Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Design, Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) v0.1.0

The DISPATCHES software will enable the design and optimization of Integrated Energy Systems (IES). The platform will support hybridizing existing generation facilities (such as nuclear and coal plants) as well as greenfield hybrid designs that incorporate advanced technologies (such as Advanced Modular Reactors and Coal FIRST), and it will enable the consideration of multiple technology options with different time constants. The design of the IES will be optimized for operation within the bulk power system via energy market signals (day ahead, real-time, and ancillary services) obtained from a production cost model. The goal of DISPATCHES is to identify flexible, dynamic designs that are responsive to grid market signals resulting in highly efficient, cost effective tightly coupled hybrid energy systems that can act as a "black box" to the grid to provide increased flexibility and resiliency.

Gunter, Daniel↗

Stochastic Virtual Battery Modeling of Uncertain Electrical Loads using Variational Autoencoder

Effective utilization of flexible loads for grid services, while satisfying end-user preferences and constraints, requires an accurate estimation of the aggregated predictive flexibility offered by the electrical loads. Recently, there have been efforts to quantify the predictive flexibility of thermostatic loads (e.g. residential air-conditioners, electric water-heaters) using the notion of virtual battery (VB), whose state evolution is governed by a first order dynamics including self-dissipation rate, and power and energy capacities. Identifying the VB model parameters for a collection of thermostatic loads, however, is challenging primarily due to uncertainties and lack of information regarding the end-user behavior, underlying device models and parameters. In this paper, we propose a \textit{variational autoencoder}-based deep learning algorithm to identify the parameters of the VB model. Using available sensors and meters data, the proposed algorithm generates not only point estimates of the VB parameters, but also confidence intervals around those values. Effectiveness of the proposed frameworks is demonstrated on a collection of electric water-heater loads, whose operation is driven by uncertain water usage profiles.

virtual battery, deep learning algorithms↗

Hydropower Resilience Database for Assessing Microgrid Formation Capability and Enhancing Power Grid Resilience

In the face of increasing frequency of extreme events, enhancing resilience and reliability of energy infrastructure demands innovative solutions. Hydropower, with its inherent generation flexibility and grid-forming capability, offers significant potential for enhancing power grid resilience through the establishment of microgrids. To enable informed decision-making and strategic planning, we present the Hydropower Resilience Database (HRD) that integrates data from various sources such as Oakridge National Laboratory (ORNL) HydroSource, National Inventory of Dams, and US Western Grid database. By integrating relevant information on hydropower plant characteristics, including dams, reservoirs, and connected electrical grid, this resource enables hydropower plant owners, utilities, and community stakeholders to identify and evaluate the feasibility of using hydropower resources in microgrids to support nearby communities and critical infrastructure in various challenging scenarios. Using HRD, a set of metrics are evaluated to quantify the capability of hydropower plants to support essential microgrid functions. An interactive tool is developed using ArcGIS, enabling the visualization and analysis using HRD. Our research contributes to strategic planning efforts for fortifying energy infrastructure, ensuring reliable power supply during disruptions, and advancing the development of robust and resilient energy systems in regions susceptible to grid vulnerabilities.

13 HYDRO ENERGY↗

Hydropower Resilience Database for Assessing Microgrid Formation Capability and Enhancing Power Grid Resilience

In the face of increasing frequency of extreme events, enhancing resilience and reliability of energy infrastructure demands innovative solutions. Hydropower, with its inherent generation flexibility and grid-forming capability, offers significant potential for enhancing power grid resilience through the establishment of microgrids. To enable informed decision-making and strategic planning, we present the Hydropower Resilience Database (HRD) that integrates data from various sources such as Oakridge National Laboratory (ORNL) HydroSource, National Inventory of Dams, and US Western Grid database. By integrating relevant information on hydropower plant characteristics, including dams, reservoirs, and connected electrical grid, this resource enables hydropower plant owners, utilities, and community stakeholders to identify and evaluate the feasibility of using hydropower resources in microgrids to support nearby communities and critical infrastructure in various challenging scenarios. Using HRD, a set of metrics are evaluated to quantify the capability of hydropower plants to support essential microgrid functions. An interactive tool is developed using ArcGIS, enabling the visualization and analysis using HRD. Our research contributes to strategic planning efforts for fortifying energy infrastructure, ensuring reliable power supply during disruptions, and advancing the development of robust and resilient energy systems in regions susceptible to grid vulnerabilities.

