Search NASA⌕ Search

SEARCH · Search NASA

Results for “framing camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multiframe X-ray diffraction on the OMEGA EP laser

A method of measuring multiple temporally resolved powder x-ray diffraction measurements during a single dynamic compression laser experiment has been demonstrated on the OMEGA EP laser. Up to four time-gated snapshots of the x-ray diffraction pattern are collected on an ultrafast x-ray framing camera with a 2θ scattering angle coverage of 48°–65° and 400-ps temporal resolution with the potential for 10°–160° and 200-ps resolution. X-ray diffraction snapshots capture the transformation to a high-pressure β phase in ramp-compressed Zr, constraining the atomic structure and pressure–density equation-of-state in a single shot. Here, this platform will be used to constrain transition pressures, understand the role of kinetics, and verify the existence of hysteresis and metastability on phase transformations at the lattice level under single-shot dynamic compression.

47 OTHER INSTRUMENTATION↗

Experimental studies and simulations of hydrogen pellet ablation in the stellarator TJ-II

Plasma core fuelling is a key issue for the development of steady-state scenarios in large magnetically-confined fusion devices, in particular for helical-type machines. At present, cryogenic pellet injection is the most promising technique for efficient fuelling. Here, pellet ablation and fuelling efficiency experiments, using a compact pellet injector, are carried out in electron cyclotron resonance and neutral beam injection heated plasmas of the stellarator TJ-II. Ablation profiles are reconstructed from light emissions collected by silicon photodiodes and a fast-frame camera system, under the assumptions that such emissions are loosely related to the ablation rate and that pellet radial acceleration is negligible. In addition, pellet particle deposition and fuelling efficiency are determined using density profiles provided by a Thomson scattering system. Furthermore, experimental results are compared with ablation and deposition profiles provided by the HPI2 pellet code, which is adapted here for the stellarators Wendelstein 7-X (W7-X) and TJ-II. Finally, the HPI2 code is used to simulate ablation and deposition profiles for pellets of different sizes and velocities injected into relevant W7-X plasma scenarios, while estimating the plasmoid drift and the fuelling efficiency of injections made from two W7-X ports.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the electrothermal and MHD instabilities in exploding cylindrical foil liner

Abstract An experimental and numerical study of the plasma instabilities in an electrical exploding cylindrical Al liner is reported. The Al liner 3 mm in diameter and 10 μ m in thickness is exploded at the Qin-1 facility (450 ns, 400 kA). Various diagnostics, such as multi-frame laser shadowgraphy, an x-ray framing camera, and an x-ray backlighting system are developed. The different imaging systems are sensitive to plasma of different areal densities based on the comparison between the experiments and simulation, which reveal the dynamics of the exploding liner in more detail. The laser shadow images show the low-density plasma (∼1–2 × 10 −4 g cm −2 ) at the edge of the liner, and both the amplitude and wavelength of the plasma instabilities increase over time, which are considered to be magnetohydrodynamic (MHD) instabilities rather than electrothermal instabilities. During the ablation of the liner, quasi-periodic azimuthally correlated striations are directly observed in extreme ultraviolet (EUV) self-emission images. Meanwhile, the vertical filaments, which are electrothermal instabilities for plasma under the condition of ∂ η /∂ T < 0, are also observed in EUV self-emission images. The x-ray backlighting images of the exploding liner are obtained by placing an X -pinch load on the current-return path to serve as an x-ray point source (∼1 ns, ∼10 μ m). The x-ray backlighting results show the behavior of the high-density plasma (∼1.89 × 10 −3 g cm −2 ), which includes the transition from electrothermal to MHD instabilities. Finally, we realized a 2D MHD simulation of the exploding liner under experimental conditions, which shows good agreement with the results of the experimental perturbation.

