Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Measuring key Sm isotope ratios in irradiated UO 2 for use in plutonium discrimination nuclear forensics

As part of an experimental validation of a nuclear forensics methodology for Pu source reactor-type discrimination, destructive analysis has been performed here on two irradiated UO 2 pellets with different irradiation histories. Analysis has focused on measuring key Sm fission product isotope ratios used in a previously published maximum likelihood methodology to determine the most likely irradiation history of the pellets. A total of 21 Sm isotope ratios were measured within the irradiated pellets, and generally agreed within 20% of the irradiations as simulated using the Monte Carlo Radiation Transport and material depletion code, MCNP6. Results indicate the chosen approach can accurately measure the isotope ratios within 5% experimental error.

07 ISOTOPE AND RADIATION SOURCES↗

A highly-enriched 244 Pu reference material for nuclear safeguards and nuclear forensics measurements

A highly-enriched 244 Pu isotope dilution reference material has been prepared and characterized for metrologically traceable measurements of very small quantities of plutonium. The amount of plutonium in samples associated with nuclear safeguards and nuclear forensic measurements can be significantly less than 1 ng. Accordingly, the ability to quantify the amount and isotopic composition of plutonium from a single mass-spectrometric analysis is particularly desirable. The highly-enriched 244 Pu reference material, described here, will minimize the magnitude of spike corrections necessary to obtain accurate information on plutonium isotopic composition from isotope dilution measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Exploring the use of thorium isotope compositions and concentrations as nuclear forensic signatures for uranium ore concentrates

This interlaboratory study measured thorium concentrations and isotope compositions in uranium ore concentrates from different geographical locations to examine whether thorium impurities may be useful forensic signatures for uranium ore concentrates found out of regulatory control. Measured 230 Th/ 232 Th in fifteen uranium ore concentrates record over three orders of magnitude of compositional variation. Results demonstrate that 230 Th/ 232 Th used in combination with U/Th ratios resulted in a unique signature for individual uranium ore concentrates from different processing locations. Data presented here suggest potential for 230 Th/ 232 Th and U/Th to be used as comparative signatures to investigate the provenance of seized uranium ore concentrates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation of protactinium from uranium-niobium alloys for 231 Pa– 235 U radiochronometry in nuclear forensic investigations

The isolation and purification of protactinium from uranium materials is essential for 231 Pa– 235 U radiochronometry, but separating Pa from uranium-niobium alloys, a common material in the nuclear fuel cycle, is challenging due to the chemical similarity of Pa and Nb. Here, in this work, we present three resin chromatography separation techniques for isolating Pa from U and Nb which were independently developed by three different laboratories through ad hoc adaptations of standard operating procedures. Our results underscore the need for and value of purification methods suitable for a diversity of uranium-based materials to ensure the operational readiness of nuclear forensics laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An introduction to the significance of sample size in particle analyses for nuclear forensics and radiological investigations

Particulate isotopic analysis in nuclear forensics has developed rapidly during the past two decades due to technical advances in determining the isotopic composition of individual particles. This paper introduces basic statistical concepts that can be applied by analysts to understand the importance of statistical adequacy when interpretating particle data. While these basic statistical methods provide a useful point-of-entry to particle data analysis, more sophisticated statistical and modeling approaches are needed to extract maximal information from such datasets in the future.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear forensic analysis on uranium ore concentrates: A multi-laboratory intercomparison study

A collaboration between the United States and Japan performed nuclear forensic analyses on a set of 7 uranium ore concentrate (UOC) samples with known origins to improve methodologies and best practices in the field. Overall, good agreement between the 4 participating laboratories was achieved for uranium assay, uranium isotope composition, strontium isotope composition, and trace element analysis. In conclusion, the combination of these four signatures is sufficient to distinguish the different origins among these studied UOCs.

and nuclear chemistry↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Nondestructive and destructive assay for forensics characterization of weapons-grade plutonium produced in LEU irradiated in a thermal neutron spectrum

A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic analysis environment for nuclear forensic analyses

