Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A helium-3 cooled bolometer system for one millimeter continuum observations

A new, 1-mm-continuum, bolometer detector system has been constructed employing internal adsorption pumping of He-3 to reach an operating temperature close to 0.4 K. The system spectral bandwidth is 800 to 1200 microns. Although the system was originally designed to be used on the 5-m Hale telescope, it has also been successfully used on the 4-m Anglo-Australian telescope and on the 10-m dish at Owens Valley, California. At the 5-m Hale telescope, the system has a full width-half maximum (FWHM) beam size of 55 sec and an instantaneous noise-equivalent flux density of 6 Jy/square root of (Hz)/ in good weather.

Roellig, T. P. L.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

A transient digitiser for fast air shower events

Air shower structure are often measured on time scales of a few nanoseconds. Longitudinal disk structure near the core is of the order of meters in dimension, air Cerenkov pulses have full widths at half maximum of the order of tens of nanoseconds, and fast timing over typical arrays is usually measured to nanosecond accuracy. oscilloscopes can be used but have very limited dynamic range and are expensive if measurements down to a few nanoseconds are to be made. For the fast Cerenkov work, an instrument with better dynamic range than an oscilloscope and with a time resolution sufficient to allow measurements limited only by system risetime of a few nanoseconds is needed. A 16/32 channel, 8 bit, fast transient digitizer was designed and built which runs at sample intervals down to approx. 1 nanosecond per channel.

Wild, N. R.↗

Grazing incidence metal optics for the Berkeley Extreme Ultraviolet Explorer satellite - A progress report

The four flight Wolter-Schwarzschild mirrors currently under fabrication for the Extreme Ultraviolet Explorer (EUVE) satellite are described. The principal figuring operation of these grazing incidence metal mirrors (gold over nickel on an aluminum substrate) is carried out by diamond turning at the Lawrence Livermore National Laboratories. Turning has been accomplished and optical testing results analyzed for three of the mirrors. As-turned values of 1.7 arc sec full width at half maximum (FWHM) and half energy width (HEW) of 5 arc seconds in the visible have been achieved. These results illustrate the great potential of precision fabrication technology for the production of large grazing incidence optics.

Finley, D.↗

Spatial deconvolution of IRAS galaxies at 60 UM

Using IRAS in a slow scan observing mode to increase the spatial sampling rate and a deconvolution analysis to increase the spatial resolution, several bright galaxies were resolved at 60 micron. Preliminary results for M 82, NGC 1068, NGC 3079 and NGC 2623 show partially resolved emission from 10 to 26 arcsec., full width at half maximum, and extended emission from 30 to 90 arcsec. from the center. In addition, the interacting system, Arp 82, along with Mark 231 and Arp 220 were studied using the program ADDSCAN to average all available survey mode observations. The Arp 82 system is well resolved after deconvolution and its brighter component is extended; the two most luminous objects are not resolved with an upper limit of 15 arcsec. for Arp 220.

Low, Frank J.↗

Confocal unstable-resonator semiconductor laser

GaAs/GaAlAs heterostructure lasers with a monolithic confocal unstable resonator were demonstrated. The curved mirrors satisfying the confocal condition were fabricated by etching. Close to threshold, the lasers operate in a single lateral mode with a nearly collimated output beam. A single-lobe far-field intensity distribution as narrow as 1.9-deg full width at half maximum was measured.

Salzman, J.↗

The mirrors for the Extreme Ultraviolet Explorer

Flight mirrors for the Extreme Ultraviolet Explorer satellite are currently under fabrication. The grazing incidence metal mirrors are Wolter-Schwarzschild Type I and II and are figured by diamond turning. Imaging performance is excellent, with the figure after polishing for the best mirror being such that the full width-half maximum is 1.0 arc seconds and the half energy width is 8 arc seconds measured at visible wavelengths. Surface finish, as determined from scattering measurements in the extreme ultraviolet, is about 20 A rms.

Finley, David S.↗

Electron attachment in F2 - Conclusive demonstration of nonresonant, s-wave coupling in the limit of zero electron energy

Dissociative electron attachment to F2 has been observed in the energy range 0-140 meV, at a resolution of 6 meV (full width at half maximum). Results show conclusively a sharp, resolution-limited threshold behavior consistent with an s-wave cross section varying as sq rt of epsilon. Two accurate theoretical calculations predict only p-wave behavior varying as the sq rt of epsilon. Several nonadiabatic coupling effects leading to s-wave behavior are outlined.

Chutjian, A.↗

Measurement of electron-attachment line shapes, cross sections, and rate constants in HI and DI at ultralow electron energies

Electron-attachment cross sections are reported in the electron energy range 0-150 MeV, at an energy resolution of 6.5 MeV (full width at half maximum) for the molecules HI and DI. Use is made of the Kr photoionization method to obtain cross sections for HI, and a signal intercomparison technique to obtain cross sections and the thermal-attachment rate constant for DI. Attachment properties of the two molecules are very similar. The ratio of attachment cross sections is discussed in terms of the reduced-mass dependence of the dissociation width and the survival probability, and in terms of spectroscopic thresholds and rotational populations for attachment at 300 K. Approximate potential-energy curves for the lowest states of the neutral molecule and negative ion are given.

