Search NASA⌕ Search

SEARCH · Search NASA

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-439: Fundamental Verification of Respiratory-Gated Spot Scanning Proton Beam Therapy

Purpose: The spot-scanning proton beam irradiation with respiratory gating technique provides quite well dose distribution and requires both dosimetric and geometric verification prior to clinical implementation. The purpose of this study is to evaluate the impact of gating irradiation as a fundamental verification. Methods: We evaluated field width, flatness, symmetry, and penumbra in the gated and non-gated proton beams. The respiration motion was distinguished into 3 patterns: 10, 20, and 30 mm. We compared these contents between the gated and non-gated beams. A 200 MeV proton beam from PROBEAT-III unit (Hitachi Co.Ltd) was used in this study. Respiratory gating irradiation was performed by Quasar phantom (MODUS medical devices) with a combination of dedicated respiratory gating system (ANZAI Medical Corporation). For radiochromic film dosimetry, the calibration curve was created with Gafchromic EBT3 film (Ashland) on FilmQA Pro 2014 (Ashland) as film analysis software. Results: The film was calibrated at the middle of spread out Bragg peak in passive proton beam. The field width, flatness and penumbra in non-gated proton irradiation with respiratory motion were larger than those of reference beam without respiratory motion: the maximum errors of the field width, flatness and penumbra in respiratory motion of 30 mm were 1.75% and 40.3% and 39.7%, respectively. The errors of flatness and penumbra in gating beam (motion: 30 mm, gating rate: 25%) were 0.0% and 2.91%, respectively. The results of symmetry in all proton beams with gating technique were within 0.6%. Conclusion: The field width, flatness, symmetry and penumbra were improved with the gating technique in proton beam. The spot scanning proton beam with gating technique is feasible for the motioned target.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-04: Optimized Respiratory Gating for Abnormal Breathers in Pancreatic SBRT

Purpose: Pancreatic SBRT is uniquely challenging due to both the erratic/unstable motion of the pancreas and the close proximity of the radiosensitive small bowel. Respiratory gating can mitigate this effect, but the irregularity of motion severely affects traditional phase-based gating. The purpose of this study was to analyze real-time motion data of pancreatic tumors to optimize the efficacy and accuracy of respiratory gating, with the overall goal of enabling dose escalated pancreatic SBRT. Methods: Fifteen pancreatic SBRT patients received 30–33 Gy in 5 fractions on a Varian TrueBeam STx unit. Abdominal compression was used to reduce the amplitude of tumor motion, and daily cone-beam computed tomography (CBCT) scans were acquired prior to each treatment for target localization purposes. For this study, breathing data (phase and amplitude) were collected during each CBCT scan using Varian’s Real-Time Position Management system. An in-house template matching technique was used to track the superior-inferior motion of implanted fiducial markers in CBCT projection images. Using tumor motion and breathing data, phase-based or amplitude-based respiratory gating was simulated for all 75 fractions, targeting either end-exhalation or end-inhalation phases of breathing. Results: For the average patient, gating at end-exhalation offered the best reductions in effective motion for equal duty cycles. However, optimal central phase angle varied widely (range: 0–92%, mean±SD: 49±12%), and phase-based gating windows typically associated with end-exhalation (i.e., “30–70%”) were rarely ideal. Amplitude-based gating significantly outperformed phase-based gating, with average effective ranges for amplitude-based gating 25% lower than phase-based gating ranges (as much as 73% lower). Amplitude-based gating was consistently better suited to accommodate abnormal breathing patterns. For both phase-based and amplitude-based gating, end-exhalation provided significantly better results than end-inhalation. Conclusion: Amplitude-based gating reliably outperformed phase-based gating, and end-exhalation was more suitable than end-inhalation. These results will be used to guide future dose-escalation trials. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

Characteristics Of Ferroelectric Logic Gates Using a Spice-Based Model

A SPICE-based model of an n-channel ferroelectric field effect transistor has been developed based on both theoretical and empirical data. This model was used to generate the I-V characteristic of several logic gates. The use of ferroelectric field effect transistors in memory circuits is being developed by several organizations. The use of FFETs in other circuits, both analog and digital needs to be better understood. The ability of FFETs to have different characteristics depending on the initial polarization can be used to create logic gates. These gates can have properties not available to standard CMOS logic gates, such as memory, reconfigurability and memory. This paper investigates basic properties of FFET logic gates. It models FFET inverter, NAND gate and multi-input NAND gate. The I-V characteristics of the gates are presented as well as transfer characteristics and timing. The model used is a SPICE-based model developed from empirical data from actual Ferroelectric transistors. It simulates all major characteristics of the ferroelectric transistor, including polarization, hysteresis and decay. Contrasts are made of the differences between FFET logic gates and CMOS logic gates. FFET parameters are varied to show the effect on the overall gate. A recodigurable gate is investigated which is not possible with CMOS circuits. The paper concludes that FFETs can be used in logic gates and have several advantages over standard CMOS gates.

