Search NASA⌕ Search

SEARCH · Search NASA

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Guided ion beam and theoretical study of the reactions of Au{sup +} with H{sub 2}, D{sub 2}, and HD

Reactions of the late third-row transition metal cation Au{sup +} with H{sub 2}, D{sub 2}, and HD are examined using guided ion beam tandem mass spectrometry. A flow tube ion source produces Au{sup +} in its {sup 1}S (5d{sup 10}) electronic ground state level. Corresponding state-specific reaction cross sections for forming AuH{sup +} and AuD{sup +} as a function of kinetic energy are obtained and analyzed to give a 0 K bond dissociation energy of D{sub 0}(Au{sup +}-H) = 2.13 {+-} 0.11 eV. Quantum chemical calculations at the B3LYP/HW+/6-311+G(3p) and B3LYP/Def2TZVPP levels performed here show good agreement with the experimental bond energy. Theory also provides the electronic structures of these species and the reactive potential energy surfaces. We also compare this third-row transition metal system with previous results for analogous reactions of the first-row and second-row congeners, Cu{sup +} and Ag{sup +}. We find that Au{sup +} has a stronger M{sup +}-H bond, which can be explained by the lanthanide contraction and relativistic effects that alter the relative size of the valence s and d orbitals. Results from reactions with HD provide insight into the reaction mechanism and indicate that ground state Au{sup +} reacts largely via a direct mechanism, in concordance with the behavior of the lighter group 11 metal ions, but includes more statistical behavior than these metals as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Guided ion beam and theoretical study of the reactions of Os{sup +} with H{sub 2}, D{sub 2}, and HD

Reactions of the third-row transition metal cation Os{sup +} with H{sub 2}, D{sub 2}, and HD to form OsH{sup +} (OsD{sup +}) were studied using a guided ion beam tandem mass spectrometer. A flow tube ion source produces Os{sup +} in its {sup 6}D (6s{sup 1}5d{sup 6}) electronic ground state level. Corresponding state-specific reaction cross sections are obtained. The kinetic energy dependences of the cross sections for the endothermic formation of OsH{sup +} and OsD{sup +} are analyzed to give a 0 K bond dissociation energy of D{sub 0}(Os{sup +}-H) = 2.45 {+-} 0.10 eV. Quantum chemical calculations are performed here at several levels of theory, with B3LYP approaches generally overestimating the experimental bond energy whereas results obtained using BHLYP and CCSD(T), coupled-cluster with single, double, and perturbative triple excitations, levels show good agreement. Theory also provides the electronic structures of these species and the potential energy surfaces for reaction. Results from the reactions with HD provide insight into the reaction mechanism and indicate that Os{sup +} reacts via a direct reaction. We also compare this third-row transition metal system with the first-row and second-row congeners, Fe{sup +} and Ru{sup +}, and find that Os{sup +} reacts more efficiently with dihydrogen, forming a stronger M{sup +}-H bond. These differences can be attributed to the lanthanide contraction and relativistic effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Fluid Dynamics Simulations to Predict Oxidation in Heat Recovery Steam Generator Tubes

Heat Recovery Steam Generators (HRSGs) are widely used across United States in combined cycle power plants to recover waste heat from the gas turbine (GT). HRSGs are used either to generate electricity or to produce process steam for industrial applications. The primary components of HRSG consists of a duct and a heat exchanger (HX). It is known across the power industry that the high temperature oxidation and ensuing exfoliation problem is a major cause for the damage of HX materials of HRSG. Alloys and/or coatings that can prevent or mitigate oxidation are very expensive, therefore they must be used or applied on the select regions of the HX tubes where the tendency of oxide formation is the highest. The main goal of this project is to identify such regions through Computational Fluid Dynamics (CFD) simulations. Therefore, in this work, we developed a CFD framework using commercial code StarCCM+ for the prediction of the fluid flow and heat transfer in a HRSG and associated oxidation inside the tubes of the HX. The developed CFD framework was verified and validated with experimental data before deployment. We also developed an innovative method to model the effect of the fins on the heat transfer and the pressure drop using a porous media model (PMM) approach to keep the mesh size within reasonable limits. After validation, we performed high-fidelity CFD simulations of a real-scale HRSG using the PMM, with High Performance Computing (HPC) resources of ORNL. From the simulation results, we acquired oxide thickness maps for all the tubes of the select HX sections of HRSG prone to oxidation. These oxide maps can inform regions of the HX tubes that requires oxide-resistant coatings, thereby guiding engineers for cost-efficient manufacturing of the HX that can combat oxidation in HRSGs.

