Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Properties of the -513 km/s Ejecta in the Spectrum of Eta Carinae

In the spectral region 2400-3160A of Eta Carinae, we have identified approximately 500 absorption lines each with up to twenty velocity components. The -512 kilometers per second component is truely unique as 1) the typical line width is less than 3 kilometers per second, 2) the identified lines are in Fe I, Fe II, V II and Ti II, and 3) the lines originate from lower levels up to 2000 cm-1 above the ground level. We have measured the velocity centers, full width at half maximum and equivalent widths for approximately 100 absorption lines. Initial results were very confusing as we found more variation in central velocities than would be expected from known STIS echelle wavelength standards. Upon further review, we found that the reporteded wavelengths in the NIST and Kurucz databases were not sufficiently accurate. S. Johansson searched FTS laboratory measurements performed at Lund for V II and Ti II and provided much improved wavelength measures. Likewise, we find more variation in column density than expected statistically from the accuracy of the equivalent widths for lines originating from the same energy level. We are reviewing the published gf values and our measurements to improve the measured column densities. Some spectroscopy of the ejecta has already been accomplished at two different epochs. Preliminary measures of equivalent widths indicate there may be some variation with time, but we await measurements planned for July 2003 during the upcoming spectroscopic minimum of Eta Carinae. These observations were accomplished through STScI and funding was from STIS GTO resources.

Danks, Anthony↗

Retrieval of Ozone Column Content from Airborne Sun Photometer Measurements During SOLVE II: Comparison with SAGE III, POAM III,THOMAS and GOME Measurements

During the Second SAGE 111 Ozone Loss and Validation Experiment (SOLVE II), the 14- channel NASA Ames Airborne Trackmg Sunphotometer (AATS-14) was mounted on the NASA DC-8 and successfully measured spectra of total and aerosol optical depth (TOD and AOD) during the sunlit portions of eight science flights. Values of ozone column content above the aircraft have been derived from the AATS-14 data by using a linear least squares method. For each AATS-14 measured TOD spectrum, this method iteratively finds the ozone column content that yields the best match between measured and calculated TOD. The calculations assume the known Chappuis ozone band shape and a three-parameter AOD shape (quadratic in log-log space). Seven of the AATS-14 channels (each employing an interference filter with a nominal full-width at half maximum bandpass of -5 nm) are within the Chappuis band, with center wavelengths between 452.9 nm and 864.5 nm. One channel (604.4 nm) is near the peak, and three channels (499.4, 519.4 and 675.1 nm) have ozone absorption within 30-40% of that at the peak. For the typical DC-8 SOLVE II cruising altitudes of approx. 8-12 km and the background stratospheric aerosol conditions that prevailed during SOLVE 11, absorption of incoming solar radiation by ozone comprised a significant fraction of the aerosol-plus-ozone optical depth measured in the four AATS-14 channels centered between 499.4 and 675.1 nm. Typical AODs above the DC-8 ranged from 0.003-0.008 in these channels. For comparison, an ozone overburden of 0.3 atm-cm (300 DU) translates to ozone optical depths of 0.009,0.014, 0.041, and 0.012, respectively, at these same wavelengths. In this paper, we compare AATS-14 values of ozone column content with temporally and spatially near-coincident values derived from measurements acquired by the Stratospheric Aerosol and Gas Experiment III (SAGE III) and the Polar Ozone and Aerosol Measurement 111 (POAM III) satellite sensors. We also compare AATS-14 ozone retrievals during selected DC-8 latitudinal and longitudinal transects with total column ozone data acquired by the Total Ozone Mapping Spectrometer (TOMS) and the Global Ozone Monitoring Experiment (GOME) satellite sensors. To enable this comparison, the amount of ozone in the column below the aircraft is estimated by combining SAGE and/or POAM data with high resolution, fast response in-situ ozone measurements acquired during the DC-8 ascent at the start of each science flight.