MacLeod, Todd C.↗

Direct pulse-level compilation of arbitrary quantum logic gates on superconducting qutrits

Advanced simulations and calculations on quantum computers require high-fidelity implementations of quantum operations. The universal gateset approach builds complex unitaries from a small set of primitive gates, often resulting in a long gate sequence, which is typically a leading factor in the total accumulated error. Compiling a complex unitary for processors with higher-dimensional logical elements, such as qutrits, exacerbates the accumulated error per unitary, since an even longer gate sequence is required. Optimal control methods promise time- and resource-efficient compact gate sequences and, therefore, higher fidelity. These methods generate pulses that can directly implement any complex unitary on a quantum device. In this work, we demonstrate that any arbitrary qubit and qutrit gate can be realized with high fidelity, which can significantly reduce the length of a gate sequence. We generate and test pulses for a large set of randomly selected arbitrary unitaries on several quantum processing units (QPUs): the Lawrence Livermore National Laboratory Quantum Device and Integration Testbed’s (QuDIT’s) standard QPU and three of Rigetti’s QPUs: Ankaa-2, Ankaa-9Q-1, and Aspen-M-3. On the QuDIT platform’s standard QPU, the average fidelity of random qutrit gates is 97.9 ± 0.5% measured with conventional QPT and 98.8 ± 0.6% from QPT with gate folding. Rigetti’s Ankaa-2 achieves random qubit gates with an average fidelity of 98.4 ± 0.5% (conventional QPT) and 99.7 ± 0.1% (QPT with gate folding). On Ankaa-9Q-1 and Aspen-M-3, the average fidelities with conventional qubit QPT measurements were higher than 99% (see Appendix). Here we show that optimal control gates are robust to drift for at least 3 h and that the same calibration parameters can be used for all implemented gates. Our work promises that the calibration overheads for optimal control gates can be made small enough to enable efficient quantum circuits based on this technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver

Purpose: Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). Methods: A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. Results: The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. Conclusions: Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer’s specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

SU-F-T-634: Feasibility Study of Respiratory Gated RapidArc SBRT Using a 6MV FFF Photon Beam

Purpose: To conduct a feasibility study on retrospective respiratory gating and marker tracking for lung stereotactic body radiotherapy (SBRT) with a gated RapidArc delivery using a 6MV flattened filter free photon mode. Methods: A CIRS dynamic thorax phantom Model 008A with different inserts was used for treatment planning and respiratory gating. 4D CT had a free breathing simulation followed by a respiration gated, ten phased CT using a Philips Brilliance CT with a Varian RPM respiratory gating system. The internal target volume was created from the ten phase gated CT images, followed by exporting to a Varian Eclipse TPS v11 for treatment planning on the free breath images. Both MIP and AIP were also generated for comparison of planning and target motion tracking. The planned dose was delivered with a 6MV FFF photon beam from a Varian TrueBeam accelerator. Gated target motion was also verified by tracking the implanted makers during delivery using continuous kV imaging in addition to CBCT, kV and MV localization and verification. Results: Gating was studied in three situations of lower, normal, and faster breathing at a respiratory cycle of 5, 15 and 25 breaths per minute, respectively. 4D treatment planning was performed at a normal breathing of 15 breaths per minute. The gated patterns obtained using the TrueBeam IR camera were compared with the planned ones while gating operation was added prior to delivery . Gating was realized only when the measured respiratory patterns matched to the planned ones. The gated target motion was verified within the tolerance by kV and MV imaging. Either free breathing CT or averaged CT images were studied to be good for image guidance to align the target. Conclusion: Gated RapidArc SBRT delivered with a 6MV FFF photon beam is realized using a dynamic lung phantom.

