Evaluation of Heat Exchanger Technology for Integrated Energy System: Methodology and Preliminary Application

This report proposes a novel heat exchanger evaluation method, based on integrated QFD-AHP technique, to support strategic optimal selection of heat exchanger (HX) technology for integrated energy systems. The term “optimal selection” is defined as selecting a product (i.e., HX) that best meets various aspects of end user demand, including both technical and economic requirements. Compared to previous HX evaluation methods, the proposed approach allows decision makers to explicitly take into account the practical demand of customers (i.e., HX end users) which may vary depending on the HX application target. In addition, the proposed evaluation method can be used not only for high-level decisions to select HX type, but also for low-level decisions such as the selection of the key components including HX material or heat transfer fluid. The focus of this study is to describe the new HX evaluation method and to illustrate the overall HX evaluation and selection processes using the three nuclear heat application cases that represent the thermal integration between advanced nuclear reactors and industrial processes. As a preliminary study, three different types of HX, i.e., shell-and-tube heat exchanger, printed circuit heat exchanger, and heat pipe heat exchanger, were compared.

42 ENGINEERING↗

Liquid droplet heat exchanger studies

Recent analytical and experimental investigations of the liquid droplet heat exchanger (LDHX) concept for space power applications are described. The performance of the LDHX is compared to that of a conventional heat exchanger for heat rejection applications in a Brayton cycle, using the mass-specific heat exchanger effectiveness as a figure of merit. It is shown that the LDHX has an order of magnitude advantage over the conventional heat exchanger. Furthermore, significant improvement in cycle efficiency and power to mass ratio is possible. Two-phase flow experiments in a laboratory scale LDHX, using air and water as the two media, show very good agreement with the quasi-one-dimensional model used in the parametric studies.

Bruckner, A. P.↗

Design of a SiC-Si moving packed-bed particle-to-sCO 2 heat exchanger for high temperature concentrating solar power applications

Particle-based concentrating solar power systems integrated with sCO 2 power cycles offer high thermal efficiencies but require durable heat exchangers to transfer heat from high-temperature particles to the sCO 2 working fluid. Here, this study presents the design and optimization of a silicon carbide-silicon moving packed-bed heat exchanger for fabrication via binder jetting additive manufacturing. The heat exchanger was designed to withstand a 20 MPa sCO 2 pressure and operate at particle inlet temperatures up to 750 °C. The final design features 152 sCO 2 channels distributed across 19 plates, with elliptical corners and a minimum wall thickness of 3 mm. Flow restrictors at the sCO 2 channel inlets significantly improved flow uniformity, reducing thermal stresses and achieving a structural reliability of 99 % under representative operating conditions. The heat exchanger delivers a thermal duty of 9 kW and a volumetric power density of approximately 1 MW/m 3 in the channel region. Sensitivity studies confirmed the heat exchanger’s robustness under varying operating conditions, demonstrating its viability as a high-performance alternative to metallic heat exchangers for particle-based high-temperature concentrating solar power applications.

Barua, Bipul [Argonne National Laboratory (ANL), A↗

Oscillating-Coolant Heat Exchanger

Devices useful in situations in which heat pipes inadequate. Conceptual oscillating-coolant heat exchanger (OCHEX) transports heat from its hotter portions to cooler portions. Heat transported by oscillation of single-phase fluid, called primary coolant, in coolant passages. No time-averaged flow in tubes, so either heat removed from end reservoirs on every cycle or heat removed indirectly by cooling sides of channels with another coolant. Devices include leading-edge cooling devices in hypersonic aircraft and "frost-free" heat exchangers. Also used in any situation in which heat pipe used and in other situations in which heat pipes not usable.

Scotti, Stephen J.↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system's liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems, but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.6 lb. The water side and gas side pressure drops were 0.8 psid and 0.5 inches of water, respectively. Performance of the heat exchanger at the nominal pressure of 4.1 psia was measured at 94%, while a gas inlet pressure of 25 psia resulted in an effectiveness of 84%. These results compared well with the model, which was scaled for the small size. Modeling of certain phenomena that affect performance, such as flow distribution in the headers was particularly difficult due to the small size of the heat exchanger. Data from the tests has confirmed the correction factors that were used in these parts of the model.