36 MATERIALS SCIENCE↗

Improved Transparent Furnace For Crystal-Growth Experiments

Novel design and fabrication process for transparent crystal-growing furnace developed. Design consists of one or more heater zones in which heating wire coiled around insides of quartz tubes. Ampoule of material supported inside furnace by guide wire. Crystal then grown by directional freezing of material in ampoule. Distinct feature of use of quartz is capability of direct visual observation of crystal-growth process during experiment. Study of transparent electronic materials conducted in new furnaces.

Rosenthal, Bruce N.↗

PNNL Tests Fish Passage System

Scientists from PNNL are testing a fish transportation system developed by Whooshh Innovations. The Whooshh system uses a flexible tube that works a bit like a vacuum, guiding fish over hydroelectric dams or other structures. Compared to methods used today, this system could save money while granting fish quicker, safer passage through dams and hatcheries.

13 HYDRO ENERGY↗

SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

60 APPLIED LIFE SCIENCES↗

The piston-flow interaction as a model for the deflagration-to-detonation transition

The piston-flow interaction induced by a piston pushing hydraulically resisted gas through a long tube is discussed. It is shown that the hydraulic resistance causes a significant precompression and preheating of the gas adjacent to the piston's edge. In the case of an explosive premixture this development may lead to a localized autoignition triggering detonation. It is suggested that the problem may serve as a guide for understanding the deflagration-to-detonation transition in tubes, with the piston modeling the impact of the advancing flame. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Weld preparation tool for pipes and tubing

Improved scarfing tool consists of a mount-table, roller-guided assembly. It converts a conventional routing machine for relatively precise field preparation of pipes for welding.

Wallace, E. D.↗

Design constraints of the LST fine guidance sensor

The LST Fine Guidance Sensor design is shaped by the rate of occurrence of suitable guide stars, the competition for telescope focal plane space with the Science Instruments, and the sensitivity of candidate image motion sensors. The relationship between these parameters is presented, and sensitivity to faint stars is shown to be of prime importance. An interferometric technique of image motion sensing is shown to have improved sensitivity and, therefore, a reduced focal plane area requirement in comparison with other candidate techniques (image-splitting prism and image dissector tube techniques). Another design requirement is speed in acquiring the guide star in order to maximize the time available for science observations. The design constraints are shown parametrically, and modelling results are presented.

Wissinger, A. B.↗

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of 2.8 • 10 -4 to 4.1 • 10 -4 for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential η of 1.7 • 10 -4 to 3.3 • 10 -4 . Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. In conclusion, based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with η = 3.5(5)•10 -4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-239: Evaluation of Plastic Scintillator Light Output for Various Lead Doping Concentrations: Towards LET Detection

Purpose: This work seeks to develop a beam quality meter using multiple differently doped plastic scintillators that are thus intrinsically beam-quality dependent. Plastic scintillators spontaneously emit visible light upon irradiation; the amount of light produced is dependent on stopping power (closely related to LET) according to Birks’ law. Doping plastic scintillators can be used to tune their sensitivity to specific LET ranges. Methods: GEANT4.10.1 Monte Carlo (MC) was used to evaluate the response of various scintillator dopant combinations. MC radiation transport and scintillator light response were validated against previously published literature. Current work involves evaluating detector response experimentally; to that end, a detector prototype with interchangeable scintillator housing was constructed. Measurement set-up guides light emitted by the scintillator to a photomultiplier tube via a glass taper junction coupled to an optical fiber. The resulting signal is measured by an electrometer, and normalized to dose readout from a diode. Measurements have been done using clinical electron and orthovoltage beams. MC response (simulated scintillator light normalized to dose scored inside the scintillating volume) was evaluated for four different LET radiations for an undoped and 1%Pb doped scintillator (σ=0.85%). Simulated incident electrons included: 0.05, 0.1, 0.2, 6, 12, and 18 MeV; these energies correspond to a range of stopping power (related to LET) values ranging from 1.824 to 11.09 MeVcm{sup 2}g{sup −1} (SCOL from NIST-ESTAR). Results: Initial MC results show a distinct divergence in scintillator response as LET increases. The response for undoped plastic scintillator indicated a 35.0% increase in signal when going from 18 MeV (low LET) to 0.05 MeV (high LET) while 1%-Pb doped scintillator indicated a 100.9% increase. Conclusion: After validating MC against measurement, simulations will be used to test various concentrations (2%, 4%, 6%) of different high-Z material dopants (W, Mo) to optimize the scintillator types for the beam quality meter. NSERC Discovery Grant RGPIN-435608.

60 APPLIED LIFE SCIENCES↗

Electronic skewing circuit monitors exact position of object underwater

Linear Variable Differential Transformer /LVDT/ electronic skewing circuit guides a long cylindrical capsule underwater into a larger tube so that it does not contact the tube wall. This device detects movement of the capsule from a reference point and provides a continuous signal that is monitored on an oscilloscope.

