO sample. Our experiments show that this approach is effective in guaranteeing uniform quench and therefore is expected to be able to significantly extend the service life of the device. Moreover, the quench speed can be considerably increased by the HF field. We find that the performance of acceleration is positively correlated to the transport current, intensity and frequency of the AC field. In addition, a DC magnetic field is added around the sample holder simultaneously with the AC field, to study the field-angular-frequency dependence of the quench time t(B{sub AC}f{sub AC}B{sub DC}𝜃{sub DC}). Experimental results prove that the DC magnetic field can cooperate with the HF AC field to accelerate quench, which means better performance can be produced with lower costs with the two fields acting together. In all, this technique showed outstanding performance regarding quench acceleration and tape protection. We believe the HF-assisted quenching technology has a promising future in current-limiting devices and hope our findings could be helpful for its potential applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Customized MgB{sub 2} Superconducting Wire Toward Practical Applications at Sam Dong in Korea

MgB{sub 2} superconducting wire from Sam Dong Co., Ltd. in Korea is suitable for various applications, including medical resonance imaging, fault current limiters, power cables, and transformers. So far, issues related to the wire production cost, current-carrying capacity, and conductor length (kilometers) are very important for further commercialization. Since 2014, our intensive research efforts have led to notable progress. Herein, we summarize and discuss our advanced research for achieving high-performance, scalable, and cost-effective MgB{sub 2} wires at Sam Dong. Based on our accumulated technical know-how, we will continue to fabricate more competitive and efficient MgB{sub 2} superconducting wires that will be suitable for the customer’s purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polyamide 66 as a Cryogenic Dielectric

Improvements in superconductor and cryogenic technologies enable novel power apparatus, \eg, cables, transformers, fault current limiters, generators, \etc, with better device characteristics than their conventional counterparts. In these applications electrical insulation materials play an important role in system weight, footprint (size), and voltage level. The trend in the electrical insulation material selection has been to adapt or to employ conventional insulation materials to these new systems. However, at low temperatures, thermal contraction and loss of mechanical strength in many materials make them unsuitable for superconducting power applications. In this paper, a widely used commercial material was characterized as a potential cryogenic dielectric. The material is used in ``oven bag'' a heat-resistant polyamide (nylon) used in cooking (produced by Reynolds\textregistered, Richmond, VA, USA). It is first characterized by Fourier transform infrared and x-ray diffraction techniques and determined to be composed of polyamide 66 (PA66) polymer. Secondly the complex dielectric permittivity and dielectric breakdown strength of the PA66 films are investigated. The dielectric data are then compared with data reported in the literature. A comparison of dielectric strength with a widely used high-temperature superconductor electrical insulation material, polypropylene-laminated paper (PPLP\texttrademark\ a product of Sumitomo Electric Industries, Japan), is provided. It is observed that the statistical analysis of the PA66 films yields 1\% failure probability at $127\ \kilo\volt\milli\meter^{-1}$; this value is approximately $46\ \kilo\volt\milli\meter^{-1}$ higher than PPLP\texttrademark. It is concluded that PA66 may be a good candidate for cryogenic applications. Finally, a summary of dielectric properties of some of the commercial tape insulation materials and various polymers is also provided.

36 MATERIALS SCIENCE↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis the configuration of earthing system based on high-low and low-high soil structure

Each TNB transmission tower requires a tower footing resistance (TFR) with a lower grounding resistance value that depends on the transmission line voltage. For 132kV and 275kV tower, the TFR must less than 10Ω and 500kV tower must less than 5Ω. The TFR is changeable with variable factors such as soil resistivity. Low TFR provides essential protection to the fault such as lightning strike that may occur at any time. The fault current flow to the lowest resistance path and easily disperses to earth. Back flashover voltage across the insulator of transmission lines may occur when the TFR is high. The TFR is influenced by soil resistivity. There are three parameters affecting the soil resistivity; moisture content, salt content and temperature of the soil. High moisture content in soil will reduce the soil resistivity and resultant low TFR. Small scale moisture control by using Micro Reservoir (MR) irrigation with semi-permeable membranes have the power to offer the stable moisture in soil. By using osmosis concept, it is the process of net movement of water molecules from high potential water to lower potential water though a semi permeable membrane. The MR can withstand for 3 to 5 days without continuous water supply. The MR installed in the centre of the tower that contains a multiple parallel of electrode rods. The concentrated of electrode rods grounding configuration with a combination of MR will improve the TFR even at multilayer soil. As a result, MR gives a little improvement to TFR. The MR in area of concentrated electrode rod configuration to ensure the soil always wet and moist at all times. The changes in soil affect the tower-footing-resistance. The tower-footing-resistance measurement at afternoon is higher than at evening because of the temperature and moisture content in soil is change due to sun radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Cooling Configuration Design Considerations for Long-Length HTS Cables

