Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

MHD-induced SOL filaments and divertor heat flux striations in NSTX

Magnetohydrodynamic (MHD) activity in NSTX has been found to induce striated heat flux patterns at the divertor. These striated heat fluxes were previously interpreted as strike-point splitting caused by stochastic magnetic lobes near the X-point. Recent analysis indicates that MHD can directly generate filaments in the scrape-off layer (SOL), and the MHD-related filaments are consistent with the rotation and the frequency of the MHD. Magnetic field line tracing from the mid-plane of the MHD-related filaments to the divertor is consistent with the location of striated heat fluxes on the divertor. Additionally, gas puff imaging (GPI) diagnostic data shows the generation of regular blobs following each edge harmonic oscillation (EHO) toroidal mode number n = 1 perturbation, which indicates that the MHD perturbation directly drives the blobs. These blobs are responsible for the divertor heat flux striations. Here, this finding provides a new framework for understanding MHD-induced edge transport and has important implications for heat-load control in NSTX-U and future spherical tokamaks.

MHD↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Toroidal modeling of 3D perturbations generated by current filaments in scrape-off layer in tokamak with biased divertor targets

The divertor biasing technique offers a promising alternative to control the edge localized mode (ELM) as well as the divertor heat load in tokamaks, as compared to the resonant magnetic perturbation (RMP) generated by magnetic coils. The linear resistive MHD code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) is employed to study the plasma response to the n = 2 (n is the toroidal mode number) field perturbation in HL-2A, produced by the divertor biasing current filaments flowing in the scrape-off layer region. The response field due to biasing currents is compared with the RMP field utilized for ELM control in HL-2A. The strength of the radial resonant field perturbation, produced by the biasing currents of 100 A level, is found to be comparable with RMP generated by several kA of ELM control coil currents for the reference plasma. The plasma normal displacement near the X-point and the associated neoclassical toroidal viscosity torque are also computed to be similar between these two techniques. The modeling results thus strongly suggest that the biasing technique can be applied to control ELMs. Moreover, the biasing currents produce field perturbations, including the plasma response, that are localized more near the plasma edge (compared to the RMP counterpart), thus reducing the chance of mode locking associated with core perturbations. Particle orbit tracing also reveals that the biasing current produced magnetic perturbation tends to widen the heat deposition region and induce the strike point splitting of the ion saturation flow on the outer divertor surface, consistent with experimental observations in HL-2A. These toroidal modeling results confirm the possibility of ELM control and plasma exhaust solution by the divertor biasing technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steady-State Mechanical Analysis for Target Assembly in the Material Plasma Exposure eXperiment Facility

The Material Plasma Exposure eXperiment (MPEX) steady-state linear plasma facility is currently under design at Oak Ridge National Laboratory to expose target specimens to fusion divertor regimes. The neutron-irradiated target is actively cooled and remote handled in the MPEX facility for conducting plasma-material–interaction (PMI) experiments. Here, the steady-state stresses in the target and target assembly system are investigated using two-dimensional (2-D) and three-dimensional (3-D) models to provide expected stresses/strains under the heat loads to which various system components would be exposed during MPEX operation. The calculated temperatures from the 2-D axisymmetric mechanical model were found to be in excellent agreement with those from the full 3-D thermohydraulic model, providing a strong model validation. Numerical simulation results for the steady-state mechanical model indicate nonuniform distributions for the temperature, stress, and deformation within the critical components. For the initial design, the deformation results indicate possible gap openings between contacting surfaces below the plasma-facing materials. To reduce the possibility of interfacial gap opening, the target assembly was slightly changed and evaluated using the 2-D stress model. Numerical simulation results indicate that the interfacial gap openings can be minimized without drastically changing the entire target assembly. The stress-strain conditions for the target will be further used to assess the appropriate operation during MPEX experiments and gain insight into materials science phenomena during PMI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Alfvén mode spectrum in the advanced steady-state tokamak scenario with negative triangularity

In the earlier studies [Zheng et al. Fundam. Plasma Phys. 10, 100051 (2024)], the negative triangularity tokamak was shown to have a unique and outstanding feature for the steady-state confinement. In addition to relieving the divertor heat load concern, it can reach a much higher beta limit in the nearly steady-state confinement, about twice the Troyon limit in the positive triangularity case. In this work, we extend the investigation to the Alfvén spectrum and toroidal Alfvén eigenmodes (TAEs). This helps to evaluate the property of energetic particle confinement in this advanced scenario of a negative triangularity tokamak. We found that, because of the large safety factor and reversed magnetic shear in the core plasma region near the magnetic axis, the TAE gap tends to be closed or have only a short radial extension between the continua. in the on-axis core region and open primarily in the off-axis region, where TAEs are shown to be present. This indicates that energetic particle confinement in the core region near the magnetic axis, where nuclear fusion reactions prevail, is not seriously affected by the excitation of TAEs in this scenario. The configuration with off-axis TAEs helps the confinement of energetic particles as compared to the configuration with near-axis TAEs. The results show that the advanced steady-state tokamak scenario with negative triangularity, because of the rapid variation of the safety factor, also has a favorable feature for energetic particle confinement.

