Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Atomistic‐Level Effects of Noncovalent Interactions and Crystalline Packing for Organic Material Structural Integrity upon Exposure to Gamma Radiation

Developing an atomistic understanding of ionizing radiation induced changes to organic materials is necessary for intentional design of greener and more sustainable materials for radiation shielding and detection. Cocrystals are promising for these purposes, but a detailed understanding of how the specific intermolecular interactions within the lattice upon exposure to radiation affect the structural stability of the organic crystalline material is unknown. This study evaluates atomistic-level effects of γ radiation on both single- and multicomponent organic crystalline materials and how specific noncovalent interactions and packing within the crystalline lattice enhance structural stability. Dose studies were performed on all crystalline systems and evaluated via experimental and computational methods. Changes in crystallinity were evaluated by p-XRD and free radical formation was analyzed via EPR spectroscopy. Type of intermolecular interactions and packing within the crystal lattice was delineated and related to the specific free radical species formed and the structural integrity of each material. Periodic DFT and HOMO-LUMO surface mapping calculations provided atomistic-level identifications of the most probable sites for the radicals formed upon exposure to γ radiation and relate intermolecular interactions and molecular packing within the crystalline lattice to experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Changes in Molten Salt Fuel and/or Waste Stream Compounds Cs 2 UCl 6 and Cs 2 UO 2 Cl 4 from Room Temperature to Melting and Related Materials [Slides]

Perovskite phases have been explored in recent literature as waste forms for long term storage of radioactive waste from molten salt reactors specifically. Synthesis of new halide perovskite phases can inform these efforts as well as molten salt reactor chemistry in general. Inorganic perovskites have also shown promise as new scintillating materials for detection of X-rays and gamma rays. Modifying the structure and chemistry of these compounds, perhaps with organic components, could be used to synthesize new scintillating compounds or modify the properties of existing ones. Both U 6+ and U 4+ readily form compounds with a striking similarity to vacancy ordered perovskites (Cs 2 UO 2 Cl 4 and Cs 2 UCl 6 ). Each of these compounds is relevant to molten salt reactor chemistry and/or waste streams. These phases could from in uranium chloride salt systems or waste streams: Cs being a fission product.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Unified Model of Kilonovae and Gamma-Ray Bursts in Binary Mergers Establishes Neutron Stars as the Central Engines of Short GRBs

We expand the theoretical framework by O. Gottlieb et al., which connects binary merger populations with long and short binary gamma-ray bursts (lbGRBs and sbGRBs, respectively), incorporating kilonovae (KNe) as a key diagnostic tool. We show that lbGRBs, powered by massive accretion disks around black holes (BHs), should be accompanied by bright, red KNe. In contrast, sbGRBs—if also powered by BHs—would produce fainter, red KNe, potentially biasing against their detection. However, magnetized hypermassive neutron star (HMNS) remnants that precede BH formation can produce jets with power (P NS ≈ 10 51 erg s –1 ) and Lorentz factor (Γ > 10) likely compatible with sbGRB observations, and would result in distinctly bluer KNe, offering a pathway to identifying the sbGRB central engine. Recent modeling by J. C. Rastinejad et al. found luminous red KNe consistently accompany lbGRBs, supporting their origin in BH-massive disk systems, likely following a short-lived HMNS phase. The preferential association of sbGRBs with comparably luminous KNe argues against the BH engine hypothesis for sbGRBs, while the bluer hue of these KNe provides additional support for an HMNS-driven mechanism. Within this framework, BH–NS mergers likely contribute exclusively to the lbGRB population with red KNe. Our findings suggest that GW170817 may, in fact, have been an lbGRB to on-axis observers. Finally, we discuss major challenges faced by alternative lbGRB progenitor models, such as white dwarf–NS or white dwarf–BH mergers and accretion-induced collapse forming magnetars, which fail to align with observed GRB timescales, energies, and KN properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-energy 23 Al β-delayed proton decay and 22 Na destruction in novae

