Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid simulator testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Adaptive Mesh Refinement (AMR) in a Forced Shallow-Water Model with Moisture

Two forced shallow-water flow scenarios are explored in a 2D fourth-order finite-volume dynamical core with adaptive mesh refinement (AMR) to investigate AMR’s ability to track and resolve complex evolving features. Traditional shallow-water test cases are mainly characterized by large-scale smooth flows that do not effectively test the multiscale abilities of variable-resolution and AMR models to resolve sharp gradients and small-scale flow filaments. Therefore, adding forcing mechanisms to the shallow-water system to model key atmospheric processes adds complexity and creates small-scale phenomena. These can serve as foci for dynamic grid refinement while remaining simple enough to study the numerical design of a model’s dynamical core. The first shallow-water flow scenario represents a strengthening, tropical cyclone–like, vortex that is driven by a Betts–Miller-like convection scheme. The second shallow-water test is built upon a barotropically unstable jet with an added Kessler-like warm rain scheme that leads to precipitating frontal zones. The key feature of both tests is that there is significant sensitivity to the model grid while converging (structurally) at high resolution. Both test cases are investigated for a series of uniform resolutions and a variety of AMR tagging criteria. The AMR simulations demonstrate that grid refinement can resolve local features without requiring global high-resolution meshes. However, the results are sensitive to the refinement criteria. Criteria that trigger refinement early in a simulation reproduce the uniform-resolution reference solutions most reliably. Finally, in contrast, AMR criteria that delay refinement for several days require careful tuning of the AMR thresholds to improve results compared with uniform-resolution simulations.

54 ENVIRONMENTAL SCIENCES↗

Time-Disciplined Non-PLL Active Synchronization for Grid-Forming Inverters: Preprint

Grid Forming Inverters (GFMIs) are a critical component of the future Grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) Initial Grid Synchronization, (2) Ride-Through, (3) Blackstart Coordination, (4) Grid Reconnection Coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper’s framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant Grid.

blackstart↗

Time Disciplined Non-PLL Active Synchronization for Grid Forming Inverters

Grid forming inverters (GFMIs) are a critical component of the future grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) initial grid synchronization, (2) ride-through, (3) blackstart coordination, (4) grid reconnection coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper's framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant grid.

blackstart↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical Start-Up Process of Multiple Grid-Tied Voltage-Sourced Inverters in Laboratory

Starting up inverter-based resources (IBRs) and integrating them into a grid are important in real-world engineering and there are many challenges to be tackled. Using a laboratory-scale hardware test bed (50 Watt and 20 V), this paper demonstrates the challenges and provides a practical start-up process that can smoothly energize two grid-tied voltage-sourced inverters (VSI) and synchronize the VSIs into a 60-Hz grid. The hardware test bed consists of two SiC VSIs and a 45-kW Chroma grid simulator to act as the grid. The inverter controls are implemented in OPAL-RT OP5600, which has the measurements sensed, control algorithms processed, and gate signals generated and sent to the VSI switches. This research focuses on examining how to energize VSIs and how to synchronize the VSIs into the grid. The best energizing approach is summarized based on comparison and analysis of the experiment results. The presented approach can prevent large transients during the start-up process.

Wang, Zhengyu↗

On the Influence of Swell Propagation Angle on Surface Drag

Abstract A combination of turbulence-resolving large-eddy simulations and observations are used to examine the influence of swell amplitude and swell propagation angle on surface drag. Based on the analysis a new surface roughness parameterization with nonequilibrium wave effects is proposed. The surface roughness accounts for swell amplitude and wavelength and its relative motion with respect to the mean wind direction. The proposed parameterization is tested in uncoupled three-dimensional Weather and Research Forecasting (WRF) simulations at grid sizes near 1 km where we explore potential implications of our modifications for two-way coupled atmosphere–wave models. Wind–wave misalignment likely explains the large scatter in observed nondimensional surface roughness under swell-dominated conditions. Andreas et al.’s relationship between friction velocity and the 10-m wind speed under predicts the increased drag produced by misaligned winds and waves. Incorporating wave-state (speed and direction) influences in parameterizations improves predictive skill. In a broad sense, these results suggest that one needs information on winds and wave state to upscale buoy measurements.