60 APPLIED LIFE SCIENCES↗

Few-mode and anisotropic quantum transport in InSb nanoribbons using an all-van der Waals material-based gate

High-quality electrostatic gating is a fundamental ingredient for successful semiconducting device physics, and a key element of realizing clean quantum transport. Inspired by the widespread improvement of transport quality when two-dimensional van der Waals (vdW) materials are gated exclusively by other vdW materials, we have developed a method for gating non-vdW materials with an all-vdW gate stack, consisting of a hexagonal boron nitride dielectric layer and a few-layer graphite gate electrode. We demonstrate this gating approach on MOVPE-grown InSb nanoribbons (NRs), a novel variant of the InSb nanowire, with a flattened cross-section. In our all-vdW gated NR devices we observe conductance features that are reproducible and have low- to near-zero gate hysteresis. We also report quantized conductance, which persists to lower magnetic fields and longer channel lengths than typical InSb nanowire devices reported to date. Additionally, we observe level splitting that is highly anisotropic in an applied magnetic field, which we attribute to the ribbon cross-section. The performance of our devices is consistent with the reduced disorder expected from the all-vdW gating scheme, and marks the first report of ballistic, few-modes quantum transport in a non-vdW material with an all-vdW gate. Our results establish all-vdW gating as a promising approach for high-quality gating of non-vdW materials for quantum transport, which is in principle applicable generically, beyond InSb systems. In addition, the work showcases the specific potential of all-vdW gate/InSb NR devices for enabling clean quantum devices that may be relevant for spintronics and topological superconductivity studies.

InSb↗

SU-F-J-151: Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film

Purpose: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on target position for soft-tissue targets in the lung and abdomen. We present a dosimetric evaluation of a commercially-available FDA-approved MRI-guided radiotherapy system’s gating performance using a MRI-compatible respiratory motion phantom and radiochromic film. Methods: The MRI-compatible phantom was capable of one-dimensional motion. The phantom consisted of a target rod containing high-contrast target inserts which moved inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical target, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal and actual tumor trajectories (two free-breathing trajectories and one repeated-breath hold) were used. Gamma comparison at 5%/3mm was used to measure fidelity to the static target dose distribution. Results: Without gating, gamma pass rates were 24–47% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% of the target allowed outside the gating boundary, the gamma pass rate was 99.6%. Relaxing the gating window to 5 mm resulted in gamma pass rate of 98.6% with repeated breath holds. For all motion trajectories gated with 3 mm margin and 10% allowed out, gamma pass rates were between 64–100% (mean:87.5%). For a 5 mm margin and 10% allowed out, gamma pass rates were between 57–98% (mean: 82.49%), significantly lower than for 3 mm by paired t-test (p=0.01). Conclusion: We validated the performance of respiratory gating based on real-time cine MRI images with the only FDA-approved MRI-guided radiotherapy system. Our results suggest that repeated breath hold gating should be used when possible for best accuracy. A 3 mm gating margin is statistically significantly more accurate than a 5 mm gating margin.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-03: A Novel Method for Characterizing Gating Response Time in Radiation Therapy

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Current film based methods to assess gating response have poor temporal resolution and are highly qualitative. We describe a novel method to precisely measure gating lag times at high temporal resolutions and use it to characterize the temporal response of several gating systems. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz (0.4 millisecond (ms) sampling interval) with an analogue-to-digital converter (ADC). The techniques was used on three commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted using a polynomial fit method. Results: A Varian RPM system with a monoscopic IR camera was measured to have mean beam ON and OFF lag times of 98.2 ms and 89.6 ms, respectively. A Varian RPM system with a stereoscopic IR camera was measured to have mean beam ON and OFF lag times of 86.0 ms and 44.0 ms, respectively. A Calypso magnetic fiducial tracking system was measured to have mean beam ON and OFF lag times of 209.0 ms and 60.0 ms, respectively. Conclusions: A novel method allowed for quantitative determination of gating timing accuracy for several clinically used gating systems. All gating systems met the 100 ms TG-142 criteria for mean beam OFF times. For beam ON response, the Calypso system exceeded the recommended response time.

60 APPLIED LIFE SCIENCES↗

Study of implosion dynamics, the x-ray yield and plasma interpenetration in star wire arrays with gates in the inner cylinder.

