Search NASA⌕ Search

SEARCH · Search NASA

Results for “field emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hypervelocity impact survivability experiments for carbonaceous impactors

We performed a series of hypervelocity impact experiments using carbon-bearing impactors (diamond, graphite, fullerenes, phthalic acid crystals, and Murchison meteorite) into Al plate at velocities between 4.2 and 6.1 km/s. These tests were made to do the following: (1) determine the survivability of carbon forms and organize molecules in low hypervelocity impact; (2) characterize carbonaceous impactor residues; and (3) determine whether or not fullerenes could form from carbonaceous impactors, under our experimental conditions, or survive as impactors. An analytical protocol of field emission SEM imagery, SEM-EDX, laser Raman spectroscopy, single and 2-stage laser mass spectrometry, and laser induced fluorescence (LIF) found the following: (1) diamonds did not survive impact at 4.8 km/s, but were transformed into various forms of disordered graphite; (2) intact, well-ordered graphite impactors did survive impact at 5.9 km/sec, but were only found in the crater bottom centers; the degree of impact-induced disorder in the graphite increases outward (walls, rims, ejecta); (3) phthalic acid crystals were destroyed on impact (at 4.2 km/s, although a large proportion of phthalic acid molecules did survive impact); (4) fullerenes did not form as products of carbonaceous impactors (5.9 - 6.1 km/s, fullerene impactor molecules mostly survived impact at 5.9 km/s; and (5) two Murchison meteorite samples (launched at 4.8 and 5.9 km/s) show preservation of some higher mass polycyclic aromatic hydrocarbons (PAHs) compared with the non-impacted sample. Each impactor type shows unique impactor residue morphologies produced at a given impact velocity. An expanded methodology is presented to announce relatively new analytical techniques together with innovative modifications to other methods that can be used to characterize small impact residues in LDEF craters, in addition to other acquired extraterrestrial samples.

Bunch, T. E.↗

Electromagnetic compatibility characterization of a BAe Stirling-cycle cryocooler for space application

This paper describes the electromagnetic compatibility (EMC) measurements of an 80-K Stirling-cycle cooler. The measurements, performed in the JPL EMC test facility, include dc magnetic field characterization, radiated magnetic and electric field emissions, and conducted emissions on the internal lines between the cooler electronics and the cooler. The measurements conform to both the MILSTD-461C specifications as well as to the specifications for the NASA Earth Observing System.

Johnson, Dean L.↗

Preliminary AEM study of the microstructure and composition of metal particles in ordinary chondrites

The purpose of this study is to examine the microstructure and composition of the metal particles in ordinary chondrites using analytical electron microscopy (AEM) techniques. Since the phases produced within the metal particles are very fine, the application of various AEM techniques for structural and chemical characterization is critical. However, thin specimen preparation for AEM study has proven very difficult because of the matrix silicate which is present. This is the first AEM study of the metal particles in chondrites. A type 6 chondrite, Saint Severin (LL6), was selected for examination because the metal phases have been reheated into the single phase taenite region (greater than 700 C), and cooled slowly to lower temperatures. A combination of electron optical instruments was employed including a field emission gun (FEG) JEOL 840F high resolution scanning electron microscope (HRSEM), a JEOL 6300F FEG-HRSEM, a Philips 400T AEM, and a JEOL 733 electron probe microanalyzer (EPMA).

Yang, C. W.↗

Image and compositional characteristics of the LDEF Big Guy impact crater

A 5.2 mm crater in Al-metal represents the largest found on LDEF. We have examined this crater by field emission scanning electron microscopy (FESEM), energy dispersive spectroscopy (EDS) and time-of-flight/secondary ion mass spectroscopy (TOF-SIMS) in order to determine if there is any evidence of impactor residue. Droplet and dome-shaped columns, along with flow features, are evidence of melting. EDS from the crater cavity and rim show Mg, C, O and variable amounts of Si, in addition to Al. No evidence for a chondritic impactor was found, and it hypothesized that the crater may be the result of impact with space debris.