Fourier analysis↗

UEDGE modeling of plasma detachment of CFETR with ITER ‐like divertor geometry by external impurity seeding

Abstract Efficient handling of high heat flux on the plasma‐facing components, particularly the divertor targets, poses a significant challenge for the Chinese Fusion Engineering Testing Reactor (CFETR) with fusion power of Gigawatt. This work investigates the divertor plasma detachment of CFETR with a standard ITER‐like divertor geometry by neon (Ne) or argon (Ar) impurity seeding using UEDGE code. The cross‐field drifts terms are switched off, and fluid neutral models and a “fixed‐fraction” impurity model are applied to enable efficient simulations for the study of CFETR detachment. In order to reduce the heat load on the divertor targets below the acceptable level (<10 MW/m 2 ), the impurity fraction ( f ), pumping speed ( S ), and upstream density are varied to identify the suitable operations window during Ne seeding. The effects of Ne and Ar impurities on the plasma detachment are compared. It is found that with the power across the core‐edge interface P SOL = 200 MW and separatrix density of 2.8 10 19 , Ne impurity fraction ≥1.7%, and Ar impurity fraction ≥0.24% can achieve the partial detachment. Achieving similar total radiation power (˜148 MW), the Ne fraction is 2.3% and the Ar fraction is 0.24%. Moreover, the simulation results indicate that Ar exhibits better power radiation efficiency and core compatibility compared with Ne.

Zhang, M. Z.↗

Fractionation of UF6 and daughter progeny in storage cylinders from external heating

Abstract Uranium hexafluoride (UF 6 ) is a significant concern for material accountancy and verification in the international safeguards community. Verification of the contents of UF 6 cylinders is generally attempted with gamma spectroscopy but the current methods assume a uniform, homogeneous UF 6 mass distribution within the cylinder. In this work, it was found experimentally and confirmed via modeling, that under an external heat load (the sun), the UF 6 and its daughter products undergo fractionation in the cylinder. This fractionation of the UF 6 and daughter products can cause an errant measurement of the enrichment of the cylinder when using the current verification methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Burn parameters affect PAH emissions at conditions relevant for prescribed fires

Wildfire smoke is a health hazard as it contains carcinogenic volatile compounds and fine particulate matter. In particular, exposure to polycyclic aromatic hydrocarbons (PAHs) is a major concern, since these compounds have been recognized as important contributors to the overall carcinogenic risk. In this work, gas and particle-phase PAH emissions from combustion of Eastern White Pine (Pinus strobus) were quantified using time-of-flight mass spectrometry over a range of burn conditions representative of wildfires and prescribed fires, including fuel moisture, heat flux, and oxygen concentration. We found that changing the burn environment lead to a variability of up to 77% in phenanthrene/anthracene emissions. This could explain a large part of the variability in PAH emission factors from biomass combustion reported in the literature. Here, we found that optimal conditions for fuel moisture content of 20–30%, sample heat load of 60 - 70 kW m -2 , and oxygen concentrations of 5–15% can significantly reduce the emissions of heavy molar weight PAHs. Our analysis showed that the relative carcinogenic risk from PAH exposure can be reduced by more than 50% under optimal conditions. In light of the increasing use of prescribed fire for forest management, the relationship between emissions and burn conditions that we have established provides a guidance for assessing the expected health impact from prescription burns, and can inform strategies to reduce PAH emissions from prescribed fire activities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2-D moving mesh modeling of lithium dryout in open surface liquid metal flow applications

Liquid lithium displays increasing promise as a replacement for solid plasma facing components (PFCs) in fusion device applications. The Liquid Metal Infused Trench (LiMIT) system, developed at the University of Illinois (UIUC), has demonstrated how thermoelectric magnetohydrodynamics (TEMHD) can be harnessed to drive liquid lithium flow in an open surface PFC. However, in the highest heat flux applications, large local acceleration is created via TEMHD, and the sudden increase in velocity can cause the liquid level to expose the underlying solid, eliminating the protective benefits of the lithium. In order to study potential mitigation strategies, a 2-D COMSOL Multiphysics model was developed using the moving mesh module to capture free surface flow. The model depicts the development of the dryout phenomenon for 2 test cases – slow (1 cm/s) and medium (10 cm/s) flow in 5 mm deep trenches – including the liquid level reduction under the high heat flux and the pileup of slower flow both upstream and downstream of the heat stripe. The effectiveness of trench shaping dryout mitigation strategies is examined. For the slow flow case, it is shown that a 1.8 mm ledge placed under the heat stripe will stop dryout, and for the medium flow case, a 2.7 mm ledge is required to mitigate the effect. This model can be used to identify strategies for increasing the viable heat load for open surface liquid lithium PFCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of the burning-plasma operational space in ITER by using a control-oriented core-SOL-divertor model