13 HYDRO ENERGY↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Price Formation in Zero-Carbon Electricity Markets: The Role of Hydropower

In April 2019, Water Power Technologies Office (WPTO) launched the HydroWIRES Initiative to understand, enable, and improve hydropower and pumped storage hydropower’s (PSH’s) contributions to reliability, resilience, and integration in the rapidly evolving U.S. electricity system. The unique characteristics of hydropower, including PSH, make it well suited to provide a range of storage, generation flexibility, and other grid services to support the cost-effective integration of variable renewable resources. The U.S. electricity system is rapidly evolving, bringing both opportunities and challenges for the hydropower sector. While increasing deployment of variable renewables such as wind and solar have enabled low-cost, clean energy in many U.S. regions, it has also created a need for resources that can store energy or quickly change their operations to ensure a reliable and resilient grid. Hydropower (including PSH) is not only a supplier of bulk, low-cost, renewable energy but also a source of large-scale flexibility and a force multiplier for other renewable power generation sources. Realizing this potential requires innovation in several areas: understanding value drivers for hydropower under evolving system conditions, describing flexible capabilities and associated tradeoffs associated with hydropower meeting system needs, optimizing hydropower operations and planning, and developing innovative technologies that enable hydropower to operate more flexibly.

13 HYDRO ENERGY↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

If One GEB is Good, a Community of GEBs is Better

Energy efficient, connected, grid-interactive, smart and flexible buildings are key to decarbonization, lowering energy use and improving the nation’s electricity grid. The U.S. Department of Energy’s Connected Communities initiative works to demonstrate how coordinated groups of highly efficient buildings combined with other distributed energy resources (DERs), such as electric vehicle (EV) charging, batteries, storage, demand response and photovoltaic (PV) generation can reliably and cost-effectively serve as grid assets by strategically deploying efficiency and demand flexibility while reducing carbon emissions. In 2021, DOE competitively awarded $61 million to a diverse portfolio of 10 pilot projects to promote grid-interactive efficient buildings (GEBs) working together to reliably and cost-effectively serve as grid assets while decarbonizing. Two of the main tenets of the program are measuring the communities’ energy and carbon performance and understanding how to replicate project successes in other communities. This paper begins with a discussion of what Connected Communities are (including a brief history) and their many benefits, including reduced carbon emissions and increased building efficiency and demand flexibility. Next, it provides an overview of the 10 projects, highlighting the diversity of approaches to measure success and replicate the projects: geographic locations; building types; utility, regulatory, market environments; and building vintages that will be used to test the ability of buildings to serve as grid resources. It concludes with a discussion of anticipated project impacts and the metrics that will be used to evaluate the Connected Communities projects.

Nemtzow, David↗

Market optimization and technoeconomic analysis of hydrogen-electricity coproduction systems

Decarbonization efforts across North America, Europe, and beyond rely on variable renewable energy sources such as wind and solar, as well as alternative fuels, such as hydrogen, to support the sustainable energy transition. These advancements have prompted a need for more flexibility in the electric grid to complement non-dispatchable energy sources and increased demand from electrification. Integrated energy systems are well suited to provide this flexibility, but conventional technoeconomic modeling paradigms neglect the time-varying dynamic nature of the grid and thus undervalue resource flexibility. In this work, we develop a computational optimization framework for dynamic market-based technoeconomic comparison of integrated energy systems that coproduce low-carbon electricity and hydrogen (e.g., solid oxide fuel cells, solid oxide electrolysis) against technologies that only produce electricity (e.g., natural gas combined cycle with carbon capture) or only produce hydrogen. Our framework starts with rigorous physics-based process models, built in the open-source Institute for the Design of Advanced Energy Systems (IDAES) modeling and optimization platform, for six energy process concepts. Using these rigorous models and a workflow to optimally design each technology, the framework is shown to be capable of evaluating new and emerging technologies in varying energy markets under a plethora of future scenarios (i.e., renewables penetration, carbon tax, etc.). Ultimately, our framework finds that solid oxide fuel cell-based coproduction systems achieve positive profits for 85% of the analyzed market scenarios. From these market optimization results, we use multivariate linear regression (R 2 values up to 0.99) to determine which electricity price statistics are most significant to predict the optimized annual profit of each system. The proposed framework provides a powerful tool for directly comparing flexible, multi-product energy process concepts to help discern optimal technology and integration options.