Livingston, J.↗

In-Flight Edge Response Measurements for High Spatial Resolution Remote Sensing Systems

In-flight measurement of spatial resolution were conducted as part of the ASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. Characterization included remote sensing systems with ground sample distance (GSD) of 1 meter or less, such as the panchromatic imager on-board the ICONOS satellite and the airborne ADAR System 5500 multispectral instrument. Final image products were used to evaluate the effect of both the image acquisition system (e.g., optics, electronics, motion, jitter, atmosphere) and image post-processing (e.g., resampling, modulation trasfer function (MTF) compensator). Spatial resolution was characterized by full width at half maximum (FWHM) of an edge response-derived line spread function. This was found to be a more robust measure of spatial resolution than the value of NTF at Nyquist frequency The edge responses were analysed using the tilted-edge technique that ovecomes the spatial sampling limitations of the digital imaging systems. As an enhancement to existing algorithms, the slope of the edge response and the orientation of the edge target were determined by a single computational process. Adjacent black and white square panels, either painted on a flat surface or deployed as traps, formed the ground-based edge targets used in the tests. Orientation of the deployable tarps was optimized beforehand, based on simulations of the imaging system. Numerous edge target images were analyzed for each of the tested sensors. The effect of such factors as acquisition geometry, temporal variability, MTF compensation, and GSD on spatial resolution were investigated.

Blonski, Slawomir↗

Properties of the -513 km/s Ejecta in the Spectrum of Eta Carinae

In the spectral region 2400-3160A of Eta Carinae, we have identified approximately 500 absorption lines each with up to twenty velocity components. The -512 kilometers per second component is truly unique as 1) the typical line width is less than 3 kilometers per second, 2) the identified lines are in Fe I, Fe II, VII and Ti II, and 3) the lines originate from lower levels up to 2000 cm-1 above the ground level. We have measured the velocity centers, full width at half maximum and equivalent widths for approximately 100 absorption lines. Initial results were very confusing as we found bore variation in central velocities than would be expected from known STIS echelle wavelength standards. Upon further review, we found that the reported wavelengths in the NIST and Kurucz databases were not sufficiently accurate. S. Johansson searched FTS laboratory measurements performed at Lund for V II and Ti II and provided much improved wavelength measures. Likewise, we find more variation in column density than expected statistically from the accuracy of the equivalent widths for lines originating from the same energy level. We are reviewing the published gf values and our measurements to improve the measured column densities. Some spectroscopy of the ejecta has already been accomplished at two different epochs. Preliminary measures of equivalent widths indicate there may be some variation with time, but we await measurements planned for July 2003 during the upcoming spectroscopic minimum of Eta Carinae. The observations were accomplished through STScI and funding was from STIS GTO resources.

Danks, A.↗

Functional Flight Test Report for Positive Systems' ADAR System 5500 Sensor SN8 Linear

This report describes results of the functional flight test conducted with the Positive Systems' ADAR 5500 sensor system (serial number 8, linear configuration) near Winslow, Arizona on June 30 and July 1, 1999. The in-flight test is one component of the NASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. It allows to measure characteristics of the entire sensor system affected by both performance of the sensor during a flight and post-flight image processing. The following characteristics were analyzed: changes of dark digital numbers (DN's), radiometric linearity, signal-to-noise ratio (SNR), spatial resolution, and geolocation accuracy. The measured characteristics were compared with the image product specifications defined in the Positive Systems' SDP contract. Dependence of the dark DN's on several factors was analyzed, but no significant correlation was found. However, the observed changes in dark DN's were relatively small, which justifies usage of a constant value in the dark DN subtraction procedure during post-processing. Dependence of measured at-sensor, in-band radiance (in arbitrary units) on measured in-band ground reflectance is very well described by a linear function - The sensor fulfills the linearity requirement. Measured SNR values lower than the contract specifications, but accuracy of that test was possibly affected by non-uniformity of the employed gray-scale panels. The SNR values are generally sufficiently high for most applications. SNR can also be improved during standard flights by using longer exposure times. Full width at half maximum (FWHM) of an edge response derived line spread function was used as a measure of spatial resolution. FWHM was generally smaller than twice the ground sample distance (GSD), in agreement with the contract specifications. Accuracy of the geolocation information, which is provided for the particular images in a metadata file, was found to meet contract requirements as well.