We report a Dynamic Analysis Environment (DAE) software package is introduced to facilitate group inclusion/exclusion method testing, evaluation and comparison for pre-detonation nuclear forensics applications. Employing DAE, the multivariate signatures of a questioned material can be compared to the signatures for different, known groups, enabling the linking of the questioned material to its potential process, location, or fabrication facility. Advantages of using DAE for group inclusion/exclusion include built-in query tools for retrieving data of interest from a database, the recording and documentation of all analysis steps, a clear visualization of the analysis steps intelligible to a non-expert, and the ability to integrate analysis tools developed in different programming languages. Two group inclusion/exclusion methods are implemented in DAE: principal component analysis, a parametric feature extraction method, and k nearest neighbors, a nonparametric pattern recognition method. Spent Fuel Isotopic Composition (SFCOMPO), an open source international database of isotopic compositions for spent nuclear fuels (SNF) from 14 reactors, is used to construct PCA and KNN models for known reactor groups, and 20 simulated SNF samples are utilized in evaluating the performance of these group inclusion/exclusion models. For all 20 simulated samples, PCA in conjunction with the Q statistic correctly excludes a large percentage of reactor groups and correctly includes the true reactor of origination. As a result, employing KNN, 14 of the 20 simulated samples are classified to their true reactor of origination.

97 MATHEMATICS AND COMPUTING↗

Planning, design and logistics of a decision analysis study: The FBI/Ames study involving forensic firearms examiners

This paper describes design and logistical aspects of a decision analysis study to assess the performance of qualified firearms examiners working in accredited laboratories in the United States in terms of accuracy (error rate), repeatability, and reproducibility of decisions involving comparisons of fired bullets and cartridge cases. The purpose of the study was to validate current practice of the forensic discipline of firearms/toolmarks (F/T) examination. It elicited error rate data by counting the number of false positive and false negative conclusions. Preceded by the experimental design, decisions, and logistics described herein, testing was ultimately administered 173 qualified, practicing F/T examiners in public and private crime laboratories. The first round of testing evaluated accuracy, while two subsequent rounds evaluated repeatability and reproducibility of examiner conclusions. This project expands on previous studies by involving many F/T examiners in challenging comparisons and by executing the study in the recommended double-blind format.

99 GENERAL AND MISCELLANEOUS↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Intrinsic dosimetry of glass containers used to transport nuclear materials: Potential implications to the fields of waste management and nuclear forensics

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 min to w60 days following exposure to a dose of up to 100 Gy. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 0.5 and 1 Gy. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and no significant variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 3.3 Gy, a 100 Gy dose would still be detected 2.7E3 years after exposure. Here, we introduce the concept of intrinsic dosimetry, the measurement of the total absorbed dose received by the walls of a container containing radioactive material. The foreseen advantage of intrinsic dosimetry comes from considering the measured absorbed dose received by containers in concert with the characteristics (amount, type) of the source of that dose, the radioactive material contained within the walls of the container, in order to provide enhanced information about the history of an unknown sample in question. Three hypothetical scenarios are presented to introduce this method and to illustrate how intrinsic dosimetry might benefit the fields of nuclear forensics and waste management.

glass↗

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Samarium isotope compositions of uranium ore concentrates: A novel nuclear forensic signature

Uranium ore is mined and milled to produce uranium ore concentrate (UOC), a regulated product of the nuclear fuel cycle. Additionally, diversion of UOC from the fuel cycle into possible weapons production is a key concern in global nonproliferation efforts. As such, the ability to trace the origin of seized nuclear materials is imperative to law enforcement efforts. Although isotopic signatures of UOCs have proven fruitful to pinpoint sample provenance, new isotopic signatures are needed because most existing isotopic signatures are not indicative of the original ore body from which the U is derived. In this work, we developed a new method to separate samarium (Sm) from a U-rich sample matrix and report the first Sm isotope compositions of 32 UOCs derived from a variety of worldwide uranium mines. Relative to terrestrial standards, approximately half the UOCs have resolved and anticorrelated 149 Sm- 150 Sm isotope compositions, consistent with the capture of thermal neutrons by 149 Sm in the ore body. The UOCs with anomalous Sm isotope compositions tend to derive from older (~>1.5Ga) and higher-grade ore bodies, although other factors, such as the presence of neutron moderators like water, also play a role. Nonetheless, the Sm isotope compositions of UOCs directly reflects the neutron fluence over the history of the original ore body and can be used to discern different geologic conditions associated with that ore body. Overall, this work demonstrates the potential use of Sm isotopes as a novel nuclear forensics signature for origin assessment of UOCs.