Physics↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Study of the glow dynamics in a laser-produced plasma jet expanding across the magnetic field

Results are presented from experimental studies of the glow dynamics of a plasma jet generated during the irradiation of a plane aluminum target by an iodine laser pulse with the wavelength 1.315 {mu}m. The laser pulse energy was 330-480 J, the pulse duration was 0.5 ns, and the focal spot diameter was 3 mm, the laser intensity on the target surface being {approx}10{sup 13} W/cm{sup 2}. The jet expanded across an external magnetic field with the strength {approx}1 kOe. The residual air pressure in the vacuum chamber was {approx}10{sup -5} Torr. The spatiotemporal behavior of the jet glow was investigated using a nine-frame camera in two mutually perpendicular directions (along and across the magnetic field). The results of measurements indicate azimuthal asymmetry of the jet expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the core-corona structure formed during the explosion of an aluminum wire in vacuum

The time evolution of the matter parameters and current distribution in the discharge channel formed during a nanosecond explosion of a 25-{mu}m-diameter 12-mm-long aluminum wire was studied in a series of experiments with the following parameters: the discharge voltage was U{sub 0} = 20 kV, the current amplitude was I{sub max} {approx} 8 kA, and the current rise rate was dI/dt {approx} 40 A/ns. Optical shadow and schlieren images of the discharge channel were obtained using the second harmonic of a YAG: Nd{sup +3} laser, and UV images of the discharge channel self-radiation were recorded using a four-frame camera with a microchannel plate. The process of aluminum wire explosion was simulated numerically (including simulations performed from the 'cold start'). The numerical results were compared with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of error-compensating algorithms for sinusoidal phase shifting interferometry

An improved approach to interferometry using sinusoidal phase shifting balances several harmonic components in the interference signal against each other. The resulting computationally efficient phase-estimation algorithms have low sensitivity to errors such as spurious intensity noise, vibration, and errors in the phase shift pattern. Specific example algorithms employing 8 and 12 camera frames illustrate design principles that are extendable to algorithms of any length for applications that would benefit from a simplified, sinusoidal phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Emission Characteristics in Laser Induced Breakdown Spectroscopy of Silicon with Mid-Infrared, Multi-Millijoule, Nanosecond Laser Pulses from a Ho:YLF Excitation Source

Here, we characterized the plasma emission produced by the interaction of multimilijoule, 40 ns duration, mid-infrared laser pulses with a silicon surface. The laser pulses were produced by a Q-switched Ho:YLF master oscillator power amplifier system. Using spectral measurements and a framing camera we observed a spatial separation of the plasma plume, increased emission signal with low white light generation, and a drop in the time- and space-averaged apparent plasma density with increasing pump energy. Our findings can be explained by continuous heating of the plasma by the pump pulse due to the more efficient inverse bremsstrahlung absorption at longer wavelengths.

47 OTHER INSTRUMENTATION↗

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Experimental Verification of the Kruskal-Shafranov Stability Limit in Line-Tied Partial Toroidal Plasmas

The stability properties of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas, 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., qa = 1).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ablative Richtmyer-Meshkov Experiments

Figure 1 shows a schematic of experimental setup for nonlinear Richtmyer-Meshkov (RM) instability experiments on OMEGA. Planar 15, 30, and 50-μm-thick CH targets were driven with three UV beams using a 6-ns square pulse shape, total energy of ~0.7 kJ, and laser intensity of ~5x10 13 W/cm 2 . Initial target modulations were imposed by laser imprinting using a beam with a special 2D phase plate with modulation wavelength of ~70 microns. The timing of this beam was advanced by ~200 ps, relative to other drive beams that have regular SG distributed phase plates (DPP’s). Figure 2 shows laser beam images, with SG4 DPP, and with a special 2D DPP. Growth of target modulations was measured with x-ray radiography using uranium (~1.3 keV), samarium (~1.8 keV), and tantalum (~2.2 keV) backlighters on a framing camera with 10-μm spatial resolution and 80-ps temporal resolution. Backlighter targets were driven with 2-ns square pulse shape and intensity of ~3x10 14 W/cm 2 using seven additional UV beams. Figure 3 shows an example of measured image at 1.1 ns (near the end of RM phase) taken with 50-μm thick CH foil and tantalum backlighter. Evolution of 2D broadband modulations was observed in RM phase for all target types during a shock transit time before beginning of acceleration and subsequent RT growth. Figure 4 summarizes areal-density evolution of 2D modulation at wavelength of 70 μm for 30-μm and 50-μm thick foils and compares data with predictions of 2D hydro code DRACO. Vertical dashed lines show expected times at the end of RM phase and beginning of the RT phase for these types of foils. Blue data points and curves correspond to 30-μm thick foils, while black curves and data points are for 50-μm-thick foils. Areal density modulations grow throughout RM phase, their evolution is similar to code predictions, validating the simulations.