The radionuclide 22 Na is a target of γ-ray astronomy searches, predicted to be produced during thermonuclear runaways driving classical novae. The 22 Na (p, γ) 23 Mg reaction is the main destruction channel of 22 Na during a nova, hence, its rate is needed to accurately predict the 22 Na yield. However, experimental determinations of the resonance strengths have led to inconsistent results. In this Rapid Communication, we report a measurement of the branching ratios of the 23 Al β-delayed protons as a probe of the key 204-keV (center-of-mass) 22 Na (p, γ) 23 Mg resonance strength. We report a factor of 5 lower branching ratio compared to the most recent literature value. The variation in 22 Na yield due to nuclear data inconsistencies was assessed using a series of hydrodynamic nova outburst simulations and has increased to a factor of 3.8, corresponding to a factor of ≈ 2 uncertainty in the maximum detectability distance. Finally, this is the first reported scientific measurement using the Gaseous Detector with Germanium Tagging system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery and Timing of Three Millisecond Pulsars in Radio and Gamma-Rays with the Giant Metrewave Radio Telescope and Fermi Large Area Telescope

In this work, we performed deep observations to search for radio pulsations in the directions of 375 unassociated Fermi Large Area Telescope γ-ray sources using the Giant Metrewave Radio Telescope (GMRT) at 322 and 607 MHz. In this paper we report the discovery of three millisecond pulsars (MSPs), PSR J0248+4230, PSR J1207–5050, and PSR J1536–4948. We conducted follow-up timing observations for ~5 yr with the GMRT and derived phase-coherent timing models for these MSPs. PSR J0248+4230 and J1207–5050 are isolated MSPs having periodicities of 2.60 ms and 4.84 ms. PSR J1536–4948 is a 3.07 ms pulsar in a binary system with an orbital period of ~62 days about a companion of a minimum mass of 0.32 M⊙. We also present multifrequency pulse profiles of these MSPs from the GMRT observations. PSR J1536–4948 is an MSP with an extremely wide pulse profile having multiple components. Using the radio timing ephemeris we subsequently detected γ-ray pulsations from these three MSPs, confirming them as the sources powering the γ-ray emission. For PSR J1536–4948 we performed combined radio–γ-ray timing using ~11.6 yr of γ-ray pulse times of arrival (TOAs) along with the radio TOAs. PSR J1536–4948 also shows evidence for pulsed γ-ray emission out to above 25 GeV, confirming earlier associations of this MSP with a ≥10 GeV point source. The multiwavelength pulse profiles of all three MSPs offer challenges to models of radio and γ-ray emission in pulsar magnetospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Examining Nuisance Aerosol Detections in Light of the Origin of the Screening Process (November 2021)

The evolution of philosophy and computations in the International Data Center (IDC) related to aerosol samples have had profound impacts on the number of recorded detections in the network since routine operations began in 2000. Key decisions from policymakers have been the list of triggering radionuclides, the scheme for categorizing these into interest levels 1-5, and an algorithm for determining when an anthropogenic isotope is seen so often that it is no longer interesting, known as the Exponential Weighted Moving Average (EWMA). These are described in the Operations Manual of the IDC. Key parameters that are controlled by the IDC but for which the IDC receives occasional input from policymakers include the constants in EWMA and the peak significance threshold for individual gamma rays, the latter of which directly leads to determination of the presence or absence of a radionuclide in a sample. There are also changes in computations which the IDC makes and informs policy makers about, such as changes in how background is computed, which could also affect the ease of detecting a peak – real or false. Rather than focus on the quantitative changes due to computation changes, this work records some thinking on how isotopes and peak significance levels were chosen, and the resulting detections seen over 18 years during the buildup of the International Monitoring System (IMS). These detections are considered on a global scale to try to determine the relative impact on monitoring, and in some cases, the nature of their existence. Repeated detections of 131I and 133I are the most troublesome, but they are not so frequent to be a major problem for the Verification Regime. These detections could probably be handled adequately using scientific methods currently under development for xenon backgrounds. It is also somewhat problematic that top-level analysis of aerosol backgrounds has not been reported previous to this. The steep increase in the rate of detections after 2016 are a concern, either in the actual backgrounds or from changes in the calculations methods used to generate the Reviewed Radionuclide Report (RRR.) Final conclusions of the authors are that the computational stability of the RRR is very important. With computational stability, changes can be usefully analyzed as being due to changes in radioactivity in Earth’s atmosphere This report is a distillation into text of a talk given in the Radionuclide Experts Group (RNEG) in Vienna during Working Group B (WGB) in February of 2019. This report does not directly contain any IDC data, only summaries by year, or by isotope, or by location. No specific IDC detection by time, location, or isotope is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of cosmic ray impact on transmon qubits with different materials through fast decay detection at Fermilab’s SQMS laboratory