54 ENVIRONMENTAL SCIENCES↗

Cholla-MHD: An Exascale-capable Magnetohydrodynamic Extension to the Cholla Astrophysical Simulation Code

Abstract We present an extension of the massively parallel, GPU native, astrophysical hydrodynamics code Cholla to magnetohydrodynamics (MHD). Cholla solves the ideal MHD equations in their Eulerian form on a static Cartesian mesh utilizing the Van Leer + constrained transport integrator, the HLLD Riemann solver, and reconstruction methods at second and third order. Cholla’s MHD module can perform ≈260 million cell updates per GPU-second on an NVIDIA A100 while using the HLLD Riemann solver and second order reconstruction. The inherently parallel nature of GPUs combined with increased memory in new hardware allows Cholla’s MHD module to perform simulations with resolutions ∼500 3 cells on a single high-end GPU (e.g., an NVIDIA A100 with 80 GB of memory). We employ GPU direct Message Passing Interface to attain excellent weak scaling on the exascale supercomputer Frontier, while using 74,088 GPUs and simulating a total grid size of over 7.2 trillion cells. A suite of test problems highlights the accuracy of Cholla’s MHD module and demonstrates that zero magnetic divergence in solutions is maintained to round off error. We also present new testing and CI tools using GoogleTest, GitHub Actions, and Jenkins that have made development more robust and accurate and ensure reliability in the future.

Astronomy & Astrophysics↗

Adaptive Envelope Detector-Based Phase Fault Detection Method for Power System Grid Distortions

In this study, a phase fault detection algorithm is developed by employing the envelope detector method. The proposed method diagnoses faults among phases and defines fault areas in the incoming signal. The designed algorithm consists of three steps: analytical signal conversion, complex magnitude, and fault detection. Initially, an analytical signal is obtained from the incoming power signal to determine the instantaneous amplitude and phase of the signal. A complex magnitude operation is applied to analytical signals to display changes in amplitude. On the basis of the threshold values specified by the user, the last step identifies the distortion signal in terms of the type of error and size. The proposed method is tested with realistically simulated substation power signal data and real power system data from the Grid Event Signature Library. The obtained results revealed that the proposed method detects distortions accurately.

Alaca, Ozgur↗

V1G Frequency Regulation: Algorithm Development, Validation & Analysis at Scale

Researchers at Argonne National Laboratory developed and validated a high-fidelity digital twin of a smart charging (V1G) ecosystem to model the participation of up to 1,000 unique electric vehicles (EVs) in the PJM frequency regulation market. Utilizing a discrete-event framework, the simulation models complex interactions, from dynamic grid signals (updated every 2 seconds) to individual EV charging dynamics. The simulation incorporates multiple EV models created from real-world lab test data. Researchers tested multiple control algorithms to balance the dual objectives of maximizing aggregator’s revenue and driver charging needs. Results demonstrate that aggregated EVs function as a controllable, highly effective grid resource, achieving high PJM Performance Scores (80–90%). Additionally, an optimized, market-aware bidding strategy was identified as key to profitability. The platform was shown to provide drivers with an average charging discount of nearly 50%. The algorithm was further validated in the lab using production EVs and charging stations to compare simulation results with real-world performance.

Manne, Nithin↗

Technical Characterization and Benefit Evaluation of 5G-Enabled Grid Data Transport and Applications

This report summarizes the Year 1 work of Pacific Northwest National Laboratory’s (PNNL’s) 5G Fabricated Resource and Asset Management Encompassment for energy infrastructure (Energy FRAME) project funded by the Department of Energy Office of Science’s Advanced Scientific Computing Research Program. 5G is a breakthrough technology that enables a fully mobile and connected society, and a 5G-enabled digital continuum will be one of the critical foundations for a clean energy economy and grid modernization. In collaboration with PNNL’s Advanced Wireless Communication team and Center for Advanced Technology Evaluation team, the project team has been evaluating the system performance of 5G testbeds in the PNNL 5G Innovation Studio, and has formulated a co-simulation test case of power system transmission, distribution, and communication (T&D&C) networks considering 5G technology and high penetration of distributed energy resources. The methodology developed in the 5G Energy FRAME project can be customized to fit different future grid scenarios to evaluate multiple (dynamic) configurations (computing, sensing, communication, environment) for different stakeholders. In summary, our main technical highlights in project Year 1 are as follows: 1) Technical characterization of 5G standalone architectures, 2) Formulation of co-simulation test case of T&D&C networks embedded with 5G, 3) Initial benefit evaluation of 5G communication platform for grid use cases, and 4) Additional extended discussions on edge computing, artificial intelligence and machine learning, and high-performance computing and cloud computing adoptions. In addition, a collection of system performance data is shared through the publicly available weblink, https://www.pnnl.gov/projects/5g-energy-frame/publications

24 POWER TRANSMISSION AND DISTRIBUTION↗

Latent Neural ODE for Integrating Multi-Timescale Measurements in Smart Distribution Grids

Under a smart grid paradigm, there has been an increase in sensor installations to enhance situational awareness. The measurements from these sensors can be leveraged for real-time monitoring, control, and protection. However, these measurements are typically irregularly sampled. These measure-ments may also be intermittent due to communication bandwidth limitations. To tackle this problem, this paper proposes a novel latent neural ordinary differential equations (LODE) approach to aggregate the unevenly sampled multivariate time-series measurements. The proposed approach is flexible in performing both imputations and predictions while being computationally efficient. Simulation results on IEEE 37 bus test systems illustrate the efficiency of the proposed approach.

