Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Fast and Accurate Intersections on a Sphere

We introduce a fast, high-precision algorithm for calculating intersections between great circle arcs and lines of constant latitude on the unit sphere. We first propose a simplified intersection point formula with improved speed and numerical robustness over the ones traditionally implemented in geoscience software. We then show how algorithms based on the concept of error-free transformations (EFT) can be applied to evaluate this formula within a relative error bound that is on the order of machine precision. Here, we demonstrate that, with a vectorized and parallelized implementation, this enhanced accuracy is achieved with no compute time overhead compared to a direct calculation in hardware floating point, making our algorithm suitable for performance-sensitive applications like regridding of high-resolution climate data. In contrast, evaluating our formula using high-precision data types like quadruple precision and arbitrary precision, or using the robust intersection computation routines from the Computational Geometry Algorithms Library, leads to significant computational overhead, especially since these alternatives inhibit vectorization. More generally, our work demonstrates how EFT techniques can be combined and extended to implement nontrivial geometric calculations with high accuracy and speed.

Environmental sciences↗

Reanalysis of the top-quark pair hadroproduction and a precise determination of the top-quark pole mass at the LHC *

In this study, we calculate the $t\bar{t}$ pQCD production cross-section at the NNLO and determine the top-quark pole mass from recent measurements at the LHC at the center-of-mass energy $\sqrt{S}=13$ TeV to a high precision by applying the principle of maximum conformality (PMC). The PMC provides a systematic method that rigorously eliminates QCD renormalization scale ambiguities by summing the nonconformal $\beta$ contributions into the QCD coupling constant. The PMC predictions satisfy the requirements of renormalization group invariance, including renormalization scheme independence, and the PMC scales accurately reflect the virtuality of the underlying production subprocesses. By using the PMC, an improved prediction for the $t\bar{t}$ production cross-section is obtained without scale ambiguities, which in turn provides a precise value for the top-quark pole mass. Moreover, the prediction of PMC calculations that the magnitudes of higher-order PMC predictions are well within the error bars predicted from the known lower-order has been demonstrated for the top-quark pair production. The resulting determination of the top-quark pole mass, $m_t^{\rm{pole}}=172.5\pm1.4$ GeV, from the LHC measurement at $\sqrt{S}=13$ TeV agrees with the current world average cited by the Particle Data Group (PDG). The PMC prediction provides an important high-precision test of the consistency of pQCD and the SM at $\sqrt{S}=13$ TeV with previous LHC measurements at lower CM energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient lattice QCD computation of radiative-leptonic-decay form factors at multiple positive and negative photon virtualities

In previous work [D. Giusti, Methods for high-precision determinations of radiative-leptonic decay form factors using lattice QCD, Phys. Rev. D 107, 074507 (2023)], we showed that form factors for radiative leptonic decays of pseudoscalar mesons can be determined efficiently and with high precision from lattice QCD using the “three-dimensional (3D) method,” in which three-point functions are computed for all values of the current insertion time and the time integral is performed at the data-analysis stage. Here, we demonstrate another benefit of the 3D method: the form factors can be extracted for any number of nonzero photon virtualities from the same three-point functions at no extra cost. We present results for the $D_s → ℓνγ*$ vector form factor as a function of photon energy and photon virtuality, for both positive and negative virtuality, for a single ensemble with 340 MeV pion mass and 0.11 fm lattice spacing. In our analysis, we separately consider the two different time orderings and the different quark flavors in the electromagnetic current. We discuss in detail the behavior of the unwanted exponentials contributing to the three-point functions, as well as the choice of fit models and fit ranges used to remove them for various values of the virtuality. While positive photon virtuality is relevant for decays to multiple charged leptons, negative photon virtuality suppresses soft contributions and is of interest in QCD-factorization studies of the form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand’s Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the fundamental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scattering provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon's internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (GMn) to unprecedented Q2 using Durand's method, also known as the "ratio" method. Systematic errors are greatly reduced by ext

Datta, Provakar↗

Implementing nonlinear optics from Off-Energy closed orbit at NSLS-II

To characterize the second-order (chromatic sextupole) magnet lattice with high precision, we implemented nonlinear optics from off-energy closed orbit (NOECO) tool based on the linear optics from closed orbit modulation (LOCOM) method, named LOCOM-NOECO. The preliminary numerical study indicates that 1–2% precision can be achieved for the calibration of chromatic sextupoles. Further, this accuracy could potentially help in resolving some long-standing challenges of NSLS-II (e.g., the discrepancy between the designed and measured dynamic apertures) if such high precision can be fulfilled. As an independent crosscheck, we also implemented NOECO based on the independent component analysis (ICA) method using turn-by-turn (TBT) BPM data, named ICA-NOECO. Both ICA-NOECO and LOCOM-NOECO have been successfully applied to identify the pre-dialed random errors of a chromatic sextupole family including five power supplies, and achieved the root mean square (RMS) residual error of 1% and peak error less than 2%. Moreover, to mitigate the chromatic sextupole error effect, we applied the correction and achieved significant improvements in the injection efficiency as well as the dynamic apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astrometric gravitational-wave detection via stellar interferometry