In future tokamaks, the control of burning plasmas will require careful regulation of the plasma density and temperature. Along with the design of effective burn-control systems, understanding how the fusion power varies in the density-temperature space is vital for the operation of fusion power plants. Here in this work, the steady-state operational space of ITER is studied using a control-oriented core-plasma model coupled to a two-point model of the scrape-off-layer (SOL) and divertor regions. The two models are coupled through the exchange of input-output parameters. The deuterium and tritium recycling from the wall are output parameters of the SOL-divertor model that are used as input parameters in the core-plasma density balance. Furthermore, the separatrix temperature, which is an output parameter of the SOL-divertor model, is incorporated into the radial core-plasma temperature profiles. Therefore, the temperature-dependent power balance of the plasma core is intimately linked to the SOL-divertor model. Both the power entering the SOL from the core, as determined by the core-plasma power balance, and the separatrix density, as dictated by the core-plasma density balance, are input parameters to the SOL-divertor model. They are control knobs in the SOL-divertor model that can be regulated using the core-plasma actuators: auxiliary power and pellet injection. There are various operational limitations, such as the saturation of the aforementioned actuators, that will prevent ITER from accessing certain high-fusion plasma regimes. The achievable tritium concentration in the fueling lines and the maximum sustainable heat load on the divertor will impose further restrictions. By accounting for these limitations, the ITER operational space is computed based on the coupled core-SOL-divertor model and visualized using Plasma Operation Contour (POPCON) plots that map performance metrics, such as the fusion to auxiliary power ratio, over the density-temperature space. Comparisons are drawn between plasmas with different recycling, confinement, and SOL-divertor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD flow in liquid metal blankets: Major design issues, MHD guidelines and numerical analysis

The design of breeding blankets represents the major challenge for fusion reactor engineering because of performance requirements and severe operating conditions in terms of heat load and neutron flux. Liquid metal alloys such as lead-lithium, due to their lithium content, can be used to breed tritium, one of the plasma fuel components, and owing to their high thermal conductivity, they may serve as coolants. On the other hand, there are technical issues related to the fact that the liquid metals are electrically conducting and interact with the plasma-confining magnetic field. Induced electric currents and generated electromagnetic forces affect velocity and pressure distribution in the blankets. Magnetohydrodynamic (MHD) flows for fusion applications have been often investigated in simplified geometries, such as pipes, ducts, bends, with focus on their fundamental features. These analyses are essential, since results remain valid as background for the development of blanket designs, even when a concept is dismissed. However, the conceptual study of fusion blankets requires to take into account the global multiple effects, that arise when the full system is considered. Progress made in fusion-related MHD research results from combined numerical and experimental activities. In this paper we review and summarize features of 2D and 3D MHD flows that are typical in liquid metal blankets, together with available correlations for MHD pressure losses. This knowledge can provide simple design MHD guidelines that support a preliminary estimate of MHD effects in a blanket concept, in terms of pressure drop and flow distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum commissioning and operation result after the KSTAR PFC upgrade

The first vacuum commissioning after the installation of new tungsten mono-block cassette divertor has been successfully conducted in KSTAR. The tungsten divertor has been installed in the lower divertor region to handle the high divertor heat loads up to 10 MW/m 2 . On the one hand, the plasma facing components except for the tungsten divertor in the KSTAR vacuum vessel still consists of graphite tiles. Thus, it was much more challenging to maintain high-quality vacuum condition mainly because of various possible impurity sources inside the vessel compared with previous experiment campaigns. In this paper, the detailed procedure for securing vacuum condition of the KSTAR tokamak after the installation of the new tungsten divertor is presented. The vacuum condition is also examined regarding the plasma start-up and the long-pulse high-performance quality.

KSTAR↗

Effect of aging on failure mechanism of Alloy 709 at various temperatures

Alloy 709 is a novel austenitic stainless steel with high temperature creep strength, weldability, and corrosion resistance. These properties make the material suitable for applications in the structure of next-generation nuclear power plants. Enduring high temperatures for an extended period of time in the harsh environments of a nuclear power plant results in thermal aging of the material. Therefore, it is imperative to study the effect of thermal aging on the microstructure and mechanical properties of Alloy 709 before its application in the next generation power plants. In this study, hot-processed (forged + rolled), annealed and quenched ingots of Alloy 709 are aged at 650 °C for 2000 h in air and then tested at various temperatures up to 850 °C in an in-situ heating-loading Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectroscopy (EDS) and Electron Backscatter Diffraction (EBSD). The effect of testing temperature and aging on microstructural evolutions during tensile testing of as-received and aged samples are studied. Furthermore, both as-received and aged samples displayed serrations and drop in ductility at elevated temperatures, due to the effect of dynamic strain aging (DSA). The occurrence of DSA activity was found within temperatures range of 500 °C–750 °C in as-received and 550 °C - 650 °C in aged samples. The aged samples showed less elongation accompanied by shallower dimples on the fractured surface, indicating less ductile failure mechanism compared to as-received samples. Failure mechanism observations on the fracture surface using SEM fractography are correlated to the observations made on the sample surface using in-situ SEM to achieve a complementary set of information to better understand the failure mechanism of this novel alloy.

36 MATERIALS SCIENCE↗