08 HYDROGEN↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Shifts in hydropower operation to balance wind and solar will modify effects on aquatic biota

To avoid negative consequences to freshwater biota from climate change, society must complete the transition from fossil to renewable electricity sources. However, temporal patterns in hydropower generation (and flow releases that affect aquatic biota) may change with increased wind and solar penetration. We used power cost modeling to characterize current and future within-day and seasonal patterns in hydropower generation across the Eastern Interconnection in a wet and a dry year. Compared to the baseline, future hydropower generation across the grid decreased during the day and increased before dawn and after dusk. At a project level, such a pattern would suggest 'double peaking' operation (up- and down-ramping before dawn and after dusk, with lower releases midday). Variation in generation was higher in wet years than dry years, foreshadowing possible flow constraints on hydropower flexibility. At the grid scale, projected ramping rates were higher in all seasons. A review of the ecological literature suggests that these changes would shift the timing of invertebrate drift and elevate the risk of nest scouring during up-ramping and the risk of stranding or dewatering during down ramping. Thermal conditions may be moderated by increased ramping. Strategies for adapting to future shifts in the renewable portfolio range from re-regulation in reservoir cascades to providing flow refuge (structures and vegetation) below individual projects. Coordinated basin-scale operation can distribute peaking operation to maintain grid support while restricting local ramping at critical ecological times. In addition, research to design hybrid renewable systems that add battery storage is needed to understand how we can mitigate future risks to aquatic communities while promoting the use of renewable energy. This study, which is among the first to examine ecological side-effects of the shift to renewable energy in freshwater ecosystems, lays out a path toward understanding and navigating changes to flow regimes under the energy transition.

54 ENVIRONMENTAL SCIENCES↗

Optimizing an Integrated Renewable-Electrolysis System

Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. With growing amounts of renewable generation on the California grid, there is downward pressure on wholesale electricity prices, particularly during the afternoon from photovoltaics (PV). These lower, or even potentially negative prices, challenge the business cases for new and existing PV plants. In addition, as the grid transitions to less flexible generation, there is greater need for system flexibility. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. The optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations where PV is already installed. The six market configurations include islanded, separated, retail, net energy metering (NEM), hybrid retail/wholesale and wholesale. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen price over the lifetime of the equipment is calculated. The cost includes production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams include the sale of hydrogen, low carbon fuel standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale rate optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations, the breakeven hydrogen production cost results show that, in the order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). The resulting system design balances between the capital and maintenance cost components, the operation costs (i.e., electricity costs) and the additional market revenues. The integration of solar PV and electrolysis is shown to provide a mutually beneficial relationship. For PV, integration with electrolysis offers the potential to hedge against wholesale market price volatility, and integration with electrolysis may offer the potential to defer or avoid transmission investment to deliver power to the point-of-use and instead use it on-site. When compared with SMR without considering any renewable hydrogen premiums, this study finds that PV + Electrolysis systems with current costs are likely not competitive; however, with cost reductions for electrolysis equipment consistent with DOE projections, it was found that systems with wholesale market access would be competitive, largely on account of both low capital costs and low-cost electricity. The electrolysis units can provide greater flexibility than is required based on retail rate optimization, so there is an opportunity for a utility or CAISO to increase system flexibility with PV + Electrolysis systems in return for commensurate compensation. In this way, there are potentially several solutions that fall between the hybrid configuration and the wholesale configuration that could provide sufficient compensation for a PV + Electrolysis unit to compete with SMR while also providing greater flexibility to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Change Agent: Energy Storage as a Driver of Regulatory Evolution

Purpose of Review Dividing the electric grid into the functions of generation, transmission, anddistribution enabled the drawing of jurisdictional lines and the application of the U.S.Constitution’s federalist system to energy regulation. Energy storage technologies,which can be placed throughout the grid to increase flexibility, can provide serviceacross all three of those functions. But the jurisdictional boundaries that have beendrawn around those functions have created barriers that restrict energy storagetechnologies from achieving their full potential. This review analyzes regulatory changes made to reduce barriers to storage deployment and their broader impacts on energy regulation in the U.S. Recent Findings Major energy regulations promulgated at the state and federal levels have generally focused on liberalizing the U.S. electric system through deregulation and increased competition. Paradoxically, however, these efforts have erected strict regulatory barriers that prevent energy storage technologies from providing service across multiple functions. A new wave of regulations in recent years has endeavored to reduce and remove those barriers. Summary Energy regulations adopted in recent years to reduce barriers to energy storage functionality in recent years have had deep and far-reaching impacts on U.S. electric regulation. These impacts go beyond storage and affect all energy technologies. This paper traces the development of energy regulation in U.S., the functional barriers that they created that impede energy storage functionality, recent efforts to remove those barriers, and the broader effects of those efforts. It concludes with a brief discussion of remaining barriers that prevent energy storage from reaching their full potential on the U.S. electric grid.