Roller, R.↗

Outpatient Management of Postbiopsy Pneumothorax with Small-Caliber Chest Tubes: Factors Affecting the Need for Prolonged Drainage and Additional Interventions

The aim of this study was to evaluate the efficacy of outpatient management of postbiopsy pneumothoraces with small-caliber chest tubes and to assess the factors that influence the need for prolonged drainage or additional interventions.We evaluated the medical records of patients who were treated with small-caliber chest tubes attached to Heimlich valves for pneumothoraces resulting from image-guided transthoracic needle biopsy to determine the hospital admission rates, the number of days the catheters were left in place, and the need for further interventions. We also evaluated the patient, lesion, and biopsy technique characteristics to determine their influence on the need for prolonged catheter drainage or additional interventions. Of the 191 patients included in our study, 178 (93.2%) were treated as outpatients. Ten patients (5.2%) were admitted for chest tube-related problems, either for underwater suction (n = 8) or for pain control (n = 2). No further interventions were required in 146 patients (76.4%), with successful removal of the chest tubes the day after the biopsy procedure. Prolonged catheter drainage (mean, 4.3 days) was required in 44 patients (23%). Nineteen patients (9.9%) underwent additional interventions for management of pneumothorax. Presence of emphysema was noted more frequently in patients who required additional interventions or prolonged chest tube drainage than in those who did not (51.1% vs. 24.7%; p = 0.001).We conclude that use of the Heimlich valve allows safe and successful outpatient treatment of most patients requiring chest tube placement for postbiopsy pneumothorax. Additional interventions or prolonged chest tube drainage are needed more frequently in patients with emphysema in the needle path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

State-of-the-Art Review on Crystallization Control Technologies for water/LiBr Absorption Heat Pumps

The key technical barrier to using water/lithium bromide (LiBr) as the working fluid in aircooled absorption chillers and absorption heat-pump systems is the risk of crystallization when the absorber temperature rises at fixed evaporating pressure. This article reviews various crystallization control technologies available to resolve this problem: chemical inhibitors, heat and mass transfer enhancement methods, thermodynamic cycle modifications, and absorption system-control strategies. Other approaches, such as boosting absorber pressure and J-tube technology, are reviewed as well. This review can help guide future efforts to develop water/LiBr air-cooled absorption chillers and absorption heatpump systems.

99 GENERAL AND MISCELLANEOUS↗

Composite structure dynamics and space applicability

Guided wave modes in cladded or uncladded fiber-reinforced composite plates and tubes have been analyzed using a stiffness method in which the displacement variation through the thickness is approximated by polynomial interpolation functions. This allows for an arbitrary number of laminations and fiber orientations different from lamina to lamina. It is shown that dispersive behavior of guided modes depends significantly on the cladding, number of laminae, and interfaces between the adjacent laminae. A hybrid modeling technique is described in which an inner region containing cracks (or other defects) is discretized by finite elements, and the field in the exterior region is represented in terms of modes that are found using the stiffness method described above. It is found that the reflected and transmitted amplitudes of modes vary significantly with the size of a transverse or longitudinal (delamination) crack and frequency. We have also studied the impact response of a unidirectional fiber-reinforced plate. Received signals at the epicentral and other locations are shown. Strong longitudinal anisotropy of the graphite/epoxy plate causes the signal to be considerably different from that in an isotropic plate.

Datta, Subhendu K.↗

Dynamic Frictional Characteristics of TP2 Copper Tubes during Hydroforming under Different Loading and Fluid Velocities

Tube hydroforming (THF) experiments were performed on TP2 copper tubes under different loading velocities and fluid velocities using a self-developed measurement system to investigate dynamic frictional characteristics in the guiding zone. The results show that the coefficient of friction (COF) dynamically changes during forming experiments and decreases with tube deformation. The average descending rate and amplitude of the COF increase with increasing loading velocity. Microscopically, the micro-protrusions on the tubular surface are flattened, and the surface scratches are finer and more uniform, as the loading velocity increases, resulting in a decrease in COF. At the same external loading velocity, the COF increases with increasing fluid velocity and is also extremely sensitive to it. Moreover, improving and predicting the formability of such tubes by accurately adjusting and controlling fluid velocity in THF is valuable and critical for the future.

36 MATERIALS SCIENCE↗

Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of fast timing MCP-PMTs in magnetic fields

Here, the motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested. The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the rotation angle of the MCP-PMT relative to the magnetic field direction and of the bias voltage between the photocathode and the top MCP were extensively investigated using the MCP-PMT based on the independently biased voltage design. It was found that the signal amplitude of the MCP-PMT exhibits an enhanced performance at a tilt angle of ±8°, due to the 8°bias angle of the MCP pores. Fianlly, the maximum signal amplitude was observed at different bias voltages depending on the magnetic field strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