Bunch, T. E.↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

The Wavelength-Dispersive Spectrometer and Its Proposed Use in the Analytical Electron Microscope

The Analytical Electron Microscope (AEM) equipped with a wavelength-dispersive spectrometer (WDS) should have the ability to resolve peaks which normally overlap in the spectra from an energy-dispersive spectrometer (EDS). With a WDS it should also be possible to measure lower concentrations of elements in thin foils due to the increased peak-to-background ratio compared with EDS. The WDS will measure X-ray from the light elements (4 less than Z less than 1O) more effectively. This paper addresses the possibility of interfacing a compact WDS with a focussing circle of approximately 4 cm to a modem AEM with a high-brightness (field emission) source of electrons.

Goldstein, Joseph I.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Comments on SEE: Comparative Advantages and and Experimental Consequences

The Satellite Energy Exchange experiment measures the periodic, near-miss encounters between a sheppard satellite and a small test body (satellite) in approximately the same orbit about a primary. Several important experimental requirements have been chosen to enhance capabilities: (a) The satellite be flown in a sun-synchronous orbit at an altitude of about 1350 Km, (b) Passive temperature system stabilized by spacecraft axial rotation with sunshade baffles at the end of the spacecraft, (c) Test bodies with different material composition be available for experiments, (d) The containment spacecraft fly about the sheppard mass in a zero-g environment whereas the test bodies, experience average zero-g environment over an orbital period, (e) Primary attitude and station-keeping uses magnetic field alignment plus micro-Newton thrusters such as Field Emission Electric Propulsion, and (f) Very low power (nW) laser tracking systems minimize impulse delivered to test bodies. With the above conditions, SEE has the capabilities: (1) Long duration (several years life-time) flight experiment (2) Long-term, active (with historical time record), self-calibration of satellite mass distribution (capsule geodesy) over lifetime of the spacecraft. (3) Novel passive thermal stabilization systems designed to attain cryogenic temperatures around 78K. (4) Novel spacecraft stabilization systems. (5) Ability to measure G to 1 part in 10(exp 6-7) depending on ultimate duration of experiment. (6) Ability to place limits on both temporal and spacial variations on G. (7) Ability to set experimental limits on the Post Newtonian parameters (PPN) alpha(2) and zeta(2). (8) Ability to measure (or place limits on) the non Einsteinian eccentricity of the Earth-Sun system (and the parameter alpha(1)) for long duration flight. (9) Ability to measure Delta((dot)-G)/G to 1 part in 10(exp 12-13). The MiniSTEP, competes in a limited way with Project SEE. It is designed to improve the measurement of the equivalence principle by seven orders of magnitude using active, low temperature (1.8 K) cooling for SQUID based, differential superconducting circuits. The experiment consists of a small cylinder concentrically located within a larger cylinder at its null gravitational point. The satellite is operated in zero-g mode using four differential accelerometers consisting to two test bodies of different material composition. The SQUIDS are needed to measure test body motion to precisions of 10(exp -18) over a four orbit period. The entire satellite moves in a very precise zero-g mode since the accelerometers are rigidly attached to the satellite. This limits the experiment to an approximately six month due to limitations on helium storage used in cryogenic cooling and thrust control to maintain the zero-g operation.

Smalley, Larry L.↗

Alteration Products and Secondary Minerals in Martian Meteorite Allan Hills 84001

The martian meteorites contain alteration products and secondary minerals that are a critical part of understanding their near-surface histories on both Mars and Earth. In some martian meteorites, suspected martian preterrestrial alteration products can be distinguished from terrestrial weathering effects Using scanning electron microscopy (SEM), field emission SEM (FE-SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray analysis (EDS), we are studying natural fracture surfaces of ALH 84001 chips, including samples from both the interior and the exterior of the meteorite. Exterior samples include fusion crust surfaces, which are important in determining the extent of terrestrial weathering of meteorites. The focus of this study is weathering features and secondary minerals other than the distinctive carbonate globules that continue to be studied by many researchers.

