Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal planes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

8-9 and 14-15 Micron Two-Color 640x486 GaAs/AlGaAs Quantum Well Infrared Photodetector (QWIP) Focal Plane Array Camera

An optimized long-wavelength two-color Quantum Well Infrared Photodetector (QWIP) device structure has been designed. This device structure was grown on a three inch semi-insulating GaAs substrate by molecular beam epitaxy (MBE). This wafer was processed into several 640x486 format monolithically integrated 8-9 and 14-15 micron two color (or dual wavelength) QWIP focal plane arrays (FPAs). These FPAs were then hybridized to 640x486 silicon CMOS readout multiplexers. A thinned (i.e., substrate removed) FPA hybrid was integrated into a liquid helium cooled dewar to perform electrical and optical characterization and to demonstrate simultaneous two-color imagery. The 8-9 micron detectors in the FPA have shown background limited performance (BLIP) at 70 K operating temperature, at 300 K background with f/2 cold stop. The 14-15 micron detectors of the FPA have reached BLIP at 40 K operating temperature at the same background conditions. In this presentation we discuss the performance of this long-wavelength dualband QWIP FPA in quantum efficiency, detectivity, noise equivalent temperature difference (NEAT), uniformity, and operability.

Gunapala, S. D.↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗

Assembly Development for the Simons Observatory Focal Plane Readout Module

The Simons Observatory (SO) is a suite of instruments sensitive to temperature and polarization of the cosmic microwave background (CMB) to be located at Cerro Toco in the Atacama Desert in Chile. Five telescopes, one large aperture telescope and four small aperture telescopes, will host roughly 70,000 highly multiplexed transition edge sensor (TES) detectors operated at 100 mK. Each SO focal plane module (UFM) couples 1,764 TESes to microwave resonators in a microwave multiplexing (μMux) readout circuit. Before detector integration, the100 mKμMux components are packaged into multiplexing modules (UMMs), which are independently validated to ensure they meet SO performance specifications. Here we present the assembly developments of these UMM readout packages for mid frequency (90/150 GHz) and ultra high frequency (220/280 GHz) UFMs.

Aamir M. Ali↗

Optimization of Lyot Coronagrah focal plane masks for improved low-order wavefront sensing

The WFIRST Coronagraph uses a Low-Order Wavefront Sensing and Control (LOWFS/C) subsystem to stabilize the stellar wavefront. This is true for the Hybrid Lyot Coronagraph (HLC), the Shaped Pupil Coronagraph (SPC) spectrograph, and the SPC wide field of view modes. For the SPC spectrograph, we have found via modeling and simulations that a focal plane mask (FPM) with an elliptical phase dimple can reduce the LOWFS errors significantly compared to the conventional, circular phase dimple. For HLC designs, we concurrently optimized the FPM parameters and deformable mirror shapes using our open-source software toolbox, the Fast Linearized Coronagraph Optimizer (FALCO). This process resulted in new FPMs with non-uniform central-area phase modulation. We have found in numerical simulations that such FPMs still provide sufficient LOWFS performance. In this paper, we will present the LOWFS performance for several new HLC and SPC FPM designs.

Riggs, A.J. Eldorado↗

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared↗

The Focal Plane Crystal Spectrometer for the HEAO-B satellite

The very low flux from even the brightest (non-solar) X-ray source has discouraged the use of instruments with high spectral resolution because of their inevitably low sensitivity. Mission B of the High Energy Astronomy Observatory will provide the first opportunity for moderate and high resolution spectral studies of celestial X-ray sources with high sensitivity. The Focal Plane Crystal Spectrometer (FPCS) described here is the instrument with the highest spectral resolution. It is designed to allow detailed spectral studies of both point and extended celestial sources in the energy range 0.2-3.3 keV with resolutions of 50 to 1000.

Donaghy, J. F.↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗

Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results

The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.

Goldberg, A.↗

Test results of Spacelab 2 infrared telescope focal plane

The small helium cooled infrared telescope for Spacelab 2 is designed for sensitive mapping of extended, low-surface-brightness celestial sources as well as highly sensitive investigations of the shuttle contamination environment (FPA) for this mission is described as well as the design for a thermally isolated, self-heated J-FET transimpedance amplifier. This amplifier is Johnson noise limited for feedback resistances from less than 10 to the 8th power Omega to greater than 2 x 10 to the 10th power Omega at T = 4.2K. Work on the focal plane array is complete. Performance testing for qualification of the flight hardware is discussed, and results are presented. All infrared data channels are measured to be background limited by the expected level of zodiacal emission.

Young, E. T.↗

MLA instruments and SWIR focal-plane technology

It is pointed out that next-generation sensors for earth observation will utilize Multispectral Linear Array (MLA) technology wherein linear detector arrays will scan the earth in pushbroom fashion. MLA instruments will permit a dramatic increase in detector dwell time, which can be utilized to improve spatial, spectral, and radiometric resolution. In connection with the considered applications for MLA sensors, the employed detector arrays should cover the visible, near-infrared, and shortwave infrared (SWIR) spectral bands. The present paper is mainly concerned with the development of mercury-cadmium-telluride focal-plane arrays for the SWIR spectral regime (1-2.5 microns). Attention is given to the requirements, design details regarding the detector array, the employed multiplexer technique, the hybrid concept, packaging, and the program status.