Recent successes in demonstrating high temperature superconducting (HTS) cable systems hundreds of meters in length have inspired even longer length projects. A compact and energy efficient cooling configuration can be achieved using a counterflow-cooling arrangement. This is particularly attractive when all three phases are contained in a single cryostat because of the elimination of the space and thermal requirements of a separate liquid nitrogen return line. Future cable projects will utilize second generation (2G) wire which is expected to become lower in cost but may have different thermal requirements than first generation (1G) BSCCO wire due to the lower critical temperature and to a lesser extent, the lower thermal conductivity of the wire. HTS cable configurations will be studied with a numerical model to assess thermal hydraulic performance with AC and thermal losses; a summary of the results from the analysis will be presented. An analysis of the cable thermal- hydraulic response to over-current faults will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Bubbles on Liquid Nitrogen Breakdown in Plane-Plane Electrode Geometry From 100-250 kPa

Liquid nitrogen (LN(2)) is used as the cryogen and dielectric for many high temperature superconducting, high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric breakdown properties of the LN(2). Experiments were performed using plane-plane electrode geometry where bubbles were introduced into the gap through a pinhole in the ground electrode. Bubbles were generated using one or more kapton heaters producing heater powers up to 30 W. Pressure was varied from 100-250 kPa. Breakdown strength was found to be relatively constant up to a given heater power and pressure at which the breakdown strength drops to a low value depending on the pressure. After the drop the breakdown strength continues to drop gradually at higher heater power. This is particularly illustrated at 100 kPa. After the drop in breakdown strength the breakdown is believed to be due to the formation of a vapor bridge. Also the heater power at which the breakdown strength changes from that of LN(2) to that of gaseous nitrogen increases with increasing pressure. The data can provide design constraints for high temperature superconducting fault current limiters (FCLs) so that the formation of a vapor bridge can be suppressed or avoided.

36 MATERIALS SCIENCE↗

Electrical and Mechanical Characterizations of Nanocomposite Insulation for HTS Systems

As HTS wire technology continues to advance, a critical need has emerged for dielectric materials that can be used in superconducting components such as terminations, fault current limiters, transformers, and motors. To address this need, CTD is developing nanocomposite insulations based on epoxy and benzoxazine chemistries. Depending on part geometry, some processing methods are more efficient than others. For this reason, CTD is investigating both fiber-reinforced and filled resin systems for use in these applications. A thorough set of electrical testing including AC breakdown, breakdown as a function of thickness, and flashover shows promising performance characteristics. In addition, mechanical testing (short beam shear and compression) indicate that these new materials to have as good or better performance than G10.

Walsh, J K↗

Evaluating the Loss of Communications in Distribution Protection Systems using GridLAB-D

Protection in distribution systems is vital for maintaining reliability and ensuring proper power quality is provided to the end-use customer. As more switching devices are deployed on distribution systems, traditional protection schemes are giving way to more advanced, and sometimes centrally coordinated, protection schemes that rely on communications infrastructure. With these communications-dependent systems, the behaviors of the protection with and without the communications infrastructure must be examined. This work has evaluated the impacts of loss of communication in centrally coordinated protection schemes. Two test cases were examined: a sequence of similar faults on a feeder before and after a topology reconfiguration, and a feeder with a photovoltaic (PV) fault current contribution. Both simulations are run in the GridLAB-D™ simulation environment. A simple connectivity model is used to represent communication status. The results reveal that a failure of the communication system can cause significantly different protection behavior. This analysis can be used as a basis for utility engineers to make an informed decision on the impacts of communication losses on their system, as well as evaluating ways to mitigate its impact on the resiliency of the system.

GridLAB-D, Distribution Analysis↗

Topology-Agnostic, Scalable, Self-Healing, and Cost-Aware Protection of Microgrids

Most microgrid protection schemes found in published literature suffer from a lack of generality in that they work well for the assumed topology, including type and placement of sources. Other generic protection schemes tend to be too complicated, too expensive, or both. To overcome these draw- backs, a topology-agnostic, scalable, and cost-aware protection based on fundamental principles that work in the presence of high penetration of inverter-based resources (IBRs) is developed and tested in this paper. Here, the protection system also implements stable automatic reconfiguration of the healthy sections of the system after clearance of fault, thus increasing resilience by self- healing. To achieve this ambitious goal, stable inverter models are developed that operate in unbalanced networks in grid-connected and islanded modes, even with 100% IBRs, share power without conflicting controls, and can ride through faults while limiting fault currents. The scheme is tested for primary and backup protection and reconfiguration on the IEEE 123-node feeder in grid-connected and islanded modes with 15 IBRs connected to the system.