Wentworth, S. J.↗

Physical and Chemical Characterization of Particles in the Upper Troposphere and Lower Stratosphere: Microanalysis of Aerosol Impactor Samples

Herein is reported activities to support the characterization of the aerosol in the upper troposphere (UT) and lower stratosphere (LS) collected during the Airborne Southern Hemisphere Ozone Experiment/Measurements for Assessing the Effects of Stratospheric Aircraft (ASHOE/MAESA) missions in 1994. Through a companion proposal, another group was to measure the size distribution of aerosols in the 0.008 to 2 micrometer diameter range and to collect for us impactor samples of particles larger than about 0.02 gm. In the first year, we conducted laboratory studies related to particulate deposition patterns on our collection substrates, and have performed the analysis of many ASHOE/MAESA aerosol samples from 1994 using analytical electron microscopy (AEM). We have been building an "aerosol climatology" with these data that documents the types and relative abundances of particles observed at different latitudes and altitudes. The second year (and non-funded extension periods) saw continued analyses of impactor aerosol samples, including more ASHOE/MAESA samples, some northern hemisphere samples from the NASA Stratospheric Photochemistry Aerosols and Dynamics Expedition (SPADE) program for comparison, and a few aerosol samples from the NASA Stratospheric TRacers of Atmospheric Transport (STRAT) program. A high-resolution field emission microscope was used for the analysis and re-analysis of a number of samples to determine if this instrument was superior in performance to our conventional electron microscope. In addition, some basic laboratory studies were conducted to determine the minimum detectable and analyzable particle size for different types of aerosols. In all, 61 aerosol samples were analyzed, with a total of over 30,000 individual particle analyses. In all analyzed samples, sulfate particles comprised the major aerosol number fraction. It must be stressed that particles composed of more than one species, for example sulfate and organic carbon, were classified according to the major fraction. Thus, many of the particles classified as sulfate may have contained significant mass fractions of carbonaceous or other material. These particles for the most part did not show two physical phases, however. Nonsulfate particles were classified according to the physical and chemical characteristics of each particle, and were grouped into the major nonsulfate particle classes, including C-rich, crustal, metallic, and salts. Our UT and LS sample analyses indicate a maximum for crustal and C-rich particle abundance in the Northern Hemisphere upper troposphere, and a salt particle maximum in the Southern Hemisphere upper troposphere. Metallic particles are clearly more prevalent in the troposphere than in the stratosphere, but interhemispheric differences appear small.

Sheridan, Patrick J.↗

Evidence for Microfossils in Ancient Rocks and Meteorites

The McKay et all. detection of chemical biomarkers and possible microfossils in an ancient meteorite from Mars (ALH84001) stimulated research in several areas of importance to the newly emerging field of Astrobiology. Their report resulted in a search for additional evidence of microfossils in ancient terrestrial rocks and meteorites. These studies of ancient rocks and meteorites were conducted independently (and later collaboratively) in the United States and Russia using the SEM, Environmental Scanning Electron Microscope (ESEM), and Field Emission Scanning Electron Microscope (FESEM). We have encountered in-situ in freshly broken carbonaceous chondrites a large number of complex microstructures that appear to be lithified microbial forms. The meteoritic microstructures have characteristics similar to the lithified remains of filamentous cyanobacteria and bacterial microfossils we have found in ancient phosphorites, ancient graphites and oil shales. Energy Dispersive Spectroscopy (EDS) and Link microprobe analysis shows the possible microfossils have a distribution of chemical elements characteristic of the meteorite rock matrix, although many exhibit a superimposed carbon enhancement. We have concluded that the mineralized bodies encountered embedded in the rock matrix of freshly fractured meteoritic surfaces can not be dismissed as recent surface contaminants. Many of the forms found in-situ in the Murchison, Efremovka, and Orgueil carbonaceous meteorites are strikingly similar to microfossils of coccoid bacteria, cyanobacteria and fungi such as we have found in the Cambrian phosphorites of Khubsugul, Mongolia and high carbon Phanerozoic and Precambrian rocks of the Siberian and Russian Platforms.