58 GEOSCIENCES↗

Innovative high-temperature ammonium bifluoride fusion and rapid analysis of elements with nuclear forensic value

High-temperature ammonium bifluoride (ABF) fusions were evaluated for potential use in rapid dissolution of post-detonation nuclear debris. The ABF fusion was carried out in a Pt crucible which allowed evaluation of higher fusion and evaporation temperatures. The high-temperature ABF fusion dissolution method was evaluated using geological reference materials: USGS QLO-1a Quartz Latite, USGS SDC-1 Mica Schist, and NIST 278 Obsidian Rock. The optimized dissolution method involved a 10 min fusion at 540 °C, a 5 min reflux in 8 M HNO 3 , an evaporation at 300 °C and final dilution into 45 mL of 2% (v/v) HNO3. The final solution was filtered after heating at 105 °C using a hotblock. This dissolution method was simple, requiring only a hotplate or hotblock, filtered samples were available for ICP-MS analysis or radiochemical separation within 150 min, and was found to have high (>90%) recovery for many isotopes of interest in nuclear forensics applications. U and Pu in the dissolved material was separated using TEVA and UTEVA extraction chromatography columns, a process which resulted in >90% recovery. An irradiated U tracer was spiked into the material prior to dissolution and analyzed for recovery of major fission products and 239Np. The monitored radionuclides had recoveries of greater than 90%, except for the volatile radioiodine isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impurity Profiling of a Chemical Weapon Precursor for Possible Forensic Signatures by Comprehensive Two-Dimensional Gas Chromatography/Mass Spectrometry and Chemometrics

In this work we present the feasibility of using analytical chemical and chemometric methodologies to reveal and exploit the organic impurity profiles from commercial dimethyl methylphosphonate (DMMP) samples to illustrate the type of forensic information that may be obtained from chemical-attack evidence. Using DMMP as a model compound for a toxicant that may be used in a chemical attack, we used comprehensive two-dimensional gas chromatography mass spectrometric detection (GC × GC-TOFMS) to detect and identify trace organic impurities in six samples of commercially acquired DMMP. The GC x GC-TOFMS data were analyzed to produce impurity profiles for all six DMMP samples using 29 analyte impurities. The use of PARAFAC for the mathematical resolution of overlap GC x GC peaks ensured clean spectra for the identification of many of the detected analytes by spectral library matching. The use of statistical pairwise comparison revealed that there were trace impurities that were quantitatively similar and different among five of the six DMMP samples. Two of the DMMP samples were revealed to have identical impurity profiles by this approach. The use of nonnegative matrix factorization proved that there were five distinct DMMP sample types as illustrated by the clustering of the multiple DMMP analyses into 5 distinct clusters in the scores plots. The two indistinguishable DMMP samples were confirmed by their chemical supplier to be from the same bulk source. Sample information from the other chemical suppliers supported that the other five DMMP samples were likely from different bulk sources. These results demonstrate that the matching of synthesized products from the same source is possible using impurity profiling. In addition, the identified impurities common to all six DMMP samples provide strong evidence that basic route information can be obtained from impurity profiles. In addition, impurities that may be unique to the sole bulk manufacturer of DMMP were found in some of the DMMP samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proteomics for Microbial Forensics

Mass spectrometry-based proteomics is a powerful tool for the detection and characterization of microbes of forensic and national security concern. Both targeted and untargeted proteomics methods have been developed for the taxonomic classification of unknown microbial samples. Targeted proteomics assays are can be designed for specific microbes of security concern. Untargeted, library-based matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry is now extensively used in the medical field for microbial identification. Several research groups have developed data analysis pipelines for organism identification/taxonomic classification from untargeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) data, an application which has some overlap with the field of metaproteomics. This chapter reviews these organism identification techniques. However, organism identification/classification is also commonly done by whole genome sequencing. Using examples from published literature, this chapter also highlights several examples of how proteomics approaches can provide information that cannot be acquired from DNA sequencing alone, such as distinguishing laboratory-adapted bacteria from closely-related wild isolates, and characterizing the growth medium of bacteria and the host cells of virus particles.

proteomics, microbial forensics, mass spectrometry↗