Star wire arrays with two closely located wires ('gates') on the inner cylinder of star wire arrays were studied. The gate wires were used to study plasma interpenetration and reproduce transparent and non-transparent regimes of propagation of the imploding plasma through the gates. The non-transparent mode of collision is typical for regular star wire arrays and it was also observed in Al stars with gate wires of regular length. Gated star arrays demonstrate similar x-ray yield but slightly different delay of x-ray generation compared to regular stars. Double length wires were applied as gate wires to increase their inductance and resistance and to increase transparency for the imploding plasma. The wires of the gates were made of Al or high atomic number elements, while the rest of the arrays were regular length Al wires. An intermediate semi-transparent mode of collision was observed in Al stars with long Al gate wires. Arrays with long heavy-element gate wires demonstrated transparency to plasma passing through. Shadowgraphy at the wavelength of 266 nm showed that plasma moved through the gate wires. Double implosions, generating a double-peak keV X-ray pulse, were observed in star arrays when the gates were made of high atomic number elements. A new laser diagnostic beampath for vertical probing of the Z-pinch was built to test how wires could be used to redirect plasma flow. This setup was designed to test gated arrays and further configurations to create a rotating pinch. Results on plasma flow control obtained are discussed, and compared to numerical calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multitarget Rydberg gates via spatial blockade engineering

Multi-target gates offer the potential to reduce gate depth in syndrome extraction for quantum error correction. Although neutral-atom quantum computers have demonstrated native multi-qubit gates, existing approaches that avoid additional control or multiple atomic species have been limited to single-target gates. We propose single-control-multi-target CZ^n gates on a single-species neutral-atom platform that require no extra control and have gate durations comparable to standard CZ gates. Our approach leverages tailored interatomic distances to create an asymmetric blockade between the control and target atoms. Using a GPU-accelerated pulse synthesis protocol, we design smooth control pulses for CZZ and CZZZ gates, achieving fidelities of up to 99.55% and $99.24\%$, respectively, even in the presence of simulated atom placement errors and Rydberg-state decay. Our approach is most effective for N=2 (CZZ) and N=3 targets (CZZZ); for larger N, increasing spatial crowding of the targets introduces significant challenges for maintaining the required blockade asymmetry. This work presents a practical path to implementing low-overhead multi-target gates in single-species neutral-atom systems, significantly reducing the resource overhead for syndrome extraction. To motivate the impact of these gates, we apply a greedy scheduling algorithm and we demonstrate that our proposed gates can reduce the number of atom reconfiguration costs by up to 50% for color code syndrome extraction of code distances greater than 5.

Stein, Samuel A.↗

SU-F-T-518: Development and Characterization of a Gated Treatment System Implemented with An In-House Optical Tracking System and the Elekta Response Interface

Purpose: To report the development and characterization of the first in-house gating system implemented with an optical tracking system (OTS) and the Elekta Response™ interface. Methods: The Response™ connects a patient tracking system with a linac, enabling the tracking system to control radiation delivery. The developed system uses an in-house OTS to monitor patient breathing. The OTS consists of two infrared-based cameras, tracking markers affixed on patient. It achieves gated or breath-held (BH) treatment by calling beam ON/OFF functions in the Response™ dynamic-link library (DLL). A 4D motion phantom was used to evaluate its dosimetric and time delay characteristics. Two FF- and two FFF-IMRT beams were delivered in non-gated, BH and gated mode. The sinusoidal gating signal had a 6 sec period and 15 mm amplitude. The duty cycle included 10%, 20%, 30% and 50%. The BH signal was adapted from the sinusoidal wave by inserting 15 sec BHs. Each delivery was measured with a 2D diode array (MapCHECK™) and compared with the non-gated delivery using gamma analysis (3%). The beam ON/OFF time was captured using the service graphing utility of the linac. Results: The gated treatments were successfully delivered except the 10% duty cycle. The BH delivery had perfect agreement (100%) with non-gated delivery; the agreement of gated delivery decreased from 99% to 88% as duty cycle reduced from 50% to 20%. The beam on/off delay was on average 0.25/0.06 sec. The delivery time for the 50%, 30% and 20% duty cycle increased by 29%, 71% and 139%, respectively. No dosimetric or time delay difference was noticed between FF- and FFF-IMRT beams. Conclusion: The in-house gating system was successfully developed with dosimetric and time delay characteristics in line with published results for commercial systems. It will be an important platform for further research and clinical development of gated treatment.