Hoover, Richard B.↗

Analyses of Contaminated Solar Array Handrail Samples Retrieved from Mir

In January 1998 during, the STS-89 mission, an eight section Russian solar array panel was retrieved after more than ten years exposure to the orbital space environment on the Russian space station Mir. Two darkened handrail samples from the Russian solar array have been evaluated for contamination: a section of a white paint covered rigid handrail and a section of woven fabric over-wrapped around a flexible handhold. The handrail samples were evaluated using optical microscopy (OM), field emission scanning electron microscopy (FESEM) and energy dispersive spectroscopy (EDS). Optical properties were also obtained. Microscopy has shown the discolored areas to have thick layers of contaminant that has crazed and spalled off in regions. Energy dispersive spectroscopy revealed that the brown contaminant is composed of oxidized silicon. No silicon was present on the unexposed fabric over-wrap, and very small amounts were present in the white paint. Therefore, the contaminant layer on both samples is attributed to silicone contamination from other spacecraft materials that have been oxidized by atomic oxygen while in orbit. A significant source of the silicone contamination appears to be from the solar array itself.

deGroh, Kim K.↗

Characterization of In-Situ BN Interface Formed by Nitridation of Nextel 312

Treatment of Nextel (TM) 312 in a reactive environment has been used as a low cost approach to the formation of BN on the fiber surface. Although the BN enriched surface region is extremely thin (less than 40 run), it is effective in providing debonding and composite behavior. Variation in mechanical behavior of Nextel (TM) 312/BN/Blackglas (TM) composites has been noted among panels fabricated with AF-10 cloth treated in different nitridation runs, Understanding this variation became the rationale for undertaking a detailed characterization of the nitrided fiber using field emission scanning electron microscopy, low voltage energy dispersive x-ray and Auger electron spectroscopy. Chemical composition and surface morphology are discussed in relation to observed mechanical behavior of NeXtel (TM) 312/Blackglas (TM) composites tested in bending.

Hurwitz, Fances I.↗

Theoretical Study of Response of InGaAs Metal-Semiconductor-Metal Photodetectors

We present a theoretical investigation of the response of metal-semiconductor-metal (MSM) photodetectors made of InGaAs lattice-matched to InP using a two-dimensional drift-diffusion model with a thermionic-field emission boundary condition for the heterojunctions. The effect of including a top InAlAs layer to increase the effective barrier height of the metal fingers on the InGaAs active layer is thoroughly examined and found to limit the collection of the photocurrent signal due to the electron and hole barriers that it forms with InGaAs. Due to the thickness and height of the InAlAs barrier layer in existing designs, the tunneling current obtained from the model is found to be negligibly small to significantly affect the output signal current. In an attempt to obtain a better response, different design structures including one where a quasi-Schottky contact is utilized are studied and their speed of response, breakdown voltage, and dark current are compared to that of the usual InGaAs device.

Salem, Ali F.↗

Theoretical Study of the Effect of an AlGaAs Double Heterostructure on Metal-Semiconductor-Metal Photodetector Performance

The impulse and square-wave input response of different GaAs metal-semiconductor-metal photodetector (MSM) designs are theoretically examined using a two dimensional drift- diffusion numerical calculation with a thermionic-field emission boundary condition model for the heterojunctions. The rise time and the fall time of the output signal current are calculated for a simple GaAs, epitaxially grown, MSM device as well as for various double-heterostructure barrier devices. The double heterostructure devices consist of an AlGaAs layer sandwiched between the top GaAs active, absorption layer and the bottom GaAs substrate. The effect of the depth of the AlGaAs layer on the speed and responsivity of the MSM devices is examined. It is found that there is an optimal depth, at fixed applied bias, of the AlGaAs layer within the structure that provides maximum responsivity at minimal compromise in speed.