Stanley, Tom↗

Visualization of a Capsule Entry Vehicle Reaction-Control System (RCS) Thruster

Planar laser-induced fluorescence (PLIF) was used to visualize the reaction control system (RCS) jet flow emanating from the aft-body of an Apollo-geometry capsule test article in the NASA Langley Research Center 31-Inch Mach 10 Air wind tunnel. The RCS jet was oriented normal to the aft surface of the model and had a nominal Mach number of 2.94. The composition of the jet gas by mass was 95% nitrogen (N2) and 5% nitric oxide (NO). The RCS jet flowrate varied between zero and 0.5 standard liters per minute and the angle of attack and tunnel stagnation pressure were also varied. PLIF was used to excite the NO molecules for flow visualization. These flow visualization images were processed to determine the trajectory and to quantify the flapping of the RCS jet. The spatial resolution of the jet trajectory measurement was about 1 mm and the single-shot precision of the measurement was estimated to be 0.02 mm in the far field of the jet plume. The jet flapping, measured by the standard deviation of the jet centerline position was as large as 0.9 mm, while the jet was 1.5-4 mm in diameter (full width at half maximum). Schlieren flow visualization images were obtained for comparison with the PLIF. Surface pressures were also measured and presented. Virtual Diagnostics Interface (VIDI) technology developed at NASA Langley was used to superimpose and visualize the data sets. The measurements demonstrate some of the capabilities of the PLIF method while providing a test case for computational fluid dynamics (CFD) validation.

Danehy, P. M.↗

Electron-Impact-Induced Emission Cross Sections of Neon in the Extreme Ultraviolet

We have measured the extreme ultraviolet (EUV) spectrum of neon produced by electron excitation. The measurements were obtained under optically thin conditions, and at a spectral resolution of 0.5 nm full width at half maximum (FWHM). The most prominent features of the EUV spectrum between 45-80 nm are the resonance lines of Ne I at 73.6 and 74.4 nm and a multiplet of Ne II at 46.14 nm (the average value for the line center of the two closely spaced ion lines at 46.07 and 46.22 nm). Absolute emission cross sections of these lines at 300 eV were measured and compared to other previous measurements.

Neon extreme ultraviolet (EUV) spectrum EUV resona↗

Middle UV to Near-IR Spectrum of Electron-Excited SO2

We investigated the electron impact-induced fluorescence spectrum of SO2 to provide excitation cross sections for modeling Io's mission spectrum and analyzing Cassini Imaging Science Subsystem observations. The electron-excited middle-ultraviolet visible optical near-infrared (VOIR) emission spectrum of SO2 gas was generated in the laboratory and studied from 2000 to 11,000 A at a resolution of (Delta)(lamda) approximately 2.5 A full width at half maximum (FWHM). The VOIR laboratory spectrum longward of 6000 A consists entirely of S I, II and O I, II multiplets for electron impact energies above approximately 15 eV. Between 2000 and 6000 A, we find previously identified molecular bands from both SO and SO2. This work represents a significant improvement in spectral resolution over our earlier work done at 18 A FWHM. From a measurement of the medium-resolution spectrum, we provide detailed 25- and 100-eV emission cross sections for spectral features from 2000 to 11,000 A . On the basis of these data, we suggest future ground-based and satellite telescopic observations in the VOIR that are of promise for understanding Io's atmosphere.

sulpher dioxide↗

A Low Cross-Polarization Smooth-Walled Horn with Improved Bandwidth

Corrugated feed horns offer excellent beam symmetry, main beam efficiency, and cross-polar response over wide bandwidths, but can be challenging to fabricate. An easier-to-manufacture smooth-walled feed is explored that approximates these properties over a finite bandwidth. The design, optimization and measurement of a monotonically-profiled, smooth-walled scalar feedhorn with a diffraction-limited approximately 7 degrees full width at half maximum (FWHM) is presented. The feed was demonstrated to have low cross polarization (<-30 dB) across the frequency range 33-45 GHz (30% fractional bandwidth). A return loss better than -28 dB was measured across the band.

Zeng, Lingzhen↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Using Whispering-Gallery-Mode Resonators for Refractometry