Here, we evaluate the potential for gravitational-wave (GW) detection in the frequency band from 10 nHz to 1 μ Hz using extremely high-precision astrometry of a small number of stars. In particular, we argue that nonmagnetic, photometrically stable, hot white dwarfs (WD) located at ~kpc distances may be optimal targets for this approach. Previous studies of astrometric GW detection have focused on the potential for less precise surveys of large numbers of stars; our work provides an alternative optimization approach to this problem. Interesting GW sources in this band are expected at characteristic strains around h c ~10 -17 × (μHz/ $f$ GW ). The astrometric angular precision required to see these sources is Δθ~h c after integrating for a time T~1/$f$GW. We show that jitter in the photometric center of WD of this type due to starspots is bounded to be small enough to permit this high-precision, small-N approach. We discuss possible noise arising from stellar reflex motion induced by orbiting objects and show how it can be mitigated. The only plausible technology able to achieve the requisite astrometric precision is a space-based stellar interferometer. Such a future mission with few-meter-scale collecting dishes and baselines of $\mathscr{O}$(100 km ) is sufficient to achieve the target precision. This collector size is broadly in line with the collectors proposed for some formation-flown, space-based astrometer or optical synthetic-aperture imaging-array concepts proposed for other science reasons. The proposed baseline is however somewhat larger than the km-scale baselines discussed for those concepts, but we see no fundamental technical obstacle to utilizing such baselines. A mission of this type thus also holds the promise of being one of the few ways to access interesting GW sources in this band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio study and assignment of electronic states in molecular RaCl

Radium compounds have attracted recently considerable attention due to both development of experimental techniques for high-precision laser spectroscopy of molecules with short-lived nuclei and amenability of certain radium compounds for direct cooling with lasers. Currently, radium monofluoride (RaF) is one of the most studied molecules among the radium compounds, both theoretically and recently also experimentally. Complementary studies of further diatomic radium derivatives are highly desired to assess the influence of chemical substitution on diverse molecular parameters, especially on those connected with laser cooling, such as vibronic transition probabilities, and those related to violations of fundamental symmetries. Here in this article high-precision ab initio studies of electronic and vibronic levels of diatomic radium monochloride (RaCl) are presented. Recently developed approaches for treating electronic correlation with Fock-space coupled cluster methods are applied for this purpose. Theoretical results are compared to an early experimental investigation by Lagerqvist and used to partially reassign the experimentally observed transitions and molecular electronic levels of RaCl. Effective constants of $\mathscr{P}$-odd hyperfine interaction W a and $\mathscr{P, T}$-odd scalar-pseudoscalar nucleus-electron interaction Ws in the ground electronic state of RaCl are estimated within the framework of a quasirelativistic Zeroth-Order Regular Approximation approach and compared to parameters in RaF and RaOH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Polarimetry

Electron polarimetry benefits from the ability to use processes with well- known analyzing powers, hence enabling high precision measurements. Several techniques are employed to measure electron beam polarization, including Mott, Møller, and Compton polarimetry. Each technique has particular advantages and disadvantages, depending on the application. This chapter will focus on the tech- niques used to measure electron beam polarization, with particular emphasis on the challenges and requirements for achieving high precision. The development of a conceptual design of a Compton polarimeter for the future Electron Ion Collider will also be discussed.

Gaskell, David↗

A fast two-stage algorithm for non-negative matrix factorization in smoothly varying data

This article reports the study of algorithms for non-negative matrix factorization (NMF) in various applications involving smoothly varying data such as time or temperature series diffraction data on a dense grid of points. Utilizing the continual nature of the data, a fast two-stage algorithm is developed for highly efficient and accurate NMF. In the first stage, an alternating non-negative least-squares framework is used in combination with the active set method with a warm-start strategy for the solution of subproblems. In the second stage, an interior point method is adopted to accelerate the local convergence. The convergence of the proposed algorithm is proved. The new algorithm is compared with some existing algorithms in benchmark tests using both real-world data and synthetic data. Furthermore, the results demonstrate the advantage of the algorithm in finding high-precision solutions.

interior point method↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Measurements and computational analysis of the natural decay of 176 Lu