Noise sources affecting superconducting qubits, such as cosmic rays and ambient gamma radiation, have garnered attention for their potential impact. These radiations deposit energy in the qubit's substrate, generating high-energy phonons that break Cooper pairs, leading to the formation of quasi-particles. When these quasi-particles tunnel across Josephson junctions, they induce qubit de-excitation, causing relaxation errors. In this study, we employ a fast feedback mechanism for performing qubit reset to detect decay events with high time resolution. This capability along with frequency multiplexed readout allows us to explore error correlations across time and space. Transmon qubits, manufactured within the Superconducting Quantum Materials and Systems (SQMS) center [1], are investigated at the above-ground lab. We study the impact of cosmic rays on qubits with different encapsulations, geometries, and locations on the same or different chips. We present preliminary findings and discuss the implications for the performance of contemporary quantum hardware.

Roy, Tanay↗

The X-Ray Luminosity Function Evolution of Quasars and the Correlation between the X-Ray and Ultraviolet Luminosities

We explore the evolution of the X-ray luminosity function of quasars and the intrinsic correlation between the X-ray and 2500 Å ultraviolet luminosities, utilizing techniques verified in previous works and a sample of over 4000 quasars detected with Chandra and XMM-Newton in the range 0 < z < 5. We find that quasars have undergone significantly less evolution with redshift in their total X-ray luminosity than in other wave bands. We then determine that the best-fit intrinsic power-law correlation between the X-ray and ultraviolet luminosities, of the form ${L}_{{\rm{X}}}^{{\prime} }\propto {({L}_{\mathrm{UV}}^{{\prime} })}^{\gamma }$, is γ = 0.28 ± 0.03, and we derive the luminosity function and density evolution in the X-ray band. We discuss the implications of these results for models of quasar systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Study of Quasi-Particle Burst Events in Transmon Qubits made with Different Materials and Geometries

Superconducting qubits are susceptible to various noise sources, including cosmic rays. ambient gamma and infrared radiation, which can significantly impact their performance. High-energy radiations deposit energy into the qubit substrate, generating high-energy phonons that disrupt Cooper pairs and create quasi-particles (QPs). Infrared photons, on the other hand can directly create QPs. The tunneling of these quasi-particles across Josephson junctions leads to qubit de-excitation and causes relaxation errors. In this study, we utilize a fast feedback mechanism for qubit reset to detect QP burst events with high time resolution [1]. We investigate transmon qubits fabricated with different encapsulations [2], geometries, and substrates at the above-ground laboratory of the Superconducting Quantum Materials and Systems (SQMS) center at Fermilab. Our preliminary results are presented, with discussions on their implications for the performance of modern quantum hardware. [1] Dominicis and Roy et al.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Natural attenuation of uranium in a fluvial Wetland: Importance of hydrology and speciation

A nuclear fuel fabrication facility released 43,500 kg of uranium into a riparian wetland located on the Savannah River Site between 1955 and 1988. Studies were undertaken to evaluate hydrological and geochemical processes influencing uranium accumulation in the wetland. Gamma-radiation-mapping surveys were conducted by systematically walking over the contaminated wetland with backpacks equipped with global positioning systems and NaI gamma detectors. Based on maps compiled from >700,000 gamma spectra and eight sediment uranium depth profiles, it was determined that 94% of the released uranium remained in the wetland. The uranium in the wetland is concentrated in five multi-hectare areas along the stream, accounting for ~11% of the land area adjacent to the stream. While land type (upland or wetland) and topography provided a reasonable first approximation of where much of the uranium was deposited, hydrological watershed modeling revealed that the stream velocity was especially slow through many of the hot spots. Here, using autoradiography combined with SEM/EDX measurements of contaminated sediments, surprisingly few hot particles were detected. Instead, uranium was evenly distributed throughout the sampled sediment, suggesting that dissolved uranium had bound to sediment particles that became suspended and later deposited in low energy (low flow velocity) portions of the stream. EXAFS suggested that U atoms were present as individual ions in disordered complexes within the sediment. Furthermore, linear combination analyses suggested that the predominant component of the U(VI) was adsorbed to sediment minerals (~70%) and a minor component (~30%) was associated with organic matter phases. Furthermore, these studies show that wetlands can be extraordinarily effective at binding and retaining uranium, thereby providing a natural barrier to the transport of uranium out of a watershed. However, significant anthropogenic or climatic changes to wetlands, such as those associated with flooding, forest fires, or land use, may disrupt the complex hydrological and biogeochemical balance necessary to maintain long-term immobilization of uranium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