Brown, F. G.↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Detectors and Focal Plane Modules for Weather Instruments

Weather satellite instruments require detectors with a variety of wavelengths ranging from the visible to VLWIR. The Cross-track infrared Sounder (CrIS) is a Polar Orbiting interferometric sensor that measures earth radiances at high spectral resolution, using the data to provide pressure, temperature and moisture profiles of the atmosphere. The pressure, temperature and moisture sounding data are used in weather prediction models that track storms, predict levels of precipitation etc. The CrIS instrument contains SWIR (lambda(sub c) (is) approximately 5 micrometers at 98 K), MWIR (lambda(sub c) (is) approximately 9 micrometers at 98 K) and LWIRs (lambda(sub c) (is) approximately 15.4 m at 81 K) bands in three Focal Plane Array Assemblies (FPAAs). CrIS detectors are 850 micrometers diameter detectors with each FPAA consisting of nine photovoltaic detectors arranged in a 3 x 3 pattern. Molecular beam epitaxy (MBE)-grown Hg1-xCdxTe material are used for the detectors fabricated in a modified Double Layer Planar Heterostructure (DLPH) architecture. Each detector has an accompanying cold preamplifier. SWIR and MWIR FPAAs operate at 98 K and the LWIR FPAA at 81 K, permitting the use of passive radiators to cool the detectors. D* requirements at peak 14.01 micrometers wavelength are greater than 5.0E+10 Jones for LWIR, greater than 7.5E+10 Jones at 8.26 micrometers for MWIR and greater than 3.0E+11 Jones at peak 4.64 micrometers wavelength for SWIR. All FPAAs exceeded the D* requirements. Measured mean values for the nine photodiodes in each of the LWIR, MWIR and SWIR FPAAs are D* = 5.3 x 10(exp 10) cm-Hz1/2/W at 14.0 micrometers, 9.6 x 10(exp 10) cm-Hz1/2/W at 8.0 micrometers and 3.4 x 10(exp 11) cm-Hz1/2/W at 4.64 micrometers.

satellite instruments↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

Study of the polarization dependence of the photoelectric effect in the soft X-ray band - A focal plane photoelectric stellar X-ray polarimeter for the Spectrum-X-Gamma mission

An experimental study of the polarization dependence of the photoelectric effect in cesium iodide in the soft X-ray band was started (Heckler et al., 1989). At a grazing angle of 10 degrees and a photon energy of 2.6 keV, it is found that the photoelectric yield from a thin layer of evaporated cesium iodide varies by 12.4 percent as the polarization vector of the incident X-ray beam is rotated about the line-of-sight. The rotation angle corresponding to the maximum photoyield is displaced by 16 degrees from the normal to the photocathode. This modulation and phase shift are in good agreement with the results recently reported by Fraser, et al. (1989) It is shown that a focal plane stellar X-ray polarimeter based on this photoelectric effect will be substantially more efficient than convential X-ray polarimeters such as those based on either Bragg reflection or scattering from low atomic number targets.

Heckler, A.↗

Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development

The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe approx.70% of the sky. A variable-delay polarization modulator provides modulation of the polarization at approx.10Hz to suppress the 1/f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that spans both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation. CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single-mode transmission on the chip and prevents stray light from coupling to the detectors.

polarized signature of inflation↗

T2SL Focal Planes for Compact Remote Sensing Instruments

In this presentation, we will report our recent efforts in achieving high performance in Antimonides type-II superlattice (T2SL) based infrared photodetectors using the barrier infrared detector (BIRD) architecture. The initial BIRD devices (such as the nBn and the XBn) used either InAs absorber grown on InAs substrate, or lattice-matched InAsSb alloy grown on GaSb substrate, with cutoff wavelengths of ~3.2μm and ~4μm, respectively. While these detectors could operate at much higher temperatures than existing MWIR detectors based on InSb, their spectral responses do not cover the full (3 – 5.5μm) MWIR atmospheric transmission window. The T2SL BIRD devices not only covers the full MWIR atmospheric transmission window, but the full LWIR atmospheric transmission window and beyond. The LWIR detectors based on the BIRD architecture has also demonstrated significant operating temperature advantages over those based on traditional p-n junction designs. Two 6U SmalSat missions CIRAS (Cubesat Infrared Atmospheric Sounder) and HyTI (Hyperspectral Thermal Imager) are based on JPL’s T2SL BIRD focal plane arrays (FPAs). Based on III-V compound semiconductors, the BIRD FPAs offer a breakthrough solution for the realization of low cost (high yield), high-performance FPAs with excellent uniformity and pixel-to-pixel operability.

Ghuman, Parminder↗

Antimonides T2SL Mid-Wave and Long-Wave Infrared Focal Plane Arrays for Earth Remote Sensing Applications

In this presentation, we will report our recent efforts in achieving high performance in Antimonides type-II superlattice (T2SL) based infrared photodetectors using the barrier infrared detector (BIRD) architecture. The initial BIRD devices (such as the nBn and the XBn) used either InAs absorber grown on InAs substrate, or lattice-matched InAsSb alloy grown on GaSb substrate, with cutoff wavelengths of ~3.2μm and ~4μm, respectively. While these detectors could operate at much higher temperatures than existing MWIR detectors based on InSb, their spectral responses do not cover the full (3 – 5.5μm) MWIR atmospheric transmission window. The T2SL BIRD devices not only covers the full MWIR atmospheric transmission window, but the full LWIR atmospheric transmission window and beyond. The LWIR detectors based on the BIRD architecture has also demonstrated significant operating temperature advantages over those based on traditional p-n junction designs. Two 6U SmalSat missions CIRAS (Cubesat Infrared Atmospheric Sounder) and HyTI (Hyperspectral Thermal Imager) are based on JPL’s T2SL BIRD focal plane arrays (FPAs). Based on III-V compound semiconductors, the BIRD FPAs offer a breakthrough solution for the realization of low cost (high yield), high-performance FPAs with excellent uniformity and pixel-to-pixel operability.

Ghuman, Parminder↗