Background: Mainly because of its long half-life and despite its scientific relevance, spectroscopic measurements of 176 Lu forbidden β decays are very limited and lack formulation of shape factors. A direct precise measurement of its Q value is also presently unreported. In addition, the description of forbidden decays provides interesting challenges for nuclear theory. The comparison of precise experimental results with theoretical calculations for these decays can help to test underlying models and can aid the interpretation of data from other experiments. Purpose: Perform the first precision measurements of 176 Lu β-decay spectra and attempt the observation of its electron capture decays, as well as perform the first precision direct measurement of the 176 Lu β-decay Q value. Compare the shape of the precisely determined experimental β spectra to theoretical calculations, and compare the end point energy to that obtained from an independent Q value measurement. Method: Here, the 176 Lu β-decay spectra measurements and the search for electron capture decays were performed with an experimental setup that employed lutetium-containing scintillator crystals and a NaI(Tl) spectrometer for coincidence counting. The β decay Q value was determined via high-precision Penning trap mass spectrometry (PTMS) with the LEBIT facility at the National Superconducting Cyclotron Laboratory. The β-spectrum calculations were performed within the Fermi theory formalism with nuclear structure effects calculated using a shell model approach. Results: Both β transitions of 176 Lu were experimentally observed and corresponding shape factors formulated in their entire energy ranges. The search for electron capture decay branches led to an experimental upper limit of 6.3×10 –6 relative to its β decays. The 176 Lu β-decay and electron capture Q values were measured using PTMS to be 1193.0(6) and 108.9(8) keV, respectively. This enabled precise β end point energies of 596.2(6) and 195.3(6) keV to be determined for the primary and secondary β decays, respectively. The conserved vector current hypothesis was applied to calculate the relativistic vector matrix elements. The β-spectrum shape was shown to significantly depend on the Coulomb displacement energy and on the value of the axial vector coupling constant gA, which was extracted according to different assumptions. Conclusion: The implemented self-scintillation method has provided unmatched observations of 176 Lu, independently validated by the first direct measurements of its β-decay Q value by Penning trap mass spectrometry. Theoretical study of the main β transition led to the extraction of very different effective gA and log10f values, showing that a high-precision description of this transition would require a realistic nuclear structure with nucleus deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

Study of the interaction between $Ξ$ baryons and light mesons via femtoscopy at the LHC

Meson-baryon systems with strangeness content provide a unique laboratory for investigating the strong interaction and testing theoretical models of hadron structure and dynamics. In this work, the measured correlation functions for oppositely charged $Ξ$-K and $Ξ$ − 𝜋 pairs obtained in high-multiplicity pp collisions at $\sqrt{𝑠}$ = 13 TeV at the LHC are presented. For the first time, high-precision data on the $Ξ$-K interaction are delivered at small relative momenta. The scattering lengths, extracted via the Lednický–Lyuboshits expression of the pair wavefunction, indicate a repulsive and a shallow attractive strong interaction for the $Ξ$-K and $Ξ$ − 𝜋 systems, respectively. The $Ξ$(1620) and $Ξ$(1690) states are observed in the $Ξ$ − 𝜋 correlation function and their properties, mass and width, are determined. These measurements are in agreement with other available results. Such high-precision data can help refine the understanding of these resonant states, provide stronger constraints for chirally motivated potentials, and address the key challenge of describing the coupled-channel dynamics that may give rise to molecular configurations .

Femtoscopy↗

A Parameter-masked Mock Data Challenge for Beyond-two-point Galaxy Clustering Statistics

The past few years have seen the emergence of a wide array of novel techniques for analyzing high-precision data from upcoming galaxy surveys, which aim to extend the statistical analysis of galaxy clustering data beyond the linear regime and the canonical two-point (2pt) statistics. We test and benchmark some of these new techniques in a community data challenge named “Beyond-2pt,” initiated during the Aspen 2022 Summer Program “Large-Scale Structure Cosmology beyond 2-Point Statistics,” whose first round of results we present here. The challenge data set consists of high-precision mock galaxy catalogs for clustering in real space, in redshift space, and on a light cone. Participants in the challenge have developed end-to-end pipelines to analyze mock catalogs and extract unknown (“masked”) cosmological parameters of the underlying ΛCDM models with their methods. The methods represented are density-split clustering, nearest neighbor statistics, BACCO power spectrum emulator, void statistics, LEFTfield field-level inference using effective field theory (EFT), and joint power spectrum and bispectrum analyses using both EFT and simulation-based inference. In this work, we review the results of the challenge, focusing on problems solved, lessons learned, and future research needed to perfect the emerging beyond-2pt approaches. The unbiased parameter recovery demonstrated in this challenge by multiple statistics and the associated modeling and inference frameworks supports the credibility of cosmology constraints from these methods. The challenge data set is publicly available, and we welcome future submissions from methods that are not yet represented.

Krause, Elisabeth [Univ. of Arizona, Tucson, AZ (U↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