Salem, Ali F.↗

Black Carbon (Soot) Aerosol in the Lower Stratosphere and Upper Troposphere

We have used two approaches to measure BCA in the stratosphere. The first method consists of collecting aerosols by impaction on quartz rods, upon which are mounted strips of polystyrene filter material. Each 25 mm by 0.5 mm filter strip is alternately masked and exposed in 5 mm long sections. After sampling, the optical density of the exposed sections is measured and compared with the optical density of the masked (unexposed) sections. The filter strip is a Lambertian collector, the scattering property of which is not affected by the deposition of liquid sulfuric acid droplets which dominate the stratospheric aerosol. Hence, all attenuation greater in the exposed than in the non-exposed sections is due to absorption by BCA or rare opaque materials such as meteoritic iron. In a second approach we expose carbon-coated gold or palladium wires to air outside the aircraft boundary layer [Farlow et al., 1979; Pueschel et al., 1989]. With a field emission scanning electron microscope we are able to characterize BCA particles in addition to the dominant sulfuric acid droplets. Typically, soot is comprised of 20 nm diameter spheres linked together as branching chains or loosely packed aggregates (Figure 1a). The microscope has a lateral image resolution of 1.5 nm and can clearly resolve individual spheres making up BCA aggregates. Their morphology is uniquely different from that of the liquid sulfuric acid-water aerosol (Figure 1b). We approximate the size of each BCA particle by that of a sphere of equivalent volume and fit a lognormal size distribution to both the BCA and H2SO4/H2O aerosols. Both sampler types have been mounted on NASA's ER-2 high-altitude research aircraft (altitude ceiling of 70,000 feet), and on NASA's DC-8 (40,000 feet ceiling) aircraft to sample aerosols from a significant portion of the atmosphere.

Pueschel, R. F.↗

Alteration of Rock Fragments from Columbia River Basalt Microcosms

During an earlier study, microorganisms were grown microcosms consisting of sterilized chips of Columbia River Basalt (CRB) and natural CRB ground water with its natural microflora; environmental conditions simulated a deep subsurface, anaerobic, dark environment. Subsequent scanning and transmission electron microscope (SEM and TEM) studies revealed the presence of several types of bacteria and biofilm, some of which were mineralized. Some of these biological features are very similar to possible biogenic features found in two meteorites from Mars, ALH84001 (found in Antarctica) and Nakhla (observed to fall in Egypt). Both ALH84001 and Nakhla contain traces of low-temperature aqueous alteration of silicates, oxides, and sulfides. The goals of this study are to use high-resolution field-emission SEM (FE-SEM) to examine the CRB samples for evidence of alteration features similar to those in the martian meteorites, to determine the extent of alteration during the CRB microcosm experiments, and to determine whether effects of biological activity can be distinguished from inorganic effects.

Wentworth, Susan J.↗

Carbon Nanotube Composites: Strongest Engineering Material Ever?

The primary goal of the carbon nanotube project at Johnson Space Center (JSC) is to fabricate structural materials with a much higher strength-to-weight ratio than any engineered material today, Single-wall nanotubes present extraordinary mechanical properties along with new challenges for materials processing. Our project includes nanotube production, characterization, purification, and incorporation into applications studies. Now is the time to move from studying individual nanotubes to applications work. Current research at JSC focuses on structural polymeric materials to attempt to lower the weight of spacecraft necessary for interplanetary missions. These nanoscale fibers present unique new challenges to composites engineers. Preliminary studies show good nanotube dispersion and wetting by the epoxy materials. Results of tensile strength tests will also be reported. Other applications of nanotubes are also of interest for energy storage, gas storage, nanoelectronics, field emission, and biomedical uses.

Mayeaux, Brian↗