A method of determining the refractive and absorptive properties of optically transparent materials involves a combination of theoretical and experimental analysis of electromagnetic responses of whispering-gallery-mode (WGM) resonator disks made of those materials. The method was conceived especially for use in studying transparent photorefractive materials, for which purpose this method affords unprecedented levels of sensitivity and accuracy. The method is expected to be particularly useful for measuring temporally varying refractive and absorptive properties of photorefractive materials at infrared wavelengths. Still more particularly, the method is expected to be useful for measuring drifts in these properties that are so slow that, heretofore, the properties were assumed to be constant. The basic idea of the method is to attempt to infer values of the photorefractive properties of a material by seeking to match (1) theoretical predictions of the spectral responses (or selected features thereof) of a WGM of known dimensions made of the material with (2) the actual spectral responses (or selected features thereof). Spectral features that are useful for this purpose include resonance frequencies, free spectral ranges (differences between resonance frequencies of adjacently numbered modes), and resonance quality factors (Q values). The method has been demonstrated in several experiments, one of which was performed on a WGM resonator made from a disk of LiNbO3 doped with 5 percent of MgO. The free spectral range of the resonator was approximately equal to 3.42 GHz at wavelengths in the vicinity of 780 nm, the smallest full width at half maximum of a mode was approximately equal to 50 MHz, and the thickness of the resonator in the area of mode localization was 30 microns. In the experiment, laser power of 9 mW was coupled into the resonator with an efficiency of 75 percent, and the laser was scanned over a frequency band 9 GHz wide at a nominal wavelength of approximately equal to 780 nm. Resonance frequencies were measured as functions of time during several hours of exposure to the laser light. The results of these measurements, plotted in the figure, show a pronounced collective frequency drift of the resonator modes. The size of the drift has been estimated to correspond to a change of 8.5 x 10(exp -5) in the effective ordinary index of refraction of the resonator material.

Matsko, Andrey↗

Characteristics of a Broadband Dye Laser Using Pyrromethene and Rhodamine Dyes

A broadband dye laser pumped by a frequency-doubled Nd:YAG laser with a full-width half-maximum (FWHM) from 592 to 610 nm was created for the use in a dual-pump broadband CARS system called WIDECARS. The desired broadband dye laser was generated with a mixture of Pyrromethene dyes as an oscillator gain medium and a spectral selective optic in the oscillator cavity. A mixture of Rhodamine dyes were used in the amplifier dye cell. To create this laser a study was performed to characterize the spectral behavior of broadband dye lasers created with Rhodamine dyes 590, 610, and 640, Pyrromethene dyes 597 and 650 as well as mixture of these dyes.

Tedder, Sarah A.↗

Fiber-Optic Gratings for Lidar Measurements of Water Vapor

Narrow-band filters in the form of phase-shifted Fabry-Perot Bragg gratings incorporated into optical fibers are being developed for differential-absorption lidar (DIAL) instruments used to measure concentrations of atmospheric water vapor. The basic idea is to measure the relative amounts of pulsed laser light scattered from the atmosphere at two nearly equal wavelengths, one of which coincides with an absorption spectral peak of water molecules and the other corresponding to no water vapor absorption. As part of the DIAL measurement process, the scattered light is made to pass through a filter on the way to a photodetector. Omitting other details of DIAL for the sake of brevity, what is required of the filter is to provide a stop band that: Surrounds the water-vapor spectral absorption peaks at a wavelength of 946 nm, Has a spectral width of at least a couple of nanometers, Contains a pass band preferably no wider than necessary to accommodate the 946.0003-nm-wavelength water vapor absorption peak [which has 8.47 pm full width at half maximum (FWHM)], and Contains another pass band at the slightly shorter wavelength of 945.9 nm, where there is scattering of light from aerosol particles but no absorption by water molecules. Whereas filters used heretofore in DIAL have had bandwidths of =300 pm, recent progress in the art of fiber-optic Bragg-grating filters has made it feasible to reduce bandwidths to less than or equal to 20 pm and thereby to reduce background noise. Another benefit of substituting fiber-optic Bragg-grating filters for those now in use would be significant reductions in the weights of DIAL instruments. Yet another advantage of fiber-optic Bragg-grating filters is that their transmission spectra can be shifted to longer wavelengths by heating or stretching: hence, it is envisioned that future DIAL instruments would contain devices for fine adjustment of transmission wavelengths through stretching or heating of fiber-optic Bragg-grating filters nominally designed and fabricated to have transmission wavelengths that, in the absence of stretching, would be slightly too short.