43 PARTICLE ACCELERATORS↗

Computer Simulation Studies of Ion Channel Gating: Characteristics of the M2 Channel of Influenza-A Virus in a Phospholipid Bilayer

The 25 amino acids long, transmembrane fragment of the Influenza virus M2 protein forms a homotetrameric channel that transports protons across lipid bilayers. It has been postulated that high efficiency and selectivity of this process is due to gating by four histidine residues that occlude the channel lumen in the closed state. Two mechanisms of gating have been postulated. In one mechanism, the proton is "shuttled" through the gate by attaching to the delta nitrogen atom on the extracellular side of the imidazole ring, followed by the release of the proton attached to the epsilon nitrogen atom on the opposite side. In the second mechanism, the four histidines move away from each other due to electrostatic repulsion upon protonation, thus opening the gate sufficiently that a wire of water molecules can penetrate the gate. Then, protons are transported by "hopping" along the wire. In this paper, both mechanisms are evaluated in a series of molecular dynamics simulations by investigating stability of different protonation states of the channel that are involved in these mechanisms. For the shuttle mechanism, these are states with all epsilon protonated histidines, one biprotonated residue or one histidine protonated in the delta position. For the gate opening mechanism, this is the state in which all four histidines are biprotonated. In addition, a state with two biprotonated histidines is considered. For each system, composed of the protein channel embedded in phospholipid bilayer located between two water lamellae, a molecular dynamics trajectory of approximately 1.3 ns (after equilibration) was obtained. It is found that the states involved in the shuttle mechanism are stable during the simulations. Furthermore, the orientations and dynamics of water molecules near the gate are conducive to proton transfers involved in the shuttle. In contract, the fully biprotonated state, implicated in the gate opening mechanism, is not stable and the channel looses its structural integrity. If only two histidines are biprotonated the channel deforms but remains intact with the gate mostly closed. In summary, the results of this study lend support to the shuttle mechanism but not to the gate opening mechanism of proton gating in M2.

Schweighofer, Karl J.↗

Organic thin-film transistors with a bottom bilayer gate dielectric having a low operating voltage and high operational stability

This study reports on p-channel bottom-gate organic thin-film transistors (OTFT) that achieve low-voltage operation with a thin bilayer gate dielectric of CYTOP/HfO 2 that also leads to high operational stability. A bottom-gate geometry allows the thickness of the gate dielectric to be reduced to 17 nm, thereby increasing the gate dielectric capacitance density to a value of up to 258 nF/cm 2 . All OTFTs yielded threshold voltages (V TH ) lower than -1 V, thereby providing minimum operating voltage (gate to source voltage ~ V TH ) of -1 V with field-effect mobility values in the range from 0.3 to 0.8 cm 2 /Vs and subthreshold swing values below 100 mV/dec. Operational stability during DC bias stress was found similar to that measured in devices with a top-gate geometry, with about 1% of drain current change after 6 h. Here, using a double-stretched exponential function, the operational stability characteristics were modeled. It was found that by increasing the metal oxide layer thickness, the threshold voltage can shift toward positive values under DC stress tests. For CYTOP layer thicknesses above 15 nm, a thicker CYTOP layer was found to shift the threshold voltage in the opposite direction toward negative values. Furthermore, these p-channel bottom-gate organic transistor with a bilayer gate dielectric of CYTOP/HfO 2 combine high mobility, high operational stability, and lower voltage operation of -1 V compared to top-gate OTFTs.

36 MATERIALS SCIENCE↗

Quantum computation of frequency-domain molecular response properties using a three-qubit iToffoli gate

The quantum computation of molecular response properties on near-term quantum hardware is a topic of substantial interest. Computing these properties directly in the frequency domain is desirable, but the circuits require large depth if the typical hardware gate set consisting of single- and two-qubit gates is used. While high-fidelity multipartite gates have been reported recently, their integration into quantum simulation and the demonstration of improved accuracy of the observable properties remains to be shown. Here, we report the application of a high-fidelity multipartite gate, the iToffoli gate, to the computation of frequency-domain response properties of diatomic molecules. The iToffoli gate enables a ~50% reduction in circuit depth and ~40% reduction in circuit execution time compared to the traditional gate set. We show that the molecular properties obtained with the iToffoli gate exhibit comparable or better agreement with theory than those obtained with the native CZ gates. Our work is among the first demonstrations of the practical usage of a native multi-qubit gate in quantum simulation, with diverse potential applications to near-term quantum computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