Alajajian, S. H.↗

Low-altitude trapped protons at the geomagnetic equator

Geomagnetically trapped protons in the 0.6- to 9-MeV energy range were measured at latitudes near the geomagnetic equator by the Phoenix 1 experiment on board the S81-1 mission from May to November 1982. The protons show a distribution in latitude along the line of minimum magnetic field strength with a full width at half maximum of about 10 deg but with no appreciable longitudinal variation. Between 170 and 290 Km the peak proton flux shows a fifth-power altitude dependence, in contrast to previous measurements at higher altitudes, possibly demonstrating source attenuation. The efficiency of the telescope is calculated as a function of particle pitch angle and used to investigate the time dependence (1969-1982) of the intensity.

Guzik, T. G.↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Performance and durability of HgI2 X-ray detectors for space missions

Considerable progress has been achieved recently in HgI2 detector fabrication technology and amplification electronics. An energy resolution of 198 eV (full width at half maximum) has been obtained for the Mn k-alpha line of 5.9 keV in a practical X-ray probe without the use of cryogenic cooling. Detectors prepared with Parylene-C encapsulation have demonstrated perfect reliability in two-year tests under high vacuum and temperature and bias cycling. Other HgI2 detectors have been used to demonstrate proton-radiation-damage resistance to levels of 10 to the 12 protons/sq cm at 10.7 MeV. It is concluded that HgI2 detectors are suitable for the ordinary requirements of energy dispersive detectors in X-ray spectroscopy systems.

Iwanczyk, J. S.↗

A position sensitive detector for EUV remote sensing

The authors describe a photon-counting extreme ultraviolet (EUV) detector system used in a rocket-borne spectroscopic instrument for remote sensing of upper atmospheric composition and temperature. The detector uses a KBr coated microchannel plate (MCP) Z stack in combination with a wedge-and-strip image readout system. Three separate detector fields of view are used to sense the Earth dayglow spectrum (980 A to 1040 A, and 1300 A to 1360 A) and the solar EUV spectrum (250 A to 1400 A). The authors demonstrate high gain (2 x 107), tight pulse-height distribution (35 percent FWHM), and a spatial resolution of about 35 microns FWHM (full width at half maximum), which is the highest resolution for a wedge-and-strip anode MCP detector flown to date. The background, image linearity, and flat-field performance are discussed. Raw spectra from the rocket flight are also presented.

Siegmund, O. H. W.↗

Further observations of rotationally excited far infrared OH16 and OH18 emission in Orion-KL: Tighter constraints on the nature of the emitting region

The Orion-KL region, within 1 arc minute, is observed. The rotational cross ladder (53.351 microns) and rotational ground state (120.1719 microns) transitions are studied. It is shown that these lines exhibit a P-Cygni profile and unambiguously show that the OH gas is expanding out from the central BN-KL infrared cluster. The OH-16 rotational ground state transition (119.234 microns) is velocity resolved and it is found that its intrinsic full width at half maximum is 75 km/s. The line fluxes and line profiles are modeled and it is shown that no single temperature and density component can reproduce the data. Rather, the best fit to the data requires emission from three main components of the gas: post shocked gas with the profiles of temperature, density, and OH abundance; a high density component to the cool post shocked region; and the plateau region.

Melnick, G. J.↗

High-power low-threshold graded-index separate confinement heterostructure AlGaAs single quantum well lasers on Si substrates

A high-power low-threshold graded-index separate confinement heterostructure AlGaAs single quantum well laser on Si substrates has been demonstrated for the first time by a hybrid growth of migration-enhanced molecular beam epitaxy followed by metalorganic vapor phase epitaxy. The quantum well laser showed an output power of more than 400 mW per facet under pulsed conditions. A room-temperature threshold current of 300 mA was obtained with a differential quantum efficiency of 40 percent without facet coating. The threshold current density was 550 A/sq cm for a cavity length of 500 microns. These results show the highest peak power reported to date for low-threshold lasers on Si substrates. The full width at half maximum of the far-field pattern parallel to the junction was 6 deg. Threshold current densities as low as 250 A/sq cm were obtained for lasers on GaAs substrates.

Kim, Jae-Hoon↗

Highly nonlinear magnetic pulses at Comet Giacobini-Zinner

Nonlinear solitary magnetic pulses have been detected near the outbound bow shock/wave of Comet Giacobini-Zinner. The pulses have peak field-to-background compression ratios ranging from 2.3 to 7.0 and full-width half-maximum durations from 12 to 72s, comparable to the H2O group ion gyroperiod. Because all of the solitary waves have the same spacecraft-frame polarizations, it is suggested that the waves may have phase speeds greater than the solar wind speed. The role that the waves may play with the bow shock is discussed briefly.

Tsurutani, Bruce T.↗