multi time-scale measurements↗

Battery Performance, Thermal, and Life Modeling for Southern California Edison (Cooperative Research and Development Final Report)

The objective of this project is to develop battery performance models, thermal models and life models for SCE to use in simulation and analysis of grid services involving energy storage. NREL will fit the models to three separate chemistries using test data provided by SCE. The dataset for each chemistry will include electrical, thermal and aging response to different temperatures and cycling conditions, measured under a variety of cell-level and module-level experiments described in SCE test protocol documents. Once tuned to a test dataset, the battery system model software will provide predictions of battery energy and power loss, and thus cycle and calendar life, for any energy storage grid service power profile of interest to SCE. The automated battery life modeling and simulation tool can also be applied to any other grid battery systems as long as necessary input data is available to accelerate battery model development and battery lifetime analysis.

25 ENERGY STORAGE↗

Simplified Transactive Distribution Grids for Bulk Power System Mechanism Development

As distributed energy resources and smart devices become omnipresent in the electrical power grid, transactive energy control mechanisms are evolving. From real-time to day-ahead markets, these transactive energy algorithms involve more and more agents, whose behavior is going to affect the transmission and generation network. In order to study the interaction between the wholesale and retail energy markets, extensive co-simulations are performed. To be able to redesign, evaluate, and verify new control algorithms, the simulations need to provide results in a fast and reliable manner. This work has built and tested a transactive distribution grid model, the DSO-Stub, meant to offer a configurable distribution retail market while ensuring the computational burden is not significantly increased.

Transactive Energy, , Distribution System Operator↗

Fast Responding Voltage Regulator and Dynamic VAR Compensator

The objectives of this project were to develop a dynamic VAR compensator (DVC) for voltage regulation through VAR support to demonstrate the ability to achieve greater levels of voltage control on electricity distribution networks, and faster response compared to existing grid technology. The goal of the project was to develop a prototype Fast Dynamic VAR Compensator (Fast DVC) hardware device, and this was achieved. In addition to developing the dynamic VAR compensator device, Varentec in partnership with researchers at North Carolina State University (NCSU) successfully met the objectives to model the potential positive impact of such DVCs on representative power networks. This modeling activity validated the ability of distributed dynamic VAR compensators to provide fast voltage regulation and reactive power control required to respond to grid disturbances under high penetration of fluctuating and intermittent distributed energy resources (DERs) through extensive simulation studies. Specifically the following tasks were set to be accomplished: 1) Development of dynamic VAR compensator to support dynamic voltage variations on the grid through VAR control 2) Extensive testing of the DVC in the lab environment 3) Present the operational DVC device to the DOE at Varentec’s lab 4) Formulation of a detailed specification sheet, unit assembly document, test setup document, unit bring-up plan, and test plan 5) Extensive simulations of the DVC in a system with high PV penetration. Understanding the operation with many DVC on a single distribution system 6) Creation and submittal of quarterly and final reports conveying the design documents, unit performance data, modeling simulation charts and diagrams, and summary explanations of the satisfaction of program goals. This report details the various efforts that led to the development of the Fast DVC as well as the modeling & simulation results. The report begins with the introduction in Section II which outlines the problems associated with increasing penetration of renewable resources on the grid and what are the challenges in solving these issues. Section III provides a brief summary of the initial concepts that were explored before the final Fast DVC prototype was developed. Section IV and V present the hardware, controls, communication, and mechanical architecture and features of the Fast DVC. Section VI presents the procedure for assembling the Fast DVC. The test plan and lab setup are expounded in Section VII and VIII. Section IX presents the results from testing the Fast DVC in the lab, several results are presented along with some pictures of the developed unit. Section X details the pilot demonstration activities. Finally, section XI showcases the efforts associated with the simulation and modeling of the Fast DVC in various scenarios with DERs and its impact in all these scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Multiscale Approach To Predict Self-Diffusion from a Potential Energy Field

For large-scale screening studies there is a need to estimate the diffusion of gas molecules in nanoporous materials more efficiently than (brute force) molecular dynamics. In particular for systems with low diffusion coefficients molecular dynamics can be prohibitively expensive. An alternative is to compute the hopping rates between adsorption sites using transition state theory. For large-scale screening this requires the automatic detection of the transition states between the adsorption sites along the different diffusion paths. Here an algorithm is presented that analyzes energy grids for the moving particles. It detects the energies at which diffusion paths are formed, together with their directions. This allows for easy identification of nondiffusive systems. For diffusive systems, it partitions the grid coordinates assigned to energy basins and transitions states, permitting a transition state theory based analysis of the diffusion. We test our method on CH 4 diffusion in zeolites, using a standard kinetic Monte Carlo simulation based on the output of our grid analysis. We find that it is accurate, fast, and rigorous without limitations to the geometries of the diffusion tunnels or transition states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