42 ENGINEERING↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ranchero Armature Test LA-43-CT-2: PBXN-110 Explosive with no smoothing layer. Lower Slobovia, 6/13/13

This test, documented as LA-43-CT-2, was performed to verify calculations which indicate that the smoothing layer employed for Ranchero Armatures is not required when the slapper point spacing is 18 mm (“On the efficacy of an acrylic layer in the Ranchero armature,” Bob Watt, published in “Ranchero Status Report” LA-14463). [Naming this test –CT-2 acknowledges the previous test performed during 1/11 as the initial test in the series, and we will refer to that test as LA-43-CT-1 in the future.] In addition, higher velocity is achieved when the volume occupied by the smoother is replaced by HE. Two framing cameras were used on the shot, and a 20 point PDV array was fielded to ascertain armature performance in specific conditions. The conclusions are that the armature is smooth enough, and the terminal velocity is increased from ~3.1 mm/μs to ~3.3 mm/μs. The armature tested had casting voids in the HE that were observed in pre-test inspections, and were expected to cause ruptures. (See Appendix 3 of the Ranchero Status Report.) Such “blowouts” were observed in all three locations identified in pre-shot inspection. In addition, ruptures occurred in locations having no pre-shot indication of a problem. These unpredicted blowouts have a difference in appearance from those typically seen. Further visual examination of the inspection radiographs do not reveal the cause, and that is a serious concern for future efforts with such castings. A path forward will include attempting to digitize the inspection x-rays for the charge tested, to see if the cause of the “new” ruptures can be found via computer enhancement. In addition, there are two additional armatures from the same casting lot, and these might also be tested to see if there is some problem with the HE or the armature material in this batch. For now, this plan is on hold, pending the outcome of tests and cost estimates related to using PBX-9501 in place of the PBXN-110. Casting issues would be eliminated in such configurations.

42 ENGINEERING↗

Spall strength and ejecta production of gold under explosively driven shock wave compression

Explosively driven shock wave experiments were conducted to characterize the spall strength and ejecta production of high-purity cast gold samples. The samples were from 0.75 to 1.84 mm thick and 30 mm in diameter. Peak stresses up to 44 GPa in gold were generated using PBX-9501 high explosive. Sample free surface and ejecta velocities were recorded using photonic Doppler velocimetry techniques. Lithium niobate pins were used to quantify the time dependence of the ejecta density and the total ejected mass. An optical framing camera for time-resolved imaging and a single-image x-ray radiograph were used for additional characterization. Free surface velocities exhibited a range of spall strengths from 1.7 to 2.4 GPa (mean: 2.0 ±0.3 GPa). The pullback signals were faint, minimal ringing was observed in the velocity records, and the spall layer continued to decelerate after first pull back. These results suggest finite tensile strength was present for some time after the initial void formation. Ejecta were observed for every sample with a roughened free surface, and the ejecta density increased with increased surface roughness, which was different in every experiment. The total ejected mass is consistent with the missing mass model.

36 MATERIALS SCIENCE↗

Ti Hemi boombox experiment

Previous deformation experiments in which IR imaging was used pointed to a correlation in between IR signature in areas where heat was expected to be. The surface is not uniform during deformation experiments which cause cracks in the image in areas with increased temperature. To measure temperature under dynamic conditions, simultaneous reflectivity and radiance measurement under events of interest is needed. To measure a temperature measurement, a Reflectance measurement taken by framing camera at the edge of the camera sensitivity (700nm). Allows relative measurement at this wavelength. At reasonable temperatures the spectral radiance should peak near 2u and be 3-4 orders of magnitude higher than at 700 nm.

36 MATERIALS SCIENCE↗

LANL Lightning Flash Time Duration Ground Truth

Video cameras were used to record cloud-to-ground (CG) lightning flash events on or near Los Alamos National Laboratory (LANL) over 3 days in August, 2018. Custom scripting software was created to automatically trigger camera recording off National Lightning Data Network (NLDN) streamed reporting of CG lightning within 12 miles of LANL. Cameras were sited near meteorology towers at LANL and 4k video captures were manually reviewed to extract still sequence images from 9 identified CG flashes. A camera frame rate of 30 fps was used to estimate time durations of 33-200 milliseconds over this natural lightning dataset.

58 GEOSCIENCES↗