Jennings, Mallory↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Apparatus and method for intrachannel defouling of a heat exchanger using induction heaters

An apparatus comprising a heat exchanger and one or more induction heating elements is disclosed. The heat exchanger comprises a coolant side conduit and a process side conduit, the process side conduit being susceptible to fouling by at least partial desublimation, condensation, crystallization, deposition, or combinations thereof of a fouling component of a circulating process fluid. An electrically conductive first metal is disposed adjacent to the process side conduit. The one or more induction heating elements are disposed proximate to the heat exchanger. The one or more induction heating elements are connected to a source of electrical current. When the electrical current flows through the induction heating elements, eddy currents are induced in the first metal, heating the first metal such that the fouling component sublimates, melts, absorbs, or a combination thereof into the circulating process fluid.

42 ENGINEERING↗

Development, Fabrication, and Testing of a Liquid/Liquid Microchannel Heat Exchanger for Constellation Spacecrafts

Microchannel technology can be incorporated into heat exchanger designs to decrease the mass and volume of space hardware. The National Aeronautics and Space Administration at the Johnson Space Center (NASA JSC) partnered with Pacific Northwest National Laboratories (PNNL) to develop a liquid/liquid microchannel heat exchanger that has significant mass and volume savings without sacrificing thermal and pressure drop performance. PNNL designed the microchannel heat exchanger to the same performance design requirements of a conventional plate and fin liquid/liquid heat exchanger; 3 kW duty with inlet temperatures of 26 C and 4 C. Both heat exchangers were tested using the same test parameters on a test apparatus and performance data compared.

Hawkins-Reynolds, Ebony↗

Additive manufacturing and testing of a ceramic heat exchanger for high-temperature and high-pressure applications for concentrating solar power

Heat exchangers with excellent corrosion and oxidation resistances are essential for the next-generation concentrating solar power (CSP) plants using a molten salt heat transfer fluid and a supercritical CO 2 Brayton power cycle that can operate at temperatures > 700 °C for higher efficiencies. Techniques were developed for additively manufacturing ceramic materials for applications involving high temperature, high pressure, and high corrosion resistance as needed for the CSP application. Based on a previous ceramic heat exchanger design with its cross-section geometry of the flow channels optimized for heat transfer and mechanical strength, lab-scale prototype heat exchangers, with integrated headers and incorporated flow channel dimensional compensations, were fabricated by using the binder jetting process. The printed prototype heat exchangers were successfully densified through the processes of liquid polymer infiltration and pyrolysis. In addition, thermophysical properties of the densified silicon carbide parts were measured to provide necessary design information. Experimental heat transfer testing of the lab-scale prototype heat exchanger was conducted, and the experimental data agreed reasonably well with the simulated results. Furthermore, this agreement provides validation of the simulation models for their applicability to the development of a full-scale ceramic heat exchanger.

14 SOLAR ENERGY↗

High heat flux single phase heat exchanger

This paper presents the results obtained to date in a program to develop a high heat flux, single-phase heat exchanger for spacecraft thermal management. The intended application is a net generation interface heat exchanger to couple the crew module water thermal bus to the two-phase ammonia main thermal bus in the Space Station Freedom. The large size of the interface heat exchanger is dictated by the relatively poor water-side heat transfer characteristics. The objective of this program is to develop a single-phase heat transfer approach which can achieve heat fluxes and heat transfer coefficients comparable to those of the evaporation ammonia side. A new heat exchanger concept has been developed to meet these objecties. The main feature of this heat exchanger is that it can achieve very high heat fluxes with a pressure drop one to two orders of magnitude lower than those of previous microchannel or jet impingement high heat flux heat exchangers. This paper describes proof-of-concept experiments performed in air and water and presents analytical model of the heat exchanger.