Vann, Leila B.↗

Geochemical Mapping of 4 Vesta Begins

By December, the NASA Dawn spacecraft will have descended to a low altitude mapping orbit (LAMO), where the Gamma Ray and Neutron Detector (GRaND) will acquire global mapping data for up to four months. Measurements by GRaND will help answer elusive questions about how Vesta differentiated and the nature of processes that shaped Vesta s surface. The data will be analyzed to determine the abundances of Mg, Si, Fe, K, Th, and H at a spatial resolution of roughly 300 km full-width-at-half-maximum from a 465 km radius orbit. Thermal and fast neutron counting data will be analyzed to determine the neutron macroscopic absorption cross section and average atomic mass, providing constraints on additional elements, such as Ca and Al. GRaND will quantify the elemental composition of coarse spatial units identified by Dawn s Framing Camera (FC) and the Visible & Infrared Spectrometer (VIR). In addition, GRaND will map the mixing ratio of compositional end members selected from the howardite, eucrite and diogenite (HED) meteorites, determine the relative proportions of plagioclase and mafic minerals, and search for compositions that are absent or under-represented in the meteorite collection. While it is generally thought that Vesta s crust on a regional scale should be well-represented by linear mixing of HED whole-rock compositions, there are hints that Vesta may be more diverse than implied by this model. For example, the discovery of K-rich impact glasses in howardites suggests that K-rich rocks may be present on a portion of Vesta s surface, and the analysis of diogenites indicates considerable variability in the magmatic processes that formed them. The chemical composition of materials within Vesta s south polar structure may provide further clues to how it formed. An impact might have exposed mantle and lower crustal materials, which should have a distinctive compositional signature. We present the analysis of data acquired by GRaND from cruise through the descent to LAMO, including GRaND s sensitivity to different elements and geochemical processes.

Prettyman, Thomas H.↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Neutron Absorption Measurements Constrain Eucrite-Diogenite Mixing in Vesta's Regolith

The NASA Dawn Mission s Gamma Ray and Neutron Detector (GRaND) [1] acquired mapping data during 5 months in a polar, low altitude mapping orbit (LAMO) with approx.460-km mean radius around main-belt asteroid Vesta (264-km mean radius) [2]. Neutrons and gamma rays are produced by galactic cosmic ray interactions and by the decay of natural radioelements (K, Th, U), providing information about the elemental composition of Vesta s regolith to depths of a few decimeters beneath the surface. From the data acquired in LAMO, maps of vestan neutron and gamma ray signatures were determined with a spatial resolution of approx.300 km full-width-at-half-maximum (FWHM), comparable in scale to the Rheasilvia impact basin (approx.500 km diameter). The data from Vesta encounter are available from the NASA Planetary Data System. Based on an analysis of gamma-ray spectra, Vesta s global-average regolith composition was found to be consistent with the Howardite, Eucrite, and Diogenite (HED) meteorites, reinforcing the HED-Vesta connection [2-7]. Further, an analysis of epithermal neutrons revealed variations in the abundance of hydrogen on Vesta s surface, reaching values up to 400 micro-g/g [2]. The association of high concentrations of hydrogen with equatorial, low-albedo surface regions indicated exogenic delivery of hydrogen by the infall of carbonaceous chondrite (CC) materials. This finding was buttressed by the presence of minimally-altered CC clasts in howardites, with inferred bulk hydrogen abundances similar to that found by GRaND, and by studies using data from Dawn s Framing Camera (FC) and VIR instruments [8-10]. In addition, from an analysis of neutron absorption, spatial-variations in the abundance of elements other than hydrogen were detected [2].

Prettyman, T. H.↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

A Solar Aspect System for the HEROES Mission

A new Solar Aspect System (SAS) has been developed to provide the ability to observe the Sun on an existing balloon payload HERO (short for High Energy Replicated Optics). Developed under the HEROES program (High Energy Replicated Optics to Explore the Sun), the SAS aspect system provides solar pointing knowledge in pitch, yaw, and roll. The required precision of these measurements must be better than the HEROES X-ray resolution of approximately 20 arcsec Full Width at Half Maximum (FWHM) so as to not degrade the image resolution. The SAS consists of two separate systems: the Pitch-Yaw Aspect System (PYAS) and the Roll Aspect System (RAS). The PYAS functions by projecting an image of the Sun onto a screen with precision fiducials. A CCD camera takes an image of these fiducials, and an automated algorithm determines the location of the Sun as well as the location of the fiducials. The spacing between fiducials is unique and allows each to be identified so that the location of the Sun on the screen can be precisely determined. The RAS functions by imaging the Earth's horizon in opposite directions using a silvered prism imaged by a CCD camera. The design and first results of the performance of these systems during the HEROES flight which occurred in September 2013 are presented here.

HEROES↗