Search NASA⌕ Search

SEARCH · Search NASA

Results for “fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

AGC 4 Graphite Specimen Postirradiation Characterization Plan

This characterization plan describes the thermal, physical, and mechanical measurement techniques that will be used to characterize graphite samples being tested in the fourth Advanced Graphite Creep experiment (AGC-4). Instruments, fixtures, and methods are currently in place for both pre and postirradiation material property measurements of bulk density, thermal diffusivity, coefficient of thermal expansion, elastic modulus, and electrical resistivity. Postirradiation testing procedures used to characterize the samples are described and discussed in the plan. Where they exist, American Society for Testing and Materials (ASTM) International testing standards will apply to the tests. Any departure from ASTM International testing standards or the approved laboratory procedures are documented within this characterization plan. Deviations that occur during testing will be documented in data reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Ion beam mill etch depth monitoring with nanometer-scale resolution

A method for measuring conductance of a material real-time during etching/milling includes providing a fixture having a socket for receiving the material. The socket is attached to a printed circuit board (PCB) mounted on one side of a plate that has at least one opening for providing ion beam access to the material sample. Conductive probes extend from the other side of the PCB to contact and span a target area of the material. A measurement circuit in electrical communication with the probes measures the voltage produced when a current is applied across the material sample to measure changes in electrical properties of the sample over time.

Cybart, Shane A.↗

Lanthanum Strontium Cobaltite-Alumina Fiber Composite Contact Material for Solid Oxide Fuel Cells

Short alumina fibers were added to LSCo contact material to enhance the contact strength and improve thermal cycle stability. Alumina fiber from 2.5 v% to 20 v% were mixed with LSCo and sintered at elevated temperatures. Sintering study showed retardation in densification of LSCo matrix with increasing alumina content. Sintered bulk strength exhibited similar behavior where strength greatly reduced at high alumina v%. Coefficient of thermal expansion showed consistent results with prediction from rule of mixture. Contact strength using anode supported YSZ bilayer coupons improved greatly with the presence of small amount (2.5-5 v%) alumina fibers and no substantial reduction after 10 deep thermal cycles. Candidate LSCo-Al2O3 contact materials was validated in a generic stack test fixture for 1000h at 800oC followed by 10 thermal cycles. Results of impedance analysis showed substantial improvement in thermal cycle stability as compared to LSCo parent materials.

SOFC cathode, strength, LSCo, alumina↗

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

Evaluating the Durability of Balance of Systems Components Using C-AST

The testing of branch- and cable-connectors, and fuses in C-AST is introduced. A significant effect was observed when mechanical actuation was introduced to the benchtop prototype testing. Therefore, this presentation emphasizes the mechanical test fixture, data acquisition system, failure analysis of the components used in specimen assemblies, and the validation of the results relative to field failed samples.

components↗

LED Troffer Retrofit Lighting and Controls Best Practices

This document provides guidance for retrofitting existing fluorescent troffer fixtures with LEDs, as well as information about lighting controls. It outlines the pros and cons of three different retrofit options: Tubular LEDs, Retrofit Kits, and Luminaires.

lighting, LED, troffer, retrofit, lighting control↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Planar mechanical actuation system for adjustable luminaires

A mechanical actuation system for a light fixture that allows for translation of an array of optics relative to an array of light sources in a defined plane. The system can prevent undesired movement such as rotation or out-of-plane motion. A simple and intuitive user interface enables a user to point a resulting light beam in a desired direction without requiring an understanding of the internal mechanical system. The user interface may include a manually manipulated touch point such as a joystick, knob, or other interface.

Gladden, Christopher↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Target Multiwire for the Fermilab Booster Neutrino Beamline

The Booster Neutrino Beamline experiment re-quested a new secondary electron emission multiwire profile monitor installation. The device had to be durable in high radiation conditions and mounted within a large 10-foot airtight steel fixture for installation near the beam target. Previous iterations of multiwire suffered radiation damage to both the connectors and wires. To ensure accurate horizontal and vertical beam profile measurements, an updated design was pro-posed, designed, and constructed. The new BNB multiwire utilizes 3 mil diameter gold-plated tungsten sense wires soldered to vertical and horizontal Alumi-na-96 ceramic planes, 50 wires per plane. Radiation hard Kapton insulated 30-gauge wires carry the output signals. Profiles are readout through charge integrator scanner electronics. This paper will detail the design and functionality of the BNB target multiwire and present relevant beam profile data.

43 PARTICLE ACCELERATORS↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Wind Turbine Blade Repurposing and Recycling: Coupling Repurposing Methods with 3D Printing Technology

Fiber-reinforced thermoplastic composites continue to be implemented in several marketsbecause of their strength capacity and light weight. Especially in the wind industry, wind bladesare made of this material which makes them ideal for wind energy generation, but bladesbecome a problem at end-of-life. Because recycling thermoplastic composites technologiesare still not cost and environmentally effective, research in this space is needed. This paperpresents a case study for coupling repurposed wind turbine blades and 3D printing technology.The purpose is to remanufacture decommissioned wind blades into bus stop roof and seatingsections to then use recycled glass fiber from a decommissioned wind turbine blade to 3Dprint structural and/or fixtures needed in the assembly. We provide an overview of the designprocess, and the development process steps in repurposing and 3D printing the material,delving into key parameters required for a successful implementation.

Henao, Yulizza↗