42 ENGINEERING↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

GHOST (Grid Hardware Open Source Testbed) [SWR-18-32]

The software was developed for the purpose of Microgrid Controller Procurement where multiple Microgrid Controller vendors were competing to prove the best performance. Each microgrid controller was connected to Real-Time Simulator (Opal-RT) where the Real-Time model of microgrid was simulated. Microgrid controllers were able to control most of the assets in the model. To be able to fairly compare controller's performance each controller was evaluated using exactly the same model, with the same initial conditions and exactly the same test sequence. The microgrid evaluation test sequence lasted 100 minutes and consist of various grid disturbances to which a microgrid controller must respond. The microgrid and power system will experience multiple types of disturbances while performing dispatch functions. Many functions are tested in grid-connected and islanded modes such as unexpended failures of generators, energy storage trip events, and large load fluctuations. The test sequence focuses on fault scenarios that cause the highest short-circuit fault current contribution; force a swing bus or generator capable of being a swing bus offline; cause the most reconfigurations; and cause conflicting objectives for the microgrid controller. During the test sequence execution multiple datapoints are being recorded and stored. During data postprocessing key performance parameters are extracted allowing quantitative comparison of performance on multiple aspects including: resiliency, fuel utilization, grid interconnection, ancillary services and power quality and eventually after summing all key performance parameters by comparing the overall result. To be able to perform such testing multiple tools had to be developed included in this repository including: - Real time model of microgrid (Urban-Banshee, Remote-smaller model) - Test sequence configuration tools - Test execution real-time scripts - Post processing scripts - Human Machine Interface software

Koralewicz, Przemyslaw↗

Electric Power Infrastructure Reliability and Security (EPIRS) Reseach and Development Initiative

Power systems have become increasingly complex and face unprecedented challenges posed by population growth, climate change, national security issues, foreign energy dependence and an aging power infrastructure. Increased demand combined with increased economic and environmental constraints is forcing state, regional and national power grids to expand supply without the large safety and stability margins in generation and transmission capacity that have been the rule in the past. Deregulation, distributed generation, natural and man-made catastrophes and other causes serve to further challenge and complicate management of the electric power grid. To meet the challenges of the 21st century while also maintaining system reliability, the electric power grid must effectively integrate new and advanced technologies both in the actual equipment for energy conversion, transfer and use, and in the command, control, and communication systems by which effective and efficient operation of the system is orchestrated - in essence, the 'smart grid'. This evolution calls for advances in development, integration, analysis, and deployment approaches that ultimately seek to take into account, every step of the way, the dynamic behavior of the system, capturing critical effects due to interdependencies and interaction. This approach is necessary to better mitigate the risk of blackouts and other disruptions and to improve the flexibility and capacity of the grid. Building on prior Navy and Department of Energy investments in infrastructure and resources for electric power systems research, testing, modeling, and simulation at the Florida State University (FSU) Center for Advanced Power Systems (CAPS), this project has continued an initiative aimed at assuring reliable and secure grid operation through a more complete understanding and characterization of some of the key technologies that will be important in a modern electric system, while also fulfilling an education and outreach mission to provide future energy workforce talent and support the electric system stakeholder community. Building upon and extending portions of that research effort, this project has been focused in the following areas: (1) Building high-fidelity integrated power and controls hardware-in-the-loop research and development testbed capabilities (Figure 1). (2) Distributed Energy Resources Integration - (a) Testing Requirements and Methods for Fault Current Limiters, (b) Contributions to the Development of IEEE 1547.7, (c) Analysis of a STATCOM Application for Wind Resource Integration, (d) Development of a Grid-Interactive Inverter with Energy Storage Elements, (e) Simulation-Assisted Advancement of Microgrid Understanding and Applications; (3) Availability of High-Fidelity Dynamic Simulation Tools for Grid Disturbance Investigations; (4) HTS Material Characterization - (a) AC Loss Studies on High Temperature Superconductors, (b) Local Identification of Current-Limiting Mechanisms in Coated Conductors; (5) Cryogenic Dielectric Research; and (6) Workshops, education, and outreach.

24 POWER TRANSMISSION AND DISTRIBUTION↗