Valenzuela, Javier A.↗

Multiscale Porous High-temperature Heat Exchanger Using Ceramic Co-extrusion

In this project, our MIT, Purdue, and GE team aims to design, model, fabricate, and test a novel high temperature, compact, and durable ceramic heat exchanger to be operated under high temperature and pressure conditions for aerospace applications. Our approach is grounded in introducing multiscale porosity, i.e., centimeter-scale channels embedded with micrometer-scale channels, into the ceramic heat exchanger to significantly improve its heat transfer performance and mechanical strength while maintaining minimal pressure losses. We first developed high-fidelity thermal-fluid-mechanical model capable of precisely capturing the heat transfer rate, temperature profile, pressure drop, and mechanical stress throughout the entire heat exchanger design. Guided by our model, we identified the optimal design parameters for the SiC heat exchanger body and manifolds. Then, we established a completed fabrication procedure to create multiscale features in the ceramic heat exchanger, including co-extrusion, lamination, burnout, and sintering. We fabricated multiple heat exchanger bodies consisting of 6 × 6 and 3 × 3 centimeter-scale channels where each individual centimeter-scale channel comprises 625 crack-free microchannels with 90 μm × 90 μm opening. Owing to the multiscale features, our fabricated heat exchanger bodies exhibited desirable mechanical strength with 156 MPa flexural strength under 1300 Celsius degree. Despite the demonstrated highly tailorable microscopic features and superior mechanical strength, we identified delamination due to the complex interaction among ceramic, polymer, and gas species can be a critical challenge to create fully defect-free heat exchanger, which requires further fundamental investigations in future works. To test the heat exchanger performance, we constructed a high-temperature and high-pressure experimental apparatus that can be safely operated under 400 Celsius degree and 4 bar. With insights gained from mechanistic modeling, material development, and detailed characterization, a cost model was finally developed to understand the market potential of the developed technology, where a cost of $43,000 Celsius degree/kW was envisioned. This project developed a transformative approach to high-performance heat exchanger design. The thermal-fluid-mechanical design approach developed in this project can serve as a generic tool to guide the design of various heat-exchangers operated under high-temperature and high-pressure conditions. The material fabrication approach established in this project can be a useful guide for ceramic processing at extreme length scales.

42 ENGINEERING↗

Thermal control of a lidar laser system using a non-conventional ram air heat exchanger

This paper describes the analysis and performance testing of a uniquely designed external heat exchanger. The heat exchanger is attached externally to an aircraft and is used to cool a laser system within the fuselage. Estimates showed insufficient cooling capacity with a conventional staggered tube array in the limited space available. Thus, a non-conventional design wes developed with larger tube and fin area exposed to the ram air to increase the heat transfer performance. The basic design consists of 28 circular finned aluminum tubes arranged in two parallel banks. Wind tunnel tests were performed to simulate air and liquid flight conditions for the non-conventional parallel bank arrangement and the conventional staggered tube arrangement. Performance comparisons of each of the two designs are presented. Test results are used in a computer model of the heat exchanger to predict the operating performance for the entire flight profile. These analyses predict significantly improved performance over the conventional design and show adequate thermal control margins.

Killough, Brian D.↗

Temperature distribution in internally heated walls of heat exchangers composed of nonnuclear flow passages

In the walls of heat exchangers composed of noncircular passages, the temperature varies in the circumferential direction because of local variations of the heat-transfer coefficients. A prediction of the magnitude of this variation is necessary in order to determine the region of highest temperature and in order to determine the admissible operating temperatures. A method for the determination of these temperature distributions and of the heat-transfer characteristics of a special type of heat exchanger is developed. The heat exchanger is composed of polygonal flow passages and the passage walls are uniformly heated by internal heat sources. The coolant flow within the passages is assumed to be turbulent. The circumferential variation of the local heat-transfer coefficients is estimated from flow measurements made by Nikuradse, postulating similarity between velocity and temperature fields. Calculations of temperature distributions based on these heat-transfer coefficients are carried out and results for heat exchangers with triangular and rectangular passages are presented.

Eckert, E R G↗

Phase Change Material Heat Exchanger Life Test

Low Lunar Orbit (LLO) poses unique thermal challenges for the orbiting space craft, particularly regarding the performance of the radiators. The IR environment of the space craft varies drastically from the light side to the dark side of the moon. The result is a situation where a radiator sized for the maximal heat load in the most adverse situation is subject to freezing on the dark side of the orbit. One solution to this problem is to implement Phase Change Material (PCM) Heat Exchangers. PCM Heat Exchangers act as a "thermal capacitor," storing thermal energy when there is too much being produced by the space craft to reject to space, and then feeding that energy back into the thermal loop when conditions are more favorable. Because they do not use an expendable resource, such as the feed water used by sublimators and evaporators, PCM Heat Exchangers are ideal for long duration LLO missions. In order to validate the performance of PCM Heat Exchangers, a life test is being conducted on four n-Pentadecane, carbon filament heat exchangers. Fluid loop performance, repeatability, and measurement of performance degradation over 2500 melt-freeze cycles will be performed.

Lillibridge, Sean↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system s liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems (UTAS), but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.57 lb. Performance of the heat exchanger met the requirements and the model predictions. The water side and gas side pressure drops were less 0.8 psid and 0.5 inches of water, respectively, and an effectiveness of 94% was measured at the nominal air side pressure of 4.1 psia.

Quinn, Gregory J.↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